Haier AU96NFTAHA user guide manual

MRV Intelligent Network Air-conditioner
OPERATION MAUAL
OUTDOOR UNIT
AU55NFUAHA AU96NFTAHA AU96NFTBHA
No. 0010570516
Contents
Cautions-----------------------------------------1-4 Name and functions of each part---------------5 Installation instruction---------------------------6 Operation and performance------------------ 7-8 Operating conditions-----------------------------9 Troubleshooting---------------------------------10
Disposal of the old air conditioner
Before disposing an old air conditioner that goes out of use. Please make sure it's inoperative and safe. Unplug the air conditioner in order to avoid the risk of child entrapment.
It must be noticed that air conditioner system contains refrigerants, which require specialized waste disposal. The valuable materials contained in a air conditioner can be recycled. Contact your local waste disposal center for proper disposal of an old air conditioner and contact your loal authority or your dealer if you have any qestion. Please ensure that the pipework of your air conditioner does not get damaged prior to being picked up by the relevant waste disposal center, and contribute to environmental awareness by insisting on an appropriate, anti-pollution method of disposal.
Disposal of the packaging of your new air conditioner
All the packaging materials employed ing the package of your new conditioner may be disposed without any danger to the environment.
The cardboard box may be broken or cut into smaller pieces and given to a waste paper diposal service. The wrapping bag made of polyethylene and the polyethylene foam pads contain no fluorochloric hydrocarbon.
All these valuable materials may be taken to a waste collecting center and used again after adequate recycling.
Consult your local authorities for the mame and address of the waste materials collecting centers and waste paper diposal services nearest to your house.
Safety Instructions and Warnings
Before starting the air conditioner, read the information given in the User's Guide carefully.The user's guide contains very important observations relating to the assembly, operation and maintenance of the air conditioner.
The manufacturer does not accept responsibility for any damages that may airse due to non-observation of the following instruction.
Damaged air conditioners are not to be put into operation. In case of doubt, consult your supplier. Use of the air conditioner is to be carried out in strict compliance with the relative instructions set
forth in the User's Guide. Installation shall be done by professional people, don't install unit by yourself.
For the purpose of safety, the air conditioner must be properly grounded in accordance with spectifications.
The wiring method should be in line with the local wiring standand.
1
Cautions
Always remember to unplug air conditioner before opening inlet grill. Never unplug your air conditioner by pulling on the power cord. Always grip plug firmly and pull straight out from the outlet.
All electrical repairs must be carried out by qualified electricians. Inadequate repairs may result in a major source of danger for the user of the air conditioner.
Do not damage any parts of the air conditoner that carry refrigerant by piercing or perforating the air conditioner's tubes with sharp or pointed items, crushing or twisting any tubes, or scraping the coatings off the surfaces. If the refrigerant spurts out and gets into eyes, it may result in serious eye injuries.
Do not use this unit for any other purposes except for the Cooling,Heating. Dehumidifying, and air­circulation of rooms in ordinary dwellings.
Do not obstruct or cover the ventilation grille of the air conditioner. Do not put fingers or any other things into the inlet/outlet and swing louver.
Do not allow children to play with the air cinditioner. In no case should children be allowed to sit on the oudoor unit.
Specifications
1. If the supply cord is damaged, it must be replaced by the manufacturer or its service agent or a similar qualified person.
2. The wiring method should be in line with the local wiring standard.
3. The appliance must be installed on strong enough supporter.
4. The appliance is not intended for use by young children or infirm persons without supervision.
5. Young children should be supervised to ensure that they do not play with the appliance.
6. If the fuse on PC board is broken please change it with the type of AC250V 6.3A. If the fuse on main circuit is broken please change it with the same type of AC250V 20A or AC DC 600V 15A or AC DC 600V 7A.
2
Cautions
Important Points of Safety
*
*
Warning: Misuse may cause fatal result such as death or serious injury etc.
Caution: Misuse may cause human injury or damage of machine,in some case fatal
results. Content marked with this "forbidden" sign should be absolutely forbidden, otherwise may cause damage of machine and human injury of the user.
Content marked with this "compulsory" sign should be executed compulsively,
otherwise may cause damage of machine and human injury of the user.
Warnings
Installation by consignment Installation shall be carried out by after-sale service personnel. Installation by customers may cause water-leakage, creepage or fire accidents by improper operation.
Connections of the ground bus Ground bus shall not be connected to the coal gas pipes, water pipes, lightning rods or telephone lines. Improper grounding may cause creepage and electric injury.
Taken measures to prevent refrigerant from leakage Once concentration of the leaked refrigerant reached a certain limit, it shall result in lack of oxygen. If the room where air-conditioner is installed is very small, effective measures shall be taken to prevent the occurring of lack of oxygen even if the refrigerant leaks.
It is forbidden to put finger or objects into the inlet and outlet when the air-conditioner is under operation. The rotating fan may cause body injury and machine damage once it is touched.
Comply with the following important points of safety. Put these important points of attention and suggestions nearby and convenient for reference in need. Hand over this instruction manual to new user if you resell this machine.
The following four important points of safety and suggestions should be paid great attention:
If any abnormity occurs (such as the smell of empyreuma), please cut off the power and contact with the after-sale service personnel for resolution.
If the air-conditioner is still kept operating under such condition, it may be damaged and creepage or fire accidents may occur.
Please contact with the after-sale service personnel whenever the air-conditioner is to be demolished or reinstalled.
It is forbidden to make bold to change the air­conditioner. Improper change may cause creepage, water-leakage or fire accidents.
Please contact with our after-sale service personnel for repairing. Improper maintenance or repair may cause water-leakage, creepage and fire-accidents.
turn off the power supply switch
Cautions
3
Cautions
Air-conditioner should not be installed under circumstance with flammable gas. Flammable gas near the air-conditioner may cause fire accidents or explosion accidents.
Make sure air-conditioner is properly fastened. Improper fastening may cause accident once the air-conditioner turnover.
Installation of the electric leak breaker Shock accident may occur without installation of the electric leak breaker.
Base of air-conditioner shall be checked for damage after a long period of use. If the base is damaged and without repair, the unit may fall down thus cause injury accident.
Air-conditioner shall be cleaned only when the power is cut off in case creepage or other injury accident occurs.
Once the power supply cord is damaged, you shall contact with personnel of our manufacturing factory or maintenance branch.
Only right standard of fuse shall be used. It is strongly recommended not to use electrical wire or any other material to take the place of fuse. Otherwise faults or fire accidents may occur.
It is forbidden to place any flammable spraying liquid near the air-conditioner. Otherwise fire accident may occur.
Cautions
4
Please turn on the electrical power switch 12 hours ahead of the first operation. Please do not cut off the power for a day and night's short time break. This is for the protection of the air­compressor.
Be careful not to build up the inlet and outlet. Otherwise the performance of air-conditioner shall be reduced and protection set shall be into operation.
Cautions:
Outlet Heated wind blew out during cool operation Cooled wind blew out during Heat operation
Fixing up bolts Joining for refrigerant piping
Wring threading holes for power supply cord Inlet---situated on both the left and right side, and the back
Joining for refrigerant piping Fixing up bolts
Wring threading holes for power supply cord Inlet---situated on both the left and right side, and the back
Name and functions of each part
AU96NFTAHA AU96NFTBHA
AU55NFUAHA
5
Cautions
Air-conditioner shall not be installed under circumstance with flammable gas. Flammable gas near the air-conditioner may cause fire accidents or explosion accidents.
Installation site
Requirements
Not to install under circumstance with high frequency electromagnetic wave. Faults are subject to occur when air-conditioner is used under circumstance with oil or steamed gas, or in high salty costal area or hotspring area with sulfurized gas. Special maintenance shall be needed for use under above conditions. Wide space is needed between the inlet and outlet of the outdoor unit in case winding is blocked. Not to install air-conditioner into places where strong wind directly blows to the inlet or outlet of outdoor unit. Snow-proof rack and shield shall be equipped in area with more snowfall. For details please contact with our after-sale service personnel.
Operation noise
Please install air-conditioner in high-strength location in case the operation noise and vibration spreads to other places. Obstacles near the outlet of exterior machine shall strengthen the operation noise. Please avoid installing air-conditioner into locations near blew out cooled and heated wind by other outdoor unit or places where operation noise may effect neighbors.
Electrical wiring
Warnings
Grounding connection shall be equipped to ensure efficient grounding of the power. Improper grounding or without grounding of air-conditioner may cause creepage accidents. Ground bus shall not be connected to the gas pipes, water pipes, lightning rods or telephone lines. Improper grounding may cause creepage and electric injury.
Cautions
Creepage breaker shall be installed where air-conditioner is installed. Creepage accident may occur without installation of the creepage breaker. Creepage test shall be carried out after completion of electrical installation. Only right standard of fuse shall be used. It is strongly recommended not to use electrical wire or any other material to take the place of fuse. Otherwise faults or fire accidents may occur. Power shall be with rating voltage and special air-conditioner circuitry.
Installation instruction
6
When air-conditioner is re-operated immediately after turning off, it shall take about 3 minutes for the compressor to operate so as to protect the machine.
Time-lag function
Multi air-conditioner system driven by one outdoor unit has separate control of interior machines. Cool producing and heat producing shall not be carried out simultaneously by such system. Whenever cool producing and heat producing is carried out simultaneously by such system, the indoor cool producing machine shall stop working and on call status shall be shown on the liquid crystal display of remote controller. Indoor heat producing machine shall be under normal operation.
Operation of multi air-conditioner system driven by one outdoor unit
Once controller set functions like concentrating, locking, chose cool producing or heat producing, it is impossible for other people to carry out functions beyond the enactment.
Whenever outdoor temperature rises, fan of outdoor unit shall operate in low speed.
Performance of heat producing
Defrosting shall be carried out automatically whenever the outdoor unit is frosting during heat producing. This is for improve the heat producing effect. Meanwhile, water shall be drained from outdoor unit.
Fan of indoor unit shall operate in low speed or stop operating and fan of outdoor unit shall stop operating during defrosting.
Defrosting during heat producing
Operation and performance
7
Operation and performance
8
Cooling
Please keep the air-conditioner under conditions in the following table during operation to ensure proper use of it.
Operating conditions
Heating
Outdoor temperature (D.B.)
Indoor temperature (W.B.)
Indoor humidity
Outdoor temperature (W.B.)
Indoor temperature (D.B.)
Above -5oC and below 43 oC
Above 14oC and below 23 oC
Humidity under 80% Whenever air-conditioner is operating under circumstance with humidity above 80% for long term, defrosting shall be formed and dropped on the machine surface, mirage shall be blew off from the outlet.
Above -15oC and below 15 oC
Above 15oC and below 27 oC
Protection unit shall come into operation under such conditions.
Protection set (high-pressure switch)
High-pressure switch is the automatic stop system for air-conditioner whenever air-conditioner is running abnormally. When protection set operates, cool producing or heat producing shall stop. The operating indicator light of remote controller is still on. When protection set operates, the "self-check" indicator light of remote controller shall blink
Protection set shall operate whenever one of the following occurs: During cool producing process: Inlet or outlet of outdoor unit is blocked Outlet of outdoor unit is blown directly by strong wind.
During heat producing process: Dust accumulated on the air filter of indoor unit Outlet of indoor unit is blocked
Power switch shall be turned off whenever the protection set operates and air-conditioner
shall be operated again only after defaults checked out.
Once power cut occurs during operation, all operation shall stop.
Power on again after power cut, the operating indicator light of remote controller shall blink.
Press "ON/OFF" switch for re-operation.
Power cut
Heat producing is on the basis of absorbing outdoor heat and letting it indoor by heat pump. Therefore heat-producing ability shall reduce once outdoor temperature drops.
Other heat-producing machine may be used together when outdoor temperature is low.
For details please refer to instruction manual of indoor unit.
Heat producing performance
Operating conditions
9
Phenomenon Causes
Non-fault
White frost blowing off or water overflowing
Gives off loud noise
Fan of outdoor unit stop automatically and defrosting operates
The voice of electromagnetic valve operation whenever defrosting starts or ends. Water-flowing sound during operating and after operation stops. Operating sound shall get louder during the first 2-3 minutes after operation starts. This is the sound of refrigerant circulation and cooled water drainage. Noise may occur during operation due to heat expansion and cool shrinkage of the heat exchanger.
Failed to reach rated cool or heat producing effect
Check if cool producing and heat producing are set simultaneously and if liquid crystal indicator of remote controller is showing "on-call".
Occasions needs further check
Auto run or turn off
Check if remote controller is set at the mode to run or turn off at certain time.
Failed into operation
Failed into operation Check if power cut occurs Check if power switch is turned off Check if fuse or breaker is burned out (it shall be repaired by qualified personnel with certification) Check if protection set is into operation. (whenever indicator light of remote controller is on). "Self-check" indicator light of remote controller shall blink.
Failed to reach rated cool or heat producing effect
Check if inlet or outlet of outdoor unit is blocked. If any door or window is not closed. If dust accumulated on the air filter of indoor unit (power switch shall be turned off and air filter be cleaned on such occasion) If wind board is at proper situation (adjust its location) If wind volume is set at "breeze" and the operation status is at "sending wind" If the temperature set is correct.
Power switch shall be turned off and operation be stopped if the following listed occurs. Please contact with after-sale service personnel. Key operation is not proper. Fuse and breaker are burned out. Eyewinker or water comes enter the electrical box. All causes of protection unit are eliminated and air-conditioner fails to run again. Other abnormity occurs.
Troubleshooting
10