Haier AU84NBTBAA User Manual

Haier Network Air Conditioner
Two by One Type Room Air Conditioner Outdoor unit
For the sake of safety and in order to use the air conditioner correctly, please read this manual and the operation manual of indoor unit carefully before using After reading this attached manual, please keep it properly. If the user is changed, please do give this manual to him
CONTENTS
Safety Precautions Name of Parts and Functions
Installation Instruction Operation and Performance
Troubleshooting
Installation Instruction Installation of Outdoor unit Electric Wiring
AU84NBTBAA
No. : 0010571817 A
: Those contents marked with ìProhibitionî are definitely prohibited action, otherwise, it may cause unit damage or risk to usersí safety. : Those contents marked with ìForcedî are definitely forced action, other­ wise, it may cause unit damage or risk to usersí safety.
The following lists four kinds of safety precaution items and suggestions:
The following safety precautions must be observed. This safety precautions should keep in hand for reference. When transfer the air conditioner to a new user, this manual should also be given to the new user together with the unit.
Warning
Commissioned installation The installation work should be done by the after-sales service worker. Selfinstallation may cause water leakage, electric shock and fire accident because of improper installation.
Ask after-sales service worker to take measure to prevent refrigerant from leaking. If the leaked refrigerant exceeds a certain density, it will cause lack of oxygen. If the room installed with air conditioner is too small, do take enough measure in order to avoid lack of oxygen even if refrigerant leaks.
If abnormal conditions (sear smell) occur, please stop the unit, turning off the electric power and contact the after-sales service center for solution.
When the air conditioner must be dismantled and reinstalled, please ask the after-sales service center to do this work. Improper installation may cause water leakage, electric shock and fire.
Warning: Improper use may cause death or serious injury. Notice: Improper use may cause body hurt or unit damage; in some
circumstance, it may cause serious results.
Safety Precautions
Equip the grounding wire The grounding wire cannot be connected to gas pipe, city water pipe, lightning rod or telephone line. Improper grounding may cause electric shock.
During the unit operation, do not insert fingers or other articles alike into the air inlet, outlet and louver. Because the high-speed fanis very dangerous, it may cause hurt.
If still using the unit under this circumstance, the air conditioner may be damaged and may also cause electric shock or fire accidents.
It is strictly prohibited to rebuild the air conditioner by yourself. Improper rebuilding may cause fire, electric shock and water leakage.
When needing repair, please ask the after-sales service work for help. Improper maintenance and repair may cause water leakage, electric shock and fire.
1
Cut off power
Safety Precautions
Notice
Do not install the air conditioner in a place where the inflammable gas maybe exists. The inflammable gas around the air conditioner may cause fire accident.
Confirm the fixing method. If the air conditioner is not fixed firmly and reliably, because of the overturn of the unit may cause accident.
The creepage breaker should be equipped. If not equipped with creepage breaker, it may cause creepage.
After a long-time using of the air conditioner, please check if the foundation of the unit is damaged. If the foundation is damaged without repair, the unit may fall down leading to body hurt.
Only after stopping the unit and cutting off power can clean the air conditioner to avoid electric shock or injury.
If the power cable is damaged, in order to avoid danger, it must be replaced by the manufacturer or its repair service center of the similar qualified worker.
Only use the proper specified fuse: T3.15A 1250VAC Do not use cable or other materials to replace the fuse, otherwise it may cause fire and other trouble.
Do not put or use any spray near the air conditioner, otherwise it may cause fire.
2
Name of Parts and Functions
Note:
Do not block the air inlet and air outlet, otherwise the performance of the air conditioner may be lowered and it will make the protection device act.
Air outlet
In COOLING operation, it blows out hot air.
In HEATING operation, it blows out cold air.
Fixing screw bolt
The interface of the refrigerant pipe (two sides)
The wire hole for power cable
Air inlet Right and left two sides and rear,
totally 3 sides
Installation Instruction
Notice
Do not install the air conditioner in a place where the inflammable gas maybe exists. The inflammable gas around the air conditioner may cause fire accident. Make sure if the outdoor unit is firmly fixed on the foundation. Improper installation may cause fall over leading to accident.
Avoid the place where high frequency electromagnetic waves are generated. A void the place with to much oil, vapor and salinity, such as, seashore and hotspring area and the area with sulfurated gas, etc. corrosive gas. If install in these places, trouble easily occurs and the air conditioner needs special maintenance. The space around the air inlet and outlet of the outdoor unit is open not influe ncing ventilation. Avoid the place where the strong wind directly blows to the air inlet and outlet of outdoor unit. When using the air conditioner in the area with heavy snowfall, the outdoor unit must be equipped with snow-protective frame and snow-protective cover. For details, please contact the after-sales service worker.
Installation place
Requirements:
Install in the place with intensity as high as possible to prevent the noise and vibration from spreading to other places. If there is obstacle around the air outlet of the outdoor unit, the operation noise may become higher. Place where the operation noise, cold air and hot air will not disturb the neighbors.
Operation noise:
Electric wiring:
Warning
The power cable must equip with grounding wire to guarantee the air conditioner is effectively grounded through the power cable. Not grounded or improper grounding may cause electric shock. Do not connect the grounding wire to the gas pipe, city water pipe, lightning rod or telephone line.
Notice
No matter in any installation place, a creepage breaker must be installed. If do not install creepage breaker, it may cause electric shock, etc. accidents. After finishing wiring, power on the unit to perform the electricity leakage detection. The breaker of the air conditioner should be all-pole switch,and the distance between its two contacts should be on less 3mm.Such means for disconnection must be incorporation in the fixed wiring. Only use the proper specified fuse. Do not use cable or other materials to replace the fuse, otherwise it may cause fire and other trouble. The power supply should be complied with the specified rated voltage and use the special circuit for air conditioner only.
4
Loading...