Haier AU142AFBEA, AU182AFBEA Schematic

Service Manual
Commercial Air Conditioning
14 18 Universal Outdoor Fixed Frequency Series
AC142ACBEA+AU142AFBEA
AD142AMBEA+AU142AFBEA
AB142ACBEA+AU142AFBEA AC182ACBEA+AU182AFBEA
AD182AMBEA+AU182AFBEA
AB182ACBEA+AU182AFBEA
Features
Fixed frequency Auto-restart function Group control(if with a group controller)
Auto-changeover
The Outdoor unit can match with cassette \convertible\duct indoor
Weekly timing(if with a weekly timer) With new environment friendly refrigerant R407C
MANUAL CODE: SYJS-007 rev.0
CONTENTS
CONTENTS
Contents
1. Description of Products & Features…………...…….1
2. Specifications…………………. ………………...……3
3. Mechnical Data………………..…...………………. 7
4. Electrical Data…… …......…....…..… 36
5.Performance Curves ………...….…………. ………..45
6. Charts …………………….........……..…… ..………47
7. Electrical Control Functions …..........………………56
8.Diagnostic Information (Trouble Shooting) ...............62
9. Installation Instructions and Maintenance ….......…67
10. Exploded Views and Parts lists...............…. ……102
- 1 -
DESCRIPTION OF PRODUCTS & FEATURES
1 DESCRIPTION OF PRODUCTS & FEATURES
1.1 Products coding direction
Old code
H BU – 14 H A 03/ R1
Refers to HFC refrigerant, fixed frequency
Power: 03(230V/50Hz).04(240V/50Hz).12(115V/60Hz).13(230v/60Hz) Design series number “H” refer to cooling and heating, ”C” refer to cooling only Nominal cooling capacity (BTU/h), 14=14000BTU/h Indoor unit code: "B" Cassette type; "C" convertible "D" Duct type “H” means “Haier”
New code
A B 14 2 A C B E A
Climate type: T1 (see table 1)
Design number (E stands for fixed frequency heat pump air conditioner) Product type: A stands for heat pump type, refrigerant is R22 B stands for heat pump type, refrigerant is R407 M stands for cool only type, refrigerant is R22 N stands for cool only type, refrigerant is R407 Appearance character Product series: one wall-mounted split type Applicable voltage: 2 stands for 220-240V/50Hz,4 stands for 220v/60Hz N stand for 380V/50Hz Cooling / Heating capacity,14=14000BTU/h Product type : “B” stands for cassette type, “C” stands for convertible type, ”D” stands for duct, “S” stands for split type, ”Q” stands for chiller
Air conditioner
system, "E" stands for ceiling concealed type, “U” stands for outdoor unit
1.2 Brief Introduction to T1 T2 T3 working condition
Table 1
Type of Air Conditioner
Climate type
T1 T2 T3 Cool only Heat pump Electricity heating
18
-7
43 10 35 21 52
43 -7 35 -7 52
43 35 52
1.3 Operating Range of air conditioners
Normal condition
Operation Operation Range Outside / Inside
Cooling
Drying
Heating
150C – 43oC
150C – 43oC
-7oC – 18oC
NEW
NEW
NEW
DESCRIPTION OF PRODUCTS & FEATURES
1.4 Products characteristic
The outdoor unit can match with different indoor unit
The indoor unit can be cassette type\convertible type and duct type. Due to its compact size it neither breaks the harmonization of indoor decoration nor occupies the indoor spaces. The stylish appearance of air conditioner allows it to blend right into ceiling.
Superbly efficient healthy filter
Superbly efficient antibiotic materials are utilized and can prevent germs from breeding efficiently.
Flexible and easy installation
Slim design with machine body, completely ceiling concealed and portable shape, all make it greatly easier to install. Moreover, it occupies least constructional spaces, which help to reduce constructional cost prices. It also features a specific drainage system with up to 600mm lift, which allows reducing installation spaces and ensures to drain smoothly. Thanks to its "smudge-free" mobile outlet grill, the ceiling can be protected from pollution effectively and allow the airflow to fit people's comfortable need much more. ESP can be from 0Pa to 50Pa; in the meantime, the duct unit is equipped with a filter and air return box.
Auto-Restart function
When meeting a power failure during running, no matter how long it will be, once the power is restored, air conditioner will automatic restart with the previous status.
Safety and reliable control due to various signal controls
1.Inputting with press buttons on the panel
2.Inputting with temperature sensors (indoor ambient temperature sensors, indoor coil pipe temperature sensors)
3.Piping pressure signals
4.Compressor current signals
5.Testing signals
6.System time-shorten signal
7.Water overflowing signal
8.Communication signals between indoor unit and front plate or between indoor unit and outdoor unit.
Universal convenient remote-controller
When using remote-controlling mode, it is comfortable and convenient to operate. The remote controller is used as new style; it looks like a phone, very compact. It is a universal controller and can be used for any unit such as single unit, multi free unit, MRV, etc. compatible with the old ones.
New wired controller
One wired controller can control 16 indoor units without any other device such as detector.
Silent design
The use of radial outward flow turbine fan produces large airflow volume and acts to significantly decrease operating noise.
Low ambient temperature cooling function (optional) Equipped with high/low pressure protection switch
2 SPECIFICATIONS
item Model
Function Capacity KW Capacity BTU/h Total power input W Max. power input W
EER
or COP Dehumidify capacity Power cable Power source Running /Max.Running current A / A Start current A
Unit model (color) Fan type×number
speed (H-M-L) r/min Fan motor output power W Air-flow(H-M-L) m³/h
Heat exchanger
Type / Diameter Total Area Temp. scope
Dimension
indoor unit
Drainage pipe (material , I.D./O.D.) mm Control type (Remote /wired) Fresh air hole dimension mm Electricity Heater Noise level (H-M-L) Weight (Net / Shipping)
Dimension
Panel
Weight (Net / Shipping)
External Package
External Package
L×W×H) (L×W×H
L×W×H) (L×W×H
W/W
10³×m³/h
NVHz
mm
mm×mm×mm
mm×mm×mm
kW
dB(A)
kg / kg
mm×mm×mm
mm×mm×mm
kg / kg
Unit model (color)
Compressor
Model / Manufacture Type Type × Number
Fan
Speed r/min Fan motor output power kW Air-flow(H-M-L) m³/h Type / Diameter mm
Heat exchanger
Dimension
Outdoor unit
Drainage pipe (material , I.D./O.D.) mm
Total area m² Temp. scope External Package
L×W×H) (L×W×H
mm×mm×mm
mm×mm×mm
Refrigerant control method mm/mm Defrosting Volume of Accumulator L Noise level dB(A) Type of Four way valve material of reduce noise crankcase heater power W Weight (Net / Shipping)
Refrigerant
Pipe
Connecting Method
PIPING
Between I.D &O.
Type / Charge g Recharge quantity g/m Liquid mm Gas mm
MAX.Drop MAX.Piping length
kg / kg
m m
AU142AFBEA/AB142ACBEA
cooling heating
4.10 4.39
14000 15000
1550 1450 1800 1800
2.65 3.03
2.95
2X2.0+2X0.75
1PH 220V-230V 50HZ
cooling:7.8/8.5 heating:6.8/8.5
40
AB142ACBEA (grey)
centrifugal×1
900±30/850±30/750±30/610/540
20
1100/1000/900
9.52
653*200*65
5-10 700*570*276 775*715*361
PVC26/32
remote
100
0
53.5/51.5/49.8 26/28
630*630*93
685*685*155
4.2/6.3
AU142AFBEAWHITE
PG260X2CS-4KT1 toshiba
rotary
Axial-flow
820±30
35
2300
TP2M/9.52
0.92
43-60
780x650x250 903x714x343
/
main: 1.7*400auxiliary:2.0*140
auto
/
58/--/50
/
XPE
/
41/43
R407C 1600
50
6.35
12.7
flared
20
30
item Model Function Capacity KW Capacity BTU/h Total power input W Max. power input W
or COP
EER Dehumidify capacity
W/W
10³×m³/h
Power cable Power source
NVHz
Running /Max.Running current A / A Start current A
Unit model (color) Fan type×number
speed (H-M-L) r/min Fan motor output power W Air-flow(H-M-L) m³/h
Heat exchanger Type / Diameter mm
Total Area
Dimension
indoor unit
Temp. scope External Package
L×W×H) (L×W×H
mm×mm×mm
mm×mm×mm
Drainage pipe (material , I.D./O.D.) mm Control type (Remote /wired) Fresh air hole dimension mm Electricity Heater / Noise level (H-M-L) Weight (Net / Shipping)
Dimension
Panel
Weight (Net / Shipping)
External Package
L×W×H) (L×W×H
kW
dB(A)
kg / kg
mm×mm×mm
mm×mm×mm
kg / kg
Unit model (color)
Compressor
Model / Manufacture Type Type × Number
Fan
Speed r/min Fan motor output power kW Air-flow(H-M-L) m³/h Type / Diameter mm
Heat exchanger
Dimension
Outdoor unit
Drainage pipe (material , I.D./O.D.) mm
Total area m² Temp. scope External Package
L×W×H) (L×W×H
mm×mm×mm
mm×mm×mm
Refrigerant control method mm/mm Defrosting Volume of Accumulator L Noise level dB(A) Type of Four way valve material of reduce noise crankcase heater power W Weight (Net / Shipping)
Refrigerant
Pipe
PIPING
Connecting Method
Between I.D &O.
Type / Charge g Recharge quantity g/m Liquid mm Gas mm
MAX.Drop 20
D
MAX.Piping length 30
kg / kg
m m
AU142AFBEA/AC142ACBEA
cooling heating
4.10 4.39
14000 15000
1550 1450 1800 1800
2.65 3.03
2.95
2X2.0+2X0.75
1PH 220V-230V 50HZ
cooling:7.8/8.5 heating:6.8/8.5
40
AC142ACBEA (white)
centrifugal×2
1350±30/1280±30/1210±30
20W
1100/1000/900
9.52
653*200*65
5-10 830*450*225 976*526*288
PVC26/32
remote
/
53.5/51.5/49.8 20/22
/ / /
AU142AFBEAWHITE
PG260X2CS-4KT1 toshiba
rotary
Axial-flow
820±30
35
2300
TP2M/9.52
0.92
43-60
780x650x250 903x714x343
/
main: 1.7*400auxiliary:2.0*140
auto
/
58/--/50
/
XPE
/
41/43
R407C 1600
50
6.35
12.7
flared
Norminal condition: indoor temperature (cooling): 27 DB/19WB, indoor temperature (heating): 20DB Outdoor temperature(cooling): 35DB/24WB, outdoor temperature(heating): 7 DB/6℃WB
item Model Function Capacity KW Capacity BTU/h Total power input W Max. power input W EER Dehumidify capacity Power cable Power source Running /Max.Running current A / A Start current A
AU142AFBEA/AD142AMBEA
cooling heating
4.10 4.39
14000 15000
1550 1450 1800 1800
or COP
W/W
2.65 3.03
10³×m³/h
NVHz
1PH 220V-230V 50HZ
cooling:7.8/8.5 heating:6.8/8.5
Unit model (color)
AD142AMBEA (white)
Fan type×number
speed (H-M-L) r/min
1290±30/1220±30/940±30/710±40 Fan motor output power W Air-flow(H-M-L) m³/h
Heat exchanger Type / Diameter mm
Total Area m² Temp. scope
Dimension
indoor unit
External Package
L×W×H) (L×W×H
mm×mm×mm
mm×mm×mm
Drainage pipe (material , I.D./O.D.) mm Control type (Remote /wired) Fresh air hole dimension mm Electricity Heater / Noise level (H-M-L) Weight (Net / Shipping)
Dimension
Panel
Weight (Net / Shipping)
External Package
L×W×H) (L×W×H
Unit model (color)
Compressor
Model / Manufacture Type
kW
dB(A)
kg / kg
mm×mm×mm
mm×mm×mm
kg / kg
AU142AFBEAWHITE
PG260X2CS-4KT1 toshiba
Type × Number
Fan
Speed r/min Fan motor output power kW Air-flow(H-M-L) m³/h Type / Diameter mm
Heat exchanger
Dimension
Outdoor unit
Drainage pipe (material , I.D./O.D.) mm Refrigerant control method mm/mm
Total area m² Temp. scope External Package
L×W×H) (L×W×H
mm×mm×mm
mm×mm×mm
main: 1.7*400auxiliary:2.0*140
Defrosting Volume of Accumulator L Noise level dB(A) Type of Four way valve material of reduce noise crankcase heater power W Weight (Net / Shipping)
Refrigerant
Pipe
PIPING
Connecting Method
Between I.D &O.
Type / Charge g Recharge quantity g/m Liquid mm Gas mm
MAX.Drop 20
D
MAX.Piping length 30
kg / kg
m m
2.95
2X2.0+2X0.75
40
centrifugal×2
20W
950/850/770
9.52
653*200*65
5-10 830*450*225 980*543*305 PVC18/21
remote
/
40/38/36
25/28
/ / /
rotary
Axial-flow
820±30
35
2300
TP2M/9.52
0.92
43-60 780x650x250 903x714x343
/
auto
/
58/--/50
/
XPE
/
41/43
R407C 1600
50
6.35
12.7
flared
Norminal condition: indoor temperature (cooling): 27 DB/19WB, indoor temperature (heating): 20DB Outdoor temperature(cooling): 35DB/24WB, outdoor temperature(heating): 7 DB/6℃WB
item Model Function Capacity KW Capacity BTU/h Total power input W Max. power input W EER or COP Dehumidify capacity Power cable Power source
Running /Max.Running current A / A Start current A
Unit model (color) Fan type×number
speed (H-M-L) r/min Fan motor output power W Air-flow(H-M-L) m³/h
Heat exchanger Type / Diameter mm
Total Area
Temp. scope
Dimension
indoor unit
Drainage pipe (material , I.D./O.D.) mm
Control type (Remote /wired)
Fresh air hole dimension mm Electricity Heater Noise level (H-M-L)
Weight (Net / Shipping)
Dimension
Panel
Weight (Net / Shipping)
Refrigerant
Pipe
PIPING
Connecting Method
Between I.D &O.D
Norminal condition: indoor temperature (cooling): 27 DB/19WB, indoor temperature (heating): 20DB Outdoor temperature(cooling): 35DB/24WB, outdoor temperature(heating): 7 DB/6℃WB
External
Package
External
Package
Type / Charge g Recharge quantity g/m Liquid mm Gas mm
MAX.Drop MAX.Piping length
L×W×H) (L×W×H
L×W×H) (L×W×H
WW
10³×m³/h
NVHz
mm×mm×mm
mm×mm×mm
kW
dB(A)
kg / kg
mm×mm×mm
mm×mm×mm
kg / kg
m m
cooling heating
18000 20000
cooling: 10/12 heating: 9.5/14
AB182ACBEA
5.27 5.86
2000 1900 2400 2800
2.64 3.08
1.2
4X0.75
1PH 220V-230V 50HZ
50
AB182ACBEA(WHITE)
CENTRIFUGAL*1
500±30/450±40/380±50
0.04
1050/945/790
TP2M/7
0.199
2-7
750×750×280 900×900×460
PVC 26/32
remote
/ /
43/42/40
29/39
750x750x80
800x800x180
3.5/5.8
R407C 1950
30
6.35
15.88
flared
20 30
item Model Function Capacity KW Capacity BTU/h Total power input W Max. power input W EER or COP Dehumidify capacity Power cable
Power source
Running /Max.Running current A / A Start current A
Unit model (color) Fan type×number
speed (H-M-L) r/min Fan motor output power W Air-flow(H-M-L) m³/h
Heat exchanger Type / Diameter mm
Total Area
Temp. scope
Dimension
indoor unit
Drainage pipe (material , I.D./O.D.) mm
Control type (Remote /wired)
Fresh air hole dimension mm Electricity Heater Noise level (H-M-L)
Weight (Net / Shipping)
Refrigerant
Pipe
PIPING
Connecting Method
Between I.D &O.D
Norminal condition: indoor temperature (cooling): 27 DB/19WB, indoor temperature (heating): 20DB Outdoor temperature(cooling): 35DB/24WB, outdoor temperature(heating): 7 DB/6℃WB
External
Package
Type / Charge g Recharge quantity g/m Liquid mm Gas mm
MAX.Drop MAX.Piping length
L×W×H) (L×W×H
W/W
10³×m³/h
NVHz
mm×mm×mm
mm×mm×mm
kW
dB(A)
kg / kg
m m
cooling heating
18000 20000
cooling: 10/12 heating: 9.5/14
AC182ACBEA
5.27 5.86
2000 1900 2400 2800
2.64 3.08
2.1
4X0.75
1PH 220V-230V 50HZ
50
AC182ACBEA(WHITE)
CENTRIFUGALX2
1070+30/1000+40/940+50
0.04
900/840/790
TP2M/9.52
0.199
2-7
1990×655×199 1150×750×300
PVC 18/20
remote
/ /
48/44/38
30/39
R407C 1950
30
6.35
15.88 flared
20 30
item Model Function Capacity KW Capacity BTU/h Total power input W Max. power input W EER or COP Dehumidify capacity Power cable Power source
Running /Max.Running current A / A Start current A
Unit model (color) Fan type×number
speed (H-M-L) r/min Fan motor output power W Air-flow(H-M-L) m³/h
Heat exchanger Type / Diameter mm
Total Area
Temp. scope
Dimension
indoor unit
Drainage pipe (material , I.D./O.D.) mm
Control type (Remote /wired)
Fresh air hole dimension mm Electricity Heater Noise level (H-M-L)
Weight (Net / Shipping)
Refrigerant
Pipe
PIPING
Connecting Method
Between I.D &O.D
Norminal condition: indoor temperature (cooling): 27 DB/19WB, indoor temperature (heating): 20DB Outdoor temperature(cooling): 35DB/24WB, outdoor temperature(heating): 7 DB/6℃WB
External
Package
Type / Charge g Recharge quantity g/m Liquid mm Gas mm
MAX.Drop MAX.Piping length
L×W×H) (L×W×H
WW
10³×m³/h
NVHz
cooling: 10/12 heating: 9.5/14
mm×mm×mm
mm×mm×mm
kW
dB(A)
kg / kg
m m
AD182AMBEA
cooling heating
5.27 5.86
18000 20000
2000 1900 2400 2800
2.64 3.08
1.2
4X0.75
1PH 220V-230V 50HZ
50
AD182AMBEA(WHITE)
CENTRIFUGALx2
780+30/710+30/630+50
0.13
850/770/680
TP2M/9.52
0.199
2-7
990×650×300
1137×800×320
PVC 26/32
wired+remote
/ /
33/31/28
38/55
R407C 1950
30
6.35
15.88 flared
20 30
g
g
y
ping
item Model Function
Capacit Capacity BTU/h
Total power input Max. power input
EER or COP
Dehumidifying capacity Power cable Power source
Running /Max.Running
Start Current A
Unit model (color) Compressor Model / Manufacture
Type
Fan Type × Number
Speed r/min Fan motor output power kW Air-flow(H-M-L) m³/h
Heat exchanger Type / Diameter mm
Total area m² Temp. scope
Dimension
Outdoor unit
Drainage pipe (material , I.D./O.D.) mm Refrigerant control method mm/mm Defrosting Volume of Accumulator L Noise level dB(A) Type of Four way valve material of reduce noise crankcase heater power W Weight (Net / Shipping) Refrigerant Type / Charge g
Pipe
PIPING
Connecting Method
Between I.D &O.
Norminal condition: indoor temperature (cooling): 27DB/19WB, indoor temperature (heating): 20DB Outdoor temperature(cooling): 35DB/24WB, outdoor temperature(heating): 7DB/6WB
External Package
Recharge quantity g/m Liquid mm Gas mm
MAX.Drop 20 MAX.Pi
L×W×H) (L×W×H
length 30
KW
W W
W/W
10³×m³/h
NVHz
A / A
mm×mm×mm
mm×mm×mm
kg / kg
m m
Coolin
5.27 5.86
18000 20000
2000 1900 2400 2800
2.64 3.08
cooling: 10/12 heating: 9.5/14
PG330X2CS-4KU1 Toshiba
Main capillary2.0x450Sub-capillary2.0x200
AU182AFBEA
1PH 220V-230V 50HZ
AU182AFBEA(WHITE)
810x288x680 960x406x760
R407C 1950
Heatin
2.1
4X0.75
50
Rotary
Axial-flow
820±30
35
2000
TP2M/9.52
0.72
43-60
/
Auto
/
52/--/46
/
XPE
/
59/66
30
6.35
15.88 Flare
3 MECHANICAL DATA
3.1 Drawings / Dimensions
3.1.1 Cassette Indoor unit
Swing louver (Air flow direction can be adjusted by using the SWING button on the remote controller)
Electrical Components Case
Air Inlet Grille
3.1.2 outdoor unit
Air Filter (Inside of the Inlet Grille)
Air inlet
Compressor(inside of unit)
Air outlet
18 series
Dimension
(Ceiling opening hole)
e l
e c t
r i
c a l
b o x
) e l o h
g n i n e p o
g
)
n i
l i
e C
( 悬 (
400
190
65
75
N
I
M
110
150
.
N
I
M
M
I
N
.
.
M
I
N
.
Needed minimum position
480
265
30
170
200
220
680
100 100
810
580
288
Convertible type
Fig.1
Dimension
Fig.2
1
POWER OPER TIMER COMP
EMER
4
5 6
7
2 3
1110
3
9
8
Fig.1 Indoor Unit
1 Operating Control Panel (Fig.2) 2 Emergency switch 3 Remote Control Signal Receiver 4 Power Indicator Lamp (Red) 5 OPERATION Indicator Lamp (Green) 6 TIMER Indicator Lamp (Yellow) 7 Compressor Run Lamp (Green) 8 Intake Grill (Fig.3) 9 Air Filter
10
UP/DOWN Air Direction Flaps
11
RIGHT/LEFT Air Direction Louvers
(behind UP/DOWN Air Direction Flaps)
5 5 6
0 0 2
240
9
ceiling concealed type Indoor unit
fan inside
motor inside
electric control box
C
B
air duct
evaporator
A
@
G
D
?
E
9JLM?HH?MGKJ BGICJLGKJ4 +=JGM4 II,
<>;8
57.1/5:685
?@ABCDEFG
2-- 30- 12- //2 3- //2 ./0 // .--
F
7.Remote controller functions
Remote controller
29 30 31
32 33 34
35 36
1
2 3
4
5
6 7
8
9
SWING
RESET
M D
MODE
HEALTH
CLOCK
TIMER
FILTER
CODE
A U T O
OFF
TEMP
ON
OFF
FRESH
LIGHT
SLEEP
HIGH/SO
LOCK
SET
4.Operation MODE
28
B
A
FAN
27
26 25 24
23 22
21 20
19
18
17 16
15
14
13
12
11
Used to select operation mode. Every time you press MODE button, operation mode
changes according to following sequence:
AUTO
COOL
DRY
HEAT
FAN
5.HEALTH Button
Used to set health mode, if the unit has the negative ion function and oxygen bar function.
6.CLOCK Button
Used to set correct time.
7.CLOCK Button
Used to select TIMER ON, TIMER OFF.
(Note: if time of TIMER ON is the same as TIMER OFF ,TIMER ON/OFF cannot be set)
8. FILTER Button
Used to set up/down function of filter.
9. CODE Button
Used to select code A or B, for this unit, the code is A.
10
1.TEMP Setting Button
(Used to set temperature. Setting ranges: 16 C to 30 C)
In Up/Down function, for controlling up and down filter.
2.SWING Button
If you press this button once, auto swing will be activated. If you press this button again, the louver will fix in the present position.
3.Power ON/OFF Button
Used for unit start and stop After power on, the LCD of remote controller
will display the previous operation state (except for TIMER,SLEEP and SWING state).
10.RESET Button
Press this button by using a sharp article to resume the correct operation of the remote controller in case of need, i.e. for example in case of malfunctions due to electromagnetic noise.
11.LOCK Button
Used to lock operation button and LCD display contents: by pressing this button, other buttons comes out of function and lock state display appears; if you press it again, lock state will be no more active and lock state display will disappear.
12.LIGHT Button
Used to light the control panel (only for cabinet unit)
13.Up and down Button
Used to set TIMER and CLOCK up or down.
14.HIGH/SO Button
Used to select HIGH or SOFT operation.
15.SET Button
Used to confirm TIMER and CLOCK settings.
16.FRESH Button
Used to set fresh mode, the unit will draw in fresh air.
17.SLEEP Button
(The clock must be corrected before setting sleep function)
Used to set sleep mode.
NOTE: 1.Cooling only air conditioner does not have the displays and functions related to heating.
2.HIGH/SO button This button is activated in Cooling/Heating mode, the fan speed is in AUTO mode after pressing it and "high functon" will be cancelled automatically after 15 minutes running.
18.FAN Button
Used to select fan speed:LOW,MID,HIGH,AUTO.
19.TIMER OFF Display
20.CLOCK Display
21.FILTER Display
22.TEMPERATURE Display
23.AUTO SWING Display
24.HIGH/SO Display
25.SIGNAL SENDING Display
26.FRESH AIR Display
27.ELECTRICAL HEATING Display
28.Some other buttons
All these functions are not available now.
29.HEALTH Display
Displays when healthy run function is set.
30.DEHUMIDIFICATION Display
31.Operation MODE Display
AUTO RUN
COOL RUN
DRY RUN
HEAT RUN
FAN RUN
32.SLEEP State Display
33.BATTERY Energy Display
Notify the user when it is time to change the batteries.
34.LOCK State Display
35.FAN SPEED Display
LO MID
The distance between the remote controller and the receiver should be max 7m and there should be no obstacle between them. Do not throw the remote controller; prevent it from being damaged.
When operating the remote controller in an area where electronically controlled lights are installed or wireless handsets are used, please move closer to the indoor unit as the function of the remote controller might be affected by signals emitted by the above mentioned equipments.
Battery loading
Battery loading Batteries are fitted as follows:
Remove the battery compartment lid Slightly press and disengage the battery compartment lid marked with ì
section and then remove the battery compartment lid by pressing in the direction of the arrow as shown in the figure above.
î and then hold the remote controller by the upper
Loading the battery
Ensure that batteries are correctly placed in the compartment as required for positive and negative terminals.
Replacing the battery compartment lid
The battery compartment lid is reinstalled in the reverse sequence.
Display review
Press the button to see if batteries are properly fitted. If no display appears, refit the batteries.
Confirmation indicator
If no indication is displayed after press ON/OFF button, reload the batteries.
Caution:
* *
* *
HI
AUTO
AUTO
If the remote controller does not operate as designed after fitting new batteries of the same type, press the Reset button (marked ) with a pointed article.
Note:
36.TIMER ON Display
Remote Controller' Operation
When in use, direct signal transmission head to the receiver placed on the indoor unit
It is recommended that the batteries be removed from the compartment if the remote controller is not used for an extended period. The remote controller is programmed for automatic test of operation mode after the batteries are replaced. When the test is conducted, all icons will appear on the screen and then disappear if the batteries are properly fitted.
Clock Set
When unit is started for the first time and after replacing batteries in remote controller, clock should be adjusted as follows:
1.Press CLOCK button, clock indication of " AM " or " PM " flashes.
2.Press or to set correct time. Each press will increase or decrease 1 min. If the button is kept pressed, time will increase or decrease quickly.
3.After time setting is confirmed, press "SET" : AM or PM stop flashing, while clock starts working. Note:AM means morning and PM means afternoon.
1
RESET
HEALTH
CLOCK
TIMER
FILTER
CODE
FRESH
2
LIGHT
SLEEPMODE
SET
HIGH/SO
LOCK
3
Fan Operation
1.Unit start
Press ON/OFF button to start your air conditioner. Previous operation status appears on LCD (except for TIMER, SLEEP, and SWING setting).
2.Select operating mode
Press MODE button. At each press, operation mode changes as follows:
A
SWING
MODE
HEALTH
2
CLOCK
TIMER
FILTER
RESET
4
CODE
A U T O
TEMP
ON
OFF
FRESH
1
LIGHT
FAN
SLEEP
SET
HIGH/SO
LOCK
AUTO
FANHEATCOOL DRY
Then select FAN
3. Adjust fan speed
Press FAN button. At each press, fan speed changes as
3
follows:
LOW
MID
HIGH
Air conditioner will run at the selected fan speed. When in AUTO mode, unit will adjust fan speed according to room temperature automatically.
4. Unit stop
Press ON/OFF button to stop unit.
About FAN mode When the air conditioner runs in F AN mode, it is not possible to select AUTO FAN or to set temperature.
AUTO, COOL , HEAT and DRY Operation
3
SWING
MODE
HEALTH
2
CLOCK
TIMER
FILTER
RESET
5
CODE
A U T O
TEMP
ON
OFF
FRESH
LIGHT
1
SLEEP
HIGH/SO
SET
LOCK
A
FAN
4
1. Unit start
Press ON/OFF button,unit starts. Previous operation status appears on LCD (except for TIMER, SLEEP and SWING setting)
2.Select operation mode
Press MODE button. At each press, operation mode changes as follows:
3
AUTO
FANHEATCOOL DRY
Then select AUTO run or select COOL operation or select DRY operation or select HEAT operation
3.T emperature setting
Press TEMP button. Every time the button is pressed, temp. setting increases
1 C; if the button is kept pressed, temp. setting will increase quickly .
Every time the button is pressed, temp. setting decreases 1 C, if the button is kept pressed, temp. setting will decrease quickly .
Set proper temperature
4.Adjust FAN button
Press F AN button. At each press, fan speed changes as follows:
A U T O
COOL operation starts when room temp.is higher than temp. setting.
Temp. setting +2 C
Temp.setting
Ultra-low air flow
On reaching temp.setting +2 C, unit will run in mild DRY mode.
AUTO
Air conditioner will run at the selected fan speed.
5. Unit stop
Press ON/OFF button,unit stops.
LOW
In ATUO mode, the temperature setting is not displayed on LCD. In this mode, during running air conditioner will select COOL, HEAT or FAN mode automatically according to the room temperature. In DRY mode, when room temperature becomes 2 C higher than temperature setting, unit will run intermittently at LOW speed regardless of FAN setting. When room temperature is lower than temperature setting, unit will only run F AN operation. In HEAT mode,warm air will blow out after a short period of time due to cold-draft prevention function.
MID HIGH
Adjusting air flow direction
AUTO SWING
Press SWING button. Up and down airflow varies upwards and downwards. Left and right airflow varies left and right sides.
A
A U T O
TEMP
ON
SWING
OFF
MODE
FAN
SLEEP
AUTO SWING
When the automatic swing louver moves to the proper angle, press SWING button can fix the airflow direction.
Always use SWING button on the remote controller to adjust flaps. Adjusting them by hand may result in air conditioner's abnormally running.
In COOL or DRY mode, do not leave the louver in downward position for a long time, as the water vapor close to the grille may condense and water may drop from the air conditioner.
Please carefully set temperature when children, old or infirm people ues the air conditioner.
FRESH
HEALTH
LIGHT
SET
HIGH/SO
LOCK
In case of great humidity, If the vertical flaps are completely turned towards left or right, the louver will drop water.
Never adjust the louver directly by hand, as this
CLOCK
TIMER
FILTER
RESET
CODE
could make it work abnormally .If the louver work abnormally , stop unit, restart and adjust the louver by remote controller.
After unit stops:
Displays on the LCD disappear. All indicators on the indoor unit go out. Swing louver automatically close the air outlet.
Hints:
As in COOL mode air flows downwards, adjusting airflow horizontally will be much more helpful for a better air circulation As in HEAT mode air flows upwards, adjusting airflow downward will be much more helpful for a better air circulation. Be careful not to catch a cold when cold air blows downward directly.
Sleep Function
Before going to bed you can press down the SLEEP button and the air conditioner will run so as to make you sleep more comfortably. Before using this function, the clock must be set.
Use of SLEEP function
After the unit's start, set running mode and then press SLEEP button once to make the air conditioner have the previous-set sleep time (first power-on is "1h"). The sleep symbol will appear. Press time button / : you can choose the time in 1~8 hours. Each time the button is pressed, the time increases/decreases 1 hour: "xh" and "OFF" indications appear on the display.
Operation Mode
1.In COOL, DRY mode
One hour after sleeping operation start, the temperature is 1 C higher than the setting one. After another hour, temperature rises 1 C: sleep run continuously for another 6 hours and then stops. The actual temperature is higher than the setting one which is to prevent from being too cold to your sleep.
2.In HEAT mode
One hour after sleeping operation start, the temperature is 2 C lower than the setting one. After another hour, temperature decreases by 2 C more. Temperature will automatically rise by 1 C after another 3 hours' continuous operation. The actual temperature is lower than the setting one which is to prevent from being too hot to your sleep.
3.In AUTO mode.
The air conditioner will run in corresponding sleep operation according to the automatically selected operation mode.
SLEEP RUN BEGINS
1 hrs
SETTING T
In COOL,DRY mode
SETTING T
1 hrs
1 hrs
SLEEP RUN BEGINS
In HEAT mode
SLEEP RUN STOPS
about 6 hrs
increase 1 C
increase 1 C
decrease 2 C
decrease 2 C
about 6 hrs
3 hrs
SLEEP RUN STOPS
SHUT DOWN
SHUT DOWN
increase 1 C
Notes:
After setting SLEEP function, it is not possible to set clock. If set-sleep time does not reach 8 hours, unit will automatically stop operation
after set time is reached. Set " TIMER ON " or " TIMER OFF "In COOL,DRY mode function first,
then set SLEEP. After set SLEEP function, the TIMER function cannot be set.
SWING
RESET
MODE
HEALTH
CLOCK
TIMER
FILTER
A
A U T O
OFF
TEMP
ON
OFF
FAN
SLEEP
FRESH
SET
HIGH/SO
LOCK
LIGHT
CODE
Timer ON/OFF Function
Set clock correctly before starting TIMER operation
1.Unit start
A
After unit start, select your desired operation mode (operation mode will be displayed on LCD)
2.TIMER mode selection
Press TIMER button on the remote controller to change TIMER mode. Every time the button is pressed, display of TIMER mode changes as follows:
SWING
MODE
HEALTH
CLOCK
TIMER
2
FILTER
RESET
CODE
TEMP
ON
OFF
FRESH
LIGHT
1
3
FAN
SLEEP
SET
HIGH/SO
LOCK
ON OFF ON OFF
AM
12:00
TIMER ON
PM
12:00
TIMER OFF
AM
12:00
TIMER ON-OFF
PM
12:00
blank
Then select TIMER mode as needed (TIMER ON or TIMER OFF). Now or will flash.
ON
OFF
3.TIMER setting (press time adjust buttons )
Every time the button is pressed, time increases 10 minuts. If the button is kept pressed, time changes quickly.
4
Every time the button is pressed, time decreases 10 minuts. If the button is kept pressed, time changes quickly. It can be adjusted within 24 hours at will.
4.Confirm setting
After setting correct time, press SET button to confirm time. Now
or stop flashing.
ON
OFF
Time displayed: unit starts or stops at X hour X min (TIMER ON or TIMER OFF)
5.Cancel TIMER mode
Just press TIMER button several times until TIMER mode disappears.
Hints:
After replacing batteries or if a power failure occurs, TIMER setting must be reset.
Remote controller has memory function. When you use TIMER mode next time, just press SET button after mode selection if timer setting is the same as the previous one.
Note:
After setting TIMER function, the remote controller displays TIMER time. If you want to see clock time, just press CLOCK button once: clock time will be displayed (if you press the button again continuously ,you can adjust clock). 5 seconds later, the display will show TIMER time again.
Timer ON-OFF Function
Set clock correctly before starting TIMER operation
1.Unit start
After unit start, select your desired operation mode (operation mode will be displayed on LCD)
SWING
2
MODE
HEALTH
CLOCK
TIMER
FILTER
4
RESET
5
CODE
OFF
TEMP
ON
OFF
FRESH
LIGHT
1
3
A
FAN
SLEEP
SET
HIGH/SO
LOCK
2.TIMER mode selection
Press TIMER button on the remote controller to change TIMER mode. Every time the button is pressed, display of TIMER mode changes as follows:
ON
AM
12:00
TIMER ON
OFF
PM
12:00
TIMER OFF
AM
ON
12:00
Then select TIMER ON-OFF mode.
OFF
PM
12:00
TIMER ON-OFF
ON
will flash.
blank
3.Time setting for TIMER ON
Press time button
Every time the button is pressed, time increases 10 minuts. If the button is kept pressed, time will changes quickly.
Every time the button is pressed, time decreases 10 minuts.
6
If the button is kept pressed ,time will changes quickly. It can be adjusted within 24 hours at will. AM refers to morning and PM refers to afternoon.
4.Timer confirming for TIMER ON
After setting correct time, press TIMER button to confirm time. Now
stops to flash, while
ON
starts flashing.
OFF
Time displayed : unit starts at X hour X min.
5.Timer setting for TIMER OFF
Press time buttons and follow the same procedures in " Time setting for TIMER ON"
6.Time confirming for TIMER OFF
After time setting, press SET button to confirm time. Time displayed: unit starts at X hour X min.
stops to flash.
OFF
7.Canel TIMER mode
Just press TIMER button several times until TIMER mode disappears. According to the time setting sequence of TIMER ON and TIMER OFF,
either start-stops or stops-start can be realized. If the time setting of TIMER ON is the same as TIMER OFF, TIMER
ON-OFF function cannot be set.
Filter Up/Down
(Only for AB182ACBEA)
A
After the air conditioner has operated for a certain period, dust has accumulated on the filter, and the filter up/down function can be used to clean it.
1.Whether unit starts or stops, continuously press FILTER button for 3 seconds, and enter the filter up/down waiting status (when unit stops, the yellow TIMER indicator flashes, and filter and clock indication are displayed on the remote controller . Only the FILTER button, the temperature buttons " " " " and time buttons are active).
SWING
MODE
HEALTH
CLOCK
TIMER
FILTER
RESET
CODE
1
TEMP
ON
OFF
FRESH
LIGHT
FAN
SLEEP
SET
HIGH/SO
LOCK
2.Press temperature button or time button in filter
" "
" "
up/down waiting status: the up/down mechanism makes the filter moving downward and does not stop until it has reached the maximum limit.
3.Press temperature button or time button in filter
" "
" "
up/down waiting status: the up/down mechanism makes the filter to moving upward till near the surface board and then automatically adjusts it to reset (when adjusting to reset, it will not be controlled by the remote controller till the adju­ stment is finished).
4.During moving downward, press temperature button or time button: moving stops.
" "
5.During moving downward, press temperature button or time button: moving stops.
" "
" "
" "
6.Continuously press FILTER button 3 seconds again to cancel the filter up/down waiting mode (unit stops, the yellow timer indicator stops flashing, the filter goes back to the original position, the remote controller goes back to off status and only clock is displayed).
Note: If the filter does not thoroughly go back to the original position, only needs to operate several times repeatedly.
" High mode " Operation
A
A U T O
TEMP
ON
SWING
MODE
HEALTH
OFF
FRESH
FAN
SLEEP
Outline of operation in "High Mode"
This function is suitable when the set temperature must be reached in the shortest delay. The button "HIGH/SO", referred to this function, is effective in Cooling/Heating mode (not in Auto/Dry/Fan modes).
ON
Press the HIGH/SO button noce
The indication appears on the display of the remote controller and operation in "High Mode" starts. The AUTO fan speed is automatically set and the corresponding indication is also displayed.
LIGHT
SET
HIGH/SO
1
LOCK
OFF
CLOCK
TIMER
FILTER
RESET
CODE
Press the HIGH/SO button twice
If the button is pressed once, the indication is displayed on the remote controller. If you press the button once again, the indication disappears, regular operation is restored and fan speed goes back to the mode set before "High Mode" operation.
NOTICE: When the air conditioner is operating in " High Mode " , unevenness of room air temperature may occur due to the intensive operation in a short time. Anyway, operation in "High Mode", does not last for more than 15 minutes, then regular operation is automatically restored.
" Soft mode " Operation
A
A U T O
OFF
TEMP
ON
SWING
MODE
HEALTH
CLOCK
TIMER
OFF
FRESH
FAN
SLEEP
SET
HIGH/SO
Outline of operation in "Soft Mode"
Operation in "Soft Mode", more silent, is suitable when noises should be reduced, e.g.. for reading or sleeping. The button "HIGH/SO", referred to this operation, is effective in Cooling/Heating mode (not in Auto/Dry/Fan modes).
ON
Press the HIGH/SO button twice
The indication appears on the display of the remote controller and operation in "Soft Mode" starts. The AUTO fan speed is automatically set and the corresponding indication is also displayed.
FILTER
RESET
CODE
LIGHT
1
LOCK
OFF
Press the HIGH/SO button twice
If the button is pressed once, the indication is disappears from the remote controller's display. If you press the button once again, regular operation is restored and fan speed goes back to the mode set before "Soft Mode" operation.
NOTICE: When the air conditioner is operating in " High Mode " , unevenness of room air temperature may occur due to the intensive operation in a short time. Anyway, operation in "High Mode", does not last for more than 15 minutes, then regular operation is automatically restored.
AIR FLOW DIRECTION ADJUSTMENT PROCEDURE-Cassette type
Adjusting up/down air flow direction
Up/down direction can be adjusted by using the SWING button on the remote controller. Each time pressing this button, the mode changes in the following sequence.
SWING
Change to the AIRFLOW mode.
SWING
Louver moves in upward and downward directions continuously.
No indication (louver stopped)
LOUVER STOPPED
When the LOUVER button is pushed during SWING mode, it stops swinging at the just angle.
CAUTION
Avoid direct air flow to the body for many hours. Avoid downward blowing operation of cooling mode for many hours. Do not touch the swing louver during swing operation.
AIR FLOW DIRECTION ADJUSTMENT PROCEDURE-Convertible type
Adjusting up/down air flow direction
Up/down direction can be adjusted by using the SWING button on the remote controller. Each time pressing this button, the mode changes in the following sequence.
Change to the AIRFLOW mode.
SWING
Louver moves in upward and downward directions continuously.
CAUTION
Avoid direct air flow to the body for many hours. Avoid downward blowing opera­tion of cooling mode for many hours. Do not touch the swing louver during swing operation.
SWING
No indication (louver stopped)
LOUVER STOPPED
When the LOUVER button is pushed during SWING mode, it stops swinging at the just angle.
Recommendable stopping angle of the louver
COOL and DRY
(Horizontal Blowing)
HEAT
(Downward Blowing)
Wired controller functions:
Buttons and functions of the wired controller
CLOCK
Used to adjust time.
TIMER
Used to set timer mode.
CHECK
Auto-diagnostic button.
+ -
stands for time plus/minus, used to adjust time.
FILTER
Filter-cleaned button.
MODE
Used for select indoor operation mode.
FAN SPEED
Used for select indoor air flow.
SWING
Used for setting indoor swing mode.
HEALTH
HEALTH
C
F
SET RECOVERY
CHECK
Used for setting indoor health function.
TEMP + -
Used for changing set temperature.
RECOVERY
used to switch over air­exchanging mode.
POWER ON/OFF
Used for unit start and stop.
Cautions: On cooling only unit, heating mode is not available.
RESET
Reset correct mode button.
Note: The above information is the explanation of the displayed information therefore varies with those displayed in actual operation.
Buttons function MODEused for select indoor operation mode. FAN:used for select indoor air flow. SWINGused for setting indoor swing mode. HEALTHused for setting indoor health function. TEMP + -used for changing set temperature.
CLOCKused to adjust time.
+-stands for time plus/minus, used to adjust time.
TIMERused to set timer mode.
RECOVERYused to switch over air-exchanging mode.
CHECKauto-diagnostic button.
FILTERfilter-cleaned button.
RESETreset correct mode button.
Display description
[MODE] [AUTO]auto operation mode [MODE] [FAN ONLY]air-throwing mode [MODE] [COOL]Cooling operation mode [MODE] [DRY]Dehumidification mode [MODE] [HEAT]Heating operation mode [MODE] [HEAT] [TES]In heating mode, auxiliary electric heater is running. Only when the unit
with auxiliary electric heater is in auxiliary electric heating mode, it will display.
[FAN] [AUTO]auto fan running
Loading...
+ 102 hidden pages