Haier AU142AFBBA user guide manual

No.0010570833 C
CASSETTE AIR CONDITIONER
Operation Manual
AB142ACMAA AU142AFMAA (HBU-14C03) AB142ACAAA AU142AFABA (HBU-14H03) AB142ACNAA AU142AFNBA (HBU-14CA03/R1) AB142ACBAA AU142AFBBA (HBU-14HA03/R1)
Please read this manual carefully before using the air conditioner Please keep this manual properly for future use
051128*23*******
Contents
Cautions
...........................................................................................
Main points of operation
..................................................................
Name of Each part
..........................................................................
Safety cautions
................................................................................
Gaide to operation
........................................................................
Maintenance
.....................................................................................
Trouble shooting
..........................................................................
When trouble happens
.....................................................................
Customer Need to know
.................................................................
Installation Tools
..............................................................................
Installation Procedures
................................................................
Installation Procedures,Check and Test Run
....................................
Air Purging Method ( To use vacuum pump) ....................................
1-2 3-4 5-7 8-9
10-16
17
18-20
21 22 23
24-31
32 33
CAUTIONS
1
For the purpose of safety, the air conditioner must be properly grounded in accordance with specifications.
Always remember to unplug the air conditioner before opening inlet grill. Never unplug your air conditioner by pulling on the power cord. Always grip plug firmly and pull straight out from the outlet.
Damaged air conditioners are not to be put into operation. In case of doubt, consult your supplier.
Use of the air conditioner is to be carried out in strict compliance with the relative instructions set forth in the User's Guide.
Installation shall be done by professional people, don't install unit by yourself.
Disposal of the old air conditioner
Before disposing an old air conditioner that goes out of use, please make sure it's inoperative and safe. Unplug the air conditioner in order to avoid the risk of child entrapment.
It must be noticed that air conditioner system contains refrigerants, which require specialized waste disposal. The valuable materials contained in a air conditioner can be recycled. Contact your local waste disposal center for proper disposal of an old air conditioner and contact your local authority or your dealer if you have any question. Please ensure that the pipework of your air conditioner does not get damaged prior to being picked up by the relevant waste disposal center, and contribute to environmental awareness by insisting on an
Disposal of the packaging of your new air conditioner
All the packaging materials employed in the package of your new air conditioner may be disposed without any danger to the environment.
The cardboard box may be broken or cut into smaller pieces and given to a waste paper disposal service. The wrapping bag made of polyethylene and the polyethylene foam pads contain no fluorochloric hydrocarbon.
Consult your local authorities for the name and address of the waste materials collecting centers and waste paper disposal services nearest to your house.
Safety Instructions and Warnings
Before starting the air conditioner, read the information given in the User's Guide carefully. The User's Guide contains very important observations relating to the assembly, operation and maintenance of the air conditioner.
The manufacturer does not accept responsibility for any damages that may arise due to non-observation of the following instruction.
All these valuable materials may be taken to a waste collecting center and used again after adequate recycling.
2
All electrical repairs must be carried out by qualified electricians. Inadequate repairs may result in a major source of danger for the user of the air conditoiner.
Do not damage any parts of the air conditioner that carry refrigerant by piercing or perforating the air conditioner's tubes with sharp or pointed items, crushing or twisting any tubes, or scraping the coatings off the surfaces. If the refrigerant spurts out and gets into eyes, it may result in serious eye injuries.
Do not obstruct or cover the ventilation grille of the air conditioner. Do not put fingers or any other things into the inlet/outlet and swing louver.
Do not allow children to play with the air conditioner. In no case should children be allowed to sit on the outdoor unit.
Specifications
The refrigerating circuit is leak-proof.
1. Applicable ambient temperature range:
The machine is adaptive in following situation
Cooling
Heating
Indoor
Maximum: Minimum:
D.B / W.B D.B /
D.B
Outdoor
Maximum: Minimum:
D.B
D.B
Indoor
Maximum: Minimum:
D.B
Outdoor
Maximum: Minimum:
43 C/ 26 C
D.B / W.B 24 C/ 18 C
20 C
27 C
15 C
18 C/ 14 C
32 C/ 23 C
2. If the supply cord is damaged, it must be replaced by the manufacturer or its service agent or a similar qualified person.
3. If the fuse on PC board is broken please change it with the type of T. 3.15A /250V AC.
CAUTIONS
4. The wiring method should be in line with the local wiring standard.
5. All the cables shall have got the European authentication certificate.
6.The waste battery shall be disposed properly .
7.The indoor unit installation height is at least
2.5m.
8.The appliance must be installation that the plug should be easily accessible after installation.
9. The power plug should be self-provided and it should have got the European authentication certificate.
D.B / W.B -7 C/ -8 C
3
Main points of Operation
Operation of Air Conditioner
When the environmental humidity is great, water maybe dripped from the air outlet in cooling or drying mode.
3-minute Protection Function
If restart the unit immediately after stopping, the compressor will start only 3 minutes later to protect the machine.
Variation of Fan Speed
If fan speed in auto mode, it will automatically lower when the room temperature close to the setting temperature in cooling mode.
In heating mode,the compressor stops when the room temperature at setting temperature and fan turns into low speed or stops.
In Dry mode,fan speed will be automatically varied.
Remote Control:
There is a telecommunication interface for remote control on the control panel of the indoor unit. After the peripheral equipment have been installed in accordance with the instruction manual of the selected remote control detector, the air conditioner will be computerized and controlled from a far­away place.
4
Main points of Operation
Prevent Cool Air Blowing Off
In heating mode,the indoor fan will not run immediately after the unit starts to prevent the cool air blowing off.
Defrosting Function
In heating mode, when frost formed on the outdoor heat exchanger, the air conditioner will automatically defrost a few minutes. During defrosting, both indoor and outdoor fan will stop running. When defrosting finished, air condi­tioner will automatically back to running.
Hints
The air conditioner absorbs heat form outside and releases inside when in heating mode, therefore the outside environmental temperature will affect heating effects.
Power Failure Compensation(to be applied for a necessary situation):
After the power failure compensation is set, if power failure suddenly occurs while the air conditioner is working,it will resume the previous working state when the power is supplied again.
Setting Method: When the remote controller is on (excluding timer mode and fan mode),press the “sleeping” button on the remote controller 10 times within 5 seconds,and after the buzzer rings 4 times,the air conditioner will enter the state of power failure compenstation.
Cancel Method:Press the “sleeping” button on the remote controller 10 times within 5 seconds, and after the buzzer rings 2 timer,the power failure compensation mode will be cancelled.
Note: When a power failure suddenly occurs during the air conditioner si working after the power after the power failure compensationis set,if the air conditioner will not be used for a long time, please cut off the power supply to prevent its operation from being res­ umed after the power is supplied again, or press the “ Switch On/Off ” button after the power comes again.
Wait a minute
Defrosting Running
5
Indoor unit
Swing louver
(Air flow direction can be adjusted by using the SWING button on the remote controller)
Electrical Components Case
Air Inlet Grille
Air Filter
(Inside of the Inlet Grille)
Air Outlet (blow out hot air when cooling and cool air when heating)
Air Inlet (back)
Conneting pipe and electrical wiring
Name of Each Part
outdoor unit
Air Inlet (side)
5
Name of Each Part
Remote controller
1.TEMP Setting Button
(Used to set temperature, setting ranges: 16 C to 30 C)
In Up/Down function,for controlling up and down filter.
2.SWING Button
Press once auto swing, press again the swing louver fixed on the present swing position.
3.Power ON/OFF Button (used for unit
start and stop) After power on, the LCD of remote contr-
oller will display the previous operation state (except for TIMER,SLEEP and SW­ING state).
4.Operation MODE
Used to select operation mode. Every time press MODE button,operation mode
changes according ot hte following order:
5.CLOCK Button
Used to set correct time.
AUTO
FAN
HEAT
COOL
DRY
6.TIMER Button
Used to select TIMER mode:TIMER ON,TIMER OFF, TIMER ON/OFF.
(Note: if time of TIMER ON is the same as TIMER OFF,TIMER ON/OFF cannot be set)
7.LOCK Button
8.RESET Button
Used to sharp article press this button can reset the remote controller back to normal condition when it in malfunction state.
9.Battery Loaded Indication
10.HOUR Adjustment
Used to set clock and timer setting
11.SLEEP Button
(The clock must be corrected before set sleep function)
Used to set sleep mode.
12.SET Button
Used to confirm TIMER and CLOCK settings.
13. FILTER Button
Used to set up/down function of filter.
14.FAN Button
Used to select fan speed:LOW,MID,HIGH,AUTO.
NOTE: 1.Single cooling air conditioner does not have the displays and functions related to heating.
2.This kind of unit does not have the following related functions and displays:
16
19
20
22
23
24
25
27
TEMP
SWING
FAN
MODE
ON
OFF
SLEEP
SET
FILTER
CLOCK
TIMER
LOCK
RESET
AUTO
OFFON
C
23
21
22
20 19 18
17 16
10
11
12
14
9
8
7
6
5
4
1
31
30
29
28
26
25
24
2
3
13
15
27
32
Used to lock operation button and LCD display contents: after press this button, other button are out of function, lock state display appears; press again,cancel lock state and lock state display disappeared.
7
Clock Set
Name of Each Part
Display when healthy run function is set.
15.TIMER OFF Display
16.HUMIDIFICATION Display
17.TEMPERATURE Display
18.LOCK State Display
19.BATTERY Energy Display
Display when in low battery to remind customer to change the battery
.
20.STRONG/QUITE Run Display
21.SIGNAL SENDING Display
22.NEW AIR Display
23.ELECTRICAL HEATING Display
24.HEALTH Display
25.SLEEP State Display
26.Operation MODE Display
AUTO RUN
COOL RUN
DRY RUN HEAT RUN
FAN RUN
27.COMFORTABLE RUN Display
28.FAN SPEED Display
29.AUTO SWING Display
30.TIMER Display
31.FILTER Display
32.TIMER ON Display
Remote Controller’ Operation
The distance between the signal transm­ission head and the receiver hole should be within 7m without any obstacle as well.
When unit is started for the first time and after replacing batteries in remote controller
, clock should be adjusted as follows:
1.Press CLOCK button,clock indication of “ AM “ or “PM” flashes.
2.Press or to set correct time,each press will increase or decrease 1 min. If the button is kept pressed, time will increase or d
ecrease quickly.
3.After time setting is confirmed,press “SET” , AM or PM stop flashing, while clock starts working.
Note:AM means morning and PM means afternoon.
Don’t throw the controller,prevent it from being damaged.
When in use, put the signal transmission head directly to the receiver hole on the indoor unit
When electronic-strated type fluorescent lamp or change-over type fluorescent lamp or wireless telephone is installed in the room, the receiver is apt to be disturbed in receiving the signals so the distance to the indoor unit should be shorter
.
Loading of the battery (load the batteries as illustrated)
Remove the battery cover
Load the battery
Put on the cover again
Installing the cover is opposite to removing it
Confirmation indicator
If no indication after press ON/OFF button,reload the batteries.
Note:
A
LO MID
HI
AUTO
Use two new same-typed batteries when loading. If the remote controller can’t run normally during
operation ,please remove the batteries and reload them few minutes later that will be ok
If the display of remote controller is faded(someti­mes run abnormally),which indicates no battery
,so
please change the batteries
Hint:
Remove the batteries in case unit will not be in usage for a long period.if there is any display after taking-out just need to press reset button with a sharp article
First slightly press the position marked with and push down the cover
,then as shown in the figure:holding the upper part of the remote con­troller with the left hand and the right hand slightly grasps the battery box cover and forces on the arrow direction to remove the cover.
SLEEP
SET
TIMER
LOCK
RESET
MODE
FILTER
CLOCK
1
Be sure that the loading is in line with the “ + ” “ - ” pole request as illustrated on the botton of the box.
2
3
8
Safety Cautions
Below are listed four kinds of Safety Cautions and Suggestions:
Be sure to conform with the following important Safety Cautions. The Safety Cautions should be at hand so that they can be checked at any time when needed. If the air conditoner is transferred to the new user, this manual should be as well transferred to the new user.
Incorrect operations may result in severe consequences of death or serious injures.
WARNING:
Incorrect operations may result in injures or machine damages; in some cases may cause serious consequences.
CAUTION :
: It must be strictly prohibited where marked with “ Prohibited ”, otherwise may result in machine damages or endanger the user’personal safety.
This information can ensure the correct operation of the machine.
INSTRUCTION:
Carefully read the following information in order to operate the air conditioner correctly.
WARNING
If any abnormal phenomena are found (e.g. smell of firing),please cut off the power supply immediately, and contact the dealer to find out’ the handling method.
When need maintenance and repair,call dealer to handle it.
Don’t put figures or any other things into the inlet/outlet and swing louver while the conditi­oner is in operation
Call the dealer to take measures to prevent the refrigerant from leaking.
Switch off
In such case,to continue using the air conditioner will damage the conditioner,and may cause electrical shock or fire hazard.
Incorrect maintenance and repair may cause water leak, electrical shock and fire hazard.
Because the high-speed fan is very dangerous and may cause injures.
The leaked refrigerant over certain density may cause oxygen deficient.If the air conditioner is installed in a small room be sure to take measure in order to prevent suffocation accident even in case of refrigerant leakage
When air conditioner is removed and reinstalled dealer should be responsible for them.
Incorrect installation may cause water leaking, electrical shock and fire hazard.
Don’t dismantle the outlet of the outdoor unit.
The exposure of fan is very dangerous witch may harm human beings.
After a long time use of air conditioner the base should be checked for any damages.
If the damaged base is not repaired, the unit may fall down and cause accidents.
9
Safety Cautions
WARNING
No goods or nobody is permitted to be placed on or stand on outdoor unit.
Don’t clean air conditioner with water.
The falling of goods and people may cause accidents.
Don't operate the air conditioner with damp hands.
Otherwise will be shocked.
Only use correct type fuse.
May not use wire or any other materials replacing fuse,othe­rwise may cause faults or fire accidents.
Don’t place any burning unit in the airflow of air conditioner,which may cause incomplete combustion
No inflammable spray fluid should be permitted to be placed or used near to air conditioner,otherwise may cause fire accident.
Air conditioner should be cleaned only after power supply is cut off to keep from shock or hurt.
Otherwise may cause shock.
Connect earthing wire.
Earthing wire should not be connected to the gas pipe, water pipe,lightning rod or phone line,incorrect earthing may cause shock.
Use discharge pipe correctly to ensure efficient discharge.
In correct pipe usage may cause water leaking.
Air conditioner can’t be be installed in the environment with inflammable gases.
The inflammable gases near to air conditioner may cause fire hazard.
Installed electrical-leaking circuit breaker.
When use the fumigating insecticide don’t operate air conditioner.
Otherwise the poisonous chemicals may settle in air conditioner, which harm the health of chemical-allergic people.
It easily causes electrical shock without circuit breaker.
Not permitted when running
10
Guide to Operation
Fan Operation
1.Unit start
Press ON/OFF button, unit starts. Previous operation status appears on LCD (except for TIMER ,SLEEP
, and SWING setting).
2.Select operation mode
Press MODE button. For each press,operation mode changes as follows:
3. Adjust fan speed
Press FAN button.For each press,fan speed changes as follows:
Air conditioner will run at the selected fan speed. When in
AUTO mode,unit will adjust fan speed
according to room temperature automatically.
4. Unit stop
Press ON/OFF button,unit stops.
AUTO FANHEAT
COOL
DRY
Then select FAN
About FAN Operation
F
AN operation refers that the air conditioner only run FAN,no COOL and HEAT operation,and in this status the unit can’t operate AUT O FAN as well no temperature settings.
LOW
MID
HIGH
TEMP
SWING
FA
MODE
ON
OFF
SLEEP
SET
FILTER
CLOCK
TIMER
LOCK
RESET
4
1
3
2
11
Guide to Operation
AUTO run, COOL , HEAT and DRY Operation
1. Unit start
Press ON/OFF button,unit starts. Previous operation status appears on LCD (except for TIMER,SLEEP
and SWING setting)
3.Temperature setting
Then select AUTO run or select COOL operation or select DR
Y operation or select HEAT operation
3
3
2.Select operation mode
Press MODE button. For each press,operation mode changes as follows:
Press TEMP button. Every time the button is pressed, temp. setting increases
1 C, if the button is kept pressed, temp. setting will increase quickly .
Every time the button is pressed, temp. setting decreases 1 C, if the button is kept pressed, temp. setting will decrease quickly
.
Set proper temperature
4.Adjust F AN button
Press FAN button .For each press, fan speed changes as follows:
Air conditioner will run at the selected fan speed.
5. Unit stop
Press ON/OFF button,unit stops.
In ATUO mode,the temperature setting is not displayed on LCD.In this mode,during running air conditioner will select COOL
,HEA T or FAN mode automatically according to the room temperature. In DRY mode,when room temperature becomes 2 C higher than temperature setting, unit will run intermittently at LOW speed regardless of FAN setting,When room temperature is lower than temperature setting,unit will only run FAN operation. In HEA T mode,warm air will blow out after a short period of time due to cold-draft prevention function,
TEMP
SWIN
FA
MODE
ON
OF
SLEEP
SET
FILTER
CLOCK
TIMER
LOCK
RESET
5
1
4
AUTO
FANHEATCOOL DRY
C
AUTO
AUTO
LOW
MID HIGH
T emp. setting +2 C T emp.setting
On reaching temp.setting +2 C, unit will run in mild DR
Y mode.
Ultra-low air flow
COOL operation starts when room temp.is higher than temp. setting.
2
12
Guide to Operation
Press SWING button. Up and down airflow vary upwards and downwards.Left and right airflow vary left and right sides.
Always use SWING button on the remote controller to adjust louver or flaps because if adjust it by hand may result in air condi­tioner running abnormally
.
Displays on the LCD disappear. All indicators on the indoor unit go out. Swing louver automatically close the air outlet.
After unit stops:
AUTO SWING
Air flow direction adjust
AUTO SWING
When the automatic swing louver moves to the proper angle,press SWING button can fix the airflow direction.
TEMP
WING
FAN
MODE
ON
OFF
SLEEP
SET
FILTER
CLOCK
TIMER
LOCK
RESET
Please carefully set temperature setting when infants,children,old people and patients use the air conditioner
.
In case of great humidity ,If the vertical flaps all towards left or right,the louver will drop water.
Don’t pull louver directly by hand which will make it work abnormally
.If the louver work abnormally,stop unit,restart and adjust by remote controller.
Hints:
As cold airflows downward in COOL
mode,adjusting airflow horizontally will be much more helpful for a better air circulation AS warm airflows upward in HEAT mode,adjusting airflow downward will be much more helpful for a better air circulation. Be careful not to catch a cold when cold air blows downward directly.
C
In COOL or DRY mode, the louver is not permitted to be in downwards position for a long time because the water vapor close to the grille may be condensed and the water may drop from the air conditioner
.
AUTO
13
Guide to Operation
Sleep Function
Before going to bed you can press down the SLEEP button and the air conditioner will run by the comfortable sleeping mode to make you sleep more comfortable. Before use this function, the clock must be corrected.
Usage of SLEEP function
After unit start,first set running mode and then press SLEEP button once.Mark the air conditioner have the previous-set sleep time(first power-on or after carrying out sleep function is 1h),the sleep symbol will appear. Press time button / , you can choose the time in 1~8 hours.Each time the button is pressed the time increases/decreases 1 hour and “ xh ” appears in the humidity setting part ,“ OFF ” appears in “ TIMER OFF ” display part and the sleep symbol disappears.
Operation Mode
1.In COOL, DRY mode
One hour after sleeping operation start, the temp. is 1 C higher than the setting one. After another hour the temp. rises 1 C and then run continuously for another 6 hrs and then close. The actual temp. is higher than the setting one which is to prevent from being too cool to your sleep.
2.In HEAT mode
One hour after sleeping operation start, the temp. decreases 2 C lower than the setting one. After another hour decreases by 2 C more. The temper­ature will automatically rise by 1 C after an other 3 hrs operation ,and then automatically close after 3 hrs continuous operation.The actual temperature is lower than the setting one which is to prevent from being too hot to your sleep.
3.In AUTO mode.
The air conditioner will run in corresponding sleep operation according to the automatically selected operation mode.
4.In FAN run
Can’t use SLEEP function.
SLEEP RUN BEGINS
SLEEP RUN STOPS
SETTING T
SHUT DOWN
about 6 hrs
1 hrs
In COOL,DRY mode
increase 1 C
increase 1 C
SLEEP RUN BEGINS
SLEEP RUN STOPS
SETTING T
SHUT DOWN
1 hrs
1 hrs
3 hrs
about 6 hrs
increase 1 C
decrease 2 C
decrease 2 C
OFF
TEMP
SWING
FAN
MODE
ON OFF
SLEEP
SET
FILTER
CLOCK
TIMER
LOCK
RESET
Note:
After setting SLEEP function ,it is forbidden to calibrate clock. If the set sleep-time does not reach 8 hours, unit will stop operation
automatically after set time is complete. Set “ TIMER OFF ”In COOL,DRY mode function first, then set SLEEP, unit
will perform sleep function. After set SLEEP function, the TIMER function cannot be set.
Set “ TIMER ON ”In COOL,DRY mode function first,then set SLEEP, the sleep function can only be set before TIMER ON time.
After setting SLEEP function,press CLOCK button to show the time; press TEMP button to show the temperature setting; press again to change the temperature.
In HEAT mode
14
Guide to Operation
Every time the button is pressed , time increases 10 minutes. If the button is kept pressed ,time will change quickly
.
Timer ON/OFF Function
Set clock correctly before starting TIMER operation
1.Unit start
After unit start ,select your desired operation mode(operation mode will be displayed on LCD)
2.TIMER mode selection
Press TIMER button on the remote controller to change TIMER mode.Every time the button is pressed,display of
TIMER mode
changes as follows:
ON OFF ON OFF
AM
12:00
AM
12:00
PM
12:00
PM
12:00
TIMER ON
TIMER OFF
TIMER ON-OFF
blank
Then select TIMER mode as needed (TIMER ON or TIMER OFF). And now or will flash.
3.TIMER setting (press time adjust button)
Every time the button is pressed , time decreases 10 minutes. If the button is kept pressed ,time will change quickly
.
It can be adjusted within 24 hours at will.
4.Confirm setting
After set correct time,press SET button to confirm time. And now
Time displayed: unit starts or stops at X hour X min (TIMER ON or TIMER OFF)
5.Cancel TIMER mode
Just press TIMER button several times until TIMER mode disappears
Hints:
After replacing batteries or a power failure happens,TIMER setting should be reset.
Remote controller possesses memory function,when use TIMER mode next time,just press SET
button after mode selection if timer
setting is the same as previous one.
Note:
After setting TIMER function,the remote controller displays TIMER time.If you want to see clock time, just press CLOCK button once it will display clock time (continuously press twice,you can adjust clock, see page 6 for details), and 5 seconds later it will back to
TIMER time.
1
ON
TEMP
SWING
FAN
MODE
ON
OFF
LEEP
SET
FILTER
CLOCK
TIMER
LOCK
RESET
2
3
4
C
ON
OFF
ON
OFF
or stops flash.
15
Guide to Operation
K
OFFON
Timer ON-OFF Function
Set clock correctly before starting TIMER operation
1.Unit start
After unit start ,select your desired operation mode(operation mode will be displayed on LCD)
2.TIMER mode selection
Press TIMER button on the remote controller to change TIMER mode.Every time the button is pressed,display of
TIMER mode
changes as follows:
OFF
3.Time setting for TIMER ON
4.Timer confirming for TIMER ON
After set correct time,press TIMER button to confirm time. And now
5.Timer setting for TIMER OFF
Press time button, and follow the same procedures in “ Time setting for
TIMER ON”
Press time button
ON
stops flash,while
starts flash
Time displayed : unit starts at X hour X min.
6.Time confirming for TIMER OFF
After time setting, press SET button to confirm time.
stops flash.
Time displayed : unit starts at X hour X min.
7.Canel TIMER mode
Just press TIMER button several times until TIMER mode disappears. According to the time setting sequence of TIMER ON or TIMER OFF,
either start-stops or stops-start can be realized. If the time setting of TIMER ON is the same as TIMER OFF, the TIMER
ON-OFF function cannot be set.
TEMP
SWING
FAN
MODE
ON
OFF
LEEP
SET
FILTER
CLOCK
TIMER
K
RESET
1
3
6
5
4
2
C
ON OFF ON OFF
AM
12:00
AM
12:00
PM
12:00
PM
12:00
TIMER ON
TIMER OFF
TIMER ON-OFF
blank
ON
Then select TIMER ON-OFF mode.
will flash.
Every time the button is pressed , time increases 10 minutes. If the button is kept pressed ,time will change quickly.
Every time the button is pressed , time decreases 10 minutes. If the button is kept pressed ,time will change quickly
. It can be adjusted within 24 hours at will.AM refers to morning and PM refers to afternoon.
OFF
16
Guide to Operation
After air conditioner operated for a period, dusts were gradually accumulated on the filter ,and the filter up/down function can be used to clean the filter
.
1.Whether unit start or stop, continuously press FILTER button 3 seconds,and enter into the filter up/down waiting status (when unit stops,the yellow
TIMER indicator flashes, filter and clock displayed on the remote controller and no others.Only the FILTER button and the temperature button and time button are active).
2.Press temperature button or time button in filter up/down waiting status, the up/down mechanism makes the filter to move downward and do not stop until reach the maximum limit.
3.Press temperature button or time button in filter up/down waiting status , the up/down mechanism makes the filter to move upward till near to the surface board and then automatically adjust to reset (when adjusting to reset, it will not be controlled by the remote controller till the adju­ stment is finished, and the remote controller can control again.
4.During moving downward ,press temperature button or time button, moving stops.
5.During moving downward ,press temperature button or time button, moving stops.
6.Continuously press FILTER button 3 seconds again to cancel the filter up/down waiting mode (unit stops, the yellow timer indicator stops flashing, the filter backs to the original position , the remote controller backs to of
f
status and only clock is displayed).
Note: If the filter does not thoroughly back to the original position,only need to operate several times repeatedly
.
TEMP
SWING
FAN
MODE
ON
OFF
SLEEP
SET
FILTER
CLOCK
T MER
LOCK
RESET
Filter Up/Down
“ ”
“ ”
“ ”
“ ”
“ ”
“ ”
“ ”
“ ”
“ ”
“ ”
“ ”
“ ”
1
17
Maintenance
Clean the unit
Turn off the power supply switch
Do not touch with wet hand.
Do not use hot water or volatile liquid
The 4 fixed bolts must be loosed as shown in the figure by arrow if they are bolts, the method is that: push the blots inward till to another edge. Generally the fixed blots are opened for inlet grille easily up and down as well cheaning the air filter.After open it,lower the inlet grille using remote controller, the maximum distance is 2.24m. Then turn the 1 rotated clamps 90 degree as shown in the figure, hold the air filter and nearly in the horizontal direction slightly pull it out.
Clean the air filter
Clean the air filter with water or vacuum cleaner. Use the detergent or neutral soapy water if the air filter is too dirty. Then rinse the air filter with water,and reinstall after drying.
Caution:
Do not clean the air filter with hot water over 40 C, otherwise may damage the filter.
Sweep the filter carefully.
Clean indoor (outdoor ) unit
Clean with hot wet cloth and neutral detergent, then wipe with dry cloth.Do not use too hot water (over 40 C) which may result in fading and deforming. Do not use insecticide and chemical washing agent.
Fixing nolt
Fixing nolt
Fixing nolt
Rotary fixing clamp
Outward drawable filter
ON
OFF
18
Troubleshooting
Seasonal Reserve
Operate the unit with FAN mode on a fair day for about half a day to dry the inside of the unit well.
Stop operation and turn off the power supply switch .Electric power is consumed even the air conditioner is in stop.
Clean the air filter, indoor unit and outdoor unit,and cover the unit with dustcoat.
Pre-season Care
See that there is no bostacles blocking the air inlet and air outlet of both indoor and outdoor unit to avoid reduce the working efficiency.
Be sure to install the air filter, ensure that the air filter is not dirty. Otherwise may result in machine damages or cause malfunciton due th dust inside the unit
To prevent compressor when start in HEAT mode, please cut in the power supply switch 12 hours before starting run,furthermore, always keep the power supply switch on during the using senson.
Post-season Care
19
Troubleshooting
The followings are not malfuncition
Hua
Hua
Water flowing sound is heard
When the air conditoner is started, when the compressor starts or stops during operation or when the air conditioner is stopped,it som­etimes sounds “ Bi- Bi-” or “Godo-Godo”. It is the flowing sound of the refrigerant , not a malfunction.
Cracking sound is heard
It smells.
This is caused by heat expansion or contra­ction of plastics
Air blown out from the indoor unit sometimes smells. The smell results from smells of furniture, paint , tobacco absorbed by indoor unit.
During operation, white fog comes out of indoor unit.
When in COOL or DRY mode, a thin water fog can be seen blown out of unit ,this is the condensed fog because the suddenly cooled indoor air is blown out.
Automatically switch into FAN mode during cooling.
To prevent frost from being accumulated on the indoor unit heat exchanger, it sometimes auto­matically switched into the FAN mode,but it will soon back to the cooling mode.
The air conditioner cannot be restarted soon after it stops. Air conditioner does not start?
This is because of the self-protection function of the system, therefore,it cannot be restarted for about three minutes after it stops.
Please wait for three minutes
20
ON
OFF
Troubleshooting
Air does not blow or the fan speed cannot be changed during drying.
In DRY mode, when room temperature becomes 2 C higher than temperature setting, unit rill run intermittently at LO speed regardless of F
AN setting
During heating,indoor fan is still running even unit is stopped.
To get ride of the excess heat, indoor fan will continue running for a while after unit autom­atically stops.
Water or vapor generated from the outdoor unit during heating.
This happens when the frost accumulated on the outdoor unit is removed (during defrosting operation).
Defrosting operation
Please check the following things about your air conditioner before making a service call.
Unit fails to start.
Is the power supply switch on ?
Power supply switch is not in ON position.
Is city supply power normal ?
Is the earth leakage breaker in action ?
Be sure to turn off the power supply switch immediately and contact the sales dealer
.
21
When trouble happens
Insufficient cooling or heating
The operation controller adjusted as required
Air filter too dirty ?
Horizontal swing louver upward ? (in HEAT mode)
Any obstacle exists at the air inlet or outlet?
Door or window left opened ?
Insufficient cooling
Any other heat sources in the room?
Sunlight direct into the room ?
Too crowed in the room ?
Cooled air blown out ( when heating)
When the air conditioner does not operate properly after you have checked the above-mentioned items or when following phenomenon is observed,stop the operation of the air conditioner and contact your sales dealer. The fuse or breaker often shuts down. Water drops off during cooling or drying operation. There is an irregularity in operation or abnormal sound that is audible.
22
Customer Need-to-know
Customer Need-to-know
Please install the air conditioner according to the requirements specified in this manual to ensure the air conditioner work well.
Be careful not to scratch the surface of the case during moving the air conditioner.
Please keep the installation manual for future reference when maintenance and changing installation place.
After installation ,please use the air conditioner according to the specification in the operation manual.
Using Directions
Adjust suitable airflow direction
Avoid direct sunlight and airflow
Keep the proper indoor temperature. Too cool or hot is not good for your health. Furthermore,it will result in excessive consumption of electric power.
Optimal temper­ature
Effectively use timer. Using TIMER mode, you can make the room
temperature reach a suitable temperature when you wake up or back home.
ATTENTION: after finishing installation,confirm no refrigerant leakage.
23
A
B
C
D
E
F
Installation tools
Standard accessories
1. Screw driver
2. Hacksaw
3. Drill with a diameter of 60mm
4. Inner hexagon spanner,shifting spanner
5. Spanner (14, 17, 19,24,27mm)
6. Pipe cutter
7. Pipe expander
8. Knife
9. Pincers
10. Leakage detector or soapy water
11. Band tape
12. Scraper
13. Refrigerant oil
The installation tools listed in the following sheet can be used as required.
The following parts mentioned in this manual are the installation accessories we prepared.
Symbol Parts Name
Adhesive tape
Pipe clamp
Connecting hose
Drainage hose
Non-hydroscopic heat insulating material
Gypsum powder
*********051128
Installation Tools
24
Installation of Outdoor Unit
Selection of installation place
Place strong enough to support unit weight, and will not cause vibration and noise. Place where discharged wind and noise do not cause nuisance to the neighbors, and is sufficiently
ventilated. Place where is less affected by rain or direct sunlight and sea breeze.
Place with enough space for smooth air flow. The unit cannot be installed on an unspecified metal frame (e.g. theft guard net).
It shall be not less than 2.5m high from the ground if the outdoor unit is installed close to a street.
Easy for maintenance.
Fixing the unit
Fix outdoor unit bracket to the wall using anchor bolt (M10). Fasten the outdoor unit onto the installation bracket with bolt (M10) and nut ,and keep it horizontal. If installation on the wall or on top of a roof, bracket shoukd be fixed securely to resist earthquake or storms. Be sure to use rubber pad during installation against unit vibration. Install the unit in such a way that the angle of inclination is lees than 3 degrees.
Installation dimension of outdoor unit (mm)
140 500 140
256
Installation Procedures
25
1.Selection of Installation Place
(1) Place above the ceiling where have enough space to arrange the unit. (2) Place where the drainage pipe can be arranged well. (3) Place where inlet and outlet air of indoor and outdoor unit will not be blocked.
(4) Do not expose the unit to the place with heavy oil or moisture (e.g.kitchen and workshop). (5) Do not set the unit in the place where destructive gas (such as sulfuric acid gas) or pungent
gas (thinner and gasoline) concentrates and retains. (6) Place strong enough to support the unit weight.
(7) No expensive articles such as television and piano below indoor unit. (8) Enough space for maintenance.
(9) Place more than 1m away from television and radio to avoid disturbing television and radio. (10) Easy for maintenance.
1.5m
2.5m Over
1.5m
0.31m
H
Air outlet
Air outlet
Air inlet
2.Installation Preparation
(1) Position of ceiling opening between unit and suspending bolt (front view of unit).
(2) Prepare all piping (refrigerant,water drainage )and wires (connection wire of remote controller, indoor unit connection wires) to the indoor unit before installation in order to connect indoor unit immediately after installation.
Ornament panel 630mm
ceiling opening 600mm
Indoor unit 570mm
Distance between
Indoor unit 570mm
Ceiling opening 600mm
Ornament panel 630mm
suspending bolts 460mm
210mm
335mm
35mm
Overlap between ceiling and ornament panel shall be 15mm
Suspending bolts
Ceiling
Ornament panel
Installation Procedudres
26
(3) Install a suspending bolt To support the unit weight ,anchor bolt should be used in the case of
already exists ceiling. Fow new ceiling, use flush-in type bolt, built-in type bolt or parts pretared in the field. Before going on installing, adjust space to ceiling.
Installation of indoor unit
In case of no ceiling
Install unit temporally Put suspending bracket on the suspending bolt to hang the unit up. Be sure to use nut and
washer at both end of the breaket to secure firmly.
After installation on the ceiling
(1) Adjust unit to its right position (Refer to preparation for installation-(1)) (2)Check that unit is horzontal.
Put suspending bracket on the suspending bolt to hang the unit up.Be sure to use nut and washer at both end of the bracket to secure it firmly.
Water pump and floating switch is installed inside indoor unit,check four corners of the unit for its lever using horizontal comparator or PVC tube with water.(If unit is tilting against the direction of water drainage,problem may occur on floating water leakage.)
In the case of ceiling already exists
(1)Install unit temporally
(2)Adjust the height and position of the unit. (3)Proceed with procedure (4) of “ In the case of no ceiling “
Nut (Prepare in feild)
Washer (Prepared in feild)
Suspending bolts
Fasten (double nuts)
Insert
Washer fixing pad
(prepared in feild)
[ secure the washer firmly]
leveler
Polythene pipe
50*150mm
Ceiling
Roof
Anchor bolt
Long nut or thread
Suspending bilt M10
Note: All the above mentioned parts shall be prepared in feild, the diameter of suspending bolt is M10
<Installation Example>
Installation Procedures
27
Large size seal pad
4mm below
Cli
3.Installation of water drainage pipe
(1) Install water drainage pipe
Pipe diameter shall be equal or larger than that of connecting pipe (Pipe of polythene; size: 25mm; O.D.: 32mm )
Drainpipe should be short, with a downward slope at least 1/100 to prevent air bag from forming.
If downward slope of drainpipe cannot be made,lifting pipe shall be installed. Keep a distance of 1-1.5m between suspending bolts, to make water hose straight.
Use the drainage hose and clip provided with unit. Insert water pipe into water plug until it reaches the white tape.
T
ighten the clip until head of the screw is less than 4mm from hose. Wind the drainage hose to the clip using seal pad for heat insulation. Insulate drainage hose in the room.
(accessory)
Cautions for the water drainage lifting pipe
Installation height of water drainage lifting pipe shall be less than 280mm There should be a right angle with unit ,300mm from unit.
< Note >
The slope of water drainage hose shall be within 75mm , make the drainage plug not to bear excessive force.
If several water hoses join together, of as per following procedures.
Specifications of the selected drainage hoses shall meet the requirements for the unit running
1-1.5m
Slope over 1/100
Tape(white)
Draingage hose
Clip
Clip
Water drainage lifting pipe
Suspending bracket
Drainage hose
280mm unter
500mm below
Drainage hose
75mm below
500mm below
220mm
Slope below 1/100
Connection drainage hose with a T-joint
100mm üover
Installation Procedures
28
4. Installation of Ornament Panel
Install ornament panel on indoor unit
(1) Check whether indoor unit is horizontal with leveler or polythene pipe filled with water , and check that the dimension of the ceiling opening is correct. Take off the lever gauge before install the ornament panel. (2)Fasten the screws to make the height difference between the two sides of indoor unit less than
5mm. (3) First fix it with screws temporally. (4) Fasten the two temporally fixing screws and other two, and tighten the four screws. (5) Connect the wires of synchro-motor. (6) Connect the wire of signal. (7) If no response of remote controller,check whether the wiring is correct,restart remote controller
10 seconds after shut off power supply.
Limits of panel board installation
(1)Install the panel board in the direction shown in the figure. (2)The incorrect direction will result in water leakage, meanwhile swing and signal receiving are displayed that cannot be connected.
Display window
Drain hose
Pipe
Pipe
Louver motor
Liquid inlet pipe
Gas outlet pipe
Drain hose
Installation Procedure
29
Piping Connection
(1) Dimension of connecting pipe
Fit the nut on and fasten
(2) The maximum length and drop height of connecting pipe
The maximum length is 10m The maximum drop height is 5m.
T o ensure the ef ficiency ,Pipes shall be as short as possible.
Cautions for piping connection
Do not twist or deform the connecting pipe. Do not mix dusts.
The bending radius shall be as large as possible. Both gas pipe and liquid pipe shall be heat insulation.
No leakage in the flare.
Spanner
Spanner
Joint
Nut
(3) Piping connection
Connecting method
Smear refrigerant oil on the joints of piping and flare. The bending radius shall be as large as possible. Align the pipe center when fastening, and tighten the nut, as shown in the figure. Pay attention to not mix foreign matters such as sands in.
Diameter of Pipe
Liquid Pipe 6.35mm Gas Pipe 12.7mm
Tighten Torque
18 N. m
50N. m
If not aligned ,tighten the nut by force will damage the nut that result in gas leakage
Flare connection
Gas pipe
3-way valve
Indoor Unit
Outdoor unit
Liquid pipe
2-way valve
Flare connection
90 + 0.5
12.7mm
6.35mm
Gas pipe
Liquid pipe
Installation Procedures
Air Discharge Method
Discharge the air in the unit and piping as shown in the figure. (1) Remove bonnet of 2-way valve of outdoor unit. (2) Loosen the flare nut connected to the thick pipe of 3-way valve 1-2 turns with spanner. (3) Loosen valve core of 2-way valve 90 degree with inner hexagon spanner,and fasten up the 2-way valve appro­ ximate 10 seconds later Gas is discharged through flare, tighten flare nut on the 3-way valve according to the spec­ ified torque when no gas is discharged any more. (4) Open 2-way valve and 3-way valve. (5) Tighten bonnets of the two valves according to the specified torque. (6) Check for gas leakage with leakage indicator or soapy water. If any leakage exists,fasten the 2-way valve and 3-way valve, then discharge air again using Feron(R22) outside of the system.
Table 2
Specification
Torque
Valve core Valve bonnet
Tighten Torque N.m
7-9
20-25
The refrigerant shall be injected according to the table below if the connecting pipe is more than 5m long
Length of pipe
Quantity of refrigerant added(g)
5m 7m 10m 15m
N.A 32g 90g 180g
Note:When piping is extended,first discharge airs in the connecting pipe with outside freon R22, and then discharges the excessive refrigerant using bbove method.
As for newly manufactured air conditioner,additional 60g R22 has already been added based on the specified refrigerant quantity.This method is only applied to the first installation to blow off air inside the connection pipe and indoor unit.
30
2-way valve
3-way valve
Open
90
Liquid pipe
6.35mm(1/4”)
Flare nut
12.70mm(1/2”)
Installation Procedures
1234
1(L)
1234
34NL
1234
24NL
1234
32
Correct
Incorrect
A
Pipe expander
Other Instructions
1.Configuration of power supply
Air conditioner must use special power supply system (above 20A), and qualified electrician makes wiring and fixing according to wiring regulations specified in national standard.
In socket, exactly distinguish earth wire with neutral wire and it is wrong to connect them together. A leakage breaker must be installed.
Parameters of power supply: H07RN-F 3G 2.0mm
2
Connection method is Y-connection .If the power cord is damaged, it must be replaced by professional people of manufacturer or its maintenance department or similar to avoid dangers.
2.Pipe cutting and expanding
Must remove burrs if cut pipes with pipe cutter. Expand flare after insert the pipe expander.
Liquid pipe
Gas pipe
Diameter of pipe
Dimension A (mm)
0.8~1.5
1.2~2.0
6.35mm (1/4”)
12.7mm (1/2”)
Deflection
Crack occurs
Broken
Incomplete
Over outward
Installation check and test run
Require customers to use air conditioner according to the operation manual. The items checked during test run,please mark in
No gas leakage on the pipe joint ? How about the thermal insulation of the pipe joint:
Is the electrical wiring between indoor and outdoor unit connected to the terminal block firmly? Is the wiring of indoor and outdoor unit secured firmly?
Is the drainage hose arranged correct? Is the earthing wire connected firmly? Is the power supply voltage conformed to the electrical regulation?
Any noise? Is the display on the control board (LCD) correct? Cooling normal? Does the indoor temperature regulator work normally? For the power supply L shall be connected to the live wire.
N shall be connected to the neutral wire.
Shall be connected to the earth wire.
Installation Procedures,Check and Test Run
33
Detach the charge hose from the service port, open 2-way valve and 3-way
. Turn the valve rod
anticlockwise until hitting lightly.
6
No gas leakage?
5
4
Open the valve rod for the 2-way valve to and angle of anticlockwise 90 degree. After 6 seconds later
, close the 2-way valve and male
the inspection of gas leakage.
3
Vacuumize for over 15min. And check the level gauge which should read -0.1 MPa (-76 cm Hg) at low pressure side.
After the completion of vacuumizing, close the handle 'Lo' in gaugemanifold and stop the operation of the vacuum pump. Check the condition of the scale and hold it for 1-2min. If the scale-moves back in spite of tightening, make flaring work again, the return to the beginning of 3 .
2
Open the handle at low in gaugemanifold, operate vacuum pump. If the scale-moves of gause (low) reach vacuum condition in a moment, check 1 again.
1
Detach the service port's cap of 3-way valve, the valve rod's cap for 2-way valve and 3-way's, connect the service port into the projection of charge hose (low) for gaugemanifold.
Then connect the projection of charge hose (center) for gaugemanifold into vacuum pump.
To use vacuum pump
CAUTION:
If the refrigerant of the air conditioner leaks, it is necessary to make all the refrigerant out, then charge the liquid refrigerant into air conditioner according to the amount marked on the name plate.
7
8
After attaching the each caps, check the gas leakage around the caps.
To prevent the gas leakage, turn the service port's cap, the valve rod'd cap for 2-way valve and 3-way's a lottle more than the point where the torque increases suddenly
.
For AB142ACBAA AU142AFBBA (HBU-14HA03/R1) , AB142ACNAA AU142AFNBA(HBU-14CA03/R1) the refrigerant is R407C
If needing to recycle the refrigerant gas when installation or repair , please refer to the following procedures:
1. Cut off the power
2. (After confirming the power is cut off) pull the power cable plug terminals of the low-pressure pressure-switch out.
3. (After confirming the power cable terminals of the low-pressure pressure-switch is cut off) After powering on the unit again and switch to COOLING mode,perform refrigerant gas recycling according to the normal refrigerant gas recycling procedure.
4. After finishing refrigerant gas recycling , cut off the power , then insert the power cable terminals of the low-pressure pressure-switch properly
.
In case of gas leakage, tighten parts of pipe connection. If leakage stops, then proceed steps.
6
Liquid pipe
Gas pipe
Gaugemanifold
Vacuum pump
3-way valve
2-way valve
6.35mm(1/4'')
15 88mm(5/8'')
Service port cap
7
2-way valve
3-way valve
Valve rod cap
Valve rod cap
6
6
2-way valve
3-way valve
2
Open
3
Close
If it does not stop gas leakage, discharge whole refrigerants from the serice port. After flaring work again and vacuumize, fill up prescribed refrigerant from the gas cylinder
.
Air purging Method ( to use vacuum pump )
90
for 6 sec.
4
Service port
90
90
3-way valve
2-way valve
7
7