Haier AS07QS1ERA, AS09QS1ERA, AS12QS1ERA Operation Manual

Please read this operation manual before using the air conditioner.
Keep this operation manual for future reference.
SPLITTYPEROOMAIRCONDITIONER OPERATION MANUAL
0010539319
AS09QS1ERA AS12QS1ERA
PARTS AND FUNCTIONS OPERATION MAINTENANCE
TROUBLE SHOOTING
CAUTIONS
Contents
13
12
14
Índice
PRECAUCIONES
PIEZAS Y FUNCIONES
FUNCIONAMIENTO MANTENIMIENTO
RESOLUCIÓN DE PROBLEMAS
20
15 16 19
21
Contenuti
ATTENZIONE
PARTI E FUNZIONI FUNZIONAMENTO
MANUTENZIONE
RISOLUZIONE DEI PROBLEMI
27
22 23 26
28
Table des matières
MISES EN GARDE
PIÈCES ET FONCTIONS UTILISATION MAINTENANCE
DÉPANNAGE
AS07QS1ERA
Outdoor Unit
Loading of the battery
1 2
3
4
Parts and Functions
Indoor Unit
OUTLET
INLET
CONNECTING PIPING AND ELECTRICAL WIRING
DRAIN HOSE
Remote controller
Remove the battery cover;
Load the batteries as illustrated.
2 R-03 batteries, resetting key
(cylinder);
Be sure that the loading
is in line with th
e" + "/"-";
Load the battery,then put on the cover again.
The distance between the signal transmission head and the rece­iver hole should be within 7m without any obstacle as well.
When electronic-started type fluorescent lamp or change- over
wireless telephone is installed in the
ver is apt to be disturbed in receiving
the signals,
so the distance to the indoor unit should be shorter.
type fluorescent lamp or room, the recei
Note:
Full display or unclear display during operation indicates the
ries have been used up.
Please change batteries.
If the remote controller can't run normally during operation, please
reload several minutes later.
batte
remove the batteries and
Please be subject to the actual produce purchased the above picture is just from your reference
4
Hint: Remove the batteries in case won't be in use for a long period. If there is any display after taking-out, just press reset key.
1. Mode display
2. Signal sending display
4. FAN SPEED display
5. LOCK display
6. TIMER OFF display TIMER ON display
LO MED HI
7.TEMP display
16. LOCK button
Used to lock buttons and LCD display.
25. RESET button When the remote controller appears abnormal, use a sharp pointed article to press this button to reset the remote
22. HOUR button
Operation mode
AUTO FANCOOL DRY
Remote controller
HEAT
1
2
3
4
5
9
10
11
12
13
14
15
16 17
22
23
24
25
19
20
21
8
18
7
6
Control the lightening and extinguishing of the indoor LED display board.
3. SWING display
8
.
9. QUIET button
10. HEAT button
11. COOL button
12. AUTO button
13. FAN SPEED button
14. TIMER button
15. HEALTH button
17. LIGHT button
18. POWER ON/OFF button
19. DRY button
20. TEMP button
21. SWING button
23. EXTRA FUNCTION button
24.CANCEL/CONFIRM button
AUTO
Function: Setting and cancel to the timer and other additional functions.
Display circulated
Operation mode
Remote controller
QUITE
POWER
SLEEP
HEALTH
Additional functions display
Healthy function is not available for some units.
Function: FAN mode --- Healthy airflow position1--- Healthy airflow position 2 --- Restore the original flap position --- Right & left air airflow
--- A-B yard---10 and heating symbol displayed simultaneously--- Sleeping
--- Electrical heating--- Refresh air (
reserved function) --- Power ---
Fahrenheit/Celsius mode conversion
Actual indoop unit may vary from the one shown
in the manual, according to the product purchased.
TEMP display
Display board
COOL: blue
AUTO: white
HEAT: red
DRY: cyan
FAN: yellow
: green
HEALTH
Aureol
Display modethe aureole display different colour when setting different function
Inlet grille
Inlet
Air Purifying Filter
(inside)
Emergency
Switch
Display board
(Adjust left and right air flow)
Vertical blade
Horizontal flap
(Adjust up and
down air flow, Don't adjust it manually)
Outlet
Nano-aqua generator
(inside)
Operation
Air Flow Direction Adjustment
Press FAN button. For each press, fan speed
follows:
Remote controller:
Press
button
Every time the button is pressed, temp.setting increase 1
o
C,if kept depressed, it will increase
rapidly
Every time the button is pressed, temp.setting
decrease 1
o
C,if kept depressed, it will
decrease rapidly
Select a desired temperature.
4.Fan speed selection
3.Select temp.setting
Air conditioner is running under displayed fan speed. When FAN is set to AUTO, the air conditioner automatically adjusts the fan speed according to room temperature.
1. Unit start
Press ON/OFF on the remote controller, unit starts.
Base Operation
Remote controller
1.Status display of air flow
When restart after remote turning off, the remote
memorize the previous
2.Left and right air flow adjustment
Cautions:
When adjusting the flap by hand,turn off the unit.
When humidity is high,condensate water might occur
adjusted to left or
It is advisable not to keep horizontal flap at downward position for a long time in COOLor DRY
otherwise, condensate water might occur.
Emergency operation and test operation
at air outlet if all vertical louvers are
right.
mode ,
controller will automatically
Note:
set swing position.
changes as
Operation
Mode
Remote
Controller
Note
In DRY mode , when room temperature becomes lower than temp.setting+2
o
C, unit will run intermittently at LOW
speed regardless of FAN setting.
Under the mode of auto operation, air conditioner will automatically select Cool or Heat operation according to
room temperature. When FAN is set to AUTO the air conditioner automatically adjusts the fan speed according to room temperature.
In FAN operation mode , the unit will not operate in COOL or HEAT mode but only in
FAN mode, AUTO is not available in FAN mode. And temp. setting is disabled. In FAN mode, sleep operation is not available.
Emergency Operation:
Use this operation only when the remote controller is defective or lost, and with function of emergency running, air conditoner can run automatically for a while. When the emergency operation switch is pressed, the " Pi " sound is heard once, which means the start of this operation. When power switch is turning on for the first time and emergency operation starts, the unit will run automatically in the following modes:
Room temperature
Designated temperature
Timer mode
Fan
speed
Operation
mode
Above 2oC
Below 2
o
C 2oC
2
o
C
No
AUTO
AUTO
COOL
HEAT
No
It is impossible to change the settings of temp. and fan speed,It is also not possible to operate in timer or dry mode.
temperature is below 16
o
C, do not use it in the
Test operation:
Use this switch in the test operation when the room
normal operation.
your finger from the switch: the cooling
Continue to press the test operation
switch for more than 5 seconds . After
you hear the "Pi" sound twice,
release
Test ope ration switch is the same as emergency switch.
operation starts with the air flow speed "Hi".
LOW
MED HI
COOL/DRY:
HEAT:
Initial state
AUTO
2. Select operation mode
COOL button:Cooling mode HEAT button: Heating mode DRY button: Dehumidify mode
Display
circulated
Pi
Pi Pi
DRY
COOL
AUTO
HEAT
FAN
In HEAT mode, warm air will blow out after a short period of the time due to cold-draft prevention function. When FAN is set to AUTO, the air conditioner automatically adjusts the fan speed according to room temperature.
remote controller:
Initial state
For each press of “ ” buttor,remote controller displays as follows:
Operation
Sleep Operation
If the wind speed is high or middle before setting for the sleep, set for lowing the wind speed after sleeping. If it is low wind, no change.
5.Set the wind speed change when sleeping
Operation Mode
1. In COOL,DRY mode
SLEEP operation starts SLEEP operation stops
SLEEP operation starts
SLEEP operation stops
Approx.6hrs
1 hr
1 hr
1 hr
3 hrs
3 hrs
Rises 1OC
Rises 1
O
C
Rises 1OC
Temp.setting
Temp.setting
Unit stop
Unit stop
In COOL, DRY mode
In HEAT mode
Decreases 2OC
Decreases 2
O
C
1 hr
2.
3.
In HEAT mode
In AUTO mode
4. In FAN mode
It has no SLEEP function.
Note
POWER/QUIET Operation
1 hours after SLEEP mode starts,temp.will become higher than temp.setting.After another 1 hours,temp.rises by 1 futher.The unit will run for further
6 hours then stops Temp. is higher than temp.setting so that room temperature won’t be too low for your sleep.
1 hours after SLEEP mode starts,temp will become 2 lower than temp.setting.After another 1 hours,temp decrease by 2 rises
by 1 futher.The unit will run for further 3 hours
then stops.Temp.is lower than temp. setting so that room
temperature won’t be
too high for your sleep.
The unit operaters in corresponding sleep mode adapted to the automatically selected operation
mode.
O
C
O
C futher.After more another 3 hours,temp.
O
C
1
O
C
O
C
Press button to enter additional options, when cycle display to , will flash. And then press enter to sleep function.
(1)
POWER Operation
(2)
QUIET Operation
Note ˖
When you need rapid heating or cooling, you can use this function.
You can use this function when silence is needed for rest or reading.
During POWER operation, in rapid HEAT or COOL mode , the room will show inhomogeneous temperature distribution. Long period QUIET operation will cause effect of not too cool or not too warm.
Press QUIET button, the remote controller will show , and then achieve to the quiet function. Press again this QUIET button , the quiet function will be cancelled.
Press button to enter additional options, when cycle display to , will flashand then press ,enter to power function. When cancel the function, please enter
additional options again and to cancel power function.
HEALTH Operation
After TIMER ON setting,SLEEP is unavailable; After SLEEP setting,then TIMER ON setting,SLEEP is cancelled automatically. After TIMER OFF setting,then SLEEP setting,it's available and running as sequencing; After SLEEP setting,then TIMER OFF setting,it's available and running as sequencing.
Nano-Aqua generator adopt two high voltage poles to
ionize the water molecule, produces plenty of positive and
negative ions, and release these ions to the air to kill the
bacterium, as well as to refresh the air.
Operation
1.After unit starts, select your desired operation mode.
2.Press TIMER button to change TIMER mode. Every time the button is pressed, display changes as follows: Remote controller:
BLANK
TIMER ON TIMER OFF TIMER ON-OFF
Then select your desired TIMER mode (TIMER ON or TIMER OFF or TIMER ON-OFF). " "or " "will flash.
3.Press / button to set time.
It can be adjusted within 24 hours.
Hints: After replacing batteries or a power failure happens, time setting should be reset.
According to the Time setting sequence of TIMER ON or
TIMER OFF, either Start-Stop or Stop-Start can be achieved.
Timer On/Off On-Off Operation
CE
All the products are in conformity with the following European provision:
- Low Voltage Directive 73/23/EEC
- Low Voltage Directive 2006/95/EC
-Electomagnetic CompatibilitY 89/336/EEC
-Electomagnetic CompatibilitY 2004/108/EC
ROHS
The products are fulfilled with the requirements in the directive 2002/95/EEC of the European parliament and of
council on the Restriction of the use of Certain Hazardous Substances in Electrical and Electronic Equipment (EU RoHS Directive)
WEEE
DISPOSAL REQUIREMENTS:
Your air conditioning product is marked with this symbol.This means that electrical and electronic
products shall not be mixed with unsorted household waste. Do not try to dismantle the system yourself : the dismantling of the air
EUROPEAN REGULATIONS CONFORMITY FOR THE MODELS
1
1+2=
kg
R410A
2
kg
2=
1=
B
C
D
FE
kg
A
This product contains fluorinated greenhouse gases covered by the Kyoto Protocol. Do not vent into the atmosphere.
Refrigerant type:R410A GWP* value:1975 GWP=global warming potential Please fill in with indelible ink,
• 1 the factory refrigerant charge of the product
• 2 the additional refrigerant amount charged in the field and
• 1+2 the total refrigerant charge on the refrigerant charge label supplied with the product. The filled out label must be adhered in the proximity of the product charging port (e.g. onto the inside of the stop value cover). A contains fluorinated greenhouse gases covered by the Kyoto Protocol B factory refrigerant charge of the product: see unit name plate C additional refrigerant amount charged in the field D total refrigerant charge E outdoor unit F refrigerant cylinder and manifold for charging
IMPORTANT INFORMATION REGA­RDING THE REFRIGERANT USED
In accordance with the directive 2002/96/CE of the European parliament, herewith we inform the consumer about the dis-
posal requirements of the electrical and electronic products.
conditioning system,treatment of the refrigerant, of oil and of other part must be done by a qualified installer in
accordance
with relevant local and national legislation. Air conditioners must be treated at a specialized treatment facility for reuse, recycling and recovery. By ensuring this product is disposed of correctly, you will help to prevent potential negative cons­equences for the environment and humen health. Please contact the installer or local authority for more information. Battery must be removed from the remote controller and dis­posed of separately in accordance with relevant local and nationl legislation.
Contains fluorinated greenhouse gases covered by the Kyoto Protocol
Healthy airflow Operation
1.Press to starting
Setting the comfort work conditions.
2.The setting of healthy airflow function
Note:
1.After setting the healthy airflow function, the position
grill is fixed.
4.In cooling and dry, using the air conditioner for a long time under the high air humidity, condensate water may occur at the grille .
3.The cancel of the healthy airflow function
Notice: Do not direct the flap by hand. Otherwise, the grille will run incorrectly. If the grille is not run correctly, stop
for a minute and then start, adjusting by remote controller.
2.In heating, it is better to select the
3.In cooling, it is better to select the
mode. mode.
TIMER OFF-ON
0.5h
0.5h 0.5h
0.5h
Press the button for each time, setting time in the first 12 hours increased by 0.5 hour every time, after 12 hours,increased by 1 hour every time.
Press the button for each time, settiing time in the first 12 hours decreased by 0.5 hour every time, after 12 hours,decreased by 1 hour every time.
After adjust the time,press button and confirm the time ON or OFF button will not flash any more.
4.Confirm timer setting
5.Cancel timer setting Press the timer button by times until the time display eliminated.
Press button to enter additional options,Press this button continuously, the louvers location will cycle between in the following three locations, to choose the swing location what you needed,and then press button to confirm.
Press button to enter additional options,Press this button continuously, the louvers location will cycle between in the following three locations again,and then press button to cancel.
Healthy airflow upwarder
Healthy airflow downwarder
Present position
Maintenance
Setting of proper room temperature
Close doors and windows during operation
If the unit is not to be used for a long time, turn off the power supply main switch.
Use the timer effectively
Use the louvers effectively
Do not block the air inlet or outlet
Proper
temperature
During cooling operation
prevent the penetration of
direct sunlight with
curtain or blind
OFF
Remote Controller Indoor Body
1.Open the lnlet Grille
2.Detach the standard air filter
3.Attach Air Purifying Filter
4.Attach the standard air filter
(Necessar
y installation)
5.Close the Inlet Grille
Close the Grille surely
Slide the knob slightly up
ward to
release the filter, then withdraw it.
Put air purifying filter appliances into the
right and left filter frames.
NOTE:
The photocatalyst air purifying filter will be solarized in fixed time. In normal family,
it will be solarized every 6 months.
Prop up the inlet grille by using a
small device named grille-support
ATTENTION:
Please keep the bacteria-killing medium air purifying filter in
avoid long time directly sunshine
when you stop using it,or its ability of sterilization will
be
reduced.
The bacteria-killing medium air purifying filter will be used for a long time,no need for replacement. But in the period of using them ,you should remove the dust frequently by
which located in the right side of
the indoor unit.
using vacuum cleaner or flaping them lightly,otherwise ,
its performance will be affected.
the cool and dry conditions
For Smart Use of The Air Conditioner
Replacement of Air Purifying Filter
The white side of the photocatalyst air purifying filter face outside,and the black side face the unit The green
side of the bacteria-killing medium air purifying filter face outside,and the white side face the unit.
Do not usewater,wipe the controller with a dry cloth.Do not use glass
cleaner or chemical cloth.
wipe the air conditioner by using a soft and dry cloth.For serious stains,
use a neutral detergent diluted with water.Wring the water out of the cloth before wiping,then wipe off the detergent completely.
Air Filter cleaning
Open the inlet grille by pulling it upward.
Remove the filter.
Clean the filter.
Attach the filter.
Close the inlet grille.
Push up the filter's center tab slightly until it is
from the stopper, and remove the filter do
wnw
ard.
Use a vacuum cleaner to remove dust, or wash the filter with water.After washing, dry the filter completely in the shade.
Attach the filter correctly so that the "FRONT" indication
facing to the front.Make sure that the filter is
fixed behind the stopper.If the right
attached correctly, that
Do not use the following for cleaning
Gasoline,benzine, thinner or cleanser
ay
damage the coating of the unit.
Hot water over 40
O
C(104OF) may
discoloring or deformation.
Once every two weeks
m
cause
released
is
completely
and left filters are not
may cause defects.
Detach old Air Purifying Filter
the power supply cord and so on.
2.
Do not install in the place where there is any
possibility of inflammable gas leakage around the unit.
3.Do not get the unit exposed
to vapor or oil steam.
Cautions
Please call Sales/Service Shop for the Installation.
Do not attempt to install the air conditioner by yourself because improper works may cause electric shock, fire, water leakage.
Connect the earth cable.
earthing
WARNING
When abnormality such as burnt-small found, immediately stop the operation button and contact sales shop.
OFF
Use an exclusive power source with a circuit breaker
ENFORCEMENT
Connect power supply cord to the outlet completely
Use the proper voltage
Do not use power supply cord in a bundle.
Take care not to damage
the power supply cord.
1.Do not use power supply cord extended or connected in halfway
STRICT
ENFORCEMENT
STRICT
STRICT
ENFORCEMENT
PROHIBITION
PROHIBITION
PROHIBITION
PROHIBITION
Do not start or stop the
operation by disconnecting
Do not channel the air flow directly at people, especially at infants or the aged.
Do not try to repair or reconstruct by yourself.
Do not use for the purpose of storage of food, art work, precise equipment, breeding, or cultivation.
CAUTION
Take fresh air occasionally especially when gas appliance is running at the same time.
PROHIBITION
STRICT
ENFORCEMENT
Do not operate the switch with wet hand.
PROHIBITION
PROHIBITION
PROHIBITION
PROHIBITION
PROHIBITION
Do not install the unit near a fireplace or other heating apparatus.
Check good condition of the installation stand
Do not pour water onto the unit for cleaning
PROHIBITION
Do not place animals or plants in the direct path of the air flow
Do not place any objects on or climb on the unit.
Do not place flower vase or water containers on the top of the unit.
Do not insert objects into the air inlet or outlet.
PROHIBITION
PROHIBITION
PROHIBITION
STRICT ENFORCEMENT
Check proper installation of the drainage securely
WARNING
Trouble shooting
Normal Performance inspection
Noise is heard
Phenomenon
Cause or check points
The system
immediately.
Smells are
generated.
Mist or steam are
Multiple
check
Poor cooling
When unit is stopped, it won't restart
elapsed to protect the system. When the electric plug is pulled out
and reinserted, the protection circuit
During unit operation or at stop, a swishing or gurgling noise may
(This noise is generated by refrigerant flowing in the system.)
During unit operation, a cracking
noise may be heard.This noise is
temperature changes. Should there be a big noise from
filter may be too dirty.
This is because the system circulates smells from the interior
During COOL or DRY operation,
This is due to the sudden cooling
Is power plug inserted? Is there a power failure? Is fuse blownout?
Is the air filter dirty?
Are there any obstacles before
Is temperature set correctly?
Are there some doors or
Is there any direct sunlight through the window during the
Are there too much heat sources or too many people in the room
In dry mode,
fan speed can’t be changed.
In DRY mode, when room temperature
setting+2
o
C,unit will run
regardless of FAN setting.
during cooling operation?
cooling operation?(Use curtain)
windows left open?
inlet and outlet?
Normally it should be cleaned every 15 days.
intermittently at LOW speed
becomes lower than temp.
indoor unit may blow out mist.
of indoor air.
air such as the smell of furniture, paint, cigarettes.
air flow in unit operation, air
generated by the casing expanding or shrinking because of
be heard.At first 2-3 minutes after unit start, this noise is more noticeable.
will work for 3 minutes to protect the air conditioner.
immediately until 3 minutes have
Cautions
3. If the fuse of indoor unit on PC board is it with the type of
T. 3.15A/ 250V
outdoor
broken,change it with the type of
T.25A/250V
Do not obstruct or cover the ventilation
conditoner.Do not put fingers
inlet/outlet and
swing louver.
Do not allow children to play with the air
conditioner
case should children be
allowed to sit on the outdoor unit.
The refrigerating circuit is leak-proo f.
1.Applicable ambient temperature range:
Specifications
The machine is adaptive in following
situation
The power plug and connecting cable
acquired the local
2. If the power supply cord is damaged, it
must be replaced
manufacturer
qualified
person.
4. The wiring method should be in line with
the local wiring
5. After installation, the power plug should
be easily reached.
6. The waste battery should be disposed
properly.
7. The appliance is not intended for use persons
without supervision.
8.Young children should be supervised
with
the appliance.
9. Please employ the proper power plug,
cord.
11.In order to protect the units,please turn 30 seconds
later, cutting off the power.
10.
Cooling
Indoor
Maximum:D.B/W.B
Maximum:D.B/W.B
D.B
Maximum:D.B
D.B
Minimum:D.B/W.B
Maximum:D.B/W.B Minimum:D.B/W.B
Outdoor
Indoor
Outdoor
Heating
32oC/23oC
24
o
C/18oC
o
C/-8oC
46
o
C/26oC
18
o
C
27
o
C
21
o
C/15oC
Outdoor
Maximum:D.B/W.B Minimum:D.B
24
o
C/18oC
-15
o
C
(INVERTER)
o
C
7
-
Minimum:
Minimum:
grille of the air
or any other things into the
.In no
or its service agent or a similar
broken,please
. If the fuse of
standard.
by young children or
to ensure that th
ey
which fit into the
must have
off the A/C first,
Before asking for service, check the following first.
blown out.
does not restart
by the
change
unit is
infirm
do not play
p
ower supply
attestation.
and at least
15
Loading...
+ 22 hidden pages