Haier AP88NACBEA user guide manual

Cabinet unit
Operation Manual
AP88NACBEA AU88NATBEA
No.0010573003
Operation points Name of Parts Safety Precautions Operation instruction Users' Attention Maintenance Trouble shooting When problems occur When troubles occur Installation instruction Installation procedure Others
1 2-3 4-5 6-10 11 12-13 14 15 16 17 18-30 31-32
CONTENTS
Change of fan speed
In COOLING mode, the air sending is set at AUTO, when the indoor temperature is near the set temperature, the fan speed will lower automatically.In HEATING mode, when room temperature reaches the set temperature, the compressor will stop running, and the fan will change to LOW FAN or stop.
In DEHUMIDIFYING mode,
the fan speed will change automatically.
3-minute protection function
If start the unit immediately only after it is turned off, the compressor will start after 3 minutes have elapsed to protect the compressor.
Operation of air conditioner
When the ambient humidity is too high, in COOLING or DEHUMIDIFYING mode, there may be water dropped in the air outlet.
Anti-cold air blowing out
During Heating operation, after starting the unit, the indoor fan motor will not rotate immediately to prevent cold air from blowing out.
Defrosting function
During Heating operation, when frost formed on the heat exchanger of outdoor unit, the air conditioner will defrost automatically for several minutes. During defrosting, both the fan of indoor and outdoor unit do not run. After finishing defrosting, the air conditioner will automatically resume operation.
Hint
When the air conditioner is in Heating mode, it absorbs heat from outside and release to indoors. So the outdoor temperature may affect the Heating effect.
Power failure resume function (please set and use this function according to actual
condition)
After setting power failure resume function, if there is a sudden power failure during unit operation, when power on for again, the unit will resume the previous state.
Setting method: when the wire controller is in ON state (except for TIMER and FAN
mode), press the SLEEP button for 10 times in 5 seconds, after the buzzer sounds 4 times, the unit will change to POWER FAILURE RESUME function. Cancellation method: press the SLEEP button 10 times in 5 seconds, after the buzzer 2 times, the POWER FAILURE RESUME function is cancelled.
Note: After the unit is set POWER FAILURE RESUME function, if there is a sudden power failure
in using, during this period of time if there is no need to use the unit for a long time, please cut off power to prevent the air conditioner from automatically resuming to the previous setting if powerfailure resumes, or press the ON/OFF button to turn off the unit after power failure resumes.
Operation points
1
?
Outlet grill
Operation panel
Inlet grill
Indoor unit
Outdoor unit
Air inlet
Air inlet
Air inlet
Air outlet
Name of Parts
The interface of the refrigerant pipe
2
Note:
Open the power switch 12 hours before the unit running.Do not cut off the power when short time stop the unit (like one day and one night ),this is to protect the compressor. Do not block the air inlet and air outlet, otherwise the performance of the air conditioner may be lowered and it will make the protection device act.
Name of Parts
Wire Controller
14.Network control display
Used to adjust the time of timer and clock
When the wire controller appears abnormal condition, use a sharp-pointed article to press this button to make the wire controller resume normal
After cleaning the air inlet, press this button, the unit can start to operate
12.Humidifying state display
Used to turn on/off unit
1.ON/OFF button
6.Air filter cleaning display
7.Super/Soft operation display
13.Sleep state display
2.T
emperature display
24.Time Adjusting button
23.Sleep button Used to set Sleep
state or Power Failure Resume Function
When there is too much dust collected on the air inlet, the wire controller will show this display to remind the user to clean the air inlet. After cleaning and installation, just press the air filter reset button.
8.Fan speed display
9.Auto Swing display
11.Fresh air state display
25.Reset button
26.Air Filter Reset button
27.Timer button
Used to set the mode of timer
29.Lock state display
28.Electric heating button
4.Timer ON/OFF display
3.Clock display
17.Operation mode button
5.Humidity display
22.Setting button Used to confirm
the time of timer and clock
15.Working mode display
21.Clock button Used to calibrate the time of timer and clock
16.Electric heating display
Used to set working mode: Auto, Cooling, Dehumidifying, Heating, Fan
18.Fan speed button Used to set fan speed: Low Fan, Med Fan, High Fan, Auto
20.Temperature Setting button
10.Health state display
Used to set temperature, temperature range: 16*~30*
19.Swing button
Used to set Auto Swing or Fixed air sending direction
Note:
1.This model does not have the following related display and function
2.Non-electric heating type, there is no electric heating button and electric heating
display
* * 10 11 12
28
16
6
Auto
Low Fan Med Fan High Fan Auto
Working mode
Auto operation
Cooling operation
Dehumidifying operation
Heating operation
Fan operation
Wire controller
Calibration of clock
When turning on the unit for the first time, the clock should be calibrated. The method of calibration is:
1.Press ì Clockî button, the Clock display ì AMî ìPMî will flash.
2.Press * or to adjust time. For each press, the time will increase or decrease 1
*minute. If depressing the button, the time will increase or decrease rapidly.
3.After confirming the time, press ì Setî button, ìAMî or ì PMî will stop flashing,
*the clock will begin to work.
*
SET
ROOM
AUTO
29
3
MODE FAN SW NG
TEMP
C OCK
TIMER
SET
SLEEP
FILTER R T
RESET
ON/OFF
HEAT
Safety Precautions
Before starting the unit, please read the following ì Safety Precautionsî carefully to guarantee the normal operation of the system. The following lists two kinds of safety precautions ì Warningî and ì Noticeî. For the items that the improper use may cause death or serious injury are listed in ì Warningî volume. However, sometimes the items listed in ì Noticeî volume may also cause serious accidents.
So, these two volumes are the important contents related
to safety, they
must be observed.
Installation Safety Precautions
Warning
The system should be applied to places as office, restaurant, residence and the like.
The system should be installed by your dealer or a professional installer.
Application to inferior environment such as workshop, it may cause equipment malfunction and serious injury or death.
Installation by yourself is not encouraged. Because improper installation could cause water leakage, electric shock and fire accident.
Notice
Operation safety precautions
Do not let the cold wind blow to human body for a long time.
When any abnormal condition (scorching smell or others) is found, stop operation immediately and turn off the power switch. Then consult your dealer.
Warning
It may affect the physical condition or cause some health problems.
If continuing the operation without removing the cause, it may cause trouble, electric shock or fire.
After carefully reading this manual, please keep in hand for reference. If the air conditioner is given to a new user, this manual should be attached with unit to the new user.
Grounding wire should never be connected to gas pipe, city water pipe, lightning conductor rod or the telephone line. If the grounding wire is not set properly, it may cause electric shock.
N
OFF
A creepage breaker must be installed at the installation place
Drain pipe should be arranged properly to provide a smooth drainage.
Unless the circuit breaker is installed, it may cause electric shock.
If the pipe is arranged improperly, furniture or the like may be damaged by the leaked water.
Make sure the system is grounded.
Notice
Do not handle switches with a wet hand.
It may cause electric shock.
Do not use water to clean the air conditioner.
It may cause electric shock.
Do not do like this Do follow the instruction Do equip with grounding wire
4
Safety Precautions
Notice
The system should never be used for any other purposes than intended such as for preservation of food, flora and fauna, precision devices or work of art.
Do not put the fire devices in the places, which the air from the air conditioner can directly blow.
It may cause deterioration of the articles.
It may cause the fire devices cannot burn completely.
Do not install the system where the air outlet may directly reach the flora and fauna.
Only use the proper specified fuse.
It will not be good for their health.
If use metal wire or copper wire to replace the fuse, it may cause trouble and fire accident.
Do not put or use any spray near the air conditioner, and do not directly spray to the air conditioner.
Otherwise it may cause fire.
Safety precautions when moving, reinstalling and repairing the air conditioner
Warning
ON
OFF
Do not use the pow­er switch to turn of or off the air condit­ioner.
Do not use such equipment as a water heater, etc., around the indoor unit or the wire controller.
It may cause fire or Creepage.
If the system is operated at the vicinity of such equipment that generates steam, condensed water may drip during cooling operation or it may cause Creepage or short-circuit.
When operating the system sim­ultaneously with a combustion apparatus, indoor air must be v­entilated frequently.
*
Insufficient ventilation may ca­use the danger of lack of oxygen.
When cleaning, please stop the unit and cut o­ff the power first.
Do not put the water containers, such as vase, on the unit.
Do not perform cleaning, when the indoor fan motor is rotating in high speed.
If the water enters into the unit and damages the electric insulation material, it may cause electric shock.
Do not refit the air conditioner. When repair is needed, please contact your dealer.
When moving the air conditioner to another installation place, please contact the dealer or the professional installer.
Improper repair may cause water leakage, electric shock and fire accident.
Improper moving and reinstallation may cause water leakage, electric shock and fire accident.
5
LOW FAN MED FAN HIGH FAN
Operation instruction
MODE FAN SWING
TEMP
CLOCK
TIMER
SET
SLEEP
FILTER RESET
RESET
ON OFF
HEAT
Fan operation
About FAN operation:
FAN operation refers the air conditioner does not perform COOLING and HEATING operation, but FAN operation. In this mode, the air conditioner cannot perform AUOT FAN operation, and does show the temperature value on the wire controller.
Turn on the unit
Press the ON/OFF button to turn on the unit
The LCD display of the wire controller will show the previous working state (except for Timer, Sleep, Swing mode), the operation indicator light on the wire controller will light up.
2
1
Choose of working mode
Press MODE button, each press the working mode will change as the following sequence:
choose FAN operation
Adjusting FAN SPEED
Press the FAN SPEED button to change fan speed:
3
4
Turn off the unit
Press the ON/OFF button to turn off the unit.
The wire controller only shows the clock and room temperature.
Choose the desired fan speed
COOLING
DEHU
AUTO
HEATING
FAN
6
AUTO COOLING DEHUMIDIFYING HEATING FAN
AUTO
LOW FAN MED FAN HIGH FAN AUTO
MODE FAN SWING
TEMP
CLOCK
TIMER SLEEP
HEAT FILTER RESET
SET
RESET
ON/OFF
Hints:
The wire controller can memorize the working condition of each time. When start the unit for the second time, just need to press ON/OFF button, the air conditioner will work according to the previous working mode. (except for Timer, Sleep and Swing)
Operation instruction
Auto/Cooling/Dehumidifying/Heating operation
Turn on the unit
Press the ON/OFF button to turn on the unit The LCD display of the wire controller will show the previous working state (except for TIMER, SWING, SLEEP mode). The operation indicator light on the wire controller will light up.
3
1
Choose of working mode
Press MODE button, each press the working mode will change as the following sequence:
then choose AUTO, COOLING, DEHUMIDIFYING, HEATING operation.
Set temperature
*Each press , the set temperature will increase 1 degree. *Each press, the set temperature will decrease 1 degree.
Set the desired temperature.
Press the TEMP. SET button
Adjusting FAN SPEED
Press the FAN SPEED button, for each press, the fan speed will change as the following sequence:
Choose the desired fan speed.
In Heating operation, after start the unit, the air conditioner will sending warm air a moment later to prevent the cold air blowing out. In Dehumidifying, when the room temperature drops 2* higher than the set temperature, regardless the set fan speed, the air conditioner will intermittently operate in low fan speed.
4
5
Turn off the unit
Press the ON/OFF button to turn off the unit.
The wire controller only shows the clock and room temperature.
2
Set temperature + 2* Set temperature
When room temperature reaches set temperature + 2*, the unit will operate in mild dehumidifying operation.
Ultra-low air flow
When room temperature is higher than set temperature, unit in COOLING operation.
7
l
Note:
l
l
l
l
MODE FAN SWING
TEMP
CLOCK
TIMER
SET
SLEEP
HEAT
FILTER RESET
SET
RESET
ON/OFF
Operation instruction
Sleep operation
Use of SLEEP function
After turning on the unit, setting the working mode, then press SLEEP button to make the air conditioner have the previous Sleep time (powered on for the first time or after performing Sleep is 1h). The Sleep symbol will appear. Press time */* button, you can choose between 1~8h. Each press, it may increase/decrease 1h and will display in the humidity area with ì xhî , and display ì Timer Offî in Timer Off area and the time to turn off; press Sleep button again to cancel Sleep function. The Sleep symbol disappears.
Before going to bed, you can press the SLEEP button, the air conditioner will operate in comfort sleep mode to make you have a sound sleep.
Before using this function, you
should calibrate the clock first, otherwise, the SLEEP function will be out of order.
2.In HEATING operation
1 hour later in SLEEP operation, the temperature will decrease 2* from the set temperature, another 1 hour later increase another 2*, then the unit will operate continuous at this temperature for 3 hours, then it increases 1*, after operating at this temperature for another 3 hours, the unit will turn off automatically. The temperature is lower than set temperature to prevent you from feeling uncomfortable during sleep.
3.In AUTO operation
The air conditioner will perform the relative SLEEP operation according to automatically chosen operation mode.
4.In FAN operation
Cannot use SLEEP function
Operation modes
1.In COOLING, DEHUMIDIFYING operation
1 hour later in SLEEP operation, the temperature will increase 1* from the set temperature, another 1 hour later increase another 1*, then the unit will operate continuous for 6 hours, then it turns off automatically. The temperature is higher than set temperature to prevent you from getting a cold.
After setting Sleep function, it is not permitted to adjust clock. The Sleep time is less than 8h, after reaching the set time, the unit will automatically stop. Set Sleep function after setting ì Timer Offî function, the air conditioner will perform Sleep function. After setting Sleep function, the Timer function cannot be set. Set Sleep function after setting ì Timer Onî function, the Sleep function can only be set in the set time of Timer On.
in COOLING* DEHUMIDIFYING operation
Set temperature
SLEEP operation starts
SLEEP operation stops
turn off
1 hour
about 6 hours
increase 1*
1 hour
increase 1*
Set temperature
SLEEP operation starts
SLEEP operation stops
turn off
1 hour
about 3 hours
3 hours
decrease 2*
increase 1*
in HEATING operation
1 hour
decrease 2*
8
Timer On/Off function
Operation instruction
OFFON OFFON
AM
PM
AM
PM
TIMER ON TIMER OFF TIMER ON-OFF
Blank
MODE FAN SWING
TEMP
CLOCK
TIMER
SET
SLEE
E TER RESET
ROOM
RESET
ON/OFF
Before using TIMER function, calibrate the clock first (referring to page 4). When you wake up in the morning, before going back to home after work or after going to bed, you can let your air conditioner automatically turn on or turn off.
2.Set of TIMER mode
Press the TIMER button to change the TIMER mode, each press the TIMER mode will change as the following sequence:
1.Turn on the unit
Cancel TIMER
Press the TIMER button several times until the TIMER mode display disappears.
After turning on the unit, set the desired working mode. The LCD of the wire controller will show working mode. (except for Timer, Sleep, Swing)
* Each press, the set time increases 10 minutes. If depress the button, the
time will increase rapidly.
*Each press, the set time decreases 10 minutes. If depress the button, the time will
decrease rapidly.
3.Set time
Press the time adjusting button
This LCD will show the time set, the time can be adjusted within 24h. (AM stands for morning, PM stands for afternoon).
4.Confirm the time After calibration of the clock, press SET button to confirm time.
The time displayed is: at x oíclock x minutes the unit will be turned on (TIMER ON) or turned off (TIMER OFF).
Hints:. After power failure, the clock should be calibrated again. The wire controller has memory function, when you use this function for the second time, if the time set is the same as the previous one, you just need to choose the TIMER mode then press the SET button to confirm.
At this time, the* or* ill not flash.
ON
OFF
Then choose the timer mode as you need (TIMER ON or TIMER OFF.) At this time the or will flash.
ON
OFF
" " " "
9
OFFON OFFON
AM
PM
AM
PM
TIMER ON TIMER OFF TIMER ON-OFF
Blank
ON
Then choose the TIMER ON-OFF mode. At this time the" "will flash.
*
*
At this time, the" "will not flash.
OFF
MODE FAN SWING
TEMP
CLOCK
TIMER
SET
EEP
EAT R RESET
ROOM
RESET
ON/OFF
Operation instruction
Timer On-Off function
Cancel TIMER
Press the TIMER button several times until the TIMER mode display disappears. According to the sequence of TIMER ON & TIMER OFF setting, you can realize turning on unit first, then turning off unit.
After adjusting time, press SET button to confirm time.
The time displayed is: at x oíclock x minutes the unit will be turned on.
At this time, the" "will not flash ," "begins to flash.
5.Set the TIMER OFF time
Press the TIME button, the adjustment method is the same as the one of setting TIMER ON time.
6.Confirm the time of TIMER OFF
After adjusting time, press SET button to confirm time.
The time displayed is: at x oíclock x minutes the unit will be turned off.
ON
OFF
2.Set of TIMER mode
Press the TIMER button to change the TIMER mode, each press the TIMER mode will change as the following sequence:
1.Turn on the unit
After turning on the unit, set the desired working mode. The LCD of the wire controller will show working mode. (except for Timer, Sleep, Swing)
Each press, the set time increases 10 minutes. If depress the button, the time will increase rapidly. Each press, the set time decreases 10 minutes. If depress the button, the time will decrease rapidly.
3.Set time
Press the time adjusting button
This LCD will show the time set, the time can be adjusted within 24h. (AM stands for morning, PM stands for afternoon).
4.Confirm the time
10
Usersí Attention
Set proper room temperature
Not too low or high and make every peop­le in the room feel comfortable.
Do not let the cold air blows directly to human body for a long time and do not make the room temperature drop too low.
Otherwise, it may cause uncomfortable or bad to your health.
Cut off power
The room should often ventilate.
After a long-time of using air conditioner, the room must be ventilated.
Do not keep the doors and windows open
Otherwise, it may lower the efficiency of the air conditioner.
Television, radio and acoustics, etc. equipment should keep over 1m from indoor unit and wire controller.
Otherwise, they may disturb the image and cause noise.
If do not use the air conditioner for a long time, it is necessary to cut off power.
If do not cut off power, the unit may consume power. In order to protect the unit, before using the air conditioner again, turning on the power at least 12 hours in advance.
The windows should be hung with curtains or blinds.
Do not let the sun shine directly shine in the room; do not let the outdoor air enter room.
The articles must keep dry cannot be put under the indoor unit.
When the humidity is over 80% or the drainage outlet is blocked, the indoor unit may drop water.
Do not put articles around the air inlet and outlet.
This kind of obstacle can lower the efficiency of the air conditioner or cause unit trouble.
The air conditioner can only be used in air conditioning. It can not be used in other purpose.
Do not use the air conditioner in some specific purpose, such as storage or protect food, animals, plants, precise instrument and artwork, otherwise, the quality of them may be declined.
Do not press tightly with the LCD part of the wire controller to avoid damage of it.
The airflow cannot directly blow to the pets and plants.
Otherwise, pets and plants may be hurt.
Do not put any drying devices under the indoor unit.
The heat may cause the deformation of indoor unit.
Cooling is 26~28*
Heating is 18~23*
11
Maintenance
Disconnect power supply Don't touch it with wet
hand
Don't wash with hot water or solvent to clean the unit
Don't use hot water over 40 C, as this may cause damage to air filter. Wipe air filter carefully.
Clean it with warm and wet cloth or with neutral detergent, then wipe it dry with clean and soft cloth. If air conditioner is very dirty, clean it with cloth soaked in neutral detergent,then wipe off the detergent with clean water. Don't use water higher than 40 C , which will cause discoloring and deformation. Don't use insecticide or other chemical detergents.
Caution:
Indoor and outdoor cleaning
Use water or vacuum cleaner to clean it. If it is extremely dirty, wash it with neutral detergent or soap water. Wash it with clean water and install it after complete dry.
Air filter cleaning
40*
First cut off the power supply, then turn the embedded part of air inlet grille upwards, finally use cross-shaped screwdriver to screw off the screw.
12
40*
Remove air inlet grille
Maintenance
After season maintenance
Before season maintenance
13
Let the unit run in Fan mode for half a day in a fine weather to dry completely the unit inside.
Turn off the unit and pull out power plug.
There might be certain power consumption even if unit is stopped.
Clean air filter and indoor unit, cover outdoor unit after cleaning.
Check if there are obstacles at inlet and outlet of indoor and outdoor unit, whick will reduce unit efficiency.
To protect compressor at start, please connect external power supply to the unit 12 hrs prior to starting. Also please keep the power supply switch ON during the whole season.
Don't fail to attach air filter after making sure it is cleaned. Dust will enter into unit causing damages or faults if it is running without air filter.
Trouble shooting
Followings are not problems
Sound of water flowings are not
problems.
Sound of cracking is heard.
Smells are generated.
During operation, white fog or steam
comes out of indoor unit.
In cooling operation, unit switches to fan
operation.
Unit will not restart after stop.
Won't start?
No outlet air or fan speed can't be changed in
dry mode.
In heating operation, water or
steam are blown out of indoor
unit.
In heating operation, indoor fan won't stop even
if unit is stopped.
During unit start and operation or at stop, a swishing or gurgling noise may be heard. This noise is generated by refrigerant flowing in the system.
During unit operation, a cracking noise may be heard. This noise is generated by the casing expanding or shrinking because of temperatuer changes.
This is because the system circulates smells from the interior air such as the smell of cigarettes or the painting on the unit.
When unit is running at places like restaurant where dense edible oil fumeis always exist, this will happen.
To prevent frost from accumulating on indoor heat exchanger, unit will switch to fan operation for a while then resume cooling operation.
Though ON/OFF button is set to ON, unit won't resume cooling,dry or heating operation in 3 min after it is stopped, this is because of 3­min-delay protection circuit.
Unit will reduce fan speed repeatedly and automatically if room temp. is too low in dry operation.
This occurs when frost accumulated on the outdoor unit is removed. (during defrosting operation)
After unit stops, indoor fan will go on running until indoor unit cools down.
Please wait 3 minutes
14
When problems occur?
Before ask for services, please first check your unit against following.
Air conditioner won't start.
Is power supply switch turned on?
Power supply switch is not set at ON.
Are operation controlls adjusted correctly as specified?
Are horizontal louvers at up position (in heating mode)?
Is there any direct sunlight in the room?
Poor cooling or heating
Poor cooling
Is city power supply normal?
Is air filter too dirty?
Any doors or windows left open?
If there are unexpected heat sources in the room?
Are there any obstacles at inlet or outlet grill?
Too many people in the room?
Is leakage current breaker activated?
This is very dangerous, please disconnect power supply immediately and contact your dealer.
If your unit still can't work properly after above mentioned checks, or following problems occur,
please stop it immediately and contact your dealer.
Fuses or circuit breakers often blow out.
Water comes out in cooling/dry operation.
Operation is abnormal or sound is heard.
Proper temp
Power failure?
The fuse type on indoor unit PC board is T3.15A/250V. The fuse type of fan controlle wire is T3.15A/250V. The fuse type on outdoor unit PC board is T6.3A/250V.
15
E4
If finding any abnormal phenomena (e.g. smell of burnt), please cut off power and ask help for after sales
service personnel.
Warning
If still use the air conditioner under this condition, the unit may be damaged and maybe cause electric shock or fire, etc. accidents.
When Troubles Occur
Find the following troubles occur, please stop the unit and cut off power, then contact the after-sales service worker.
The fuse and creepage breaker are often blown out;
In Cooling or Dehumidifying operation, there is water leakage;
The screen on the wire controller shows trouble code (E0, Ö E9), which indicates the air conditioner has trouble.
Cut off power
E3
E5
The trouble of outdoor coil/ compressor air out temperature sensor
The trouble of electric current overload / power item order
E8
The communication trouble between panel and indoor panel
E2
The trouble of outdoor ambient temperature sensor
E1
The trouble of indoor ambient temperature sensor
The trouble of indoor coil temperature sensor
E9
The communication trouble between indoor panel and outdoor panel
16
After taking the following measure, please contact the commissioned service center.
or the operation switch works abnormally.
Tell the displayed contents of the wire controller to your commissioned service center.
Cut off power and inform your commissioned service center.
Note: The trouble code will be displayed in the temperature display area.
Symptom
E6
High / Low pressure protect
Installation instruction
Before installing, do read this ì Safety precautionsî carefully to guarantee the proper installation. The below attentive matters are divided into ì Warningî and ì Noteî two parts. When the wrong installation occur, it is very possible death and severe injury and other serious accidents will happen. For those items are listed in ì Warningî part. But even the items listed in ì Noteî part can also cause serious accidents. Above all, both the two parts are very important contents related to safety, so they must be obeyed. After finishing the installation work, do test run to verify everything is normal. After that please explain the using and maintenance methods to the user. Additionally, give this installation manual and operation manual to the user and ask them to keep it properly.
The commissioned repair center shall do the installation work. If you do the installation work by yourself, the improper installation will cause water leakage, electric shock fire and other accidents. The installation work shall be in line with what the installation manual specified. If installation is not proper, water leakage, electric shock, fire and other accidents will occur. Install the air conditioner to a place where can definitely stand its weight. The air conditioner can not be installed on a nonmetal bracket (such as theft guard net). Places not firm enough will cause drop down of unit resulting in body hurt. The installation work shall be preventive to typhoon and earthquake. If the installation work is not met with the requirements, overturn of the unit will occur resulting in accidents. Using the specified cable to do wiring work and connecting firmly and properly. Fix the connecting part of the terminals to prevent it from the external force. Improper connection and fixing will cause heating and fire etc. accidents. Wiring shall be kept in correct shape avoiding extrusion. After installation, the electric box cover and the external panel shall not nip the wire. Improper installation will cause heating and fire etc. accidents. When setting or moving the air conditioner do not let the air and things alike get into the refrigeration system except the specified refrigerant (R22). If air and other things enter, abnormal high pressure will occur, which easily cause break and body injuries etc. accidents. When installing, do use the accessories or specified parts. If not using the parts specified by our company, water leakage, electric shock, fire and refrigerant leakage will occur. Do not lead the drain hose to drain where the sulfur gas may be involved. Otherwise, the poisonous gas will enter into the indoor. During installation, if refrigerant leakage occurs, do the ventilation work immediately. As soon as the refrigerant gas meets fire, poisonous gas will be produce. After installation, confirm there is no leakage of refrigerant. If the refrigerant gas enters into room and meet the air blowing heater, heater or stove etc. fire source, the poisonous gas may be produced. Do not install the unit in a place where the combustible gas may be leaked. In any case the combustible gas leaks and accumulated around the unit, fire accident will occur. The drain hose should be correctly installed according to the installation manual to ensure smooth drainage, and take proper heat preservation measure to prevent from dew. Improper pipe installation may cause water leakage result in wet the indoor articles. Do heat insulation work to the refrigerant gas pipes and liquid pipes to reach the purpose of heat preservation. If the heat insulation measure is not sufficient, water generated by condensing dew will drip leading to wet the floor and indoor articles.
Do grounding work. Do not connect the grounding wire to gas pipe, tap, lighting rod or telephone line. Improper grounding will cause electric shock. In some places the creepage breaker shall be installed. If do not install the breaker, electric shock may occur. After electric installation, power on them to do electric leakage test.
17
L shaped metal
Fall-prevention fitting metal
Self tapping scerw
Wall hole cover
Piping hole cover
No. QTY
Shape and description
Parts in the following list are accessories for the unit installation which can be used if necessary.
Standard accessories
1. Screw driver 2. Hacksaw
3. 70mm dia. hole core drill 4. Spanner (dia. 17, 27mm)
5. Spanner (14, 17, 27mm) 6. Pipe cutter
7. Flaring tool 8. Knife
9. Nipper 10. Gas leakage detector or soap water
11. Measuring tape 12. Reamer
13. Refrigerant oil 14. Lead-solder tool
Following parts shall be field supplied
Mark
Parts name
Adhesive tape
Pipe clip
Connecting hose
Insulation material
Putty
Drain hose
A
B
C
D
E
F
Wooden bolt
1
5
1
2
3
4
5
6
2
2
1
2
Installation instruction
Notice
Warning
This manual can not include all kinds of conditions, if you have new requirements and questions, please contact with local Haier Sales Center.
Before installing the unit, please read this manual carefully. Improper installation may cause accidents and make unit damage or death.
Installation tools
18
Installation procedure
Select the firm place that will not influenced by vibration and can bear the weight of the unit Select the place with easy drainage and place can perform outdoor unit pipe connecting. Select the place far away from heat source, vapor source and direct sunshine to avoid the causing of the trouble in operation parts and the deformation of the casing. Select the place where the cool air or warm air can evenly spread to every corner of the room. Select the place near power receptacle leaving sufficient space around the unit. (Referring to installation diagram)
Place with oil fog splash and much vapor (e.g. mechanical plant and kitchen, etc.) to prevent heat exchanger from performance lowering and plastic parts from corroding to damage. Place may generate or keep corrosive gas (sulfur dioxide, etc.), flammable gas (diluent, gasoline, etc.) to prevent heat exchanger from corroding, plastic parts from damage and flammable gas from causing fire accident. Hospital, etc. places near the machine generates electromagnetic wave or high frequency signal to prevent the mixed wave from causing wrong action of the control parts. Place can be blown by the sea wind (coastal area) to prevent the casing and heat exchanger from corroding.
19
19
1. Before installation
[Before finishing installation, do not throw the attached installation parts away.]
2. Selection of installation place
3. Installation space
(Indoor unit) please keep the spaces larger than the following dimension.
Avoid the following installation places
Unit (mm)
50
50
50
600
1000
600
600
Confirm the route to carry the units to the installation place. Do not remove the package of the unit, before carrying it to the installation place. When have to remove the package, use a soft material or protection board with rope to lift the unit to prevent the unit from damage or bumping scrape.
Installation of indoor unit
Selection of installation place Place where it is easy to route drainage pipe and outdoor piping. Place away from heat source and with less direct sunlight. Place where cool and warm air could be delivered evenly to every corner of the room. Place near power supply socket. Leave enough space around the unit (refer to installation drawings).
Fixing of the unit
Position of the wall hole Wall hole should be decided according to installtion place and piping direction. (refer to installation drawings) Making a wall hole Drill a hole of 70mm dia. with a little slope towards outside. Install piping hole cover and seal it with putty after installation.
1.
2.
Fixing of indoor unit
To prevent it from fall off, please fix the unit with fall-prevention fitting at wall and L-shaped metal at floor.
INDOOR
OUTDOOR UNIT
wall hole
wall thinkness
( Cross section of wall hole )
70mm
Self-tapping screw
all-prevention fitting metal (accessory)
Wood screw
L-shaped metal (accessory)
Please install the whole unit horizontally,with a slop of 1 degree at front and rear,left and right.
20
Installation procedure
indoor unit
Installation of fall-prevention fitting metal:
Fix the fitting metal to the wall by screws so that there is no clearance between them. With the unit set up vertically, fix the fitting metal to the unit with screws while making an adjustment at the long portion of the hole so that there is no clearance between the upper surface and the fitting metal.
Installation of L-shaped metal
Fix to the unit by screws so that there is no clearance between the fitting metal and the unit. After confirming that the unit has been set up vertically to the floor, fix it to the floor by bolt.
Piping connection
Connecting method Apply refrigerant oil at half union and flare nut. To bend a pipe, give the roundness as large as possible not to crash the pipe. When connecting pipe, hold the pipe centre to centre then screw nut on by hand,refer to Fig. Be careful not to let sundries, such as sands enter the pipe.
1.
Forced fastening without centering may damage the threads and cause a gas leakage.
Pipe dia Fastening torque
Liquid pipe 12.7mm(3/8")
42N.m
21
Installation procedure
indoor unit
2. Piping connection of indoor unit Arrangement of piping and drainage pipe
After opening inlet grill, you will see a control box as shown in the Fig. Remove the cover before working.
Cut away, with a hammer or a saw, the lid for piping according to piping direction.
According to the piping method, connect the piping on indoor unit with union of connecting pipe. Arrange the piping as per the wall hole and bind drain hose connecting electric cable and piping together with polyethylene tape. Insert the bound piping connecting electric cable and drain hose through wall hole to connect with outdoor unit.
Arrangement of drain hose Drain hose shall be placed in under place. There should be a slope when arrange drain hose. Avoid up and down waves in drain hose.
Indoor unit
Slope
Good
Up
Down
Bad
If humidity is high, drain pipe( especially in room and indoor unit ) must be covered with insulation material.
Insulation material
Copper tube
Drain hose
Connecting electric cable for indoor and outdoor unit
22
Installation procedure
Outdoor unit
Please remove the cover piece on the gas pipe and the screw cap on the liquid pipe.
23
Installation procedure
Outdoor unit
Use attached accessory <A> to connect the on-the-spot connecting pipe and gas pipe.
Main points of installation refrigerant pipe
Please install the gas pipe and liquid pipe according to the following shown method.
* Please connect the connecting pipes between indoor and outdoor unit according to the following method.
a) When introducing the pipe from right side
Use attached accessory <A> to connect the on-the-spot connecting pipe and gas pipe.
b) When introducing pipe from rear side or left side
* After finishing connection of connecting pipe, please do thermal insulation treatment by using the attached thermal insulation material. Otherwise, it may cause water leakage.
Setting of wire controller dial switch
Setting of this series of air conditioner dial switch: 1, ON; 2, OFF; 3, ON; 4, ON.
B
A
A B
Warning
Selection of installation site
It should be installed at places where it is firm enough to withstand the weight of the air conditioner to prevent falling. Typhoon and earthquake prevention. It should be installed according to specific requirements. Inasppropriate installation may lead to accidents.
Note: Obstacles should be 2000mm off the top of the out­ door unit. Obstacles nearby should be 400mm lower than the top of the unit.
1. Handing
As there is no protective package for the outdoor unit,so the following points merit attention: (1) When forklift is used, insert the fork into the holes in the base plate. (2) When crane is used, lift the unit with 4 pieces of steel rope with diameter above 6 mm. (3) Put protective materials between the cable and the unit to prevent deformation and damage of the surface.
2.Mounting
(1) The distance between two connections must not be less than 20mm.
(1)During installation, connect the outdoor unit and align the mounting surface(See the figure on the right).Mount the electric distribution device on the external side of the unit in accordance to the installation instructions for electric distribution device. (2)To ensure good performance of the machine and facili­ tate installation and maintenance, adequate space must be reserved (See figure on the right).
Installtion space
24
Installation procedure
Outdoor unit
Blow out
Absorb in
Absorb in
Absorb in
Working, repair surface
Over 300mm
Over 20mm
Over 20mm
Over 20mm
Over 20mm
Over 1000mm (front side)
Wire rope
Protection cushion
Base panel
Wire rope
M12 foot screw bolt
4 screws each unit
Refer to the following figure for the distance between the foundation bolts.
(2)When the refrigerant pipe is connected from the bottom of the unit,the unit should be raised at least 500mm(see the figure below)
(3)In snowy regions,snow-proof facilities should be used(see the figure below). (Poor snow-proof facilities may lead to damge.To avoid inconveniences,the unit should be raised and snow-proof covers should be installed at the air inlet and outlet.)
(4)During installation,anti-vibration rubber pads should be used between the machine and the bracket.
3.Connection of refrigerant pipe
During installation,if refrigerant leakage occurs,ventilation measures must be taken.When refrigerant meets with fire,hazadous gas will be produced. After installation,make sure that there is no refrigerant leakage. Refrigerant,if meeting with heaters and stoves,ect in the room,may produce hazardous gas.
Connection of refrigerant pipe
(1) The joints of the refrigerant pipe are inside the unit.Take off the access hole cover in front of the unit. (2) The pipe can be connected from the front or bottom of the outdoor unit. (3) Remove the L-shaped pipe from the valve by welding and connect the accessory pipe to the valve. (4) In the case of front connection,cut the accessory pipe at the height of the fixing panel.Then join the pipe with an elbow and let it go through the fixing panel.For the convenience of maintenance,bend the pipe down (once) and then connect pipe to the right or left. (5) In the case of bottom connection,join the pipe with accessory pipe through the holes in the base plate of the outdoor unit,and connect pipe the left or right or the back.
Warning
Air inlet snow-proof cover
Air outlet snow­proof cover
Air inlet snow­proof cover
25
Installation procedure
Through hole(15x20)
1100
Outdoor unit
Refrigerant tube
Above 500mm
(6) During welding,the gas pipe valve must be cooled down with a wet cotton cloth.
During welding of the distribution pipe
1.In case of brazing weld of joint,nitrogen must be filled in the pipe to prevent oxidization.
2.The refrigerant pipe should be newly-made and clean.During installation,do not let water and other substance into the pipe.
3.Use two spanners to tighten the connecting nut.One spanner will make loose connection.
The torque moment should conform to the specified value.(Refer to the below)
Selection of tube material and size Determinaltion of tube diameter (Refer to the diagram on next page for steps 1,2,3,4 and 5 below)
1.Tube between the outdoor unit and the first bypass(main tube):
The diameter of the main tube and the outdoor tube should be the same.
2. Tube between bypasses(sub-tube):
The diameter of the sub-pipe is determined according to the total capacity of all the connected indoor units.But if it is larger than the capacity of the outdoor unit,the diameter should be determined according to the capacity of the outdoor unit.
Tube diameter
(mm)
12.70
Torque moment for
pre-installation (N.m)
49.0(5.0kgf m)
Torque moment for tightening the nut
Torque moment for
tightening up (N.m)
53.9(5.5kgf m)
Base plate
Tube to the tight
Tube to the back
Access hole cover
M4
M6
Tube fixing panel
Tube to the left
Tube to the left
Tube to the tight
26
Installation procedure
Outdoor unit
Matters needing attention
Never use oxygen,flamable and poisonous gases for the leak test.
Step 1:Charge for more than 3 minutes under 0.3MPa(3.0kg/cm
2
g)
Step 2:Charge for more than 3 minutes under 1.5MPa(15kg/cm2g)
--Serious leakage may be found. Step 3:Charge for more than 24 hours under 3.0MPa(3.0kg/cm2g)
--Small leakage may be found.
Check for pressure decrease
Without pressure decrease-Pass With pressure decrease-Check for leaage.
There will be a 0.01MPa(0.1kg/cm
2
g) pressure change for every 1 C ambient temperature change during
the 24-hour pressure charge.It should be corrected during the test.
Field tube installation
Field tube installation
To the unit
To the unit
(Gas side)three way valve
(Gas side )access hole
Detailed diagram of the three-way valve
To the gauge distributor
(Liquid side)access hole
Three way valve fully closed liquid side
6.4
6.4
Copper pipe
Relief valve
Nitrogen bottle
VL VH
Gauge distributor
High pressure gauge
Low pressure gauge
Three way valve fully closed(gas side)
Solder joint
Solder joint
Tightly closed
Indoor unit
Indoor Outdoor
Access hole
Copper pipe
Solder joint
Tightly closed
Tightly closed
Access hole
Outdoor unit
(Liquid side)three way valve
27
Installation procedure
Outdoor unit
In the case of pressure decrease during steps 1 to 3 ,check the joints with the ear,hand or soapsuds for leakage.Repair it by welding or tighten the connecting nut up.
Use vacuum pump to evacuate the air.Never use the refrigerant for the evacuation. Drain off the nitrogen gas after the leak test and then connect the vacuum pump as shown in the figure below. The vacuum pumping must be done from both the liquid and gas inlets.
Check for leakage
Vacuum Pumping
Use a vacuum pump with high degree of vacuum(below-755mmHg) and large volume displacement (above 40L/min) The pumping time depends on the length of the connecting pipe.Generally,it takes about 2-3 hours. Make sure that the Y-shaped valves on both the gas and liquid sides are closed before pumping. If the vacuum can no reach-755mmHg within 2 hours,continue pumping for another 1 hour. If the vacuum can no reach-755mmHg after more than 2 hour's pumping,close the valves V
L
and VH on the gauge distributor and stop pumping.One hour later,check the vacuum again.If the vacuum has changed,it means there is a leakage.Repair it. After the above steps,replace the vacuum pump with the refrigerant pump and refill refrigerant.
To the unit
To the unit
(Gas side)three-way valve
(Gas side )access hole
Detailed diagram of the three way valve
To the gauge distributor
(Liquid side)access hole
Three-way valve fully closed liquid side
6.4 Copper pipe
Vacuum pump
Gauge distributor
High-pressure gauge
Low-pressure gauge
Three-way valve fully closed(gas side)
Solder joint
Solder joint
Tightly closed
Indoor unit
Indoor Outdoor
Access hole
Solder joint
Tightly closed
Tightly closed
Access hole
Outdoor unit
(Liquid side)three-way valve
Field tube installation
Field tube installation
P
28
Installation procedure
Outdoor unit
Refill refrigerant
When the outdoor valve is shut,fill the refrigerant from the access hole at the gas and liquid sides. If the required filling is impossible,open all the gas and liquid valves,then slightly shut the gas valve, run the compressor and fill the refrigerant from the access hole at the gas side.Now adjust the gas valve to control the refrigerant flow,which will be gasified during absorption by the system. If there is insufficient refrigerant in the system caused by leaks,refill it after the remaining refrigerant is recollected.
Open all valves
Open all the valves of the outdoor unit.
Heat isolation of the pipes
Separate isolation should be made for the liquid and gas pipes. Materials used for the pipe isolation at the gas side must withstand above 120 C temperature.
Refilling of refrigerant
After the vacuum pumping,replace the vacuum pump with the refrigerant pump and refill refrigerant. Calculation of refrigerant quantity The factory filled refrigerant into the piping excludes the part of pipes according to be refilled on the site. Refill the amount of refrigerant into the piping according to the following formula. The factory filled refrigerant is listed in the table below:
The quantit of the refrigerant to be refilled during installation depends on the diameter and length of the liquid piping.
The quantity of the refrigerant t be refilled on the site=Actual length of liquid tube x quantity of refrigerant to be refilled for per meter of liquid pipe.
Adding refrigerant
Refrigrant must be added in liquid state. Refrigerant bottle swith or without a siphon tube can be refilled with refrigerant upright or upside down,Respectively.
Containers for R407C refrigerant must be marked with R407C and a brown Stripe. R407C and R22 refrigerant cannot share the same instrument distributor and filling pipes.
29
Installation procedure
Outdoor unit
Note:
All the wires should be copper core wires. The power cable of indoor unit should be equipped according to the operation manual of indoor unit. Before finishing vacuumizing the refrigerant pipe system, do not supply power to indoor unit. When connecting the indoor & outdoor wire, check the number of the indoor & outdoor terminals, the terminals with the same number connected together with one wire. Incorrect wiring will damage the controller of the air conditioner or make the unit work abnormally. The air conditioner must use special power circuit and special air switch (50-60A), groundign wire. The wiring work should be done by a qualified electrician according to the national wiring rule. The creepage breaker must be installed. The grounding line and the neutral line of the receptacle must be strictly separated. It is incorrect to connect the neutral line with the grounding line.
The connection type of power cord is YZV connection. The parameter of connecting wire is:4x1.5mm. The above standard wiring is no more than 5m. When the langth of the wire is more than 5m, please
overstriking wire. If the soft power cord is damaged, to avoid risk, it must be replaced by the manufacturer or their specific repair department or similar professional worker.
(Sketch map)
2
R
S
T
N
Power supply: 3N~,380-400V,60Hz
Note: The terminal blockís mark at the two ends of the connection wire should be corresponding one by one, otherwise the air conditioner cannot work normally.
Installation procedure
Electric wiring
Connect wire between indoor & outdoor unit
As the wiring diagram show to arrange the connection wire.
2.The wiring method of straight terminal
For those connection wires whose end are not orbicular terminals, their wiring method is:
Loosen the connecting screw, insert the end of the wire directly into the terminal block, and then tighten screw. Pull the wire outwards slightly to confirm it is held tightly.
3.Pressing method of connection wire:
After wiring, the connection wire must be pressed with wire holding clamp. The wire holding clamp should press on the out cover of the connection wire. As the right figure shown:
The wiring method of orbicular terminal
Wiring method
1.The wiring method of orbicular terminal
For the connection wire which end is orbicularterminal, its wiring method is as the right figure shown. Dismantle the screw and put it through the ring at the end of the connection wire, then connect it to the terminal block and tighten the screw.
Correct pressing
30
Terminal block
Wire holding clamp
Wrong pressing
1
2
3
Terminal block of indoor unit
1
2
3
Terminal block of outdoor unit
Terminal block of outdoor unit
1. Power supply
Air conditioner must use an exclusive line (over 30A) When installation air conditioner in a wet place, try to use a circuit breaker against Current leakage. For installation in other places, use circuit breaker as far as possible.
Installation inspection and test run: Please operate unit according to this Manual. Items to be checked during test run. Please made a " "in " "
Are there any gas leakage? How is insulation at piping connection carried out? Are electric wires of indoor and outdoor unit firmly inserted into terminal block? Is electric wiring of indoor and outdoor securely fixed? Is draminage securely carried out? Is earth line ( grounding ) securely connected? Is power supply voltage abided by the code? Is there any noise? Is control display normal? Is cooling operation normal? Is room temp. regulator normal?
A
Flaring tool
Pipe dia. Dimension A(mm)
Liquid pipe 12.7mm (1/2") 1.2 ~ 2.0
2. Pipe cutting and flaring Be sure to carry out deburring after pipe cutting with a pipe cutter. Insert flaring tool to make a flare.
Correct
Lean Damaged flare Crack Partial Too outside
Incorrect
Such means for disconnection must be incorporation in the fixed wiring
The breaker of the air conditioner should be all-pole switch ; and the distance between its two contacts should be no less 3 mm.
The power supply:3N,380V~,60Hz. The parameter of power cord is over 5x6mm . The above standard wiring is no more than 5m. When the langth of the wire is more than 5m, please overstriking wire.
2
Others
31