Haier AP88NACBEA, AU88NATBEA Operation Manual

Cabinet unit
Operation Manual
AP88NACBEA AU88NATBEA
No.0010573003
Operation points Name of Parts Safety Precautions Operation instruction Users' Attention Maintenance Trouble shooting When problems occur When troubles occur Installation instruction Installation procedure Others
1 2-3 4-5 6-10 11 12-13 14 15 16 17 18-30 31-32
CONTENTS
R
MODEFANSWING
TEMP
CLOCK
TIMER
SET
SLEEP
FILTER RESET
RESET
ON/OFF
Change of fan speed
In COOLING mode, the air sending is set at AUTO, when the indoor temperature is near the set temperature, the fan speed will lower automatically.In HEATING mode, when room temperature reaches the set temperature, the compressor will stop running, and the fan will change to LOW FAN or stop.
In DEHUMIDIFYING mode,
the fan speed will change automatically.
3-minute protection function
If start the unit immediately only after it is turned off, the compressor will start after 3 minutes have elapsed to protect the compressor.
Operation of air conditioner
When the ambient humidity is too high, in COOLING or DEHUMIDIFYING mode, there may be water dropped in the air outlet.
Anti-cold air blowing out
During Heating operation, after starting the unit, the indoor fan motor will not rotate immediately to prevent cold air from blowing out.
Defrosting function
During Heating operation, when frost formed on the heat exchanger of outdoor unit, the air conditioner will defrost automatically for several minutes. During defrosting, both the fan of indoor and outdoor unit do not run. After finishing defrosting, the air conditioner will automatically resume operation.
Hint
When the air conditioner is in Heating mode, it absorbs heat from outside and release to indoors. So the outdoor temperature may affect the Heating effect.
Power failure resume function (please set and use this function according to actual
condition)
After setting power failure resume function, if there is a sudden power failure during unit operation, when power on for again, the unit will resume the previous state.
Setting method: when the wire controller is in ON state (except for TIMER and FAN
mode), press the SLEEP button for 10 times in 5 seconds, after the buzzer sounds 4 times, the unit will change to POWER FAILURE RESUME function. Cancellation method: press the SLEEP button 10 times in 5 seconds, after the buzzer 2 times, the POWER FAILURE RESUME function is cancelled.
Note: After the unit is set POWER FAILURE RESUME function, if there is a sudden power failure
in using, during this period of time if there is no need to use the unit for a long time, please cut off power to prevent the air conditioner from automatically resuming to the previous setting if powerfailure resumes, or press the ON/OFF button to turn off the unit after power failure resumes.
Operation points
1
?
MODEFANSWING
TEMP
CLOCK
TIMER
SET
SLEEP
FILTER RESET
RESET
ON/OFF
MODEFANSWING
TEMP
CLOCK
TIMER
SET
SLEEP
FILTER RESET RESET
ON/OFF
MODEFANSWING
TEMP
CLOCK
TIMER
SET
SLEEP
FILTER RESET RESET
ON/OFF
MODEFANSWING
TEMP
CLOCK
TIMER
SET
SLEEP
FILTER RESET
RESET
ON/OFF
Outlet grill
Operation panel
Inlet grill
Indoor unit
Outdoor unit
Air inlet
Air inlet
Air inlet
Air outlet
Name of Parts
The interface of the refrigerant pipe
2
Note:
Open the power switch 12 hours before the unit running.Do not cut off the power when short time stop the unit (like one day and one night ),this is to protect the compressor. Do not block the air inlet and air outlet, otherwise the performance of the air conditioner may be lowered and it will make the protection device act.
MODEFAN SWING
TEMP
CLOCK
TIMER
SET
SLEEP
FILTER RESET
RESET
ON/OFF
Name of Parts
Wire Controller
14.Network control display
Used to adjust the time of timer and clock
When the wire controller appears abnormal condition, use a sharp-pointed article to press this button to make the wire controller resume normal
After cleaning the air inlet, press this button, the unit can start to operate
12.Humidifying state display
Used to turn on/off unit
1.ON/OFF button
6.Air filter cleaning display
*
7.Super/Soft operation display
13.Sleep state display
2.Temperature display
24.Time Adjusting button
23.Sleep button Used to set Sleep
state or Power Failure Resume Function
When there is too much dust collected on the air inlet, the wire controller will show this display to remind the user to clean the air inlet. After cleaning and installation, just press the air filter reset button.
8.Fan speed display
9.Auto Swing display
11.Fresh air state display
25.Reset button
26.Air Filter Reset button
27.Timer button
Used to set the mode of timer
29.Lock state display
28.Electric heating button
4.Timer ON/OFF display
3.Clock display
17.Operation mode button
5.Humidity display
22.Setting button Used to confirm
the time of timer and clock
15.Working mode display
21.Clock button Used to calibrate the time of timer and clock
16.Electric heating display
Used to set working mode: Auto, Cooling, Dehumidifying, Heating, Fan
18.Fan speed button Used to set fan speed: Low Fan, Med Fan, High Fan, Auto
20.Temperature Setting button
10.Health state display
Used to set temperature, temperature range: 16*~30*
19.Swing button
Used to set Auto Swing or Fixed air sending direction
Note:
1.This model does not have the following related display and function
2.Non-electric heating type, there is no electric heating button and electric heating
display
* * 10 11 12
28
16
6
Auto
Low Fan Med Fan High Fan Auto
Working mode
Auto operation
Cooling operation
Dehumidifying operation
Heating operation
Fan operation
Wire controller
Calibration of clock
When turning on the unit for the first time, the clock should be calibrated. The method of calibration is:
1.Press ì Clockî button, the Clock display ì AMî ì PMî will flash.
2.Press * or to adjust time. For each press, the time will increase or decrease 1
*minute. If depressing the button, the time will increase or decrease rapidly.
3.After confirming the time, press ì Setî button, ìAMî or ìPMî will stop flashing,
*the clock will begin to work.
*
SET
ROOM
AUTO
29
3
MODE FAN SWING
TEMP
CLOCK
TIMER
SET
SLEEP
FILTER RESET
RESET
ON/OFF
HEAT
Safety Precautions
Before starting the unit, please read the following ì Safety Precautionsî carefully to guarantee the normal operation of the system. The following lists two kinds of safety precautions ì Warningî and ì Noticeî . For the items that the improper use may cause death or serious injury are listed in ì Warningî volume. However, sometimes the items listed in ì Noticeî volume may also cause serious accidents.
So, these two volumes are the important contents related
to safety, they
must be observed.
Installation Safety Precautions
Warning
The system should be applied to places as office, restaurant, residence and the like.
The system should be installed by your dealer or a professional installer.
Application to inferior environment such as workshop, it may cause equipment malfunction and serious injury or death.
Installation by yourself is not encouraged. Because improper installation could cause water leakage, electric shock and fire accident.
Notice
Operation safety precautions
Do not let the cold wind blow to human body for a long time.
When any abnormal condition (scorching smell or others) is found, stop operation immediately and turn off the power switch. Then consult your dealer.
Warning
It may affect the physical condition or cause some health problems.
If continuing the operation without removing the cause, it may cause trouble, electric shock or fire.
After carefully reading this manual, please keep in hand for reference. If the air conditioner is given to a new user, this manual should be attached with unit to the new user.
Grounding wire should never be connected to gas pipe, city water pipe, lightning conductor rod or the telephone line. If the grounding wire is not set properly, it may cause electric shock.
ON
OFF
A creepage breaker must be installed at the installation place
Drain pipe should be arranged properly to provide a smooth drainage.
Unless the circuit breaker is installed, it may cause electric shock.
If the pipe is arranged improperly, furniture or the like may be damaged by the leaked water.
Make sure the system is grounded.
Notice
Do not handle switches with a wet hand.
It may cause electric shock.
Do not use water to clean the air conditioner.
It may cause electric shock.
Do not do like this Do follow the instruction Do equip with grounding wire
4
Safety Precautions
Notice
The system should never be used for any other purposes than intended such as for preservation of food, flora and fauna, precision devices or work of art.
Do not put the fire devices in the places, which the air from the air conditioner can directly blow.
It may cause deterioration of the articles.
It may cause the fire devices cannot burn completely.
Do not install the system where the air outlet may directly reach the flora and fauna.
Only use the proper specified fuse.
It will not be good for their health.
If use metal wire or copper wire to replace the fuse, it may cause trouble and fire accident.
Do not put or use any spray near the air conditioner, and do not directly spray to the air conditioner.
Otherwise it may cause fire.
Safety precautions when moving, reinstalling and repairing the air conditioner
Warning
ON
OFF
Do not use the pow­er switch to turn of or off the air condit­ioner.
Do not use such equipment as a water heater, etc., around the indoor unit or the wire controller.
It may cause fire or Creepage.
If the system is operated at the vicinity of such equipment that generates steam, condensed water may drip during cooling operation or it may cause Creepage or short-circuit.
When operating the system sim­ultaneously with a combustion apparatus, indoor air must be v­entilated frequently.
*
Insufficient ventilation may ca­use the danger of lack of oxygen.
When cleaning, please stop the unit and cut o­ff the power first.
Do not put the water containers, such as vase, on the unit.
Do not perform cleaning, when the indoor fan motor is rotating in high speed.
If the water enters into the unit and damages the electric insulation material, it may cause electric shock.
Do not refit the air conditioner. When repair is needed, please contact your dealer.
When moving the air conditioner to another installation place, please contact the dealer or the professional installer.
Improper repair may cause water leakage, electric shock and fire accident.
Improper moving and reinstallation may cause water leakage, electric shock and fire accident.
5
LOW FAN MED FAN HIGH FAN
Operation instruction
MODE FAN SWING
TEMP
CLOCK
TIMER
SET
SLEEP
FILTER RESET
RESET
ON/OFF
HEAT
Fan operation
About FAN operation:
FAN operation refers the air conditioner does not perform COOLING and HEATING operation, but FAN operation. In this mode, the air conditioner cannot perform AUOT FAN operation, and does show the temperature value on the wire controller.
Turn on the unit
Press the ON/OFF button to turn on the unit The LCD display of the wire controller
will show the previous working state (except for Timer, Sleep, Swing mode), the operation indicator light on the wire controller will light up.
2
1
Choose of working mode
Press MODE button, each press the working mode will change as the following sequence:
choose FAN operation
Adjusting FAN SPEED
Press the FAN SPEED button to change fan speed:
3
4
Turn off the unit
Press the ON/OFF button to turn off the unit.
The wire controller only shows the clock and room temperature.
Choose the desired fan speed
COOLING
DEHU
AUTO
HEATING
FAN
6
AUTO COOLING DEHUMIDIFYING HEATING FAN
AUTO
LOW FAN MED FAN HIGH FAN AUTO
MODE FAN SWING
TEMP
CLOCK
TIMER
SET
SLEEP
HEAT FILTER RESET
SET
RESET
ON/OFF
Hints:
The wire controller can memorize the working condition of each time. When start the unit for the second time, just need to press ON/OFF button, the air conditioner will work according to the previous working mode. (except for Timer, Sleep and Swing)
Operation instruction
Auto/Cooling/Dehumidifying/Heating operation
Turn on the unit
Press the ON/OFF button to turn on the unit The LCD display of the wire controller will show the previous working state (except for TIMER, SWING, SLEEP mode). The operation indicator light on the wire controller will light up.
3
1
Choose of working mode
Press MODE button, each press the working mode will change as the following sequence:
then choose AUTO, COOLING, DEHUMIDIFYING, HEATING operation.
Set temperature
*Each press , the set temperature will increase 1 degree. *Each press, the set temperature will decrease 1 degree.
Set the desired temperature.
Press the TEMP. SET button
Adjusting FAN SPEED
Press the FAN SPEED button, for each press, the fan speed will change as the following sequence:
Choose the desired fan speed.
In Heating operation, after start the unit, the air conditioner will sending warm air a moment later to prevent the cold air blowing out. In Dehumidifying, when the room temperature drops 2* higher than the set temperature, regardless the set fan speed, the air conditioner will intermittently operate in low fan speed.
4
5
Turn off the unit
Press the ON/OFF button to turn off the unit.
The wire controller only shows the clock and room temperature.
2
Set temperature + 2* Set temperature
When room temperature reaches set temperature + 2*, the unit will operate in mild dehumidifying operation.
Ultra-low air flow
When room temperature is higher than set temperature, unit in COOLING operation.
7
l
Note:
l
l
l
l
MODE FAN SWING
TEMP
CLOCK
TIMER
SET
SLEEP
HEAT
FILTER RESET
SET
RESET
ON/OFF
Operation instruction
Sleep operation
Use of SLEEP function
After turning on the unit, setting the working mode, then press SLEEP button to make the air conditioner have the previous Sleep time (powered on for the first time or after performing Sleep is 1h). The Sleep symbol will appear. Press time */* button, you can choose between 1~8h. Each press, it may increase/decrease 1h and will display in the humidity area with ì xhî , and display ì Timer Offî in Timer Off area and the time to turn off; press Sleep button again to cancel Sleep function. The Sleep symbol disappears.
Before going to bed, you can press the SLEEP button, the air conditioner will operate in comfort sleep mode to make you have a sound sleep.
Before using this function, you
should calibrate the clock first, otherwise, the SLEEP function will be out of order.
2.In HEATING operation
1 hour later in SLEEP operation, the temperature will decrease 2* from the set temperature, another 1 hour later increase another 2*, then the unit will operate continuous at this temperature for 3 hours, then it increases 1*, after operating at this temperature for another 3 hours, the unit will turn off automatically. The temperature is lower than set temperature to prevent you from feeling uncomfortable during sleep.
3.In AUTO operation
The air conditioner will perform the relative SLEEP operation according to automatically chosen operation mode.
4.In FAN operation
Cannot use SLEEP function
Operation modes
1.In COOLING, DEHUMIDIFYING operation
1 hour later in SLEEP operation, the temperature will increase 1* from the set temperature, another 1 hour later increase another 1*, then the unit will operate continuous for 6 hours, then it turns off automatically. The temperature is higher than set temperature to prevent you from getting a cold.
After setting Sleep function, it is not permitted to adjust clock. The Sleep time is less than 8h, after reaching the set time, the unit will automatically stop. Set Sleep function after setting ì Timer Offî function, the air conditioner will perform Sleep function. After setting Sleep function, the Timer function cannot be set. Set Sleep function after setting ì Timer Onî function, the Sleep function can only be set in the set time of Timer On.
in COOLING* DEHUMIDIFYING operation
Set temperature
SLEEP operation starts
SLEEP operation stops
turn off
1 hour
about 6 hours
increase 1*
1 hour
increase 1*
Set temperature
SLEEP operation starts
SLEEP operation stops
turn off
1 hour
about 3 hours
3 hours
decrease 2*
increase 1*
in HEATING operation
1 hour
decrease 2*
8
Timer On/Off function
Operation instruction
OFFON OFFON
AM
PM
AM
PM
TIMER ON TIMER OFF TIMER ON-OFF
Blank
MODE FAN SWING
TEMP
CLOCK
TIMER
SET
SLEEP
HEAT FILTER RESET
ROOM
RESET
ON/OFF
Before using TIMER function, calibrate the clock first (referring to page 4). When you wake up in the morning, before going back to home after work or after going to bed, you can let your air conditioner automatically turn on or turn off.
2.Set of TIMER mode
Press the TIMER button to change the TIMER mode, each press the TIMER mode will change as the following sequence:
1.Turn on the unit
Cancel TIMER
Press the TIMER button several times until the TIMER mode display disappears.
After turning on the unit, set the desired working mode. The LCD of the wire controller will show working mode. (except for Timer, Sleep, Swing)
* Each press, the set time increases 10 minutes. If depress the button, the
time will increase rapidly.
*Each press, the set time decreases 10 minutes. If depress the button, the time will
decrease rapidly.
3.Set time
Press the time adjusting button
This LCD will show the time set, the time can be adjusted within 24h. (AM stands for morning, PM stands for afternoon).
4.Confirm the time After calibration of the clock, press SET button to confirm time.
The time displayed is: at x oíclock x minutes the unit will be turned on (TIMER ON) or turned off (TIMER OFF).
Hints:. After power failure, the clock should be calibrated again. The wire controller has memory function, when you use this function for the second time, if the time set is the same as the previous one, you just need to choose the TIMER mode then press the SET button to confirm.
At this time, the* *or* *will not flash.
ON
OFF
Then choose the timer mode as you need (TIMER ON or TIMER OFF.) At this time the or will flash.
ON
OFF
" " " "
9