Haier AP42NACABA, AP42NACBEA, AP42NACBAA, AU42NACBEA, AU42NAHBAA Operation Manual

...
Packaged unit
Operation Manual
AP42NACAAA AU42NAIAAA (HPU-44H03) AP42NACMAA AU42NAIMCA (HPU-42C03)
Ion
TIMER ON
TIMER OFF
:
AM PM
AM PM
AM PM
:
TIMER
CLOCK
SET
TIME
TIME
SLEEP
A U T O
LO
MED
HI
SET TEMP
C
ROOM TEMP
TEMP
TEMP
SWING
MODE
FAN SPEED
ON
OFF
:
AM
TEMP
SWING
FAN
ON
OFF
MODE SLEEP
SET
CLOCK
TIMER
RESETLOCK
Operation
Content
Cautions Parts Indoor unit Outdoor unit Operation display Wireless remote control
Operation Auto Cooling operation Dry operation Heating operation Fan operation Sleep Timer ON and Timer OFF Air flow adjustment Operation hints Energy saving Cautions for the operation
Maintenance Air filter and unit cleaning Before/after season maintenance Trouble shooting When problems occur Indoor & outdoor unit connection Tools necessary Installation procedures Electric wiring Others
3 3 4 4
5 6
7 8
9 10
11 12 13 14 15
16 17 18 19 20 21 22 27 28
1-2
CAUTIONS
1
Disposal of the old air conditioner
Before disposing an old air conditioner that goes out of use, please make sure it's inoperative and safe. Unplug the air conditioner in order to avoid the risk of child entrapment.
It must be noticed that air conditioner system contains refrigerants, which require specialized waste disposal. The valuable materials contained in a air conditioner can be recycled. Contact your local waste disposal center for proper disposal of an old air conditioner and contact your local authority or your dealer if you have any question. Please ensure that the pipework of your air conditioner does not get damaged prior to being picked up by the relevant waste disposal center, and contribute to environmental awareness by insisting on an appropriate, anti­pollution method of disposal.
Disposal of the packaging of your new air conditioner
All the packaging materials employed in the package of your new air conditioner may be disposed without any danger to the environment.
The cardboard box may be broken or cut into smaller pieces and given to a waste paper disposal service. The wrapping bag made of polyethylene and the polyethylene foam pads contain no fluorochloric hydrocarbon.
All these valuable materials may be taken to a waste collecting center and used again after adequate recycling.
Consult your local authorities for the name and address of the waste materials collecting centers and waste paper disposal services nearest to your house.
Safety Instructions and Warnings
Before starting the air conditioner, read the information given in the User's Guide carefully . The User's Guide contains very important observations relating to the assembly , operation and maintenance of the air conditioner.
The manufacturer does not accept responsibility for any damages that may arise due to non-observation of the following instruction.
Damaged air conditioners are not to be put into operation. In case of doubt, consult your supplier.
Use of the air conditioner is to be carried out in strict compliance with the relative instructions set forth in the User's Guide.
Installation shall be done by professional
people, don't install unit by yourself.
CAUTIONS
2
For the purpose of safety, the air conditioner must be properly grounded in accordance with specifications.
Always remember to unplug the air conditioner before opening inlet grill. Never unplug your air conditioner by pulling on the power cord. Always grip plug firmly and pull straight out from the outlet.
All electrical repairs must be carried out by qualified electricians. Inadequate repairs may result in a major source of danger for the user of the air conditoiner.
Do not damage any parts of the air conditioner that carry refrigerant by piercing or perforating the air conditioner's tubes with sharp or pointed items, crushing or twisting any tubes, or scraping the coatings off the surfaces. If the refrigerant spurts out and gets into eyes, it may result in serious eye injuries.
Do not obstruct or cover the ventilation grille of the air conditioner. Do not put fingers or any other things into the inlet/outlet and swing louver.
Do not allow children to play with the
air conditioner. In no case should
Specifications
The refrigerating circuit is leak-proof.
Parts
3
1
2
3
4
1
Outlet grill
2
Operation panel
3
Inlet grill
4
Air filter
5
Remote-controller
Indoor unit
AM
TEMP
SWING
FAN
ON OFF
MODE SLEEP
SET
CLOCK TIMER
RESET
5
LOCK
6
7
Outdoor unit
Air inlet
6
7
[At side and rear]
Air outlet
Parts
Manual Operation
Ion
TIMER ON
TIMER OFF
:
AM PM
AM PM
AM PM
:
TIMER CLOCK
SET
TIME TIME
SLEEP
A U T O
LOW
MID
HIGH
SET TEMP
C
ROOM TEMP
TEMP TEMP
SWING
MODE
FAN SPEED
ON OFF
7
6
5
3
2
9
8
10
14
:
4
Remote controlled operation
Power ON/OFF
Used for unit start and stop.
SWING
Used to set auto fan direction
MODE Used to select AUTO run, COOL, DRY, HEAT and FAN operation.
CLOCK Used to set correct time.
TIMER
TEMP
Used to select your desired temp.
FAN
Used to select fan speed: LO, MED, HI, AUTO.
SLEEP
Used to select sleep mode
SET
Used to confirm Timer and Clock setting.
HOUR
Used to set clock and timer setting.
RESET
Used to reset the controller back to normal condition.
1
8
3
4
5
6
7
2
10
9
AUTO
ON
OFF
AM PM
AM PM
AM PM
TEMP
SWING
FAN
ON
OFF
MODE SLEEP
SET
CLOCK TIMER
RESET
DRY
COOL
AUTO
SWING
FAN SPEED
LO
MED
AUTO
SLEEP
TIMER ON
TIMER OFF
CLOCK
TEMP
SIGNAL SENDING
FAN OPERATION
HEAT
AUTO
ON
OFF
AM PM
AM PM
AM PM
TEMP
SWING
FAN
ON
OFF
MODE SLEEP
SET
CLOCK TIMER
RESET
HI
AUTO
LOCK
LOCK
11
LOCK
Used to select TIMER ON, TIMER OFF , TIMER
Used to lock buttons and LCD display.
Note: Auxiliary heat function is not available. For cooling only type, heating function is not available.
Operation
5
Clock set
When unit is started for the first time and after replacing batteries in remote controller, clock should be adjusted as follows: Press CLOCK button, "AM"or "PM" flashes. Press or to set correct time. Each press will increase or decrease 1min . If the button is kept depressed, time will change quickly. After time setting is confirmed, press SET, "AM" and "PM" stop flashing, while clock starts working.
Remote contronller's operation
When in use, put the signal transmission head directly to the receiver hole on the indoor unit The distance between the signal transmission head and the receiver hole should be within 7m without any obsacles as well. Don't throw the controller, prevent it from being damaged. When electronic-started type fluorescent lamp or change-over type fluorescent lamp or wireless telephone is installed in the room, the receiver is apt to be disturbed in receiving the signal so the distance to the indoor unit should be shorter.
Loading of the battery
Slinghtly press " " and push down the cover. Load the batteries as illustrated. 2 R-03 dry batteries, (cylinder) Be sure that the loading is in line with the "+"/"-" pole request as illustrated.
Put on the cover again Confirmation indicator:
In disorderation, reload the batteries or load the new batteries after 5 mins.
reset key
AM
TEMP
SWING
FAN
ON
OFF
MODE SLEEP
SET
CLOCK TIMER
RESETLOCK
AM
TIMER CLOCK
SET
TIME TIME
SLEEP
TEMP TEMP
SWING
MODE
FAN SPEED
ON OFF
:
1
3
2
THE MACHINE IS ADAPTIVE IN FOLLOWING SITUATION
Applicable ambient temperature range:
Cooling
Heating
Indoor
Outdoor
Indoor
Outdoor
Maximum: D.B/W.B Minimum: D.B/W.B
Maximum: D.B/W.B Minimum: D.B
Maximum: D.B Minimum: D.B
Maximum: D.B/W.B Minimum: D.B/W.B
32 C/23 C 18 C/14 C
18 C
43 C/26 C
27 C 15 C
24 C/18 C
-7 C/-8 C
Note:The waster batteries should be disposed properly,use two new same-type batteries when loading. If the remote controller canít function normally or doesnít work at all,use a sharp-pointed item to pres
the reset key. Hint:Remove the batteries in case unit wonít be in usaged for a long period.
If there are any displays after taking-out just need to press reset key.
AM
TIMER CLOCK
SET
TIME TIME
SLEEP
A U T O
LOW
MID
HIGH
SET TEMP
C
TEMP TEMP
SWING
MODE
FAN SPEED
ON OFF
:
Operation
6
Auto
Manual Operation
Remote-controlled Operation
1
3
Note: During Auto run operation, temp. setting will not be shown in LCD display, unit will select heating, cooling or fan operation according to the room temp.
2
AUTO
AM
TEMP
SWING
FAN
ON
OFF
MODE SLEEP
SET
CLOCK TIMER
RESET
3
1
2
LOCK
AUTO COOL DRY HEAT FAN
2
1
Press ON/OFF button Unit starts running. The previous status appears on the display (except. TIMER, SLEEP and SWING mode)
Press MODE button. For each press, operation mode changes as follows:
Press ON/OFF button Unit stops running.
Select Auto run, " " appears and auto run starts.
3
AUTO COOL DRY HEAT FAN
Manual
Remote controlled
Operation
7
Cooling
Manual Operation
AM
TIMER CLOCK
SET
TIME TIME
SLEEP
SET TEMP
TEMP TEMP
SWING
MODE
FAN SPEED
ON OFF
:
2
3
1
5
4
C
Remote-controlled Operation
Press ON/OFF button Unit starts running. The previous status appears on the display (except. TIMER, SLEEP and SWING mode)
Press MODE button. For each press, operation mode changes as follows:
Select temp. button Press TEMP button Every time the button is pressed, temp. setting increases 1 C Every time the button is pressed, temp. setting decreases 1 C If the button is kept pressed, setting will increase or decrease quickly.
Press ON/OFF button Unit stops running,and when ectering this mode for the next time,it will show the previous setting.
Unit runs at the speed displayed on LCD.
5
3
2
1
AM
TEMP
SWING
FAN
ON
OFF
MODE SLEEP
SET
CLOCK
TIMER
RESET
3
4
5
1
2
LOCK
Select cooling operation, Shows" "
Cooling operation starts.
Press FAN button. For each press, fan speed changes as follows:
4
AUTO
LOW
MID HIGH
LOW LOW
MID MID
LOW
HIGH
HIGH
MID
LOW
AUTO
Manual
Remote controlled
AUTO COOL DRY HEAT FAN
AUTO COOL DRY HEAT FAN
Manual
Remote controller
LOW MID HIGH
Operation
8
Dry
Manual Operation
Remote-controlled Operation
Press ON/OFF button Unit starts running. The previous status appears on the display (except. TIMER, SLEEP and SWING mode)
Press MODE button. For each press, operation mode changes as follows:
Select Drying operation shows" " Dry operation starts
Select temp. button Press TEMP button Every time the button is pressed, temp. setting increases 1 C Every time the button is pressed, temp. setting decreases 1 C If the button is kept pressed, setting will increase or decrease quickly.
Press FAN button. For each press, fan speed changes as follows:
Press ON/OFF button Unit stops running, and when entering this mode for the next time, it will show the previous setting
Unit runs at the speed displayed on LCD. In DRY mode, when room temp.becomes 2 C higher than temp. setting, unit will run intermittently at LOW speed regardless of FAN setting.
3
2
1
AM
TIMER
CLOCK
SET
TIME TIME
SLEEP
SET TEMP
TEMP TEMP
SWING
MODE
FAN SPEED
ON OFF
:
4
5
COOL operation starts when room
Ultra-low air flow
Temp.setting+2 C
Temp.setting
3
2
5
1
4
AM
TEMP
SWING
FAN
ON
OFF
MODE SLEEP
SET
CLOCK TIMER
RESET
3
4
5
1
2
AUTO
LOCK
LOW
C
AUTO COOL DRY
AUTO COOL DRY
Manual
Remote controller
HEAT
HEAT
FAN
FAN
AUTO
LOW
MID
HIGH
LOW LOW
MID MID
LOW
HIGH
HIGH
MID
LOW
AUTO
Manual
Remote controlled
A U T O
On reaching 2 C higher than temp. setting,unitwill run in mild DRY mode.
Operation
9
Heating
Manual Operation
Remote-controlled Operation
Press ON/OFF button Unit starts running. The previous status appears on the display (except. TIMER, SLEEP and SWING mode)
Press MODE button. For each press,operation mode changes as follows:
Select Heating operation " " appears and Heating operation starts.
Press FAN button. For each press, fan speed changes as follow
s:
4
1
2
3
Select temp. button Press TEMP button
Note: For cooling only type, this function is invalid.
Every time the button is pressed, temp. setting increases 1 C Every time the button is pressed, temp. setting decreases 1 C
If the button is kept pressed, setting will increase or decrease quickly.
Press ON/OFF button
5
Unit stops setting when entering this mode next time.
AM
TIMER CLOCK
SET
TIME TIME
SLEEP
LOW
SET TEMP
C
TEMP TEMP
SWING
MODE
FAN SPEED
ON OFF
:
2
5
1
4
3
AM
TEMP
SWING
FAN
ON
OFF
MODE SLEEP
SET
CLOCK TIMER
RESET
4
5
1
2
3
LOCK
AUTO COOL DRY
AUTO COOL DRY
Manual
Remote controller
HEAT
HEAT
FAN
FAN
AUTO
LOW
MID
HIGH
LOW LOW
MID MID
LOW
HIGH
HIGH
MID
LOW
AUTO
Manual
Remote controlled
A U T O
In the mode,warm air will blow out after a short period of time due to cold-draft prevention function.
Operation
10
Fan
Manual Operation
Remote-controlled Operation
Press ON/OFF button Unit starts running. The previous status appears on the display (except. TIMER, SLEEP and SWING mode)
Press MODE button. For each press,operation mode change
s
as follows:
Select Fan operation shows " ", Fan operation starts.
Press ON/OFF button Unit stops running, and when entering this mode for the next time, it will show the previous setting.
4
AM
TIMER CLOCK
SET
TIME TIME
SLEEP
LO
SET TEMP
TEMP TEMP
SWING
MODE
FAN SPEED
ON OFF
:
2
4
1
3
1
2
3
Press FAN button. For each press, fan speed changes as follows:
Note: In this mode, temp. can't be selected, temp.setting will not be show in LCD display.In Fan operation mode, "AUT O" fan speed is not available. Operation cycles are as follows:
LOW MID HIGH
AM
TEMP
SWING
FAN
ON
OFF
MODE SLEEP
SET
CLOCK TIMER
RESET
3
1
4
2
LOCK
AUTO COOL DRY
AUTO COOL DRY
Manual
Remote controller
HEAT
HEAT
FAN
FAN
LOW LOW
MID MID
LOW
HIGH
HIGH
Manual
Remote controlled
LOW
MID
C
Operation
11
SLEEP
AM
TIMER
CLOCK
SET
TIME TIME
SLEEP
LOW
MID
HIGH
SET TEMP
C
TEMP TEMP
SWING
MODE
FAN SPEED
ON OFF
:
Remote-controlled operation
Before sleeping you can press the Sleep button. The conditioner will run under comfort sleep mode, and give you a comfort sleep.
Usage of the Sleep function
After starting, set the Run mode and press the Sleep button.
Run mode
1. In cooling and dry
After starting of the Sleep operation, the temperature Will be raised for 1 C higher than the set temperature 1 hour later, and be raised for 1 C after another hour. It continues under that condition for 6 hours, then the machine will be switched off. The temperature is higher than the set temperature so as to avoid catching cold in sleeping.
2. In heating ( the single-cooling conditioners do not have the function)
After the Sleep running starts, the temperature will drop for 2 C after another one hour. The temperature will raise for 1 C after 3 hours running under the above temperature, and the conditioner will be closed down after running for 3 hours. The temperature is lower than the set temperature so as to avoid uneasiness in sleeping.
3. In automatic running
The conditioner will run under automatically selected working mode of sleeping.
4. In Fan running
The Sleep function is invalid.
About 6 hours
The Sleep running starts The Sleep running stops
Set the temperature
Closc down the machine
In cooling and dry
Raise 1 C
Drop for 2 C
Drop for 2 C
About 3 hours
The Sleep running starts
The Sleep running stops
Set the temperature
Close down the machine
In heating
1 hour
Rises 1 C
1 hour
Rises 1 C
1 hour
1 hour
3 hours
AM
TEMP
SWING
FAN
ON
OFF
MODE SLEEP
SET
CLOCK
TIMER
RESETLOCK
Operation
12
Timer on/off operation
Manual Operation
Remote controlled operation
TIMER operation
TIMER ON
AM
AM
:
TIMER CLOCK
SET
TIME TIME
SLEEP
LOW
MID
HIGH
ROOM TEMP
TEMP TEMP
SWING
MODE
FAN SPEED
ON OFF
:
Set Clock correctly before starting Timer operation (refer to page 5) You can let unit start or stop automatically at following times: Before you wake up in the moring, or get back from outside or after you fall asleep at night.
TIMER ON/OFF
(1) After unit start, select your desired operation mode.
Operation mode will be displayed on LCD.
(2) TIMER mode selection
Press TIMER button to change TIMER mode. Every time the button is pressed, display changes as follows:
Manual
Remote control
TIMER ON TIMER OFF TIMER ON-OFF
Select your desires TIMER mide (TIMER ON or TIMEROFF) ON or OFF will flash.
(3) Timer setting
Press HOUR / button. Every time the button is pressed, time increases 10 min, If button is kept pressed, time will change quickly. Every time the button is pressed, time decreases 10 min, If button is kept pressed, time will change quickly. Time will be shown on LCD. It can be adjusted within 24 hours.
(4) Confirming your setting
After setting correct time, press SET button to confirm, " " or " " stops flashing. Time displayed: Unit starts or stops at x hour x min (TIMER ON or TIMER OFF) Timer mode indicator on indoor unit lights up.
To cancel TIMER mode
Just press TIMER button several times until TIMER mode disappears.
Hints
After replacing batteries or a power failure happens, Time setting should be reset. Remote controller possesses memory function when use TIMER mode next time, just Press SET button after mode selecting if timer setting is the same as previous one.
TIMER ON
TIMER OFF
TIMER ON TIMER OFF
ON ONOFF OFF
TIMER ON TIMER OFF TIMER ON-OFF
AM
12:00
AM
12:00
AM
12:00
AM
12:00
AM
12:00
PM
12:00
PM
12:00
AM
12:00
BLANK
BLANK
ON
1
3
2
4
ON
AM
AM
TEMP
SWING
FAN
ON
OFF
MODE SLEEP
SET
CLOCK
TIMER
RESET
3
4
1
LOCK
2
C
OFF
Operation
13
Timer on-off function
Manual Operation
Remote controlled operation
TIMER ON-OFF
(1) After unit start, select your desired operation mode.
Operation mode will be displayed on LCD.
(2) TIMER mode selection
Press TIMER button to change TIMER mode. Every time the button is pressed, display changes as follows:
(3) Timer setting for TIMER ON
Press HOUR button. Every time the button is pressed, time increases 10 min. If button is kept pressed, time will change quickly. Every time the button is pressed, time decreases 10 min. If button is kept pressed, time will change quickly. Time will be shown on LCD. It can be adjusted within 24 hours. AM refers to morning and PM to afternoon.
(4) Time confirming for TIMER ON
After time setting, press TIMER button to confirm, " " stops blinking, while " " starts blinking. Time displayed: Unit starts or stops at x hour x min
To cancel TIMER mode
Just press TIMER button several times until TIMER mode disappears.
ON
Manual
Remote control
TIMER ON TIMER OFF TIMER ON-OFF
TIMER ON
TIMER OFF
TIMER ON
TIMER OFF
ON ONOFF OFF
TIMER ON TIMER OFF TIMER ON-OFF
AM
12:00
AM
12:00
AM
12:00
AM
12:00
AM
12:00
PM
12:00
PM
12:00
AM
12:00
BLANK
BLANK
AM
:
TIMER
CLOCK
SET
TIME TIME
SLEEP
LO
MED
HI
ROOM TEMP
TEMP TEMP
SWING
MODE
FAN SPEED
ON OFF
:
1
3
4
6
OFF
(5) Time setting for TIMER OFF
Follow the same procedure in "Time setting for TIMER ON".
(6) Time confirming for TIMER OFF
After time setting, press SET button to confirm, " " stops flashing. Time displayed: Unit stops at x hour x min
OFF
2
TIMER ON
AM
TIMER OFF
AM
AM
TEMP
SWING
FAN
ON
OFF
MODE SLEEP
SET
CLOCK
TIMER
RESET
5
6
1
ON
AM
OFF
PM
4
LOCK
2
3
5
C
According to the Time setting sequence of TIMER ON or TIMER OFF, either ON-OFF or OFF-ON can be achieved.
Operation
14
Air flow adjustment
Swing louvers
(Vertical louvers)
Horizontal louvers
(Adjust by hand)
Up and down
Adjust the louvers by hand to proper position.
Put louvers at up position in cooling and down position in heating mode. This will be helpful to keep an even room temp.
Note:
In cooling or dry operation, don't put horizontal louvers at downward position for a long time, or outlet grill might get frosted. Don't expose your skin to cool or warm air for a long time.
Notice:
Side from side
Swing
Press SWING " " or " " appears on the display, the vertical louvers move from side to side.
Fixed position
Press the SWING again to fix the vertical louvers at your desired position.
AM
TIMER CLOCK
SET
TIME TIME
SLEEP
A U T O
LOW
MID
HIGH
ROOM TEMP
TEMP TEMP
SWING
MODE
FAN SPEED
ON OFF
:
AM
TEMP
SWING
FAN
ON
OFF
MODE SLEEP
SET
CLOCK
TIMER
RESET
AUTO
LOCK
C
Operation hints
15
Unit operation
Protection devices inside the unit will activate to stop unit operation, when ambient temp. is extremely low or high. When unit is running under high humidity in cooling or dehumidifying mode, conden­sate might appear at outlet grill.
3-min delay protection
Fan speed changes
Cold draft prevention
Use objectively
Defrosting
Unit will not restart until 3 min have elapsed for the protection of the unit.
When Fan speed is set at Auto in cooling mode, it will be automatically reduced as room temp. is approaching temp. setting. In heating mode. when room temp. reaches temp. setting, compressor will stop and fan speed LOW or stop. In dry mode, fan speed will change automatically.
In heating mode, indoor fan will not run for the first 2-5 min. due to cold draft prevention.
When frost accumulates on heat exchanger in heating mode, unit will start defrosting automatically. During defrosting, both indoor and outdoor fan stop. After defrosting, unit resumes running.
Heat pump works by means of absorbing outside heat to warm room air, so outdoor temp. degree will affect unit's heating efficiency.
Energy saving
16
Keep proper room temp.
Too cold or too warm is no good to your health, and power consumption will be increased as well.
Air filter should be periodically cleaned
If air filter is clogged: It will cause poor cooling and heating efficiency, higher power consumption and even problem may occur. In cooling operation, water will flow out.
Use Timer effectively
You may use Timer mode to keep a comfortable room temp. when you wake up or come home from outside.
Avoid direct sunlight and air flow
Adjust air flow properly
Proper temp.
8:00
5:00
AM
PM
ON
OFF
Cautions for the operation
17
Use control panel to operate the unit.
Don't press buttons unless necessary.
Use fuses of the right capacity. Never use iron or copper wires instead.
Don't touch moving outlet grills.
Keep a smooth air flow to inlet and outlet of both indoor and outdoor unit.
To avoid accident, don't insert any object into air grill.
Don't spray any paint or insecticide on the unit.
Don't splash water directly on indoor unit.
This will cause damage or even fire accident.
ON/OFF
This could be very dangerous
ON
ON
OFF
OFF
OFF
Not do
Maintenance
18
Disconnect power supply
Don't touch it with wet hand
Don't wash with hot water or solvent to clean the unit
Don't use hot water over 40 C, as this may cause damage to air filter. Wipe air filter carefully.
Clean it with warm and wet cloth or with neutral detergent, then wipe it dry with clean and soft cloth. If air conditioner is very dirty, clean it with cloth soaked in neutral detergent, then wipe off the detergent with clean water. Don't use water higher than 40 C , which will cause discoloring and deformation . Don't use insecticide or other chemical detergents.
Caution:
Indoor and outdoor cleaning
Pull it out from top as shown in Fig.
Use water or vacuum cleaner to clean it. If it is extremely dirty, wash it with neutral detergent or soap water.
Wash it with clean water and install it after complete dry.
Air filter cleaning
Maintenance
19
After season maintenance
Before season maintenance
Let the unit run in Fan mode for half a day in a fine weather to dry completely the unit inside.
Turn off the unit and pull out power plug. There might be certain power consumption even if unit is stopped.
Clean air filter and indoor unit, cover outdoor unit after cleaning.
Check if there are obstacles at inlet and outlet of indoor and outdoor unit, whick will reduce unit efficiency.
Don't fail to attach air filter after making sure it is cleaned. Dust will enter into unit causing damages or faults if it is running without air filter.
To protect compressor at start, please connect external power supply to the unit 12 hrs prior to starting. Also please keep the power supply switch ON during the whole season.
Trouble shooting
20
Followings are not problems
Sound of water flowings are not problems.
Sound of cracking is heard.
Smells are generated.
During operation, white fog or steam comes out of indoor unit.
In cooling operation, unit switches to fan operation.
Unit will not restart after stop. Won't start?
No outlet air or fan speed can't be changed in dry mode.
In heating operation, water or steam are blown out of indoor unit.
In heating operation, indoor fan won't stop even if unit is stopped.
During unit start and operation or at stop, a swishing or gurgling noise may be heard. This noise is generated by refrigerant flowing in the system.
During unit operation, a cracking noise may be heard. This noise is generated by the casing expanding or shrinking because of temperatuer changes.
This is because the system circulates smells from the interior air such as the smell of cigarettes or the painting on the unit.
When unit is running at places like restaurant where dense edible oil fumeis always exist, this will happen.
To prevent frost from accumulating on indoor heat exchanger, unit will switch to fan operation for a while then resume cooling operation.
Though ON/OFF button is set to ON, unit won't resume cooling, dry or heating operation in 3 min after it is stopped, this is because of 3-min-delay protection circuit.
Unit will reduce fan speed repeatedly and automatically if room temp. is too low in dry operation.
This occurs when frost accumulated on the outdoor unit is removed. (during defrosting operation)
After unit stops, indoor fan will go on running until indoor unit cools down.
Please wait 3 minutes
When problems occur?
21
Before ask for services, please first check your unit against following.
Air conditioner won't start.
Is power supply switch turned on?
Power supply switch is not set at ON.
Are operation controlls adjusted correctly as specified?
Are horizontal louvers at up position (in heating mode)?
Is there any direct sunlight in the room?
Poor cooling or heating
Poor cooling
Is city power supply normal?
Is air filter too dirty?
Any doors or windows left open?
If there are unexpected heat sources in the room?
Are there any obstacles at inlet or outlet grill?
Too many people in the room?
Is leakage current breaker activated?
This is very dangerous, please disconnect power supply immediately and contact your dealer.
If your unit still can't work properly after above mentioned checks, or following problems occur, please stop it immediately and contact your dealer. Fuses or circuit breakers often blow out. Water comes out in cooling/dry operation. Operation is abnormal or sound is heard.
Proper temp
Power failure?
If the fuse on PC board is broken please change it with the type of 50F.3.15A/250V.
Indoor & outdoor unit connection
22
power cable length
Approx
1.5m
Approx 2m
pipe direction
Left
Rear Right
Bottom
Over 10cm
Over 10cm
Over 10cm
Over 10cm
Over 10cm
Over 60cm
Over 15cm
Over 100cm
Indoor & outdoor unit connection
22
power cable length
Approx
1.5m
Approx 2m
pipe direction
Left
Rear Right
Bottom
Over 10cm
Over 10cm
Over 10cm
Over 10cm
Over 10cm
Over 60cm
Over 15cm
Over 100cm
23
Tools necessary
Tools necessary
Remote controller
Cement nail
Drain hose
Heat-insalution pipe
L-shaped metal
Fall-prevention fitting metal
Wire clip
Drain elbow
Self-tapping scerw
Rubber pad
Hexagon wrench
Wall hole cover
Piping hole cover
Dry battery 7
#
Putty
No. QTY
Shape and description
Parts in the following list are accessories for the unit installation which can be used if necessary.
Standard accessories
1. Screw driver
2. Hacksaw
3. 70mm dia. hole core drill
4. Spanner (dia. 17, 27mm)
5. Spanner (14, 17, 27mm)
6. Pipe cutter
7. Flaring tool
8. Knife
9. Nipper
10. Gas leakage detector or soap water
11. Measuring tape
12. Reamer
13. Refrigerant oil
Following parts shall be field supplied
Mark
Parts name Adhesive tape Pipe clip
Connecting hose
Insulation material Putty Drain hose
A
B C D E
F
***
16
15
14
13
12
11
10
9
7
6
5
4
3
2
1
1
1
3
2
2
4
4
1
3
1
1
1
1
2
8
17
1
Plastic clamp
6
1
Refrigerant oil
For cooling only type.drain elbow is not available
24
Installation procedures
Display of whole unit
Installation of outdoor unit
190
340
190 580
Installation dimension of outdoor unit (mm)
Try to bring the packed unit to the installation place. When it is inevitable to unpack the unit, be careful not to damage the unit. Wrap it with nylon etc. After unpacking, be sure to put it with the front side of the unit facing up.
Note: When delivering, don't hold plastic parts like inlet and outlet grill etc.
Selection of installation place
Place strong enough to support the unit and will not cause vibration and noise. Place where discharged wind and noise doesn't cause a nuisance to the neighbors. Place where is less affected by rain or direct sunlight and is sufficiently ventilated, or to install a shield. Place with enough space for smooth air flow.
Fixing of the unit
Fix outdoor unit using M10 bolt to concrete floor horizontally. If installed on the wall or on top of a roof, bracket should be fixed securely to resist earthquake or storms. Use rubber pad during installation against unit vibration.
over 30cm
over 10cm
over 10cm
over 15cm
over 60cm
Delivery
Facing up
Installation procedures
25
Installation of indoor unit
Selection of installation place Place where it is easy to route drainage pipe and outdoor piping. Place away from heat source and with less direct sunlight. Place where cool and warm air could be delivered evenly to every corner of the room. Place near power supply socket. Leave enough space around the unit (refer to installation drawings).
Fixing of the unit
Position of the wall hole Wall hole should be decided according to installtion place and piping direction. (refer to installation drawings) Making a wall hole Drill a hole of 70mm dia. with a little slope towards outside. Install piping hole cover and seal it with putty after installation.
1.
2.
Fixing of indoor unit To prevent it from fall off, please fix the unit with fall-prevention fitting at wall and
L-shaped metal at floor.
INDOOR
OUTDOOR UNIT
wall hole
wall thinkness
( Cross section of wall hole )
70mm
Self-tapping screw
all-prevention fitting metal (accessory)
Wood screw
L-shaped metal (accessory)
Please install the whole unit horizontally, with a slop of 1 degree at front and rear, left and right.
26
Installation of fall-prevention fitting metal:
Fix the fitting metal to the wall by screws so that there is no clearance between them. With the unit set up vertically, fix the fitting metal to the unit with screws while making an adjustment at the long portion of the hole so that there is no clearance between the upper surface and the fitting metal.
Installation of L-shaped metal
Fix to the unit by screws so that there is no clearance between the fitting metal and the unit. After confirming that the unit has been set up vertically to the floor, fix it to the floor by bolt.
Piping connection
Connecting method Apply refrigerant oil at half union and flare nut. To bend a pipe, give the roundness as large as possible not to crash the pipe. When connecting pipe, hold the pipe centre to centre then screw nut on by hand, refer to Fig. Be careful not to let foreign matters, such as sands enter the pipe.
1.
Forced fastening without centering may damage the threads and cause a gas leakage.
Pipe dia Fastening torque Liquid pipe 9.52mm(3/8") Gas pipe 19.05mm(5/8")
42N.m 110N.m
Installation procedures
27
2. Piping connection of indoor unit Arrangement of piping and drainage pipe
After opening inlet grill, you will see a control box as shown in the Fig. Remove the cover before working.
Cut away, with a hammer or a saw, the lid for piping according to piping direction.
Insulation material Copper tube
Drain hose
Connecting electric cable for indoor and outdoor unit
According to the piping method, connect the piping on indoor unit with union of connecting pipe. Arrange the piping as per the wall hole and bind drain hose connecting electric cable and piping together with polyethylene tape. Insert the bound piping connecting electric cable and drain hose through wall hole to connect with outdoor unit.
Arrangement of drain hose Drain hose shall be placed in under place. There should be a slope when arrange drain hose. Avoid up and down waves in drain hose.
Indoor unit
Slope
Good
Up
Down
Bad
If humidity is high, drain pipe( especially in room and indoor unit ) must be covered with insulation material.
Installation procedures
28
3. Piping connection of outdoor unit. Connect the connecting pipe and inlet and outlet liquid pipe according to the piping method.
Installation procedures
When piping is longer than 5 m, charge additional refrigerant specified in this list.
Pipe length Refrigerant charge (g)
5m 10m 15m 20m
500 750250
4.Purging method
Discharge the air out of the indoor unit and the refrigerant pipe by vacuumizing (1) Fasten all the nuts of the indoor and outdoor pipes to make these parts out of leakage.
(2) Under the condition of the complete close of the indoor and outdoor valve center (both liquid and gas side),dismount the repair valve cap.Vacuumizing through the charge mouth of the repair valve. (3) After vacuumizing fasten the repair valve,and dismount the cap of the big and small stop valve,then loosen the stop valve center completely and fasten the big and small stop valve.
5.Extra charging amount of the refrigerant
25m
1000
30m
1250
29
Electric wiring
Note:
Electric wiring must be done by qualified person. Use copper wire only, the parameter of connecting cable is H07RN-F4 X 0.75mm
2
.
Wiring of indoor unit
Insert the cable from outside the wall hole where piping already exist. Pull it out from front. Loosen terminal screws and insert cable end fully into terminal block, then tighten it. Pull the cable gently to make sure it is tight. Replace cover after wiring.
Wiring of outdoor unit
Insert the cable from inside the wall hole where piping already exists. Pull it out from front. Loose terminal screw and insert cable end fully into terminal block, then tighten it. Pull the cable gently to make sure it is tight. Replace cover after wiring.
Note:
When connecting indoor and outdoor wire, check the number on indoor and outdoor terminal blocks. Terminals of same number and same color shall be connected by the same wire. Incorrect wiring may damage air conditioner's controller or cause operation failure.
OK NO
terminal block
table clanip
The power cable should be over 3G2.5mm2, the power cable is self-provided.
Installation procedures
1
2
3
1
2
3
R
S
T
N
power supply
Terminal block (indoor)
Terminal block (outdoor)
R
S
T
N
1
2
3
30
Others
1. Power supply
Air conditioner must use an exclusive line (over 30A) When installation air conditioner in a wet place, try to use a circuit breaker against Current leakage. For installation in other places, use circuit breaker as far as possible.
Installation inspection and test run: Please operate unit according to this Manual. Items to be checked during test run. Please made a " "in " "
Are there any gas leakage? How is insulation at piping connection carried out? Are electric wires of indoor and outdoor unit firmly inserted into terminal block? Is electric wiring of indoor and outdoor securely fixed? Is draminage securely carried out? Is earth line ( grounding ) securely connected? Is power supply voltage abided by the code? Is there any noise? Is control display normal? Is cooling operation normal? Is room temp. regulator normal?
A
Flaring tool
Pipe dia. Dimension A(mm) Liquid pipe Gas pipe
9.52mm (3/8")
19.05mm (3/4")
1.0 ~ 1.2
1.4 ~ 2.2
2. Pipe cutting and flaring Be sure to carry out deburring after pipe cutting with a pipe cutter. Insert flaring tool to make a flare.
Correct
Lean Damaged flare Crack Partial Too outside
Incorrect
Such means for disconnection must be incorporation in the fixed wiring
The breaker of the air conditioner should be all-pole switch ; and the distance between its two contacts should be no less 3 mm.