Cautions
Disposal of the old air conditioner
Before disposing an old air conditioner that goes out of use, please make sure it's inoperative and safe. Unplug the air conditioner in order to avoid the risk of
child
entrapment. It must be noticed that air conditioner
system contains refrigerants, which require specialized waste disposal. The valuable materials contained in an air conditioner
can be recycled. Contact your local waste disposal center for proper disposal of an old air conditioner and contact your local authority or your dealer if you have any question. Please ensure that the pipework of your air conditioner doesnot get
damaged prior to being picked up by the relevant waste disposal center, and contribute to environmental awareness by insisting on an appropriate, anti-pollution method of disposal.
Disposal of the packaging of your new air conditioner
All the packaging materials employed in
the
package of your new air conditioner may
be disposed without any danger to the environment.
The cardboard box may be broken or cut
into smaller pieces and given to a waste paper disposal service. The wrapping bag made of polyethylene and the polyethylene foam pads
All these valuable materials may be taken to a waste collecting center and used again after adequate recycling.
Consult your local authorities for the name and address of the waste materials collecting centers and waste paper disposal services nearest to your house.
Safety Instructions and Warnings
Before starting the air conditioner, read the information given in the User's Guide carefully. The User's Guide contains very important observations relating to the assembly, operation and maintenance of the air conditioner.
The manufacturer does not accept responsibility for any damages that may arise due to non-observation of the following instruction.
Damaged air conditioners are not to be put into operation. In case of doubt, consult your supplier.
Use of the air conditioner is to be carried out in strict compliance with the relative instructions set forth in the User's Guide.
Installation shall be done by professional
people, don't install unit by yourself.
For the purpose of the safety,t h eai r conditioner must be properly grounded in accordance with specifications.
Always remember to unplug the air conditioner before openning inlet grill. Never unplug your air conditioner by pulling on the power cord. Always grip plug firmly and pull straight out from the outlet.
All electrical repairs must be carried out by qualified electricians. Inadequate repairs may result in a major source of danger for the user of the air conditioner.
Do not damage any parts of the air conditioner that carry refrigerant by piercing or performating the air conditioner's tubes with sharp or pointed items , crushing or twisting any tubes , or scraping the coatings off the surfaces. If the refrigerant spurts out and gets into eyes , it may result in serious eye injuries.
2
Cautions
Do not obstruct or cover the ventilation grille of the air conditioner. Do not put fingers or any other things into the inlet/outlet and swing louver.
Do not allow children to play with the air conditioner. In no case should children be allowed to sit on the outdoor unit.
Specifications
The refrigerating circuit is leak-proof.
1. Applicable ambient temperature range:
2. If the power supply cord is damaged, it
must be replaced by the manufacturer
or its service agent or a similar qualified
person.
3. If the fuse on PC board is broken,please
change it with the type of T3.15A/ 250V AC.
4. The wiring method should be in line with the local wiring standard.
5. After installation, the power plug should
be easily reached.
6. The waste battery should be disposed properly.
7. The appliance is not intended for use by young children or infirm persons without supervision.
8. Young children should be supervised to ensure that they do not play with the applience.
9. A breaker should be used in the circuits,
which should be all-pole cutoff and the distance between its two contacts should be not at least 3mm .
10.Please employ the proper power plug,
which fit into the power supply cord. (2x2.5mm +1x0.75mm )
2
11.The power plug must have acquired the
local attestation.
The machine is adaptive in following situation
2
Cooling
Heating
Indoor
outdoor
Rated Maximum Minimum 27 32 18 19 23 14 35 43 10 24 26 6 20 27 15
14.5 -- -­ 7 24 -7 6 18 --
DB C WB C DB C WB C
Indoor
outdoor
DB C WB C
DB C WB C
3
Cautions
Please read the following Safety Instructions carefully prior to use. The instructions are classified into two levels, WARNING and CAUTION according to the seriousness of possible risks and damages as follows. Compliance to the instructions are strictly required for safety use.
Safety Instruction
Installation
WARNING
Please call Sales/Service Shop for the Installation. Do not attempt to install the air conditioner by yourself because improper works may cause electric shock, fire, water leakage.
CAUTION
Installation in an inadequate place may cause accidents. Do not install in the following place.
Connect the earth cable.
PROHIBITION PROHIBITION
STRICT
ENFORCEMENT
Do not install in the place where there is any possibility of inflammable gas leakage around the unit.
Do not get the unit exposed to vapor or oil steam.
Check proper installation of the drainage securely
Use fuse with specified capacity. Replacement with steel or copper wires are absolutely prohibited.
Grounding wire should not be connected to that of gas pipeline, water pipeline,lighting arrester or telephone.
FUSE
STEEL WIRE
COPPERWIRE
4
When abnormality such as burnt-small found, immediately stop the operation button and contact sales shop.
Connect power supply cord to the outlet completely.
After installed, the unit shall be tested for electric leakage.
Take care not to damage the power supply cord.
Do not use power supply cord in a bundle.
Do not use power supply cord extended or connected in halfway.
Do not insert objects into the air inlet or outlet.
Do not try to repair or reconstruct by yourself.
PROHIBITION
PROHIBITION
PROHIBITION
PROHIBITION
PROHIBITION
OFF
STRICT
ENFORCEMENT
STRICT
ENFORCEMENT
Use an exclusive power source with a circuit breaker.
CAUTION
Do not use for the purpose of storage of food, art work, precise equipment, breeding , or cultivation.
Take fresh air occasionally especially when gas appliance is running at the same time.
Do not operate the switch with wet hand.
Do not pour water onto the unit for cleaning.
Check good condition of the installation stand.
Do not installtheunit near a fireplace or other heating apparatus.
Do not place animals or plants in the direct path of the air flow.
Do not place any objects on or climb on the unit.
Do not place flower vase or water containers on the top of the unit.
PROHIBITION
PROHIBITION
PROHIBITIONPROHIBITION
PROHIBITION
PROHIBITION
PROHIBITION
PROHIBITION
STRICT
ENFORCEMENT
Cautions
WARNING
Use of Air Conditioner
Do not channel the air flow directly at people, especially at infants or the aged.
Do not start or stop the operation by disconnecting the power supply cord and so on.
PROHIBITION
5
Parts and Functions
2
3
4
1
Indoor unit
1.OUTLET
2.CONTROL PANEL
3.INLET
4.FILTER ( inside )
S
O OF
1.
2.
3.
4.
5.
6.
7.
8.
9.
1
2 3
4
3
5
6
7
8
9
6
Parts and Functions
EMERGENCY OPERATION AND TEST OPERATION
EMERGENCY OPERATION
MODE
TEMP
FAN
POWER
EMERGENCY SWITCH
MODE
TEMP
FAN
POWER
TEST SWITCH
Room
temperature
Designated
temperature
Timer mode
Air flow
speed
Operation
mode
More than 26
Less than 23
26 23
Designated
temperature
None AUTO
AUTO HEA T
COOL
o
C
None
Anion
None
None
o
C
o
C
o
C
Operation
l
Carry out this operation only when the remote
controller is defective or lost.
l
Unit start When the emergency operation switch is pressed, a sound you can hear, which means the start of this operation.
l
Follow the requirements below.
l
Unit stop ( to cancel emergency operation)
Press the emergency switch and hear a sound ,the unit stops.Control panel only display the room temperature
TEST OPERATION
l
Use this switch in the test operation when the room
temperature is less 16
o
C
, do not it in the normal
operation.
l
Unit start Continue to press the test operation switch for more than 5 seconds. After you hear the " Hua " sound twice,release your finger from the switch, the test operation startsand the air conditioner starts with the air flow speed setting "Hi".
l
Unit stop (to cancel test operation)
Push the test run switch or operate with remote controller to cancel the test run. If you use the remote controller to cancel the test run, the conditioner will then run as per the working mode displayed on the remote controller.
Each time the power supply is switched off, and then is switched on, the conditioner
will play music once automatically. It will stop playing automatically when the starting signal is received.
Push the On/Off button and Temp +/- button, the conditioner will play the reminding
sound.The On and Temp are rising tone. The Off and Temp are dropping tone.
7
8
Operation hints
9
Maintenance
Cleaning of the unit
Turn off the power switch
Do not touch with wet hand
Do not clean with hot water or solvent
Take off the air inlet grate
First switch off the power supply,take off the screw cap,loosen the screw with cross screwdriver .
Clean the filter Use water or vacuum cleaner to remove dust. If it is too dirt, clean with detergent or neutral soap water. Rinsing with fresh water, dry the filter and re-assemble.
Caution: Do not wash filter in hot water above 40 C, which will damage the filter. Do carefully wipe the filter.
Clean the indoor(outdoor) unit Clean with warm cloth or neutral detergent, then wipe away moisture with dry cloth. Do not use too hot water(above 40 C),which will cause discoloration or deformation. Do not use pesticide or other chemical detergents.
10
Maintenance
Maintenance at the end of application season
On a fine day, unit shall be started and operate in FAN mode for about half a day until the inside of the unit becomes thoroughly dry.
Turn off the unit operation switch and power on/off. Otherwise,there will be some electricity consumption even the unit is in stop status.
Clean the filter and indoor,outdoor unit,cover
the units well.
Maintenance before beginning of aplication season
Check there are no obstacles in the air inlet and outlet to avoid impairing of working efficiency.
Please do attach the air filter to ensure the electrostatic filters not soiled.Otherwise,dirt will come into and damage the unit or bring failures.
11
Trouble shooting
Before asking for service, check the following first.
Cause or check pointsPhenomenon
The system does not restart immediately.
When unit is stopped, it won't restart immediately until 3 minutes have elasped to protect the system. When the electric plug is pulled out and reinserted, the protection circuit will work for 3 minutes to protect the air conditioner.
Normal Performance inspection
Noise is heard:
During unit operation or at stop, a swishing or gurgling noise may be heard. At first 2-3 minutes after unit start, this noise is more noticeable. (This noise is generated by refrigerant flowing in the system.) During unit operation, a cracking noise may be heard. This noise is generated by the casing expanding or shrinking because of temperature changes. Should there be a big noise from air flow in unit operation, air filter may be too dirty.
Smells are generated.
This is because the system circulates smells from the interior air such as the smell of furniture, cigarettes.
Mist or steam are blown out.
During COOL or DRYoperation, indoor unit may blow out mist. This is due to the sudden cooling of indoor air.
Multiple check
Does not work at all.
Is power plug inserted? Is there a power failure? Is fuse blown out?
Is the air filter dirty? Normally it should be cleaned every 15 days. Are there any obstacles before inlet and outlet? Is temperature set correctly? Are there some doors or windows left open? Is there any direct sunlight through the window during the cooling operation?(Use curtain)
Are th
ere too much heat sources or too many
people in the room during cooling operation?
Poor cooling
12
Installation of indoor unit selection of installation place
Place where it is easy to route drainage pipe and outdoor piping. Place ,away from heat source and with less direct sunlight. Place where cool and warm air could be delivered evently to every corner of the room. Place near power supply socket.Leave enough space around the unit. Place ,robust not causing vibration,where the body can be supported sufficiently.
more than
m
ore than
more than
m
ore than
O
Installation Manua
13
Tool necessary
1. Screw driver
2. Hacksaw
3. 70mm dia.hole core drill
4. Spanner(dia. 17,27mm)
5. Spanner(14,17,27mm)
6. Pipe cutter
7. Flaring tool
8. Knife
9. Nipper
10. Gas leakage detector or soap water
11. Measuring tape
12. Reamer
13. Refrigerant oil
Following parts shall be field supplied
Mark
Part name Adhensive tape Pipe clip Connecting hose Insulation material Putty Drain hose
A B C
D E
F
Note: There isn't connecting wire with this unit.
Fixing of the unit
1. Position of the wall hole Wall hole should be decided according to installation place and piping direction.(refer to installation drawings).
2. Making a wall hole Drill a hole of 120X70mm dia. with a little slope towards outside.
Indoor side
Outdoor side
Thickness of wall
Wall hole
70mm
(Cross section of wall hole)
Installation Manual
14
3. Piping connection Connecting method
Apply refrigerant oil at half union and flare nut. To bent a pipe, give the roundness as large as possible not to crash the pipe.
When connecting pipe, hold the pipe center to center then screw nut on by hand, refer to Fig. Be careful not to let foreign matters, such as sands enter the pipe.
Piping connection of the indoor unit
1. Arrangement of piping and drainage pipe
Cut away, with a hammer or a saw, the lid for piping according to piping direction.
According to the piping method, connect the piping on indoor unit with union of connection pipe. Arrange the piping as per the wall hole and bind drain hose connecting electric cable and piping together with polyethylene tape. Insert the bound piping connecting electric cable and drain hoes through wall hole to connect with outdoor unit.
2. Arrangement drain hose Drain hose shall be placed in under place. There should be a slope when arrange drain hose. Avoid up and down waves in drain hose. If humidity is high, drain pipe(especially in room and indoor unit) must be covered with installation material.
Pipe Diameter ( )
Fastening Torque
Liquid Side 6.35mm(1/4")
Gas Side 15.88mm(5/ 8") 61.8N.m
14.2N.m
Forced fastening without careful centering may damage the threads and cause a leakage of gas.
After opening inlet grill, you will see a control box as shown in the Fig. Remove the cover before working.
Insulation material
Copper tube
Drain hose
Connecting electric cable
=for indoor and outdoor unit
Installation Manua
15
Note: When additional refrigerant is necessary, first purge air out of connecting pipe by external gas, then drive out the excessive rerigerant by purging method. Brand new unit is charged 80g more refrigerant than spec. This is only for first instaltion to purge air in the indoor unit and connecting pipe.
When piping is longer than 5m, charge additional refrigerant specified in this list.
Pipe length 5m 10m 15m
Refrigerant charge(g) 90 180
Electric wiring Note:
Electric wiring must be done by qualified person. Use copper wire only. The parameter of the connecting cable is H07RN-F2X2.0mm
2
,
4X0.75mm2.
Wiring of indoor unit
Insert the cable from outside the wall hole where piping already exist. Pull it out from front. Losen terminal screw and insert cable end fully into terminal block, then tighten it Pull the cable gently to make sure it is tight. Replace cover after wiring.
Wiring of outdoor unit
Insert the cable from inside the wall hole where piping already exist. Pull it out from front. Loose terminal screw and insert cable end fully into terminal block, then tighten it Pull the cable gently to make sure it is tight. Replace cover after wiring.
When connecting indoor and outdoor wire, check the number on indoor and outdoor terminal blocks. Terminals of same number and same color shall be connected by the same wire.
Incorrect wiring may damage air conditioner's control or cause operation failure.
Note:
1(L)
Installation Manua
OUTDOOR UNIT TERMINIAL BLOCK
INDOOR UNIT TERMINIAL BLOCK
1 2 3
WBR
Y/G
1HP,220-230V~,50Hz
POWER SUPPLY:
Y/G
1 2 3
WBR
Y/G
Y/G