Before disposing an old air conditioner
that goes out of use, please make sure it's
inoperative and safe. Unplug the air
conditioner in order to avoid the risk of
child entrapment.
It must be noticed that air conditioner
system contains refrigerants, which require
specialized waste disposal. The valuable
materials contained in a air conditioner
can be recycled. Contact your local waste
disposal center for proper disposal of an
old air conditioner and contact your local
authority or your dealer if you have any
question. Please ensure that the pipework
of your air conditioner does not get
damaged prior to being picked up by the
relevant waste disposal center, and
contribute to environmental awareness by
insisting on an appropriate, anti-pollution
method of disposal.
Disposal of the packaging of your
new air conditioner
All the packaging materials employed in
the package of your new air conditioner
may be disposed without any danger to
the environment.
The cardboard box may be broken or cut
into smaller pieces and given to a waste
paper disposal service. The wrapping bag
made of polyethylene and the polyethylene
foam pads contain no fluorochloric
hydrocarbon.
All these valuable materials may be taken
to a waste collecting center and used
again after adequate recycling.
Consult your local authorities for the name
and address of the waste materials
collecting centers and waste paper
disposal services nearest to your house.
Safety Instructions and Warnings
Before starting the air conditioner, read the
information given in the User's Guide
carefully. The User's Guide contains very
important observations relating to the
assembly, operation and maintenance of
the air conditioner.
The manufacturer does not accept
responsibility for any damage that may
arise due to non-observation of the following
instructions.
Damaged air conditioners are not to be
put into operation. In case of doubt, consult
your supplier.
Use of the air conditioner is to be carried
out in strict compliance with the relative
instructions set forth in the User's Guide.
Installation shall be done by professional
people, and don't install the unit by yourself.
For the purpose of safety, the air
conditioner must be properly grounded in
accordance with specifications.
Always remember not to operate the air
conditioner before opening its inlet grill.
All electrical repairs must be carried out by
qualified electricians. Inadequate repairs
may result in a major source of danger for
the user of the air conditioner.
Do not damage any parts of the air
conditioner that carry refrigerant by piercing
or perforating the air conditioner's tubes with
sharp or pointed items, crushing or twisting
any tubes, or scraping the coatings off the
surfaces. If the refrigerant spurts out and
gets into eyes, it may result in serious eye
injuries.
1
Cautions
Do not obstruct or cover the ventilation
grille of the air conditioner. Do not put
fingers or any other things into the
inlet/outlet and swing louver.
Do not allow children to play with the air
conditioner. In no case should children be
allowed to sit on the outdoor unit.
Specifications
The refrigerating circuit is leak-proof.
The machine is adaptive in following
situation:
1.Applicable ambient temperature range:
Rated Maximum Minimum
27 32 18
DB C
19 23 14
WB C
35 43 10
DB C
24 26 6
WB C
20 27 15
DB C
14.5 -- --
WB C
7 24 -15
DB C
6 18 --
WB C
Cooling
Heating
Indoor
outdoor
Indoor
outdoor
All the cables shall have got the local
authentication certificate.
6. The breaker of the air conditioner should
be all-pole switch; and the distance between
its two contacts should be no less than
3mm. Such means for disconnection must
be incorporation in the fixed wiring.
7. The waste battery shall be disposed
properly.
8. The appliance is not intended for use
young children or infirm persons without
super vision.
9. Young children should be supervised to
ensure that they do not play the appliance.
2. If the supply cord is damaged, it must be
replaced by the manufacturer or its service
agent or a similar qualified person.
3. If the fuse on PC board is broken, please
change it with the type of T 3.15A /250VAC.
4. The wiring method should be in line with
the local wiring standard.
5. The power cable and connecting cable
are self-provided.
The requirement of the connecting cable:
Model
AD092XLERA
AD122XLERA
AD142XLERA
AD182XLERA
Connecting cable
Power cable: H05RN-F 3G 2.5mm
Signal wires: H05RN-F 2X1.5mm
2
2
2
Safety precautions
Carefully read the following information in order to operate the air conditioner
correctly.
Below are listed three kinds of Safety Cautions and Suggestions.
WARNING!
CAUTION!
INSTRUCTIONS:
Incorrect operations may result in severe consequences of death or serious injuries.
Incorrect operations may result in injuries or machine damages; in some cases may
cause serious consequences.
These information can ensure the correct operation of the machine.
Be sure to conform with the following important Safety Cautions.
The Safety Cautions should be at hand so that they can be checked at any time when
needed.
If the conditioner is transferred to the new user, this manual should be as well transferred
to the new user.
WARNING!
Don't blow the human body with the cooling
air too long, and don't let the room
temperature decrease too low either.
Otherwise the one will feel unpleasant or harm
ones' health.
If any abnormal phenomena is found (e. g.
smell of firing), please cut off the power
supply immediately, and contact the dealer
to find out the handling method.
Please let the dealer be responsible for
installing the conditioner.
Incorrect installation may cause water leak,
electrical shock and fire hazard.
Don't put fingers or any other things into
the inlet/outlet and swing louver while the
conditioner is in operation.
Because the highspeed fan is very dangerous
and may cause injuries.
In such case, to continue
using the conditioner will
damage the conditioner,
and may cause electrical
shock or fire hazard.
When need maintenance and repairment,
call dealer to handle it.
Incorrect maintenance and repairment
may cause water
leak, electrical shock
and fire hazard.
switch
off
Call the dealer to take measures to prevent
the refrigerant from leaking.
If conditioner is installed in a small room, be
sure to take every measure in order to prevent
suffocation accident even in case of refrigerant
leakage.
When conditioner is deinstalled or reinstalled
dealer should be responsible for them.
Incorrect installation may cause water leaking,
electrical shock and fire hazard.
3
Safety precautions
CAUTIONS!
Conditioner should not be used for any
other purpose other than airconditioning.
Don't use air-conditioner for any other special
purposes, e.g. the preservation and protection
of food, animals, plants, pecision apparatus
as well as work of art, otherwise the qualities
of these stuffs may be damaged.
Don't dismantle the outlet of the outdoor
unit.
The exposure of fan is
very dangerous which
may harm human beings.
When air-conditioner is co-used with
other heat-radiator the frequent
replacement of room atmosphere should
be required.
Inefficient ventilation may cause
suffocation.
After a long time use of air-conditioner
the base should be checked for any
damages.
If the damaged base is
not repaired, the unit
may fall down and
cause accidents.
No goods or nobody is permitted to placed
on or stand on outdoor unit.
The falling of goods and
people may cause accidents.
Don't operate the air-conditioner with damp
hands.
Otherwise will be shocked.
Only use correctly-typed fuse.
May not use wire or any other materials
replacing fuse, otherwise may cause faults or
fire accidents.
Don't place any burning unit
air-conditioner,
combustion.
No inflammable spray fluid should be
permitted to be placed or used near to
airconditioner other wise may cause fire
accidents.
Air-conditioner should be cleaned only after
power supply is cut off to keep from shock
or hurt.
Don't clean air-conditioner with water.
Otherwise may cause shock.
When use the fumigating insecticide don't
open air-conditioner.
Otherwise the poisonous chemicals may settle
in air-conditioner which harm the health of
chemical-allergic people.
which may cause incomplete
in the air flow of
Pets and plants should not be blowed
directly in the air flow.
Otherwise will suffer damage.
4
Safety precautions
CAUTIONS ON INSTALLATION
Please ask the dealer or specialist to install, never try by the users themselves. After the installation
please be sure of the following conditions.
Please call dealer to install the air-conditioner.
Incorrect installation may cause water leaking, shock and fire hazard.
CAUTION !
Air-conditioner can't be installed in the
envi-ronment with inflammable gases
because the inflammable gases near to
air-conditioner may cause fire hazard.
Installed electrical-leaking circuit breaker.
It easily cause electrical shock without circuit
breaker.
[Location]
Air-conditioner should be located in well-vented
and easily-accessible place.
Air-conditioner should not be located in the
following places:
(a) Places with machine oils or other oil
vapours.
(b) Seaside with high salt content in the air.
(c) Near to hot spring with high content of
sulfide gases.
(d) Area with frequent fluctuation of voltage
e.g. factory, etc.
(e) In vehicles or ships.
(f) Kitchen with heavy oil vapour or humidity.
(g) Near to the machine emitting electricmagnetic waves.
(h) Places with acid, alkali vapuor.
Connect earthing wire.
Earthing wire should not be con nected to the gas pipe, water
pipe, lightning rod or phone line,
in-correct earthing may cause
shock.
Use discharge pipe correctly to ensure
efficient discharge.
Incorrect pipe use may cause water leaking.
As required, take measures against heavy
snow.
Earthing
[Wiring]
Air-conditioner should be equipped with special
power supply wire.
[Operating noise]
Chose the following locations:
(a) Capable of supporting air-conditioner weight,
don't increase operating noise and vibration.
(b) Hot vapour from outdoor unit outlet and
operating noise don't disturb neighbour.
TV, radio, acoustic appliances etc are at least
1 m far away to the indoor unit, outdoor unit,
power supply wire, connecting wire, pipes,
otherwise images may be disturbed or noises
be created.
No obstacles around the outdoor unit outlet.
5
Notes for safety
The instructions with this warning mark must be carried out strictly,for they
!
are all concerned with safety of the product or human beings.
The instructions with this warning mark must be carried out strictly, for they are all
concerned with safety of the product or human beings.
Clean the dust filter periodically:
Blockage of the dust filter would reduce the cooling and heating effect, consume
more power, water would be leaked during cooling, and other failures would also
occur.
Use the fuse of required capacity:
Never use steel wire or copper wire to take place of the fuse.
Operate the unit with the remote controller.
The instructions with this prohibiting mark must be completely forbidden,
otherwise the product would be damaged or the human being would be injured.
Never connect the earth wire with the gas pipe, water pipe, lightening arrester, or
phone line.
Never install the air conditioner where the flammable gas is easily leaked.
Do not spray any paint or insecticide on the air conditioner.
Never pour water on the indoor unit.
Keep the inlet and outlet of the didoor unit unblocked.
When the louver is being swung, never touch the outlet or put anything into the air
grille.
6
Parts and Functions
INDOOR UNIT
Air inlet
Electrical box
Drain pan
Air outlet