Haier AD142AMBIA, AU142AFBIA User Manual

DUCT TYPE AIR CONDITIONER
Operation & Installation Manual
AD142AMBIA AU142AFBIA
Please read this operation manual before using the air conditioner.
No. 0010572912 A
TABLE OF CONTENTS
CAUTIONS SAFETY PRECAUTIONS PARTS AND FUNCTIONS
MALFUNCTION CARE AND MAINTENANCE
INSTALLATION MANUAL FOR OUTDOOR UNIT INSTALLATION MANUAL FOR INDOOR UNIT INSTALLATION MANUAL FOR ELECTRIC WIRING 21 INSTALLATION MANUAL FOR WIRE CONTROLLER CHECK AND TEST RUN
2
3-5
7-8
9-10
11-14
15-20
22 23
6
CAUTIONS
Disposal of the old air conditioner
Before disposing an old air conditioner that goes out of use, please make sure it's inoperative and safe. Unplug the air conditioner in order to avoid the risk of child entrapment.
It must be noticed that air conditioner system contains refrigerants, which require specialized waste disposal. The valuable materials contained in a air conditioner can be recycled. Contact your local waste disposal center for proper disposal of an old air conditioner and contact your local authority or your dealer if you have any question. Please ensure that the pipework of your air conditioner does not get damaged prior to being picked up by the relevant waste disposal center, and contribute to environmental awareness by insisting on an appropriate, anti-pollution method of disposal.
Disposal of the packaging of your new air conditioner
All the packaging materials employed in the package of your new air conditioner may be disposed without any danger to the environment.
The cardboard box may be broken or cut into smaller pieces and given to a waste paper disposal service. The wrapping bag made of polyethylene and the polyethylene foam pads contain no fluorochloric
hydrocarbon. All these valuable materials may be taken to a waste collecting center and used again after adequate recycling. Consult your local authorities for the
nameand address of the waste materials collecting centers and waste paper disposal services nearest to your house.
Safety Instructions and Warnings
Before starting the air conditioner, read the information given in the User's Guide carefully. The User's Guide contains very
important observations relating to the assembly, operation and maintenance of the air conditioner.
The manufacturer does not accept responsibility for any damages that may arise due to non-observation of the following instruction.
Damaged air conditioners are not to be put into operation. In case of doubt, consult your supplier.
Use of the air conditioner is to be carried out in strict compliance with the relative instructions set forth in the User's Guide.
Installation shall be done by professional people, don't install unit by yourself.
For the purpose of safety , the air conditioner must be properly grounded in accordance with specifications.
Always remember to unplug the air conditioner before opening inlet grill. Never unplug your air conditioner by pulling on the power cord. Always grip plug firmly and pull straight out from the outlet.
All electrical ropairs must be carried out by qualified electricians. Inadequate repairs may result in a major source of danger for the user of the air conditoiner.
Do not damage any parts of the air conditioner that carry refrigerant by piercing or perforating the air conditioner's tubes with sharp or pointed items, crushing or twisting any tubes, or scraping the coatings off the surfaces. If the refrigerant spurts out and gets into eyes, it may result in serious eye injuries.
Do not obstruct or cover the ventilation grille of the air conditioner. Do not put fingers or any other things into the inlet/outlet and swing louver.
Do not allow children to play with the air conditioner. In no case should children be allowed to sit on the outdoor unit.
SAFETY PRECAUTIONS
Before starting to use the system, read carefully this"SAFETY PRECAUTIONS" to ensure a proper operation of the system. Safety precautions described here are classified to " W ARNING" and " CAUTION". Precautions which are shown in the column of
" W ANING" means that an improper handing could lead to a grave result like a death, serious injury, etc. However, even if precautions are shown in the column of " CAUTION", a very serious problem could occur depending on situation. Make sure to observe these safety precautions faithfully because they are very important information to ensure the safety.
Symbols which appear frequently in the text have following meanings.
Strictly prohibited.
Observe instructions faithfully.
Provide a positive grounding.
When you have read through the manual, keep it always at hand for read consultation. If the operator is replaced, make sure to hand over this manual to the new operator.
CAUTIONS FOR INSTALLATION
WARNING
The system should be applied to places as office, restaurant, residence and the like.
Application to inferior environment such as an engi­neering shop, could cause equipment malfunction and serious injury or death.
Do not install nearby the place where may have leakage of flammable gas.
If the gas leakes and gathers around, it may cause the fire.
Where strong winds may prevail, the system should be fixed securely to prevent a collapse.
The system should be installed by your dealer or a professional installer.
Installation by yourself is not encouraged because it could cause such problems as water leakage, electrical shock or fire accident by some improper handing.
CAUTION
Depending on the place of installation, a circuit breaker may be necessary.
ON
OFF
Unless the circuit breaker is installed, it could cause elecrical shocks.
Install on the place where can endure the weight of air conditioner.
When you need some optional devices such as a hu­midifier, electric heater, etc., be sure to use the products which are recommended by us. These devices should be attached by a professional installer.
Installation by yourself is not encouraged because it could cause such problems as water leakage, electrical shock or fire accident by some improper handing.
Drain pipe should be arranged to provide a positive draining.
If the pipe is arranged improperly, furniture or the likes may be damaged by leaked water.
Make sure the system is grounded.
Bodily injury could result by a collapse.
CAUTIONS FOR OPERATION
You should refrain from exposing your body directly to cool wind for a long time.
It could affect your physical condition or cause some health problems.
The system should never be used for any other purposes than intended such as for preservation of food, flora and fauna, pre­cision deices or work of art.
It could cause deterioration of food or other problems.
Bodily injury could result by a careless installation.
WARNING
Do not poke the air inlet or outlet with a bar, etc.
Since the internal fan is operating with a high speed, it could cause an injury.
CAUTION
Do not handle switches with a wet hand.
It could cause electric shocks.
Grounding cable should never be connected to a gas pipe, city water pipe, lightning conductor rod or grounding cable of telephone. If the grounding cable is not set properly, it could cause electric shocks.
When any abnormal condition (scorching smell or oth­ers) is found, stop the operation immediately and turn off the power switch. Then consult your dealer.
If you continue the operation without removing the cause, it could result in a trouble, electric shock or fire.
Combustion apparatus should not be placed allowing a direct exposure to wind of air con­ditioner.
Incomplete combustion could occur on the apparatus.
SAFETY PRECAUTIONS
CAUTION
Do not wash the air conditioner with water.
Do not install the system where the air outlet reaches directly the flora and fauna.
Make sure to use a fuse of proper electric rating.
It could cause electric shocks.
Neither stand on the air conditioner nor place something on it.
There are risks of falling or injury by collapsed object.
Do not use the power switch to turn on or off the system.
ON
OFF
It could cause a fire or water leakage. There is a risk of injury.
When operating the system simultaneously with a combustion apparatus, indoor air must be ventilated frequently.
It will not be good for their health.
It is strictly prohibited to place a container of combustible gas or liquid near the air condi­tioner or to spray it directly with the gas or liquid.
It could cause a fire accident.
Do not touch the air outlet section while the swing louver is operating.
Use of steel or copper wire in place of a fuse is strictly prohibited because it could result in a trouble or fire accident.
Do not operate the system while the air outlet grill is removed.
There is a risk of injury.
Do not use such equipment as a water heater, etc. around the indoor unit or the wire controller.
If the system is operated at the vicinity of such equip­ment which generates steam, condensed water may drip during cooling operation or it could cause a fault current or short-circuit.
Check occasionally the support structure of the unit for any damage after a use of long period of time.
Insufficient ventilation could cause an oxygen deficiency accident. If the structure is not repaired immediately, the unit could topple down to cause
When cleaning the system, stop the operation and turn off the power switch.
Cleaning should never be done while the internal fans are running with high speed.
a personal injury.
Do not put water containers on the unit such as a flower vase, etc.
If the structure is not repaired immediately, the unit could topple down to cause apersonal injury.
CAUTIONS FOR TRANSFER OR REPAIR
WARNING
Modification of the system is strictly prohibited. When the system needs a repair, consult your dealer.
Improper practice of repair could cause water leakage, electric shock or fire. Improper practice of installation could cause water leakage, electric shock or fire.
When the air conditioner is relocated, contact your dealer or a pro­fessional installer.
SAFETY PRECAUTIONS
The machine is adaptive in following situation
1. Applicable ambient temperature range:
Rated Maximum Minimum
Indoor
Cooling
outdoor
DB C WB C DB C WB C
Heating
Indoor
outdoor
DB C WB C DB C WB C
2. If the supply cord is damaged, it must be replaced by the manufacturer or its service agent or a similar qualified person.
3. If the fuse on PC board is broken please change it with the type of T3.15A /250VAC.
4. The wiring method should be in line with the local wiring standard.
5. Use copper wire only. The connecting cable should be H05RN-F 4G 0.75mm2. The power cable should be H07RN-F 3G 2.5mm2. All the cables shall have got the European allthentication certificate.
6. The power supply connects from the outdoor side.
7. The breaker of the air conditioner should be all-pole switch; and the distance between its two contacts should be no less 3mm.
8. The indoor unit installation height is at least 2.5m.
27 32 18 19 23 14 35 43 -5 24 26 -­ 20 27 15
14.5 -- -­ 7 24 -7 6 18 --
Note:
Part of the power supply of the air conditioner are not prepared because of the requirement of the dealer, the power supply should be provided for oneself.
PARTS AND FUNCTIONS
Indoor Unit
Fan(inside)
Motor(inside)
Evaporator
Air outlet gille
Outdoor Unit
Air inlet
Air outlet
Connecting piping and electrical wiring
Drain hose
14
MALFUNCTION
please check the following things about your air conditioner before making a servie call.
Unit fails to start
Is the power source switch adjust cut in?
ON
OFF
Power supply switch is not ON.
Is the thermostat adjust as required?
Isn't the swing louver horizontal? (At HEATING mode)
If swing louver is horizontal, the blow wind does not reach floor.
The wind does not blow during heating operation
Isn't it warming up?
page 9
There is a irregularity in operation or abnormal sound is audible. When the CHECK lamp flickers, an irregularity has occurred in the air conditioner.
Is city supply power in normal?
Power stoppage?
Isn't the signal receiving section exposed to the direct sunlight or strong illumination?
Isn't the earth leakage breaker in action?
It is dangerous. Turn off the power supply switch immediately and contact the sales dealer.
Cooling or heating is not sufficient
Isn't the air filter dirty?
Isn't any doors or windows left open?
Doesn't any obstacle exist at the air inlet or outlet?
Cooling is not sufficient
Isn't sun-shine invading direct?
When the air conditioner does not operate properly after you have checked the above mentioned items or when the following phenomenon is observed, stop the operation of the air conditioner and contact your sales dealer.
The fuse or breaker often shuts down. Water drops off during cooling operation.
Isn't any unexpected heating load generated?
Isn't the room much crowded?
Flickering
Content of defect
Flickering
Content of defect
F1
The trouble of the room temp.sensor
E4
The trouble of the comp. too hot
F2
The trouble of the pipe temp. sensor
E5
The trouble of the overload current
F4
The trouble of the overload heating
The trouble of the cooling ice over
E6 E7 E8
The trouble of the outdoor room temp. sensor
The trouble of the outdoor pipe temp. sensor
F5 F7
The trouble the wiring controller and outdoor comumication
singlechip bad
of
The trouble of the module
E0
The trouble of the water pump
E1
EA
voltage of power supply too high
E2
No load
The trouble of the overload cooling
The trouble the indoor and outdoor comumication
EC
Note:
This unit has a function of automatic restart system after recovering power stoppage. Please contact the sales dealer if it is not required.
E3
of
EE
E2PROM bad
MALFUNCTION
The followings are not malfunction
Water flowing sound is heard.
Shuru
Shuru
Cracking sound is heard.
It smells.
During operation, white fog comes out of indoor unit.
It is switched into the FAN mode during cooling.
The air conditioner can not be restarted soon after it stops.
Unit does not start
When the air conditioner is started, when the compressor starts or stops during operation or when the air conditioner is stopped, it sometimes sounds "shuru shuru" or "gobo gobo". It is the flowing sound of the refrigerant, and it is not a trouble.
This is caused by heat expansion or contraction of plastics.
Air which blows out from the indoor unit sometimes smells. The smell results from residents of tobacco smoke or cosmetics stuck inside of unit.
When the air conditioner is used at restaurant etc. where dense edible oil fume is always exists, white fog sometimes blows out of air outlet during operation. In this case consult sales dealer for cleaning the heat exchanger.
To prevent frost from being accumulated on the indoor unit heat exchanger, it is sometimes automatically switched to the FAN mode but it will soon return to the cooling mode.
Even if the operation switch is turned on, cooling, dehumidifying or heating is not operable for three minutes after the conditioner is stopped. Because the protecting circuit is activated. (During this time air conditioner operates in fan mode.)
Wait for three minutes
Air does not blow or the fan speed can not be changed during dehumidifying
During operation, operation mode has changed over automatically.
Water or steam generates from the outdoor unit during heating.
When it is excessively cooled during dehumidifying, the blower automatically repeats reducing and lowering the fan speed.
Isn't the AUTO mode selected? In the case of AUTO mode, operation mode is changed automati­cally from cooling to heating or vise-versa according to the room temperature.
This results when frost accumulated on the outdoor unit is removed (during defrosting operation).
CARE AND MAINTENANCE
Points to observe
Turn off the power supply switch. Do not touch with wet hand.
ON
OFF
CAUTION
Do not use hot water or volatileliquid.
Thinner
Do not open the inlet grill until fan stops completely. Fan will continue rotating for a while by the law of inertia after operation is being stopped.
Cleaning
1. Clean the air filter by lightly tapping it or with the cleaner. It is more effective to clean the air filter with water. If the air filter is very dirty, dissolve neutral detergent in the lukewarm water (approx. 30 C), rinse the air filter in the water, and thoroughly wash the air filter off the detergent in the plain water.
2. After drying the air filter, set it up on the air conditioner.
CAUTION
Do not dry the air filter with fire. Do not run the air conditioner without the air filter.
Do not use!
Benzine
Tooth powder
Care and Cleaning of the unit
Clean with soft and dry cloth. If it is very dirty, dissolve neutral detergent in the lukewarm water and make the cloth wet with the water. After wiping, clean off the detergent using clean water.
Post-Season Care
Operate the unit with FAN mode on a fair day for about half a day to dry the inside of the unit well. Stop operation and turn off the power supply switch. Electric power is consumed even the air conditioner is in stop. Clean the air filter and set it in the place.
Pre-Season Care
See that there are no obstacles blocking the air inlet and air outlet of both indoor and outdoor units. Make sure that the air filter is not dirty. Cut in the power supply switch 12 hours before starting run.
CARE AND MAINTENANCE
"HOT KEEP"is operated in the following cases.
When heating is started:
In order to prevent blowing out of cool wind, the indoor unit fan stopped according to the room temperature which heating operation is started. Wait for approx. 2 to 3 minute, and the operation will be automatically changed to the ordinary heating mode.
Defrosting operation (in the heating mode):
When it is liable to frost. the heating operation is stopped automatically for 5 to 12 minutes once per approx. one hour, and defrosting is operated. After defrosting is completed, operation mode is automatically changed to ordinary heating operation.
When the room thermostat is actuated:
When room temperature increases and room temperature controller actu­ates, the fan speed is automatically changed to stop under low temperature condition of indoor heat exchanger. When room temperature decreases, air conditioner automatically changes over to ordinary heating operation.
WARMING OPERATION
Heat pump type warming
With the heat pump type warming, the mechanism of heat pump that concentrate heat of outdoor air with the help of refrigerant to warm the indoor space, is utilized.
Defrosting operation
When a room is warmed with a heat pump type air conditioner, frost accumulates on the heat exchanger of outdoor unit along with the drop of indoor temperature. Since the accumulated frost reduces the effect of warming, it is necessery to automatically switch the operation to the defrosting mode. During the defrosting operation, heating operation is interrupted.
Atmospheric temperature and warming capacity
Warming capacity of heat pump type air conditioner decreases along with the drop of outdoor temperature. When the warming capacity is not sufficient, it is recommended to use another heating implement.
Period of warm-up
Since the heat pump type air conditioner employs a method to circulate warm winds to warm the entire space of a room, it takes time before the room temperature rises. It is recommendable to start the operation a little earlier in a very cold morning.
10
INSTALLATION MANUAL FOR OUTDOOR UNIT
Confirm the following items for safe and comfortable use of air conditioner.
The installation work is to be burden on the sales dealer, and do not conduct it by yourself.
Installation place
Avoid installing the air conditioner near the place where possibility of inflammable gas leakage exists.
Explosion (Ignition) may occur.
Select the place so as not to annoy neighbor with the hot air or noise.
Install the unit at well ventilated place.
If some obstacle exist, it may cause capacity reduction or noise increase.
Snow protection work is necessary where outdoor unit is blocked up by snow.
For details consult your sales dealer.
Install the air conditioner firmly on the foundation that can fully support the weight of the unit.
If not, it may cause vibration or noise.
It is advisable not to install the air con­ditioner at the following special place. It may cause malfunction, consult the sales dealer when you have to install the unit on such a place.
The place where corrosive gas generates (Hot spring area etc.) The place where salt breeze blows (Seaside etc.) The place where dense soot smoke exists The place where humidity is extraordina­rily high The place where near the machine which radiates the electromagnetic wave The place where voltage variation is con­siderably large
Electric work
The electric work must be burden on the authorized engineer with qualification for electric work and grounding work, and the work must be conducted in accordance with electric equipment technical standard.
The power source for the unit is to be of exclusive use. An earth leakage breaker should be installed.(This is necessary to prevent electric shock.) The unit must be grounded.
When you change your address or the installation place
Special technology is required for removal or reinstallation of air conditioner, consult the sales dealer. Besides, construction expense is charged for removal or reinstallation.
For inspection and maintenance
The capacity of air conditioner will decrease by contamination of inside of unit when it is used for about three years although depending upon the circumstances under which it is used, and so in addition to the usual maintenance service, special inspection/maintenance service is necessary. It is recommended to make a maintenance contract (charged) by consulting your sales dealer.
11
INSTALLATION MANUAL FOR OUTDOOR UNIT
<Heat Pump model/Cooling Only model >
WARNING
BE SURE TO READ THESE INSTRUCTIONS CAREFULLY BEFORE BEGINNING INSTALLATION. FAILURE TO FOLLOW THESE INSTRUCTIONS COULD CAUSE SERIOUS INJURY OR DEATH, EQUIPMENT MALFUNCTION AND/OR PROPERTY DAMAGE. BE SURE TO READ INSTALLATION MANUAL FOR INDOOR UNIT WITH THIS MANUAL.
1. Accessories
Edging
"Edging" for protection of electric wires from an opening edge.
2. Selection of the place of installation
Select the place of installation satisfying the following conditions and, at the same time, obtain a consent from the client or user.
Place where air circulates. Place free from heat radiation from other heat sources. Place where drain water may be discharged. Place where noise and hot air may not disturb the neighborhood. Place where there is not heavy snowfall in the winter time. Place where obstacles do not exist near the air inlet and air outlet . Place where the air outlet may not be exposed to a strong wind. Place surrounded at four sides are not suitable for installation. A 1m or more of overhead space is needed for the unit. Mount guide-louvers to place where short-circuit is a possibility. When installing several units, secure sufficient suction space to avoid short circuiting.
(1) Open space requirement around the unit
Air inlet
Air outlet
L3
500
(Servicing space)
L1
Distance
Air inlet
L2
Case
L1 L2 L3
I
open
300
150
II III
open
0
300
Unit: mm
500
open
150
(2) Installation where the area with strong winds.
Install the unit so that the air outlet section of the unit must NOT be faced toward wind direction.
3. Installation of outdoor unit
(1) Installation
Fix the unit in a proper way according to the condition of a place where it is installed by referring to the following .
(a)
Concrete foundation
Anchor bolt
Note (1) Give enough room for the concrete foundation to fix by anchor bolts.
Unit
Concrete foundation
To fix by bolts
Install the unit so that the angle of inclination must be less than 3 degrees.
Foundation anchor
Note (1) Place the concrete foundation deep enough.
Unit
Concrete foundation
Anchor bolt
12
NO
Wind direction
INSTALLATION MANUAL FOR OUTDOOR UNIT
4. Refrigerant piping
(1) Outline piping
Flare connection
Liquid pipe
3-way valve
Indoor unit
Gas pipe
Flare connection
3-way valve
(2) Piping size
Liquid pipe
Gas pipe
9.52x0.8mm
15.88x1.0mm
Install the removed flared nuts to the pipes to be connected, then flare the pipes.
(3) Limitations for one way piping length and vertical height difference.
One way piping length: less than 15m. Vertical height difference: Less than 5m.
Precautions for refrigerant piping
Do not twist or crush piping. Be sure that no dust is mixed in piping. Bend piping with as wide angle as possible. Keep insulating both gas and liquid piping. Check flare-connected area for gas leakage.
Outdoor unit
90 + 0.5
(4) Piping connection
Connecting method Apply refrigerant oil at half union and flare nut. To bend a pipe, give the roundness as large as possible not to crash the pipe. When connecting pipe, hold the pipe centre to centre then screw nut on by hand, refer to Fig. Be careful not to let foreign matters, such as sands enter the pipe.
Forced fastening without centering may damage the threads and cause a gas leakage.
Liquid pipe 9.52mm(3/8")
Pipe dia Fastening torque
Gas pipe 15.88mm(5/8")
13
42N.m 60N.m
INSTALLATION MANUAL FOR OUTDOOR UNIT
(5) Purging method ( the refrigerant is R407C)
Liquid pipe
To use vacuum pump
1
Detach the service port's cap of 3-way valve, the valve rod's cap for 3-way valve and 3-way's, connect the service port into the projection of charge hose (low) for gaugemanifold. Then connect the projection of charge hose (center) for gaugemanifold into vacuum pump.
3-way valve
6.35mm(1/4'')
Gas pipe
12.7mm(1/2'')
3-way valve
Gaugemanifold
2
Open the handle at low in gaugemanifold, operate vacuum pump. If the scale-moves of gause (low) reach vacuum condition in a moment, check 1 again.
3
Vacuumize for over 15min. And check the level gauge which should read -0.1 MPa (-76 cm Hg) at low pressure side. After the completion of vacuumizing, close the handle 'Lo' in gaugemanifold and stop the operation of the vacuum pump. Check the condition of the scale and hold it for 1-2min. If the scale-moves back in spite of tightening, make flaring work again, the return to the beginning of 3 .
4
Open the valve rod for the 3-way valve to and angle of anticlockwise 90 degree. After 6 seconds later, close the 3-way valve and male the inspection of gas leakage.
5
No gas leakage?
6
Detach the charge hose from the service port, open 3-way valve and 3-way. Turn the valve rod anticlockwise until hitting lightly.
7
To prevent the gas leakage, turn the service port's cap, the valve rod'd cap for 3-way valve and 3-way's a lottle more than the point where the torque increases suddenly.
In case of gas leakage, tighten parts of pipe connection. If leakage stops, then proceed steps.
Vacuum pump
2
Open
3
Close
3-way valve
3-way valve
90
90
If it does not stop gas leakage, discharge whole refrigerants from the serice port.
6
After flaring work again and vacuumize, fill up prescribed refrigerant from the gas cylinder.
3-way valve
Service port
4
90
for 6 sec.
3-way valve
6
6
8
After attaching the each caps, check the gas leakage around the caps.
CAUTION:
If the refrigerant of the air conditioner leaks, it is necessary to make all the refrigerant out, then charge the liquid refrigerant into air conditioner according to the amount marked on the name plate.
14
3-way valve
Valve rod cap
7
3-way valve
7
Valve rod cap
Service port cap
7
INSTALLATION MANUAL FOR INDOOR UNIT
1. Safety precautions
Please read these "Safety Precautions" first then accurately execute the installation work. Though the precautionary points indicated herein are divided under two headings, and , those points which are related to the strong possibility of an installation done in
CAUTION
error resulting in death or serious injury are listed in the section. However, there is
WARNING
also a possibility of serious consequences in relationship to the points listed in the section as well. In either case, important safety related information is indicated, so by all means, properly observe all that is mentioned. After completing the installation, along with confirming that no abnormalities were seen from the operation tests, please explain operating methods as well as maintenance methods to the user (customer) of this equipment, based on the owner's manual. Moreover, ask the customer to keep this sheet together with the owner's manual.
WARNING
This system should be applied to places as office, restaurant, residence and the like. Application to inferior environment such as engineering shop could cause equipment malfunction. Please entrust installation to either the company which sold you the equipment or to a professional contractor. Defects from improper installations can be the cause of water leakage, electric shocks and fires. Execute the installation accurately, based on following the installation manual. Again, improper installations can result in water leakage, electric shocks and fires. When a large air-conditioning system is installed to a small room, it is necessary to have a prior planned countermeasure for the rare case of a refrigerant leakage, to prevent the exceeding of threshold concentration. In regards to preparing this countermeasure, consult with the company from which you perchased the equipment, and make the installation accordingly. In the rare event that a refrigerant leakage and exceeding of threshold concentration does occur, there is the danger of a resultant oxygen deficiency accident. For installation, confirm that the installation site can sufficiently support heavy weight. When strength is insufficient, injury can result from a falling of the unit.
Execute the prescribed installation construction to prepare for earthquakes and the strong winds of typhoons and hurricanes, etc. Improper installations can result in accidents due to a violent falling over of the unit. For electrical work, please see that a licensed electrician executes the work while following the safety standards related to electrical equipment, and local regulations as well as the installation instructions, and that only exclusive use circuits are used. Insufficient power source circuit capacity and defective installation execution can be the cause of electric shocks and fires. Accurately connect wiring using the proper cable, and insure that the external force of the cable is not conducted to the terminal connection part, through properly securing it. Improper connection or securing can result in heat generation or fire. Take care that wiring does not rise upward, and accurately install the lid/service panel. Its improper installation can also result in heat generation or fire. When setting up or moving the location of the air conditioner, do not mix air etc. or anything other than the designated refrigerant (R407C) within the refrigeration cycle. Rupture and injury caused by abnormal high pressure can result from such mixing. Always use accessory parts and authorized parts for installation construction. Using parts not authorized by this company can result in water leakage, electric shock, fire and refrigerant leakage.
WARNING
CAUTION
CAUTION
Execute proper grounding. Do not connect the ground wire to a gas pipe, water pipe, lightning rod or a telephone ground wire. Improper placement of ground wires can result in electric shock. The installation of an earth leakage breaker is necessary depending on the established location of the unit. Not installing an earth leakage breaker may result in electric shock. Do not install the unit where there is a concern about leakage of combustible gas. The rare event of leaked gas collecting around the unit could result in an outbreak of fire. For the drain pipe, follow the installation manual to insure that it allows proper drainage and thermally insulate it to prevent condensation. Inadequate plumbing can result in water leakage and water damage to interior items.
15
INSTALLATION MANUAL FOR INDOOR UNIT
NOTICE
All Wiring of this installation must comply with NATIONAL, STATE AND LOCAL REGULATIONS. These instructions do not cover all variations for every kind of installation circumstance. Should further information be desired or should particular problems occur, the matter should be referred to your local distributor.
WARNING
BE SURE TO READ THESE INSTRUCTIONS CAREFULLY BEFORE BEGINNING INSTALLATION. FAI­LURE TO FOLLOW THESE INSTRUCTIONS COULD CAUSE SERIOUS INJURY OR DEATH, EQUIPMENT MALFUNCTION AND/OR PROPERTY DAMAGE.
(1) Preparation of indoor unit
Before or during the installation of the unit, assemble necessary optional panel etc. depending on the specific type.
(2) Select places for installation satisfying following conditions and at the same time obtain the consent on the part of your client user.
(a) Places where chilled or heated air circulates freely. When the installation height exceeds 3m warmed air stays close to the ceiling. In such cases, suggest our client users to install air circulators. (b) Places where perfect drainage can be prepared and sufficient drainage. (c) Places free from air disturbances to the suction port and blowout hole of the indoor unit, places where the fire alarm may not malfunction or short-circuit. (d) Places with the environmental dew-point temperature is lower than 28 C and the relative humidity is less than 80%. (When installing at a place under a high humidity environment, pay sufficient attention to the prevention of dewing such as thermal insulation of the unit. ) (e) Ceiling height shall have the following height.
Installation space
100 or
100 or
more
more
50 or more
Combination with silent panel
366mm
1000 or more
Obstacle
(3) Avoid installation and use at those places listed below.
(a) Places exposed to oil splashes or steam (e.g. kitchens and machine plants). Installation and use at such places incur deteriorations in the performance or corrosion with the heat exchanger or damage in molded synthetic resin parts. (b) Places where corrosive gas (such as sulfurous acid gas) or inflammable gas (thinner, gasoline, etc) in generated or remains. Installation and use at such places cause corrosion in the heat exchanger and damage in molded synthetic resin parts. (c) Places adjacent to equipment generating electromagnetic waves or high-frequency waves such as in hospitals. Generated noise may cause malfunctioning of the controller.
16
Unit: mm
INSTALLATION MANUAL FOR INDOOR UNIT
(4) Preparation for suspending the unit
(a) Figure of installation dimension: (unit: mm)
1024
452
100
55
225
When install the duct hidden type indoor unit, the return air box must be designed and installed, as Figure3, Figure4. The distance between the air outlet of duct and the air outlet of air conditioner should be no more than 1m.
The distance between the air outlet of duct and the air outlet of air conditioner should be no more than
1.0m(use white motor plug); The distance between the air outlet of duct and the air outlet of air conditioner should be no more than
5.0m(use red motor plug).
225
123
22
Standard pressure 0 Pa , Middle pressure 50Pa
Building roof of installation
990
(Figure 3)
1.0m (use white motor plug)
5.0m(use red motor plug)
Ceiling
Air supply
Air outlet grille
Air supply
There should be no obstacles within 1m
Unit
Unit
Return air
17
A
Return air box
Return air
(Figure 4)
Return air box
INSTALLATION MANUAL FOR INDOOR UNIT
M8 wide expansion screw bolt
M8 hoisting screw
M8 wide lock washer
M8 screw nut
B
B amplified
Rivet
B
Air supply passage
B
Use screw to fix top panel
28
Air supply passage
A amplified
Unit
C
C amplified
Top panel of unit
Air outlet grille
(Figure 5)
(Figure 6)
Install the hoisting screw
Use M8 or M10 hoisting screw (4, prepare on site) (When the height of hoisting screw is more than 0.9m, you must use M10), their gaps refer to the dimension of air conditioner, according to the original structure and the following method to install.
Wood structure
Put up the frame wood on the beam and mount the hoisting screws.
Frame wood
Hoisting screw
Beam
New cement panel
Use embedded parts and foot screw, etc to mount.
Iron
Foot screw (Knife type embedded part)
(Louver type embedded part)
(hoisting foot screw for connection pipe)
18
INSTALLATION MANUAL FOR INDOOR UNIT
Original cement panel
Use the in hole hinge, in hole plug or in hole screw.
Steel structure
Directly use angle steel or new angle steel for support.
Suspending of indoor unit
Fix the cap of hoisting screw on and suspend them on the T groove of the hoisting part of the unit. Use gradienter to keep the level degree of the unit within 5mm.
!
In order to normally drain water, the drain hose should be mated according to the installation manual. In order to avoid dew-forming, thermal insulation treatment should be done. Improper connection pipe may cause water enter indoor.
Requirements:
The indoor side drain hose should be thermal insulated. The parts connected with indoor unit should be thermal insulated. Improper thermal insulation may cause dew-forming phenomenon. The drain hose should be downwards slant (over 1/100) and there should be no S-shaped bend. Otherwise, abnormal sound may occur. The horizontal length of the drain hose should be less than 20m. If the connection pipe is too long, the supporting frame should be set every 1.5~2m to prevent pipe from rise and fall. For the centralized connection pipe, please perform work as the following Figure shown. Pay attention not to exerting external force to the connection part of the drain hose.
Hoisting screw
Notice
Suspending bolt
Angle steel for support
1m~1.5m
Supporting frame
Downward slant over 1/100
Thermal insulation material (user self-provided)
As large as possible (about 10cm)
VP30
Downward slant over 1/100
S-shaped bend
Wall
Outside
Slant
Drain hose (user self-provided)
19
INSTALLATION MANUAL FOR INDOOR UNIT
Material of connection pipe and thermal insulation
Material of connection pipe Material of thermal insulation
Stiff PVC pipe VP 20mm (inside diameter)
Foam polyethylene pipe, thickness over 10mm
Confirm drainage
Perform test run to insure the condition of drainage, the connection part of the connection should not leak water. The confirmation must be performed even if install in winter.
!
Warning
During installation, if refrigerant leakage occurs, please immediately take ventilation measure. If the refrigerant gas meet the fire, it may generate poisonous gas. After finishing installation work, please make sure there is no refrigerant leakage. If the leaked refrigerant gas meet heater and oven, etc. fire sources, it may generate poisonous
Material and dimension of connection pipe
Depenbing on the outdoor unit.For details,please refer to the operation manual attached with outdoor unit.
The permitted length and fall of connection pipe
.
Material of connection pipe
Dimension of connection pipe
Connection of refrigerant pipe
When performing the connection work of flare nut, connect all the refrigerant pipe. When connecting the connection pipe of indoor unit, must use two spanners to perform. For the installation torque, please refer the following Table.
External diameter of connection pipe (mm)
9.52 24.5(2.5kgf.m) 29.4(3.0kgf.m)
15.88
Phosphorus oxidized copper seamless pipe (TP2) for air conditioner
Gas side Liquid side
Installation torque (N.m)
78.4(8.0kgf.m)
20
15.88
9.52
Perform with two spanners
Add to installation torque (N.m)
98.0(10.0kgf.m)
INSTALLATION MANUAL FOR ELECTRIC WIRING
5. Electric wiring
Cautions: Use copper wire only.Parameters of connecting line : H05RN-F 4G0.75mm2 ; Parameters of power supply line : H07RN-F 3G2.5mm2. Power supply :1PH,220-230V~,50Hz, connect from outside.
Wiring methods:
1.Wiring method of ring terminal
For connecting line which end is a ring,its wiring method as shown in the right figure: remove wiring screw and pass it through the end ring of connecting line,then connect it to the terminal block and tighten screw.
2. Wiring method of straight terminal
For connecting line which end is not a ring, its wiring method as follows: loosen wiring screw ans insert the end of connecting line totally into the terminal block,then tighten the screw and pull the connecting line slightly to confirm that it is clamped firmly.
Crimp connection method of connecting line
After finishing wiring.connecting line must be fastened by wire clamp,which pressed on the external sheath of the connecting line, as shown in the right figure:
Wiring of indoor unit
Open air inlet grill Take the leading end of connecting line Connect connecting line according to wiring methods
and wiring diagram of indoor and outdoor unit Fasten connecting line according to crimp connection
method of connecting line. Reinstall air inlet grill.
1.Installation fixing
Fix outdoor unit on the installation bracket firmly using bot(M10) and nut, and keep it on horizontal level. When installing on the wall or on the roof ,fix the bracket, firmly to prevent earthquake or storm. Be sure to use rubber-damping cushion to reduce unit vibration.
Wiring method of ring terminal
Correct crimp connection of wire
Terminal block
1 2 3
L N
1 2 3
to power supply
1(L)
Incorrect crimp connection of wire
Crimp connection clamp
Indoor unit terminal block
Outdoor unit terminal block
2.Installation of drain elbow
Installation of drain elbow.(Only for heat pump type air conditioner, no drain elbow for single cooling type).If use drain elbow,please install as shown in the figure. Do not use drain elbow in cold place (temperature successively below 0 C)
3. Connection of outdoor piping
Connect the connecting pipe according to the piping connection method
4.Wiring connection
1.Open the wiring cover and loosen the wiring clamp.
2.Lead the connecting wire out and pass it through the wiring clamp.
3.Connect the connecting wire according to the wiring method and diagram
4. Confirm the ends of wire are connected well, safe and correct.
5. After finishing wiring, press the connecting wire according to the wire crimp connection method and reinstall the cover.
21
Terminal
Wire clamp
Power supply
Connecting wire between inner and outer
INSTALLATION MANUAL FOR WIRE CONTROLLER
1.Remove the upper cover of wire controller
The PC board is installed on the back cover of wire controller. When remove the upper cover, pay attention not to damage PC board.
Upper cover of wire controller
HEALTH
C
F
SET RECOVERY
CHECK
Back cover of wire controller
2.Install wire controller
**Drill 2 wall holes according to the position of the 2 screw holes on the back *cover of wire controller, then hit wood in the wall holes. Put the 2 screw holes *on the back cover of wire controller properly to its corresponding wood, then *use wood screws to fix the back cover on the wall.
Note:
Install the back cover of wire controller on the even wall as possible as can. When tightening the wood screw , do not use to tight force, otherwise the wire controller may be damaged.
Note: When connecting wire, please keep a certain distance between signal wire and electric wire. (over 10mm)
Dimension of signal wire:
Type of wire Dimension
Shield wire (4 cords)
0.33mm
2
3.Indoor unit wire connection
Connect the terminals (A, B, C, D,) on the wire controller to the terminals on the indoor PC panel (A, B, C, D,) respectively.
Arrange wire from this part
AB CD
Back cover
HEALTH
C
F
wire controller
SET RECOVERY
CHECK
HEALTH
C
F
CHECK
SET RECOVERY
Upper cover of wire controller
The connection between indoor unit and wire controller and indoor unit and outdoor unit should use shield wire. And the two ends of the shield wire should be grounded, otherwise, the disturbance will cause unit abnormal operation.
Shield wire
Grounded
Grounded
Note: Confirm the connection part of terminals is firm and will not touch shield wire.
4. Cover the wire controller upper cover
Pay attention not to press the connection wire.
Note: Do not touch PC board by hand.
22
CHECK AND TEST RUN
Other instruction
1.Set of the air sending of the fan motor
Before leaving factory, the rotation speed of fan motor has already been set at standard choice.
When the indoor unit uses free air sending and not needing to connect with duct, the fan speed of indoor unit is set at standard choice. When the indoor unit needs to connect with duct, please according to the following figure shown to change the connection of the connector installed on the side of electric box.
Standard pressure (Before leaving factory)
One side of the control box
Connector(White)
(White)
Middle pressure
One side of the control box
Connector(White)
(Red)
One side of Fan motor One side of Fan motor
The relative relation between fan speed and static pressure
Standard pressure
2. Cut and flaring method
Use pipe cutter to cut the pipe, the burrs must be removed.
After inserting the flarer, perform flared nut.
Flarer
A
Correct
Slant
Flaring dimensions as follows:
Connent pipe Liquid pipe Gas pipe
Broken
Pipe diameter
9.52mm (3/8'')
15.88mm (5/8'')
Burrs Too long
Incorr
Uncompleted
Middle pressure
50
Dimension A (mm)
1.0-1.2
1.4-2.2
3.Configuration of power supply
Air conditioner must use special power supply system (above 20A), and qualified electrician makes wiring and fixing according to wiring regulations specified in national standard.
In socket, exactly distinguish earth wire with neutral wire and it is wrong to connect them together. A leakage breaker must be installed.
Parameters of power supply: H07RN-F 3G 2.5mm Connection method is Y-connection .If the power cord is damaged, it must be replaced by
professional people of manufacturer or its maintenance department or similar to avoid dangers.
2
4.Installation check and test run
Require customers to use air conditioner according to the operation manual. The items checked during test run,please mark in
Is the wiring of indoor and outdoor unit secured firmly? How about the thermal insulation of the pipe joint: Is the electrical wiring between indoor and outdoor unit
connected to the terminal block firmly? Is the display on the control board (LCD) correct?
Cooling normal? Does the indoor temperature regulator work normally? Is the power supply voltage conformed to the electrical
regulation?
23
No gas leakage on the pipe joint ? Is the drainage hose arranged correct? Is the earthing wire connected firmly? Any noise? For the power supply 1 shall be connected to the live wire. 2 shall be connected to the neutral wire.
Shall be connected to the earth wire.
Unit: Pa