This product must only be installed or serviced by qualified personnel.
Please read this manual carefully before installation.
Keep this operation manual for future reference.
Original instructions
Haier Industrial Park, No.1 Haier road, Qingdao,P.R.China
EUROPEAN REGULATIONS
CONFORMITY FOR THE MODELS
CE
All the products are in conformity with the following
European provision:
-Low voltage Directive
-Electomagnetic CompatibilitY
ROHS
The products are fulfilled with the requirements in the
directive of the European parliament and of
council on the Restriction of the use of Certain Hazardous
Substances in Electrical and Electronic Equipment(EU
RoHS Directive)
WEEE
In accordance with the directive 2012/19/EU of the European
parliament,herewith we inform the consumer about the disposal requirements of the electrical and electronic products.
DISPOSAL REQUIREMENTS:
conditioning system,treatment of the refrigerant,of oil and of
other part must be done by a qualified installer in accordance
with relevant local and national legislation.Air conditioners
must be treated at a specialized treatment facility for reuse,
recycling and recovery.By ensuring this product is disposed
of correctly,you will help to prevent potential negative consequences for the environment and humen health.Please
contact the installer or local authority for more information.
Battery must be removed from the remote controller and disposed of separately in accordance with relevant local and
nationl legislation.
2011/65/EU
Your air conditioning product is marked with this
symbol.This means that electrical and electronic
products shall not be mixed with unsorted
household waste.Do not try to dismantle the
system yourself:the dismantling of the air
IMPORTANT INFORMATION REGARDING THE REFRIGERANT USED
Contains fluorinated greenhouse gases
covered by the Kyoto Protocol
R410A
This product contains fluorinated greenhouse gases covered
by the Kyoto Protocol.Do not vent into the atmosphere.
GWP:2088
Refrigerant type:R410A
WP=global warming potential
G
Please fill in with indelible ink,
1 the factory refrigerant charge of the product
2 the additional refrigerant amount charged in the field
and
1+2 the total refrigerant charge
on the refrigerant charge label supplied with the product.
The filled out label muset be adhered in the proximity of the
product charging port(e.g.onto the inside of the stop value
cover).
A contains fluorinated greenhouse gases covered by the
Kyoto Protocol
B fatory refrigerant charge of the product:see unit name
plate
C additional refrigerant amount charged in the field
D total refrigerant charge
E outdoor unit
F refrigerant cylinder and manifold for charging
kg
kg
kg
A
B
C
D
WARNING
If the supply cord is damaged, it must be replaced by the manufacturer, its service agent or similarly qualified persons in
order to avoid a hazard.
This appliance is not intended for use by persons (including children) with reduced physical, sensory or mental capabilities,
or lack of experience and knowledge, unless they have been given supervision or instruction concerning use of the appliance
by a person responsible for their safety.
Children should be supervised to ensure that they do not play with the appliance.
This appliance can be used by children aged from 8 years and above and persons with reduced physical, sensory or
mental capabilities or lack of experience and knowledge if they have been given supervision or instruction concerning use
of the appliance in a safe way and understand the hazards involved. Children shall not play with the appliance. Cleaning
and user maintenance shall not be made by children without supervision.
The appliances are not intended to be operated by means of an external timer or separate remote-control system.
Keep the appliance and its cord out of reach of children less than 8 years.
WARNING
Do not use means to accelerate the defrosting process or to clean, other than those recommended by the manufacturer.
The appliance must be stored in a room without continuously operating ignition sources(for examples: open flames, an operating gas appliance
or an operating electric heater).
o not pierce or burn.
D
Be aware that refrigerants may not contain an odour.
If the supply cord is damaged, it must be replaced by the manufacturer, its service agent or similarly qualified persons in order to avoid a hazard.
This appliance can be used by children aged 8 years and above and persons with reduced physical,sensory or mental capabilities or lack of
experience and knowledge if they have been given superivision or instruction concering use of the appliance in a safe way and understand the
hazards involved. Children shall not play with the appliance. Cleaning and user maintenance shall not be made by children without supervision.
The wiring method should be in line with the local wiring standard.
All the cables shall have got the European authentication certificate. During installation, when the connecting cables break off, it must be
assured that the grouding wire is the last one to be broken off. The explosion-proof breaker of the air conditioner should be all-pole switch.
Distance between it’s two contacts should not be no less than 3mm. Such means for disconnection must be incorporated in the wiring.
Make s
ure installation is done according to local wiring regulation by professional persons.
Make sure ground connection is correct and reliable. A leakage explosion-proof breaker must be installed.
The installation and service of this product shall be carried out by professional personnel, who have been trainedand certified by national training
organizations that areaccredited to teach the relevant national competency standards that may be set in legislation.
Mechanical connectors used indoors shall comply with ISO 14903. When mechanical connectors are reused indoors, sealing parts shall be
renewed. When flared joints are reused indoors, the flare part shall be re-fabricated.
This appliance is intended to be used by expert or trained users in shops
, in light industry and on farms, or for commercial use by lay persons。
Disconnect the appliance from its power source during service and when replacing parts
The maximum working pressure is 4.15 MPa.This maximum working pressure shall be considered when connecting the outdoor unit to indoor
units.
The refrigerant suitable for the indoor unit is R410A. The indoor unit shall only be connected to outdoor unit suitable for the same refrigerant.
The unit is a partial unit air conditioner, complying with partial unit requirements of the International Standard, and must only be connected to
other units that have been confirmed as complying to corresponding partial unit requirements of the International Standard.
The A-weighted sound pressure level is below 70 dB.
Cautions
Disposal of the old air conditioner
Before disposing an old air conditioner that goes out of use, please make sure it's inoperative and safe. Unplug the air conditioner
in order to avoid the risk of child entrapment.
It must be noticed
materials contained in a air conditioner can be recycled. Contact your local waste disposal center for proper disposal of an old
air conditioner and contact your local authority or your dealer if you have any question. Please ensure that the pipework of your
air conditioner does not get damaged prior to being picked up by the relevant waste disposal center, and contribute to environmental
awareness by insisting on an appropriate, anti-pollution method of disposal.
Disposal of the packaging of your new air conditioner
All the packaging materials employed in the package of your new air conditioner may be disposed without any danger to the
environment.
The cardboard box may be broken or cut into smaller pieces and given to a waste paper disposal service. The wrapping bag
made of polyethylene and the polyethylene foam pads contain no fluorochloric hydrocarbon.
All these valuable materials may be taken to a waste collecting center and used again after adequate recycling.
Consult your local authorities for the name and address of the waste materials collecting centers and waste paper disposal
services nearest to your house.
Safety Instructions and Warnings
Before starting the air conditioner, read the information given in the User's Guide carefully. The User's Guide contains very
important observations relating to the assembly, operation and maintenance of the air conditioner.
that air conditioner system contains refrigerants, which require specialized waste disposal. The valuable
The manufacturer does not accept responsibility for any damages that may arise due to non-observation of the following
instruction.
Damaged air conditioners are not to be put into operation. In case of doubt, consult your supplier.
Use of the air conditioner is to be carried out in strict compliance with the relative instructions set forth in the User's Guide.
Installation shall be done by professional people, don't install unit by yourself.
For the purpose of safety, the air conditioner must be properly grounded in accordance with specifications.
Always remember to unplug the air conditioner before opening inlet grill. Never unplug your air conditioner by pulling on the
power cord. Always grip plug firmly and pull straight out from the outlet.
All electrical repairs must be carried out by qualified electricians. Inadequate repairs may result in a major source of danger for
the user of the air conditoiner.
Do not damage any parts of the air conditioner that carry refrigerant by piercing or perforating the air conditioner's tubes with
sharp or pointed items, crushing or twisting any tubes, or scraping the coatings off the surfaces. If the refrigerant spurts out and
gets into eyes, it may result in serious eye injuries.
Do not obstruct or cover the ventilation grille of the air conditioner. Do not put fingers or any other things into the inlet/outlet and
swing louver.
Do not allow children to play with the air conditioner. In no case should children be allowed to sit on the outdoor unit.
This appliance is not intended for use by persons (including children) with reducedphysical, sensory or mental capabilities, or
lack of experience and knowledge, unless they have been given supervision or instruction concerning use of the appliance by
a person responsible for their safety.
Children should be supervised to ensure that they do not play with the appliance.
3
Safety Precautions
Before starting to
use the system, read carefully this "SAFETY PRECAUTIONS" to ensure a proper operation of the system.
Safety precautions described here are classified to " WARNING" and " CAUTION". Precautions which are shown
in the column of " WANING" means that an improper handing could lead to a grave result like a death, serious injury,
etc. However, even if precautions are shown in the column of " CAUTION", a very serious problem could occur depending
on situation. Make sure to observe these safety precautions faithfully because they are very important information to ensure
the safety.
Symbols which appear frequently in the text have following meanings.
Strictly prohibited.
When you have
Observe instructions faithfully
read through the manual, keep it always at hand for read consultation. If the operator is replaced, make
.
Provide a positive grounding.
sure to hand over this manual to the new operator.
CAUTIONS FOR INSTALLATION
WARNING
ice,
The system should be applied to places as off
restaurant, residence and the like.
Application to inferior environment such as an
engineering shop, could cause equipment
malfunction and serious injury or death.
Do not install nearby the place where may have
leakage of flammable gas.
The
a professional installer.
Installation by yourself is not encouraged because
it could cause such problems as water leakage,
electrical shock or fire accident by some improper
handing.
Depending on the place of installation, a circuit
breaker may be necessary.
should be installed by your dealer or
system
CAUTION
When you need some optional devices such as a
humidifier, electric heater, etc., be sure to use the products
which are recommended by us. These devices should
be attached by a professional installer.
Installation by yourself is not encouraged because it could
cause such problems as water leakage, electrical shock
or fire accident by some improper handing.
Drain pipe should be arranged to provide a positive
draining.
ON
OFF
If the gas leakes and gathers around, it may cause
the fire.
Where strong winds may prevail, the system
should be fixed securely to prevent a collapse.
Bodily injury could result by a collapse.Bodily injury could result by a careless installation. Grounding cable should never be connected to
CAUTIONS FOR TRANSFER OR REP
Modification of the
repair, consult your dealer.
system is strictly prohibited. When the system needs a
Unless the circuit breaker is installed, it could cause
elecrical shocks.
Install on the place where can endure the weight
of air conditioner.
AIR
WARNING
When the air conditioner is relocated, contact your dealer or a professional
installer.
If the pipe is arranged improperly, furniture or the
likes may be damaged by leaked water.
Make sure the system is grounded.
a gas pipe, city water pipe, lightning conductor
rod or grounding cable of telephone. If the
grounding cable is not set properly, it could cause
electric shocks.
Improper practice of
fire.
repair could cause water leakage, electric shock or
Improper practice of installation could cause water leakage, electric shock
or fire.
4
Safety Precautions
CAUTIONS FOR OPERATION
You should
to cool wind for a long time.
refrain from exposing your body directly
WARNING
Do not poke the air inlet or outlet with a bar, etc. When any abnormal condition (scorching smell or
others) is found, stop the operation immediately
and turn off the power switch. Then consult your
dealer.
It could affect your physical condition or cause
some health problems.
The system should never be used for any other
purposes than intended such as for preservation
of food, flora and fauna, precision devices or work
of art.
problems.
Do not wash the air conditioner with water.
It could cause electric shocks.
Neither stand on the air conditioner nor
place something on it.
object.
Do not use the power switch to turn on or off the
system.
It could cause a fire or water leakage.There is a risk of injury.If the system is operated at the vicinity of such
When operating the system simultaneously with
a combustion apparatus, indoor air must be
ventilated frequently.
ON
OFF
Since the internal fan is operating with a high
speed, it could cause an injury.
CAUTION
Do not handle switches with a wet hand.Combustion apparatus should not be placed
It could cause electric shocks.It could cause deterioration of food or other
Do not install the system where the air outlet
reaches directly the flora and fauna.
It will not be good for their health.Use
It is strictly prohibited to place a container of
combustible gas or liquid near the air conditioner
or to spray it directly with the gas or liquid.
Do not touch the air outlet section while the swing
louver is operating.
Check occasionally the support structure of the
unit for any damage after a use of long period of
time.
If you continue the operation without removing the
cause, it could result in a trouble, electric shock
or fire.
allowing a direct exposure to wind of air conditioner.
Incomplete combustion could occur on the
apparatus.
Make sure to use a fuse of proper electric rating.
steel or copper wire in place of a fuse is
of
strictly prohibited because it could result in a trouble
or fire accident.
Do not operate the system while the air outlet grill
is removed.
There is a risk of injury.It could cause a fire accident.There are risks of falling or injury by collapsed
Do not use such equipment as a water heater, etc.
around the indoor unit or the wire controller.
equipment which generates steam, condensed
water may drip during cooling operation or it could
cause a fault current or short-circuit.
When cleaning the
turn off the power switch.
system, stop the operation and
Insufficient ventilation could cause an oxygen
deficiency accident.
Do not put water containers on the unit such as a flower vase, etc.
If the water enters into the unit and damages the electric insulation material, it may cause electric shock.
If the structure is not repaired immediately, the
unit could topple down to cause a personal injury.
Cleaning should never be done while the internal
fans are running with high speed.
5
The machine is adaptive in following situation
1. Applicable ambient temperature range:
Cooling
Heating
Indoor temperature
Outdoor temperature
Indoor temperature
Outdoor temperature
max. DB/WB
min. DB/WB
max. DB/WB
min. DB/WB
max. DB/WB
min. DB/WB
max. DB/WB
min. DB/WB
32/23 C
18/14 C
46/26 C
10/6 C
27 C
15 C
24/18 C
-15 C
2. If the supply cord is damaged, it must be replaced by the manufacturer or its service agent or a similar qualified person.
If the fuse on the indoor PC board is broken please change it with the type of T 3.15A/250V(For
3.
AD125,AD140S2SM3FA,AD125,AD140S2SM4FA),or the type T 5A/250V(For
AD90,AD105S2SM3FA,AD90,AD105S2SM4FA)
4. The wiring method should be in line with the local wiring standard.
5. The power cable should be:
H05RN-F 3G 4.0mm²(outdoor unit 1UH071/090/105N1ERG),or H05RN-F 3G 6.0mm²(outdoor unit 1UH125/140P1ERG),
or H05RN-F 5G 4.0mm²(outdoor unit 1UH125/140P1EK),
The connecting cable should be:
H05RN-F 4G 2.5mm
2
All the cables shall have got the European authentication certificate. During installation, when the connecting cables break off,
it must be assured that the grouding wire is the last one to be broken off.
6. The power cable and connect cable should be self-provided.
7. The breaker of the air conditioner should be all-pole switch, and the distance between its two contacts should be no
less than 3mm.
8. The indoor unit installation height is at least 2.5m.
9. A leakage breaker must be installed.
10.
For AD90S2SM3FA/AD90S2SM4FA/AD105S2SM3FA/AD105S2SM4FA/AD125S2SM3FA/AD125S2SM4FA/
AD140S2SM3FA/AD140S2SM4FA
,wecan get the 10 different ESP through adjust wired controllerYR-E17,please refer
In the state of ON and non screen saving state, press Fan+ Set keys for
5 seconds to enter static pressure grade adjustment state with static pressure icon flashing and current static pressure
grade statically displaying. Press key↑↓ to change static pressure grade, then press Set key to confirm.
Details please refer to wired controller operation & installation manual.
Adjsutment metchod by Infrared remote controller+Infrared receiver RE-02:Step a:set the Infrared remote controller at
condition: FAN m ode ,fan speed high Step b:then aim the remote controller at the infrared remote receiver RE-02,
press HEALTH button 4+N times(1≤N≤10,integer)within 12 seconds ,then the receiver will beep N+1 times ,the
static pressure level N is been set successfully.
Note:For Infrared remote controller YR-HBS01, need press ON/OFF button make the controller’s at OFF status first,then
open the button cover press FRESH button will enter FAN mode interface.