Haier Acd125e Owner's Manual

English
English
English
English
English
English
English
English
English
English
English
English
English
English
English
English
PREPARE UNIT
2
FOR INSTALLATION-2
1. Remove the screws which fasten the cabinet at both sides and at the back.
2. Slide the unit from the cabinet by gripping the base pan handle and pulling forward while bracing the cabinet.
3. Insert the Frame Guide into the bottom of the cabinet.
Caution: Never expose plastic front or grille to extreme temperatures.
3
Install top rail with three 13/32"screws. Slide left-hand curtain assembly into left end of top and bottom rails. Repeat for right-hand curtain assembly. Fasten curtain retainer strips to sides of outer case with eight 13/32" screws.
ASSEMBLE CURTAINS/TOP RAIL
Shipping Screws
PREPARE
4
WINDOW FOR INSTALLTION
Inspect window track, sash, and sill for its ability to support the weight of air conditioner.
Measure width between window moldings to ensure Instant Mount will fit window frame. Instant Mount models are designed for windows wide (the detail see page 15)
Instant Mount kit supplied with unit is designed for mounting in most double-hung windows without storm windows. For installation in window frame with storm window, modify sill by adding wood strips (not included) to inner and outer sills. This raises unit and eliminates interference of storm window frame.
16
Storm window installation
If storm window frame does not allow adequate clearance below sill (1/2" required), remove storm window frame or create clearance by adding a wood strip (at least 1 1/2" wide) along entire width of sill. Fasten wood strip to sill with at least three countersunk wood screws (not supplied with kit). This provides a smooth surface for mounting air conditioner.
1/2"
1 1/2"
Minimum
Wood
SILL
I N D O O R
Storm Window Frame
Stri p
Minimum
O U T D O O R
Mobile home window installation
Add wood strip (at least 1 1/2" wide) along entire width of window sill. Thickness of wood strip should match height of front lip on window frame. Fasten wood strip to sill with a minimum of three countersunk wood screws (not supplied with kit). This provides a smooth surface for mounting air conditioner.
Must be a minimum
of 1/2" to clear
bottom rail on unit
11/2"
Minimum
N D O O R
Wood
Strip
I
Window
Frame
O U T D O O R
INSTALL OUTER
5
CASE IN WINDOW
Place outer case in window. Lower sash until it rests behind front flange of top rail. Bottom rail must rest behind window sill.
Top rail
Bottom rail
Curtain assembly cut
away for clarity.
About
Expand both curtains to contact the window frame. Attach each curtain
the window sash using 31/32" screws.
NOTE: To make screws easier to drive, drill a pilot hole into sash through clearance hole in curtains.
English
Use 3 screws(31/32") to fix the case to windows sash.
17
English
6
Install sash bracket on top of indoor window sash with one wood screw 31/32" to prevent raising of window from the outside. Screw anchor directly into side of window frame. For hard wood or metal window frames, drill a pilot hole to start screw.
Important:Be careful not to drill pilot hole too deep. Add a piece of tape to the drill bit as a depth gauge. Also stay clear of glass. Be careful not to damage the function of the window.
Cut window seal gasket to width of window. Stuff window seal strip between outdoor window glass and top of indoor sash. This will stop air leakage which reduces efficiency.
7
The base pan may overflow due to high humidity. You must install the drain tube before using the unit. Adjust the direction of the drain tube to make it be in line with the hole in the rear of unit; Insert the drain tube into the hole and twist 90¡ª. To drain the excess water to indicated position, connect a drainpipe to the drain tube. When pressing the drain tube or drainpipe into place, apply force in the direction away from the fins to avoid injuring yourself.
INSTALL SASH BRACKET & SEAL GASKET
INSTALL DRAIN TUBE
RETURN
8
CHASSIS TO OUTER CASE
Find someone to help you replace chassis in outer case. Replace front panel, and grille. (Don't forget to install the attachment screws before replacing grille)
Caution:
For security purpose, reinstall screws at cabinet's sides.
Important:
Because window sash helps keep unit in window, make certain window sash contacts outer case before reinstalling chassis.
18
Care and Cleaning Guide
Always unplug your air conditioner before cleaning.
The air filter behind the inlet grille should be checked and cleaned at least once every 2 weeks (or as necessary) to maintain optimal performance of the air conditioner.
How to remove the air filter
1. The grille may be opened from the top for easy maintenance after installation.
2. Open the inlet grille by pulling off the exposed door on the top of the unit(based on the installation).
3. Pull the tab slightly to release the filter. Pull the filter in the same direction as the opening.
4. Clean the filter with warm, soapy water. The water should be below
o
C(104oF).
40
5. Rinse off and gently shake off excess water from the filter. Let it dry before replacing it.
DO NOT use your air conditioner without the air filter in place.
English
To clean the front panels or the cabinet DO NOT use harsh chemicals, abrasives, ammonia, chlorine, bleach, concentrated detergents, solvents or metal scouring pads. Some of these chemicals
may dissolve, damage and/or discolor your air conditioner.
Always use a soft cloth dampened with water or mild soap and water solution to wipe the front of the cabinet.
Wipe dry with a soft cloth.
19
English
TroubleShooting
To store your air conditioner, after the season, remove the unit from the window as per the installation guide. Repack the unit in its original box and store away. If your unit is installed in a wall or you do not intend to remove it from the window then cover the outside with a winter cover. This can be purchased from the retailer where you purchased your air conditioner or from your local hardware store.
Before putting away your unit make sure any water left in the pan is removed and drained away'. Water left in the pan could lead to Rusting or damage to the electrical connections.
If air conditioner does not operate:
Check if unit is plugged in. The plug may have come loose. Check if the unit is in "Off" mode.
Air from air conditioner is warm:
The COOL setting may need to be raised.
Ice formation on cooling coils:
Outside temperature too cold. Set the unit on fan only setting to defrost ice. Lower temperature setting. Temperature setting may be too cold, Unit BTU may be too high for the room.
20
English
Air conditioner working but room not cooling:
Room may have appliances that produce heat. Use an exhaust fan to remove excess heat. Redirect the airflow Remove any obstacles. Al doors and windows need to be closed so cool air does not escape the room. Air filter may need cleaning. Unit BTU may be too low for the required cooling area. On extreme hot & humid days air conditioners may take a little longer to cool Vent may be in the open position. Vent has to be closed for optimum cooling.
Air conditioner is making noise when cooling:
You may hear sounds of air movement, water, compressor clicking on and off or window vibrations. Read Operating Guide- Normal Operating Sounds. (See page 8)
Water in the air conditioner cabinet:
This is normal as your air conditioner not only cools but also dehumidifies the air. If there is water dripping inside the room, check the installation of the unit. The unit may need to be reinstalled. (See page 17)
21
English
ROOM AIR CONDITIONG AND DEHUMIDIFIER PRODUCTS
Limited Warranty
What is covered and for how long?
This warranty covers all defects in workmanship or materials for a period of: 12 months for labor 12 months for parts (Functional Parts Only) 5 years for sealed system The warranty commences on the date of item purchase. Customer shall provide Amana with proof of the date of purchase, brand, model and serial number for verification prior to any warranty service being provided. EXCEPTIONS: Commercial or Rental Use warranty 90 days for labor 90 days for parts No other warranty applies
What is covered/Not covered?
1. The mechanical and electrical parts of the appliance which serve the functional purpose of this appliance are covered for a period of 12 months. This includes all parts except finish and trim.
2. Manufacturing defects to the components of the sealed system (e.g. hermetic compressor, condenser and evaporator) are covered for a period of 5 years from the date of purchase. Any damages to such components caused by mechanical abuse, improper handling or shipping will not be covered.
3. The limited warranty does not cover any credit or refund for any loss or injury caused by the product or defects to the product including but not limited to incidental or consequential damages.
What will be done?
1. Any mechanical or electrical part that proves to be defective in normal usage during the specified warranty period will be repaired or replaced at Amanas discretion. A&E factory service is the authorized service provider for Amana. If it is determined that repair is not appropriate or replacement part is unavailable for repair, Amana will exchange the product with a refurbished or new product the same or similar to the original at its discretion.
2. There will be no charge to the purchaser for functional replacement parts and labor on any covered items during the initial 12- month period. Beyond this period, only the components of the sealed system are covered, labor is not provided and must be paid for by the customer.
3. To have your product serviced, please contact Amana customer service 1-888-842-2440.
THIS WARRANTY COVERS APPLIANCES WITHIN THE CONTINENTAL UNITED STATES, PUERTO RICO AND CANADA. IT DOES NOT COVER THE FOLLOWING:
Damages from improper installation. Damages incurred during shipping. Defects other than manufacturing.
Damage from misuse, abuse, accident, alteration, lack of proper care and maintenance or incorrect current or voltage. Damage from other than household use. Damage from service by other than an authorized dealer or service center. Decorative trims or replaceable light bulbs. Transportation and shipping. Labor (after the initial 12 months). Credit or Refund for products over 30 days past date of purchase Food loss for food spoiled as a direct result of mechanical failure of the product or of any delay in providing service, repair, replacement. This limited warranty doesnt apply to refurbished product or unit purchased as/like new or second-hand. THIS LIMITED WARRANTY IS GIVEN IN LIEU OF ALL OTHER WARRANTIES, EXPRESSED OR INCLUDING THE WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE The remedy provided in this warranty is exclusive and is granted in lieu of all other remedies. This warranty does not cover incidental or consequential damages, so the above limitations may not apply to you. Some states do not allow limitations on how long an implied warranty lasts, so the above limitations may not apply to you. This warranty gives you specific legal rights, and you may have other rights, which vary from state to state.
For more information on this and other Amana
products, call Customer Affairs Department at:
1-888-842-2440
CONSUMER INFORMATION LINE
Amana Toll-Free
1-888-842-2440
(Not a technical assistance line for dealers.)
22
Loading...