Haier AC182ACBBA user guide manual

Operation Manual
No. 0010541266
CONVERTIBLE TYPE ROOM AIR CONDITIONER
AC182ACMBA AU182AFMBA (HCFU-18CC03) AC182ACABA AU182AFABA (HCFU-18HC03) AC182ACNAA AU182AFNBA (HCFU-18CA03/R1) AC182ACBBA AU182AFBBA (HCFU-18HC03/R1)
CONTENTS
CAUTIONS
...........................................................
FEATURES AND FUNCTIONS
.............................................
NAME OF PARTS
................................................... ..
INTRODUCTION TO SPARE PARTS
.................................... ...
REMOTE CONTROLLER OPERATION
.........................................
GUIDE TO OPERATION
.................................................
CLEANING AND CARE
..................................................
TROUBLE SHOOTING
...................................................
WHEN PROBLEMS OCCUR
................................................
OPERATING TIPS
................................................. ...
1-2 3 4 5-6 7 8-15 16-17 18 19 20
1
CAUTIONS
Disposal of the old air conditioner
Before disposing an old air conditioner that goes out of use, please make sure it's inoperative and safe. Unplug the air conditioner in order to avoid the risk of child entrapment.
It must be noticed that air conditioner system contains refrigerants, which require specialized waste disposal. The valuable materials contained in a air conditioner can be recycled. Contact your local waste disposal center for proper disposal of an old air conditioner and contact your local authority or your dealer if you have any question. Please ensure that the pipework of your air conditioner does not get damaged prior to being picked up by the relevant waste disposal
Disposal of the packaging of your new air conditioner
All the packaging materials employed in the package of your new air conditioner may be disposed without any danger to the environment.
The cardboard box may be broken or cut into smaller pieces and given to a waste paper disposal service. The wrapping bag made of polyethylene and the polyethylene
All these valuable materials may be taken to a waste collecting center and used again after adequate
Consult your local authorities for the name and address of the waste materials collecting centers and waste paper disposal services nearest to
Safety Instructions and Warnings Before starting the air conditioner,
read the information given in the User's Guide carefully. The User's Guide contains very important observations relating to the assembly, operation and maintenance of the air conditioner.
The manufacturer does not accept responsibility for any damages that may arise due to non-observation of
Damaged air conditioners are not to be put into operation. In case of doubt, consult your supplier.
Use of the air conditioner is to be carried out in strict compliance with the relative instructions set forth in the User's Guide.
Installation shall be done by professional people, don't install
2
CAUTIONS
D
L
K1
For the purpose of safety , the air conditioner must be properly grounded in accordance with specifications.
Always remember to unplug the air conditioner before opening inlet grill. Never unplug your air conditioner by pulling on the power cord. Always grip plug firmly and pull straight out from the outlet.
All electrical repairs must be carried out by qualified electricians. Inadequate repairs may result in a major source of danger for the user of the air conditoiner.
Do not damage any parts of the air conditioner that carry refrigerant by piercing or perforating the air conditioner's tubes with sharp or pointed items, crushing or twisting any tubes, or scraping the coatings off the surfaces. If the refrigerant spurts out and gets into eyes, it may result in serious eye injuries.
Do not obstruct or cover the ventilation grille of the air conditioner. Do not put fingers or any other things into the inlet/outlet and swing louver.
Do not allow children to play with the air conditioner. In no case should children be allowed to sit on the outdoor unit.
Specifications
The refrigerating circuit is leak-proof.
When installation in under ceiling, dial switch "K1" in the PC board to "D" position. When installation in floor console, dial switch to "L" position (Brand new unit is in "D" position).
FEATURES AND FUNCTIONS
3
AUTOMATIC OPERATION
COOLING TYPE
HEAT & COOL TYPE
Merely press the ON/OFF button, and the unit will begin automatic operation in the Cooling or Dry mode as appropriate, in accordance with the thermostat setting and the actual temperature of the room.
Merely press the ON/OFF button, and the unit will begin automatic operation in any of the Heating, Cooling and Blow modes as appropriate, in accordance with the thermostat setting and the actual temperature of the room.
WIRELESS REMOTE CONTROL UNIT
The WIRELESS REMOTE CONTROL UNIT allows convenient control of air conditioner operation.
MILDEW-RESISTANT FILTER
The AIR FILTER has been treated to resist mildew growth, thus allowing cleaner use and easier care.
NAME OF PARTS
4
Fig.4
Fig.3
Fig.1 Indoor Unit
Operating Control Panel (Fig.2) Emergency switch Remote Control Signal Receiver Power Indicator Lamp (Red) OPERATION Indicator Lamp (Green) TIMER Indicator Lamp (Yellow) Compressor Run Lamp (Green) Intake Grill (Fig.3) Air Filter UP/DOWN Air Direction Flaps RIGHT/LEFT Air Direction Louvers (behind UP/DOWN Air Direction Flaps) Power Plug
Fig.4 Outdoor Unit
Intake port Outlet port Pipe Unit
1 2 3
4
5 6
7
8
9 10 11
12
15 16 17
16
15
17
4
6
7
3
3
1
9
8
Fig.1
Fig.2
POWER OPER TIMER COMP
EMER
2
12
1110
5
INTRODUCTION TO SPARE PARTS
5
Buttons and display of the remote
Operation
CLOCK
MODE
SWING
Power ON/OFF
TEMP
FAN
SLEEP
SET
HOUR
RESET
LOCK
TIMER
Used for unit start and
Used to set auto fan
Used to select AUTO run, COOL,DRY,HEAT and
Used to set correctUsed to set correct
Used to select TIMER ON, TIMER OFF, TIMER ON/OFF.
Used to lock buttons
Used to reset the controller
Used to set clock and
Used to confirm Timer
Used to select sleep mode.
Used to select fan speed: LO, MID, HI, AUTO
Used to select your
Cautions: On cooling only unit, heating mode is not available. After replacing batteries, press ON/OFF, and display becomes as follows:
Note:
1. The above information is theexplanation of the displayed information therefore varies with those displayed in actual operation.
2. This type only has the relevant function
T
SWING
FAN
ON
OFF
MODE
SLEEP
SET
CLOCK TIMER
LOCK RESET
A
O O
AM PM
AM PM
INTRODUCTION TO SPARE PARTS
6
Hints
LO
MID
HI
AUTO
AUTO
Buttons and display of the remote controller.
Operation
DRY
COOL
AUTO
SWING
FAN SPEED
SLEEP
Clock set
TIMER ON
TIMER OFF
LOCK
CLOCK
TEMP.
SIGNAL SENDING
FAN OPERATION
HEAT
When unit is started for the first time and after replacing batteries in remote controller, clock should be adjusted as follows: Press CLOCK button, "AM" or "PM" flashes.
Press or to set correct time. Each press will increase or decrease 1min. If the button is kept depressed, time will change quickly. After time setting is confirmed, press SET, "AM "and "PM" stop flashing, while clock starts working.
After replacing with new batteries, remote controller will conduct self-check, displaying all information on LCD. Then, it will become normal.
TEMP
SWING
FAN
ON
OFF
MODE
SLEEP
SET
CLOCK TIMER
LOCK RESET
AUTO
ON OFF
AM PM
AM PM
REMOTE CONTROLLER OPERATION
7
TEMP
SWING
FAN
ON
OFF
MODE
SLEEP
SET
CLOCK TIMER
LOCK RESET
AM
When in use, put the signal transmission head directly to the receiver hole on the indoor unit. The distance between the signal transmission head and the receiver hole should be within 7m without any obstacle as well. Don't throw the controller, prevent it from being damaged. When electronic-started type fluorescent lamp or change-over type fluorescent lamp or wireless telephone is installed in the room, the receiver is apt to be disturbed in receiving the signals so the distance to the indoor unit should be shorter.
Loading of the battery
Load the batteries as illustrated. 2R-03 batteries, resetting key (cylinder)
Remove the battery cover :
Slightly press " " and push down the cover.
Load the battery :
Be sure that the loading is in line with the " + " / " - " pole request as illustrated.
Put on the cover again Confirmation indicator :
In disorderation, reload the batteries or load the new batteries after 5mins.
Note :
Use two new same-typed batteries when loading. If the remote controller can't run normally or doesn't work at all, use a sharp pointed item to press the reset key .
Hint :
Remove the batteries in case unit won't be in usage for a long period. If there is any display after taking-out just need to press reset key.
Remote controller's operation
GUIDE TO OPERATION
8
FAN operation
Remote controller can memorize settings in each operation mode. T o run it next time just select the operation mode and it will start with the previous setting. No reselecting is needed.(TIMER ON/OFF needs reselecting)
Hints
(1) Unit start
(2) Select operation mode
(3) Fan
(4) Unit stop
AUTO COOL DRY HEAT FAN
Press ON/OFF button, unit starts. Previous operation status appears on display . (Not Timer setting) Power indicator on indoor unit lights up.
Press MODE button. For each press, operation mode changes as follows:
Unit will run in selected mode. stop display at " " FAN.
Press F AN button. For each press, fan speed changes as follows:
Unit will run at selected fan speed. Adjust air flow direction if necessary , refer to page10.
Press ON/OFF button. Only time remains on LCD. All indicators on indoor unit go out. V ertical flap closed automatically .
LO
MID HI
TEMP
SWING
FAN
ON
OFF
MODE
SLEEP
SET
CLOCK TIMER
LOCK RESET
AM
2
4
1
3
GUIDE TO OPERATION
9
AUTO run, COOL,HEAT and DRY operation
Use COOL in summer. Use HEA
T in winter.
Use DRY in spring,autumn and in damp climate.
(1) Unit start
(2) Select operation mode
(3) Select temp.setting
Press ON/OFF button, unit starts. Previous operation status appears on display
.(Not Timer setting)
Power indicator on indoor unit lights up.
Press MODE button. For each press, operation mode changes as follows:
Unit will run in operation mode displayed on LCD. Stop display at your desired mode.
Hints
Unit will start running to reach the temp. setting on LCD.
Remote controller can memorize each operation status. When starting it next time, just press ON/OFF button and unit will run in previous status.
AUTO COOL DRY HEAT FAN
Press TEMP button Every time the button is pressed, temp. setting increases 1 C Every time the button is pressed, temp. setting decreases 1 C
Recommendations
TEMP
WING
AN
ON
OFF
MODE
SLEEP
SET
CLOCK
TIMER
LOCK RESET
AM
1
4
3
2
3
6
5
GUIDE TO OPERATION
10
Press F AN button. For each press, fan speed changes as follows:
(4) Fan speed selection
Unit runs at the speed displayed on LCD. In HEA
T mode, warm air will blow out after a short period of time due to cold-draft prevention function. In DRY mode, when room temp. becomes 2 C higher than temp. setting, unit will run intermittently at LO speed regardless of FAN setting.
AUTO
LO
MID HI AUTO
Press ON/OFF button. Only time remains on LCD. All indicators on indoor unit go out. V ertical flap closes automatically .
(6) Unit stop
As cold air flows downward in COOL mode, adjusting air flow horizontally will be much more helpful for a better air circulation. As warm air flows upward in HEA
T mode, adjusting air flow downward will be much more helpful for a better air circulation. Be careful not to catch a cold when cold air blows downward. It is harmful to your health in summer to go frequently in and out of places where temp. difference is above 7 C . Temp. difference of 3-5 C will remove your fatigue. More than this, unit's load can be reduced and power consumption cut down as well. So, you'd better set a temp. diff of 3-5 C between indoor and outdoor temp. in COOL mode.
Hints
COOL operation sta s when room tep highe tha temp seting.
On reaching temp. seting,nit will un in mild DR
Y mode.
Ulta- ar flow
Temp. setting+2 C Tmp setting
(5) Air flow direction adjust
After operation mode is selected, vertical flap will open automatically according to the mode.
GUIDE TO OPERATION
11
TIMER operation
Hints
Set Clock correctly before starting Timer operation(refer to page 6)
Y ou can let unit start or stop automatically at following times: Before you wake up in the morning, or get back from outside or after you fall asleep at night.
TIMER ON/OFF
(1)After unit start, select your desired operation mode. Operation mode will be displayed on LCD. Power indicator on indoor unit lights up.
(2)TIMER mode selection
Press TIMER button to change TIMER mode. Every time the button is pressed, display changes as follows:
Select your desired TIMER mode (TIMER ON or TIMER OFF) ON or OFF will flash.
(3)Timer setting
Press HOUR button.
Every time the button is pressed, time increases 10min. If button is kept depressed, time will change quickly
. Every time the button is pressed, time decreases 10min. If button is kept depressed, time will change quickly. Time will be shown on LCD. It can be adjusted within 24hours.
(4)Confirming your setting
After setting correct time, press SET button to confirm "ON" or "OFF" stops flashing T
ime displayed: Unit starts or stops at x hour x min (TIMER ON or TIMER OFF). Timer mode indicator on indoor unit lights up.
To cancel TIMER mode
Just press TIMER button several times until TIMER mode disappears.
After replacing batteries or a power failure happens, Time setting should be reset. Remote controller possesses memory function, when use
TIMER mode next time, just
press SET button after mode selecting if timer setting is the same as previous one.
ON
OFF
ON
OFF
blank
TIMER OFFTIMER ON TIMER ON-OFF
TEMP
SWING
FAN
ON
OFF
MODE
SLEEP
S T
CLOCK TIMER
LOCK RESET
ON
AM
2
1
4
3
3
GUIDE TO OPERATION
12
Every time the button is pressed, time increases 10min. If button is kept depressed, time will change quickly . Every time the button is pressed, time decreases 10min. If button is kept depressed, time will change quickly. Time will be shown on LCD. It can be adjusted within 24hours. AM refers to morning and PM to afternoon.
TIMER ON-OFF
Operation mode will be displayed on LCD. Power indicator on indoor unit lights up.
(3)Time setting for TIMER ON
(4)Time confirming for TIMER ON
After time setting, press TIMER button to confirm. "ON" stops blinking,
While "OFF" starts blinking.
Time displayed: Unit starts at Xhour X min.
To cancel TIMER mode
Just press TIMER button several times until TIMER mode disappears. According to the
Time setting sequence of TIMER ON or TIMER OFF, either Start-Stop or
Stop-Start can be achieved.
Press HOUR button.
(1)After unit start, select your desired operation mode
Every time the button is pressed, display changes as follows:
(2)Press TIMER button to change TIMER mode
ON
OFF
ON
OFF
blank
TIMER OFFTIMER ON TIMER ON-OFF
Select TIMER ON-OFF , "ON" will flash.
(5)Time setting for TIMER OFF
Follow the same procedures in "Time setting for TIMER ON".
(6)Time confirming for TIMER OFF
After time setting, press SET button to confirm "OFF" stops flashing. T
ime displayed: Unit starts at Xhour X min.
TEMP
SWING
FAN
ON
OFF
MODE
SLEEP
SET
CLOCK
TIMER
LOCK ET
ON
AM
2
1
6
3
5
OFF
PM
4
GUIDE TO OPERATION
13
Adjusting up/down air flow direction
Up/down direction can be adjusted by using the SWING button on the remote controller. Each time pressing this button, the mode changes in the following sequence.
SWING
No indication (louver stopped)
Change to the AIRFLOW mode.
SWING
LOUVER STOPPED
Louver moves in upward and downward directions continuously .
When the LOUVER button is pushed during SWING mode, it stops swinging at the just angle.
Recommendable stopping angle of the louver
A void direct air flow to the body for many hours. Avoid downward blowing opera­tion of cooling mode for many hours. Do not touch the swing louver during swing operation.
CAUTION
COOL and DRY
HEAT
(Horizontal Blowing)
(Downward Blowing)
GUIDE TO OPERATION
14
about 6 hrs
1 hr
1 hr
increase 1 C
increase 1 C
Comfortable Sleep
At night, before going to bed you can press down the SLEEP button on the controller and the air
-conditioner will run by the comfortable sleeping mode
to make you sleep more comfortable.
One hour after sleeping operation start, the temp. is 1 C higher than the setting one.
After another hour the temp. rises 1 C and then run continuously for another 6hrs' and then close. The actual temp. is higher than the setting one which is to prevent from being too cool to your sleep.
In cooling, dehumiditying mode
Press SLEEP button once to make the air conditioner have t e previous-set sleep time (first power
-on is "1h"), the sleep symbol will appear Press time button / , you can choose the time in 1~8 hours. Each press of / , the time increases/reduces 1 hour and "Xh" appears in he temperature setting part, "OFF" appears in "TIMER OFF" display part and timer-off time; press SLEEP button again to cancel sleep function, the sleep symbol diappears.
One hour after start up, the temp. decrease 2 C lower than setting one.
After another hour decrease by more 2 C. The temperature will automatically rise by 1 C after another 3hrs' operation, and then automatically close after 3hrs' continuous operation. The actral temperature is lower than the setting one which is to prevent from being too hot to your sleep.
In heating mode
Note: In
AUTO mode, unit will run in SLEEP function according to the operation mode. After setting SLEEP function, it is forbidden to calibrate clock. If the set sleep-time does not reach 8 hours, the unit will stop operation time is complete. Change "TIMER-OFF" first, then set SLEEP, and press the sleep-set-perf ON function first, the sleep function can only be set before TIMER-ON; if s first, the TIMER function can not be set. After setting SLEEP, press CLOCK button to show the time; press TEMP. temperature; press again to change temperature.
TEMP
SWING
FAN
ON
OFF
MODE
SLEEP
SET
CLOCK TIMER
LOCK RESET
AM
SETTING T
SLEEP RUN BEGINS SLEEP RUN STOPS
1 hr
1 hr
3 hrs
about 3 hrs
decrease 2 C
decreases 2 C
increase1 C
SHUT DOWN
SLEEP RUN STOPS
Heat mode
SLEEP RUN BEGINS
SETTING T
SHUT DOWN
Cooling mode
GUIDE TO OPERATION
15
Remote Contro
The indoor unit. instruction man cputzed d otrled from a faraway place.
Power Failure Comp
Seting Method: When the remote
the state of power failure compensation.
Cancel Methd: Pres the "Sleping"
mode will be cancelled.
Notes: When a power after t a long time, after the pow again.
Aft conditioner is again.
CLEANING AND CARE
16
CAUTION!
Before cleaning the air conditioner ,be sure to turn it off and di the Power Supply Cord. Be sure the Intake Grill is installed securely
. When removing and replacing the air filters, be sure not to touch exchanger, as personal injury may result.
Cleaning the Air Filter
Open the Intake Grill
1. Pull out both sides and the center
of the
Intake Grill.
2. Pull the Air Filters upward to remove them.
3. Clean the Air Filters.
5 Push in both sides and the center of the Intake Grill.
4. Re-attach the Air Filters to the Intake Gri
Push the Air Filter handles away from the Intake Grille in direction as illustrated, then pull out
Air Filters.
Remove the dust from the Air Filters by vacuum cleaner or washing them.
After washing, allow the Air Filters to dry thoroughly in an area protected from sunlight.
1
2
3
The Filters fit onto the inside of the in Grill. (figure 1) The bottom edges of the
Air Filters shoul fit into the filter brackets. (figure 1) The Air Filters should be pushed down so that their top edges fit under the project at the top of the Intake Grill. (figure 2
Dust can be cleaned from the Air either with a vacuum cleaner
, or by washin the filter in a solution of mild dete warm water. If you wash the filter, to allow it to dry thoroughly in a place before reinstalling. If dirt is allowed to accumulate on Filter, air flow will be reduced, operating efficiency and increasing noise During periods of normal use, th Filters should be cleaned every two weeks
(Figure 1)
Filter bracket
Air Filter
(Figure 2)
Handle
Air Filter
Bracket
Base
About 30 mm
Arm
Intake Grill
Arm
Notch
Hook
Side Panel
CLEANING AND CARE
17
When used performanc cleaning When clea cleansers, o Do not e When shut continuousl
Dote: If the fuse on the PC board is broken, please change it with
the type of 50F, 2
TROUBLE SHOOTING
18
Followings are not problems
Sound of water flowing is not a problem.
Sound of cracking is heard.
Smell are generated.
During operation, white fog or steam comes out from the indoor unit.
No outlet air or fan speed can't be changed in dry mode.
In cooling operation, unit switches to blowing operation.
Won't start?
In heating operation, water or steam are blown out of outdoor unit.
In heating operation, indoor fan won't stop even if unit is stopped.
During unit operation or at stop, a swishing or gur
gling noise may be heard. This noise is generated
by refrigerant flowing in the system.
Unit will not restart after stop.
During unit operation, a cracking noise may be heard. This noise is generated by the casing expanding or shrinking because of temperature changes.
This is because the system circulates smells from the interior air such as the smell of cigarettes or the painting on the furniture.
When unit is running at places like restaurant, etc. w dense edible oil fumes always exist, this will happen.
To prevent frost from accumulating on indoor heat exchanger
, unit will switch to blowing operation for a
while then resume cooling operation. Though ON/OFF button is set
to ON, unit won't resume cooling, dry or heating operation in 3 min after it is stopped, this is because of 3-min-delay protection circuit.
Please wait 3 minutes
Unit will reduce fan speed repeatedly and automatical if room temp. is too low in dry operation.
This occurs when frost accumulated on the outdoor unit is removed. (during defrosting operation)
After unit stop, indoor fan will go on running until indoor unit cools down.
WHEN PROBLEMS OCCUR?
19
Before ask for services, please first check your unit against the following.
Air conditioner won't start.
Poor cooling or heating
Is power supply switch turned on?
Power supply switch is not set at ON.
Is city power supply norma ?Is leakage current breaker
activated? This is very dangerous, please
disconnect power supply immediately and contact your dealer
.
Are operation control adjusted correctl as specified?
Is air filter too dirty?
Are there any obstacles in inlet or outlet grill?
Are horizontal louvers at up position (in heating mode)?
Any doors or windows left open?
Is there any direct sunlight in the room?
If there are unexpected heat sources in the room?
Too many people in the room?
Poor cooling
Is air conditioner in standby condition in heating mode?
Cold air blows out (in heating mode)
If your unit still can't work properly after above mentioned checks, or following problems occur, please stop it immediately and contact your dealer. Fuses or circuit breakers often blow out.
Water comes out in cooling/dry operation.
Operation is abnormal or sound is heard.
Power failure?
Proper temp
OPERATING TIPS
20
Operation and Performance
*Heating Performance
*Microcomputer-controlled Automatic Defrosting
Heat-pump air conditioners heat your entire room by recirculating air throughout the room, with the result that some time may be required after first starting the air conditioner until the room is heated.
This air conditioner operates on the heat-pump principle, absorbing heat from outdoor air and transferring that heat indoors.
As a result, the operating performance is reduced as outdoor air temperature drops. If you feel that insufficient heating perfomance is being produced, we recommend you use this air conditioner in conjunction with another kind of heating appliance.
Instructions relating to heating (*) are applicable only to "HEAT & COOL TYPE".
When using the Heating mode under conditions of low outdoor air temperature high humidity
, frost may form on the outdoor unit,
resulting in reduced operating performance. In order to prevent this kind of reduced
performance, this unit is equipped with a Microcomputer
-controlled Automatic Defrosting function. If frost forms, the air conditioner will temporarily stop, and the defrosting circuit will operate briefly (for about 7 to 15 minutes).
During Automatic Defrosting operation, the OPERATION Indicator Lamp will flash.
Temperature and Humidity Range
Cooling
Heating
indoor
outdoor
indoor
outdoor
max C D.B/W.B min C D.B/W.B
max C D.B/W.B min C D.B
max C D.B min C D.B
max C D.B/W.B min C D.B/W.B
32/23 18/14
43/26 18
32/­15/-
24/18
-7/-8
If the air conditioner is used under higher temperature condition than those listed, protection circuit may operate to prevent internal circuit damag
e. Also, during Cooli modes, if the unit is used under conditions of lower temperature than those listed ab heat-exchanger may freeze, leading to water leakage and other damage. Do not use this unit for any other purposes except for the Cooling, (*) Heating, Dehu and air-circulation of rooms in ordinary dwellings.
Loading...