Haier 2HUM18HC03-R2, 2U14CS1ERA, 2HUM14HC03-R2, 2U18FS1ERA INSTALLATION

ROOM AIR CONDITIONER
INSTALLATION MANUAL
Contents
2U14CS1ERA
2HUM14HC03/R2(DB)
2U18FS1ERA
2HUM18HC03/R2(DB)
Indoor/Outdoor Unit Installion Drawings
Safety Precautions
Read Before Installation
Installation Procedure
Outdoor Unit Troubleshooting
1
2
6
9
Please read this manual carefully before installtion.
Keep this operation manual for future reference.
NO.0010535388
Haier Industrial Park, No.1 Haier Road, Qingdao, P.R.China
EUROPEAN REGULATIONS CONFORMITY FOR THE MODELS
CE
All the products are in conformity with the following European provision:
- Low Voltage Directive 73/23/EEC
- Low Voltage Directive 2006/95/EC
-Electomagnetic CompatibilitY 89/336/EEC
-Electomagnetic CompatibilitY 2004/108/EC
ROHS
The products are fulfilled with the requirements in the directive 2002/95/EEC of the European parliament and of
council on the Restriction of the use of Certain Hazardous Substances in Electrical and Electronic Equipment (EU RoHS Directive)
WEEE
In accordance with the directive 2002/96/CE of the European
parliament, herewith we inform the consumer about the dis­posal requirements of the electrical and electronic products.
DISPOSAL REQUIREMENTS:
Your air conditioning product is marked with this symbol.This means that electrical and electronic
products shall not be mixed with unsorted household waste. Do not try to dismantle the
system yourself : the dismantling of the air conditioning system,treatment of the refrigerant, of oil and of other part must be done by a qualified installer in
with relevant local and national legislation. Air conditioners must be treated at a specialized treatment facility for reuse,
recycling and recovery. By ensuring this product is disposed
of correctly, you will help to prevent potential negative cons­equences for the environment and humen health. Please contact the installer or local authority for more information. Battery must be removed from the remote controller and dis­posed of separately in accordance with relevant local and
nationl legislation.
accordance
IMPORTANT INFORMATION REGA­RDING THE REFRIGERANT USED
Contains fluorinated greenhouse gases covered by the Kyoto Protocol
R410A
2
1=
2=
1
1+2=
FE
This product contains fluorinated greenhouse gases covered by the Kyoto Protocol. Do not vent into the atmosphere.
Refrigerant type:R410A GWP* value:1975
GWP=global warming potential
Please fill in with indelible ink,
• 1 the factory refrigerant charge of the product
• 2 the additional refrigerant amount charged in the field and
• 1+2 the total refrigerant charge on the refrigerant charge label supplied with the product. The filled out label must be adhered in the proximity of the product
cover).
A contains fluorinated greenhouse gases covered by the Kyoto B factory refrigerant charge of the product: see unit name plate
C additional refrigerant amount charged in the field D total refrigerant charge
E outdoor unit F refrigerant cylinder and manifold for charging
charging port (e.g. onto the inside of the stop value
Protocol
kg
kg
kg
A
B
C
D
Indoor/Outdoor Unit Installation Drawings
ThemodelsadoptHFCfreerefrigerantR410A.
For installation of the indoor units,refer to the installation manual which was provided with the units. (The diagram shows a wall-mounted indoor unit.)
Attention must be paid to
the rising up of drain hose
more than 15cm
Optional parts for piping
more than
10cm
Arrangement of piping directions
Indoor unit A
Indoor unit B
more than 10cm
F
C
Non-adhesive tape
A
Adhesive tape
B
Saddle (L.S) with screws
C
Connecting electric cable
D
forindoorandoutdoor
E
Drain hose
F
Heating insulating material
Piping hole cover
G
Rear left
Left
Below
The marks from to
ƽ
G
in the figure are the parts numbers. The distance between
ƽ
the indoor unit and the floor should be more than 2m.
Rear right
Right
A
more than 10cm
more than
60cm
more than 10cm
4
Fixing of outdoor unit
Fix the unit to concrete or blockƽ
with bolts (10mm) and nuts firmly
D
E
more than15cm
and horizontally.
ƽ
When fitting the unit to wall
surface, roof or rooftop, fix
a supporter surely with nails
or wires in consideration of
earthquake and strong wind.
ƽ
If vibration may affect the
house, fix the unit by attaching a
vibration-proof mat.
AIR OUTLET
AIR INLET
CONNECTING PIPING AND ELECTRICAL WIRING
DRAIN HOSE
Compressor(Inside of Unit)
ƽ
The above indoor and outdoor units’ picture is just for your reference. Please be subject to the actual product purchased.
1
WARNING
CAUTION
2
Safety Precautions
WARNING
Have the unit professionally installed. Improper installation by an unqualified person may result in water leak, electric shock, or fire.
Place the unit on a stable, level surface that withstands the weight of the unit to prevent the unit from tipping over or falling causing injury as a result.
Only use specified cables for wiring. Securely connect each cable, and make sure that the cables are not straining the terminals. Cables not connected securely and properly may generate heat and cause fire.
Take necessary safety measures against typhoons and earthquakes to prevent the unit from falling over.
Do not make any changes or modifications to the unit. In case of problems, consult the dealer. If repairs are not made properly, the unit may leak water and present a risk of electric shock, or it may produce smoke or cause fire.
WARNING
Be sure to carefully follow each step in this handbook when installing the unit. Improper installation may result in water leak, electric shock, smoke or fire.
Have all electrical work performed by a licensed electrician according to the local regulations and the instructions given in this manual. Secure a circuit designated exclusively to the unit. Improper installation or a lack of circuit capacity may cause the unit to malfunction or present a risk of electric shock, smoke,and fire.
Securely attach the terminal cover(panel) on the unit. If installed improperly, dust and/or water may enter the unit and present a risk of electric shock, smoke or fire.
Only use refrigerant R410A as indicated on the unit when installing or relocating the unit. The use of any other refrigerant or an introduction of air into the unit circuit may cause the unit to run an abnormal cycle and abnormal cycle and cause the unit to burst.
Do not touch the fins on the heat exchanger with bare hands, for they are sharp and dangerous.
In the event of a refrigerant gas leak, provide adequate ventilation to the room. If leaked refrigerant gas is exposed to a heat source, noxious gases may form.
With All-Fresh type air conditioners, outdoor air may be directly blown into the room upon thermo off. Take this into consideration when installing the unit. Direct exposure to outdoor air may present a health hazard, and it may also cause food items to deteriorate.
Do not try to defeat the safety features of the devices, and do not change the settings. Defeating the safety features on the unit such as the pressure switch and temperature switch or using parts other than the dealer or specialist may result in fire or explosion.
When installing the unit in a small room, safeguard against hypoxia that results from leaked refrigerant reaching the threshold level. Consult the dealer for necessary measures to take.
When relocating the air conditioner, consult the dealer or a specialist. Improper installation may result in water leak, electric shock, or fire.
After completing the service work, check for a refrigerant gas leak. If leaked gas refrigerant is exposed to a heat source such as fan heater,stove,and electric grill, noxious gases may form.
Only use specified parts. Have the unit professionally installed. Improper installation may cause water leak, electric shock,smoke, or fire.