HAI 74A00-1 Quick Start Guide

Page 1
Register at: cloud.leviton.com
Leviton’s Cloud Service makes connecting to a LUMINA Gateway quick and simple for both installation companies and users. Registration is required for remote access and to obtain software.
Download and Install LUMINA Gateway Setup Software
Once an account has been activated on cloud.leviton.com, download the free setup software for PC’s.
Unbox the LUMINA Gateway
Remove the LUMINA Gateway from the box. Locate the power plug and Ethernet cable as they will be utilized for installation.
Installation Wizard
For installation, enrollment, and programming, please open the setup software on your computer and utilize the on-screen prompts to complete.
Enjoy!
Lumina™ Gateway Quick Start Installation Guide
1. Register at: cloud.leviton.com
O Browse to cloud.leviton.com and request
t
o create a new account
O Complete the setup form and check
t
he e-mail address for a registration
confirmation
O Open the confirmation e-mail and follow
t
he steps to complete the registration
R All registrations must be confirmed
to a
ctivate an account.
2. Download and Install Software
O Browse to cloud.leviton.com and log in
w
ith the newly created account
O Download the latest revision of LUMINA
G
ateway software
O The PC should have an active Internet
co
nnection before running the installer
O Run the installer
O During the installation process you will
b
e prompted for a security password
R
When prompted for LCS credentials enter the username and password from step 1.
3. Unbox and Connect the Lumina Gateway
O Review the opposite side of these
i
nstructions to power the LUMINA Gateway
O The LUMINA Gateway LED 1 w
ill blink once per second to let you know it is ready to be discovered
4. Installation Wizard
O Create a new project to start the
Inst
allation Wizard
O The Wizard will step through the following
k
ey steps
R Discover the LUMINA Gateway on
t
he network
R Name the LUMINA Gateway and
reg
ister to Leviton Cloud Service for app
connections
R Set location information for sunrise /
sunse
t calculations.
5. You are now ready to add LUMINA RF devices, create new users, and write schedules and logic
O
Help in software
O
Dealer site support
O
Enjoy your LUMINA Gateway!
leviton.com
© 2015 Leviton Mfg. Co., I nc.
For Technical Assistance Call: 800 -824-3005 – www.leviton.com.
PK-A3066-10-00-0B (74I00-1)
PK-A3066-10-00-0B
(74I00-1)
Once the Lumina™ Gateway is installed and operational, install the Lumina Mobile app on each user's Apple or Android device.
WEB VERSION
Page 2
Lumina Gateway – Cat. Nos. 74A00-1
COPYRIGHT AND TRADEMARK INFORMATION
This document and all its contents herein are subject to and protected by international copyright and other intellectual property rights and are the property of Leviton Manufacturing Co., Inc, its subsidiaries, affiliates and/or licensors. Use herein of third party trademarks, service marks, trade names, brand names and/or product names are for informational purposes only, are/may be the trademarks of their respective owners; such use is not meant to imply affiliation, sponsorship, or endorsement. No part of this document may be reproduced, transmitted or transcribed without the express written permission of Leviton Manufacturing Co., Inc.
FOR CANADA ONLY
For warranty information and/or product returns, residents of Canada should contact Leviton in writing at Leviton Manufacturing of Canada Ltd to the attention of the Quality Assurance Department, 165 Hymus Blvd, Pointe-Claire (Quebec), Canada H9R 1E9 or by telephone at 1 800 405-5320.
LEVITON LIMITED WARRANTY
Leviton warrants to the original consumer purchaser and not for the benefit of anyone else that products manufactured by Leviton under the Leviton brand name (“Product”) will be free from defects in material and workmanship for the time periods indicated below, whichever is shorter: • OmniPro II and Lumina Pro: three (3) years from installation or 42 months from manufacture date. • Omni LTe, Omni IIe, and Lumina: two (2) years from installation or 30 months from manufacture date. • BitWise Controllers, Accessories: two (2) years from installation or 30 months from manufacture date. • Lumina Gateway Controllers: two (2) years from installation or 30 months from manufacture date. • Thermostats, Accessories: two (2) years from installation or 30 months from manufacture date. • Batteries: Rechargeable batteries in products are warranted for ninety (90) days from date of purchase. Note: Primary (non-rechargeable) batteries shipped in products are not warranted. Products with Windows® Operating Systems: During the warranty period, Leviton will restore corrupted operating systems to factory default at no charge, provided that the product has been used as originally intended. Installation of non-Leviton software or modification of the operating system voids this warranty. Leviton’s obligation under this Limited Warranty is limited to the repair or replacement, at Leviton’s option, of Product that fails due to defect in material or workmanship. Leviton reserves the right to replace product under this Limited Warranty with new or remanufactured product. Leviton will not be responsible for labor costs of removal or reinstallation of Product. The repaired or replaced product is then warranted under the terms of this Limited Warranty for the remainder of the Limited Warranty time period or ninety (90) days, whichever is longer. This Limited Warranty does not cover PC-based software products. Leviton is not responsible for conditions or applications beyond Leviton’s control. Leviton is not responsible for issues related to improper installation, including failure to follow written Installation and operation instructions, normal wear and tear, catastrophe, fault or negligence of the us er o r o the r p rob le ms e xte rn al t o th e Pro duc t. To vi ew c ompl ete war ra nty an d in st ruc ti on s fo r re tu rni ng p ro duc t, plea se v isi t us at www.leviton.com.
Third party trademarks are the property of their respective owners
© 2015 Leviton Mfg. Co., I nc.
For Technical Assistance Call: 800 -824-3005 – www.leviton.com.
PK-A3066-10-00-0B (74I00-1)
WARNINGS AND CAUTIONS
WARNING: TO AVOID DEATH OR SERIOUS PERSONAL INJURY never push objects of any kind into this product through openings, as they may touch dangerous voltages.
WARNING: TO AVOID DEATH OR SERIOUS PERSONAL INJURY never touch uninsulated wires or terminals unless the wiring has been disconnected at the network interface.
• Read and understand all instructions. Follow all warnings and instructions marked on the product.
Do not use this product near water - e.g., near a tub, wash basin, kitchen sink or laundry tub, in a wet basement, or near a swimming pool.
• Never install communications wiring or components during a lightning storm.
• Never install communications components in wet locations unless the components are designed specifically for use in wet locations.
• Use caution when installing or modifying communications wiring or components.
• SAVE THESE INSTRUCTIONS.
INSTALLATION
For best results, avoid areas with excessive metal or electrical wiring.
1. Unpack the LUMINA Gateway. Package includes: LUMINA Gateway, power adapter, patch cable, and this document.
2. Plug one end of the supplied network patch cable into the jack labeled “ETHERNET/LAN” on the LUMINA Gateway, marked “C” in Figure 1. Plug the
opposite end of the network patch cable into a DHCP enabled network router, switch, or hub that is on the same local network as the LUMINA Gateway.
3. Plug the barrel connector from the supplied 5VDC power adapter into the round receptacle labeled “5V” on the LUMINA Gateway, marked “D” in
Figure 1.
4. Plug the power adapter into an outlet.
OPERATION
1. When the LUMINA Gateway is powered on, it takes 15-30 seconds to cycle through the self test and acquire an IP Address from the network router.
When initially powering on, it is normal to see an immediate flicker of LED 1, followed approximately 10 seconds later by LED’s 1 & 3 on solid.
2. While the LUMINA Gateway is starting up, it takes 15 -30 seconds to become operational.
3. The LUMINA Gateway is operational when LED #1 begins to blink at a rate of once per second.
4. In normal operation, LED #3 blinks on LUMINA RF activity.
LED OPERATION
LED 1 – Blinks once per second under normal operation. LED 2 –
Identifies connectivity (on solid) when connected to Leviton® Cloud Services (LCS).
LED 3 – Blinks when LUMINA RF traffic occurs. LED 4 – NOT CURRENTLY IN USE
RESETTING TO FACTORY DEFAULTS
If it is determined that a reset to factory defaults is required, take the following steps:
1. Power down the LUMINA Gateway.
2. Press and hold the button labeled “RESET” on the LUMINA Gateway, which is marked “B” in Figure 1.
3. Power on the LUMINA Gateway while continuing to hold the “RESET” button.
4. Wait for the LED indicators 1, 2, 3, and 4 to illuminate in sequence. NOTE: When initially powering, it is normal to see an immediate flicker of LED 1,
followed approximately 10 seconds later by LED’s 1 & 3 on solid. Continue to hold until all 4 LED’s light up in sequence.
5. Release the “RESET” button within 5 seconds after all LED indicators are illuminated.
6. All LED indicators will flash off, and then back on.
7. The Factory Reset is completed once LED indicator #1 begins blinking again.
FIGURE 1
A LED INDICATORS B RESET BUTTON C ETHERNET PORT D POWER INPUTS
BACD
RESET
12
34
RS-232 RS-485 ETHERNET/LAN
USB
MICRO
USB
5 V
WEB VERSION
Loading...