Haglof Digitech, Mantax Digitech User Manual

MANTAX
Digitech®
V1.6 ENGLISH USER’S GUIDE
Digitech ENU rev. Feb 2011
Contents
Haglöf Sweden® ...................................................................................................................................................... 5
Mantax Digitech® .................................................................................................................................................... 6
Assemble the caliper jaws ....................................................................................................................................... 7
Adjust the handle ............................................................................................................................................... 8
Jaw angle ............................................................................................................................................................ 8
MENU SELECTIONS .................................................................................................................................................. 9
Battery .............................................................................................................................................................. 10
LOCAL ................................................................................................................................................................ 10
1-key registration (1But) .............................................................................................................................. 10
3-key registration ......................................................................................................................................... 10
Double scale function ....................................................................................................................................... 10
1-key registration (1But) .............................................................................................................................. 10
3-key registration ......................................................................................................................................... 11
Delete latest registration .................................................................................................................................. 11
Reading heights from Vertex and Vertex Laser Height Measurers................................................................... 11
LINE ................................................................................................................................................................... 12
CLR .................................................................................................................................................................... 13
INSP ................................................................................................................................................................... 13
COPY ................................................................................................................................................................. 13
Digitech ENU rev. Feb 2011
PC ...................................................................................................................................................................... 13
DigiCom V1.0 ......................................................................................................................................................... 14
Code .................................................................................................................................................................. 14
Name of tree species ........................................................................................................................................ 15
Edit Data ........................................................................................................................................................... 15
Delete 0-diameters ........................................................................................................................................... 15
Two 0-diameters=New plot .............................................................................................................................. 15
Three 0-diameters=New List, Stand ................................................................................................................. 15
Export data ....................................................................................................................................................... 16
Identities ........................................................................................................................................................... 16
Radius ............................................................................................................................................................... 16
Result Example Standtable ............................................................................................................................... 17
Explanations ................................................................................................................................................. 17
Example tab separated Excel txt file ................................................................................................................. 18
Data file from the caliper .................................................................................................................................. 19
Line ................................................................................................................................................................... 19
PRINT ................................................................................................................................................................ 20
RAND................................................................................................................................................................. 20
SET .................................................................................................................................................................... 21
Radio ..................................................................................................................................................................... 22
Digitech ENU rev. Feb 2011
Technical specification .......................................................................................................................................... 23
Accessories ....................................................................................................................................................... 23
IR4................................................................................................................................................................. 23
IR6................................................................................................................................................................. 23
DigiRadio V1.6 .............................................................................................................................................. 23
DigiAntenn .................................................................................................................................................... 23
Declaration of conformity ..................................................................................................................................... 24
Warranty and Service Information ................................................................................................................... 24
SOFTWARE ........................................................................................................................................................ 24
Digitech ENU rev. Feb 2011
HAGLÖF SWEDEN®
HAGLÖF SWEDEN AB IS A FAMILY OWNED COMPANY WITH A LONG TRADITION OF DEVELOPING AND PRODUCING INSTRUMENTS FOR PROFESSIONAL FOREST MEASURING WORK. TODAY, HAGLÖF SWEDEN MANUFACTURE AND SELL THE MOST COMPLETE PRODUCT RANGE FOR CRUISING AND INVENTORY WORK.
A profound know-how in workshop production technique has grown to encompass our state-of-the-art manufacturing of electronic instruments and field software.
There are over 200 companies representing the Haglöf Sweden brand name around the world. Being a manufacturer with self-owned and -run production facilities, the entire production process is under our control. This ensures availability and reliable deliveries for you, as well as prompt service and support when you need it, no matter where in the world you are located.
Every operator of a Haglöf Sweden product is a member of our innovation team. We mark our resources for product development and maintain the flexibility of a small organization.
Many Haglöf Sweden instruments are used also outside the forestry industry, such as in building dimensions and utility industry, for road construction, in police work, gardening, power line survey, archaeology, geology and for wildlife management.
Haglöf Sweden AB, Box 28, SE-882 21 Långsele, Sweden.
Phone: +46 620 255 80. Fax: +46 620 205 81. E-mail: info@haglofsweden.com
www.haglofsweden.com
Digitech ENU rev. Feb 2011
MA NTAX DIGITECH®
The Mantax Digitech® is a light weight, easy learn-easy use digital computer caliper, designed to endure any type of climate and daily use in a tough environment. The Digitech® consumes little battery and can communicate with radio signals with handheld computer and other devices. Several Digitech units can operate on an area, sending online individually separated measuring results to one handheld unit, adding value and increasing efficiency to investments and equipment.
The Digitech caliper is available in two configurations, the Digitech® Digicruise for inventory tasks (described herein), and the Digitech® Digilog, for log measuring, with 2000 registers possible and different variables (see
www.haglofsweden.com for details on the Digilog model). Diameters and up to 8 different tree species can be
captured and stored in the internal memory if not transferred online with radio signals or infrared light (IR). The Mantax Digitech® is equipped with an IR receiver for direct communication with the Haglöf Sweden® Vertex and Vertex Laser height measurers for receipt of height results.
The Digitech caliper is manufactured in three different lengths and several graduation options. For trees that are larger than the physical scale length, the Digitech can operate with a “double scale” function, enabling the user to register trees with large diameters. Digitech has with a built in generator for random pick of sample trees while cruising.
The Mantax Digitech® has jaws that can be removed and exchanged with red laser pointer Gator Eyes jaws. The red laser pointers are useful for operation in obscure surroundings and allows for diameter measuring and measuring of branches at a distance. See www.haglofsweden.com for details on the best Gator Eyes solution for your Haglöf caliper.
The Mantax Digitech® is operated through a menu based system. The keys L for left arrow key and R for right arrow key, are used to choose desired function. The E-key - Enter is used to activate the function you have chosen to work with. E is also used to turn on the Digitech caliper. To turn off, simply press both arrow keys simultaneously (ESC) when caliper is set in main menu. ESC is also used to step out of a current menu.
Enter
ESC
Left arrow key
Right arrow
key
Battery lid IR sender/transmitter
Digitech ENU rev. Feb 2011
AS SEMB LE THE CALIPER JAW S
Assemble the caliper jaws using the enclosed Allen key (wrench) and the screws with washers.
Tighten the screws using the Allen key.
Make sure the jaws are correctly assembled and guided into the material marks on your caliper.
Mount the jaw lids
4X
1X
2X
4X
Digitech ENU rev. Feb 2011
AD JUST THE HA NDLE
In the back part of the caliper handle you will find a compartment containing a small Allen key. Use the Allen key to adjust the sliders and jaw angle for perfect run and alignment.
JA W ANGLE
Adjust screw 1 until the handle runs smoothly. Adjust screws 2 and 3 for the jaws to be aligned (parallel).
Tighten screws 4, 5 and 6 for the handle to run smoothly.
Screw 1
Screw 2
Screw 3
Screw 4,5
Screw 6
Allen key
Digitech ENU rev. Feb 2011
MENU S ELECTIO NS
Measured trees s
ent with
IR- or radio­signals
Measured trees are stored in the internal memory
Delete trees and memory
Show (Inspect) measured trees
Transfer measured trees to PC with IR or Radio
Set random generator for sample tree signal
Set 1-key or 3­key function when measuring and use of IR­or Radio­transmission.
LINE
LOCAL
PC
INSP
CLR SET RAND
OFF
COPY
Transfer measured trees to Handheld with IR or Radio
Send stand table to HP Printer 2cm /2Inch classes
or by Radio to
PC
PRNT
Digitech ENU rev. Feb 2011
©Haglöf Sweden®AB Mantax Digitech - 10 -
BATTER Y
The caliper will alert the user when the battery needs to be changed by showing ‘Bat0’ in the display.
Collected data will remain in the memory also when changing the battery. The memory is of a non-volatile type and does not need any backup battery. When changing battery, the version number of your caliper firmware is shown in the display. Depending on number of previous registers, you may have to wait up to 6 seconds before you can start working with the caliper after replacing the battery.
LOCAL
Measured trees are stored in the internal memory in the Local menu.
The number of captured measurements is featured in the display for a short while. Registration of tree species and diameters can be made in two different ways, and your choice is made under SET in the menu. When delivered, the Digitech caliper is set in 3-key registration mode.
1-KEY REGISTR ATIO N (1BUT )
Press the caliper jaws around the object to measure a diameter. Select species by pressing the number as
stated below with the E-key.
1 short press for tree species 1 2 short presses for species 2 3 short presses for species 3 4 short presses for species 4 5 short presses for species 5 (or 1 fast +1 long press) 2 short presses +1 long press for species 6 3 short presses +1 long press for species 7 4 short presses +1long press for species 8
3-KEY REGISTR ATIO N
Pick species 1..8 with the arrow keys L or R. Press the jaws around the object to
measure and press E.
Tree species’d’ offer to feature the diameter in the display without registering
any value (see double scale function next side).
DOUBLE SCALE FUNCTION
1-KEY REGISTR ATIO N (1BUT )
If pressing E for a short while, the current diameter will be shown in the display but no registration will be stored. Keep pressing the E key and move the caliper jaws to zero position (0) when you temporarily wish to
V 1.6
1034
Digitech ENU rev. Feb 2011
©Haglöf Sweden®AB Mantax Digitech - 11 -
“extend” the scale length with 500mm / 18”. A larger diameter than the physical scale length can now be captured in the Digitech caliper.
1. Measure the diameter manually up to 500mm / 18” and put a mark on the tree stem.
2. Double the scale according to the above.
3. Register the remaining section standard procedure.
3-KEY REGISTR ATIO N
Choose species‘d’ and press E, keeping the key depressed. Move the caliper jaws to zero (0) and release the E button. The scale length will temporarily be expanded with 500 mm / 18” .A larger diameter can now be stored. See Double scale function above.
DEL ETE LAT EST REG ISTRATI ON
By keeping the L key pressed for a while, it is possible to delete the latest registration made. When doing this, the total number of registrations is shown in the display and the updated total number after deletion has been completed.
READIN G H EIGH TS F ROM VER TEX AND VER TEX LAS ER H EIG HT M EASURERS
Activate the reading by pressing the R key for a short while. When ’IR’ is continuously shown in the display, data can be sent from the Vertex and/or Vertex Laser instrument.
Data is transferred from the Vertex/Vertex Laser height measurer when pressing the IR key on the instrument (turn to the instruments manual for details on measuring result transmission). Repeat the process if necessary (for example if the Digitech caliper did not respond to the IR transfer).
NOTE: It is important to aim the IR exit port on the instrument towards the IR input on the Digitech to transfer data.
Digitech ENU rev. Feb 2011
©Haglöf Sweden®AB Mantax Digitech - 12 -
The IR reading can be stopped by pressing ESC on the Digitech caliper (L + R buttons).
LINE
In the LINE Menu, captured trees are transferred directly via Radio or IR without storage in the internal memory. Register tree species and diameters in the same way as in LOCAL menu. Radio or IR is set under menu SET. Data is transferred as 4 signs, where the first sign represents the species number ’1’..’8’. The other three signs represent the diameter in mm (or inches +10) and finishes with CR and LF (Carrige Return, Line Feed). The receiving serial port should be set to 1200,8,N,1. Radio-receiver DigiRadio V1.6 or IR-receiver IR6 can be used as receiving module.
Ex. 1224 [CR]+[LF] 1=species and 224 is the diameter in mms CR=carrige return character, LF=Line feed character.
Note: The caliper Id can be set in the Digitech® menu Set. If the Id is 1, 2, 3, 4, 5 or 6, an extra digit is added after the diameter digits. This makes it possible for a receiving unit (handheld computer) to separate caliper data if more than one caliper unit is operating in the field transferring online measuring results.
Ex. 12245 [CR]+[LF] when Caliper Id is set to 5.Caliper Id 0 is the default setting, no Id after diameter character.
Digitech ENU rev. Feb 2011
©Haglöf Sweden®AB Mantax Digitech - 13 -
CLR
In the CLR (CLEAR) menu, some or all registrations can be deleted. If pressing the E key for approximately 10 sec’s, all tree data is deleted. If you make a short press, only the latest registered tree will be deleted.
IN SP
Captured field data can be checked in the INSP (Inspection) menu. Use the arrow keys L and R to scroll registrations. L=go back, R=go forward. Leave the INSP mode by pressing ESC.
COPY
In the COPY menu, captured registrations can be sent to a handheld via Radio or IR. Data is sent in the following format:
;130 ‘Number of trees (0..999), modula 1000. 1123 Species and diameter, see Line 1430 -”­1435 -”-
PC
DigiCom.exe enables easy transfer of field data to PC. Captured data is exported to Excel as a tab-separated text-file or as a Stand table in 1- or 2-cm classes with the corresponding sample trees and sample plot data.
Name of tree species, method for inventory and settings for data interpretation from the Digitech can be defined in the program. Data from more than one caliper unit can be transferred and interpreted as one object. You can also choose to perform a total measurement or a circular sample plot measurement.
The DigiCom program will interpret two 0-diameters following each other (dia<5mm) as a New Sample Plot, and three 0-diameters as a New List (stand). This function enables to operator to capture and store Sample plots and Stands in the Digitech caliper in timely manner.
Tree heights are usually captured and stored under Code=8. To use, first register the tree species and diameter. Input the tree height as a diameter (dm) using code 8. Up to 3 different heights per individual object (=tree) can be registered, normally stating the total height, the height of green crown and a third, optional height.
If using the Vertex and/or Vertex laser instruments to transfer heights to the Digitech caliper, the height value will always be stored under code=8. Up to 3 different heights per registration can be captured and stored, as total height, green crown height and the third, optional height.
Digitech ENU rev. Feb 2011
©Haglöf Sweden®AB Mantax Digitech - 14 -
DIGICOM V1.0
1. Start DigiCom.exe program
2. Connect the IR4 cable to serial port and hold
the cable towards the Digitech (see image).
3. Go to the PC menu in the Digitech and
press the E-key. Hold the cable in the same
position until “PC” is displayed again in the caliper display.
If this operation is not successful, make sure that Ir has been selected in the SET menu in your Digitech caliper. If it still does not work, switch the serial port in the Settings menu, in DigiCom.
4. When data is received, a new screen will open up in the PC. Settings on how to interpret data from the Digitech can now be made.
CODE
The CODE is equal to the number that you have chosen in the Digitech when you measure a tree. This number is normally equal to the tree species. Heights are (normally) registered as Code=8. If using the Vertex and/or Vertex Laser height measuring instrument for height input, the height value will always be stored as Code 8. Up to three different heights per each register can be captured and stored as total height, green crown height and a third, optional height.
Digitech ENU rev. Feb 2011
©Haglöf Sweden®AB Mantax Digitech - 15 -
NA ME O F TREE SPECIES
To change name of tree species, click ”Tree species”
EDIT D ATA
Input data can be edited, changed, deleted or added in this menu.
DEL ETE 0-D IAMETER S
If certain 0-diameters that are not required have been input, they can be ignored and deleted here.
TWO 0- DIAM ETERS=N EW PLOT
Choose this if performing a circular sample plot measuring method.
THREE 0-DIAME TERS =NEW LI ST, STA ND
Choose this option if you have several stands registered in one caliper unit.
<<Back
Choose this option if you wish to read data from more than one caliper unit.
Break
Choose this option if you wish to interrupt or read data from more than one caliper unit.
Forward>>
Step forward to next screen where list and export format are chosen.
Digitech ENU rev. Feb 2011
©Haglöf Sweden®AB Mantax Digitech - 16 -
EXPOR T DA TA
In the following screen sequence, the chosen list to be exported and the way it should be presented in the out­file, are picked.
1. Choose list by marking the list-number under LIST.
2. Choose export format under Export as between:
1cm Standtable
2cm Standtable
Excel txt -file
Forward>>
Step to the following screen where ID for the chosen list is set.
ID ENTI TIE S
Choose stand- and partial stand-names.
RADIUS
If having made a circular sample plot measurement, the radius- or area size can be set here.
Forward>>
Continue and go further to store and name the result file. The standtables will automatically open up in a file editor, while the tab-separated excel-file is manually opened by the user (as a txt-file).
Digitech ENU rev. Feb 2011
©Haglöf Sweden®AB Mantax Digitech - 17 -
RESULT EXAMPLE ST ANDTABL E
C:\test.txt 2002-02-13 07:34:33 LIST 1 STAND TestStand 1 PART OF STAND part 2 TYPE OF INVENTORY PLOT INVENTORY Number of plots 2 Number of trees 11 Number of sample trees 1 PLOT AREA m2 154 AREALFACTOR 32.5
SAMPLETRE DIA mm HEIGTH dm HEIGTH2 dm HEIGTH3 dm 1 Pine 335 208
PLOT BA m2/ha NUM/ha 1 38.9 195 2 36.7 162
STANDTABLE CLASS CM Pine Spruce Birch Other Co Other Oak Beech TOT 10-12 1 1 14-16 1 1 18-20 1 1 20-22 2 2 22-24 1 1 24-26 1 1 28-30 1 1 32-34 1 1 36-38 2 2 SUM 11 11 Aver.Dia 24.7 24.7 Aver2Dia 26.0 26.0 Aver3Dia 29.6 29.6 A.Heigth 20.8 20.8
EXPLAN ATIONS
Area factor Quotient of 1ha and total sample area BA Basal area m2/ha Aver.Dia Average diameter sum dia/n Aver2Dia Average dia*dia sqrt(sum(dia*dia)/n) Aver3Dia Average dia*dia*dia sum (dia*dia*dia)/sum(dia*dia) A.Heigth Average heigth sum h/n (sampletree)
Digitech ENU rev. Feb 2011
©Haglöf Sweden®AB Mantax Digitech - 18 -
EXAMPL E TA B SEPAR ATED EX CEL TXT FIL E
LIST STAND PARTOFSTAND PLOT PLOTAREAm2 SPECIE DIA mm HEIGTHdm HEIGTH2 HEIGTH3
1 1 TestStand 1 part 2 1 154 Pine 157
2 1 TestStand 1 part 2 1 154 Pine 244
3 1 TestStand 1 part 2 1 154 Pine 335 208
4 1 TestStand 1 part 2 1 154 Pine 118
5 1 TestStand 1 part 2 1 154 Pine 201
6 1 TestStand 1 part 2 2 154 Pine 362
7 1 TestStand 1 part 2 2 154 Pine 236
8 1 TestStand 1 part 2 2 154 Pine 290
9 1 TestStand 1 part 2 2 154 Pine 374
10 1 TestStand 1 part 2 2 154 Pine 218
11 1 TestStand 1 part 2 2 154 Pine 181
Digitech ENU rev. Feb 2011
©Haglöf Sweden®AB Mantax Digitech - 19 -
DATA F ILE FRO M THE C ALIP ER
Data from the Digitech caliper can be stored as a dig-file. This file can be opened later on if you wish to delay export of data.
A register in the dig-file will be stored as a four (4) digits string where the first digit signifies code as ´1`… ´8`and the three remaining digits show the tree diameter in mm.
For example: 11232345 1st register: Code 1, 123mm 2nd register: Code 2, 345mm
LINE
Data from the Digitech® can be transferred online to DigiCom. Choose LINE in the Digitech menu and Line in the DigiCom. Data from the current registration will be received by the connected radio receiver and stored by the DigiCom. By clicking in the field below CODE or VALUE you can make changes in the last registration. Delete is easiest made in “Delete last”. Choose OK after finishing the measuring and to start exporting data.
Digitech ENU rev. Feb 2011
©Haglöf Sweden®AB Mantax Digitech - 20 -
PRINT
In this menu, data can be sent as a standtable to a HP-printer.
MANTAX DIGITECH D * #1 #2 #3 #4 * #5 #6 #7 #8 TOT 0* 5 - - ­ * 1 - - - 6
2* 2 - - ­ * - - - - 2 4* 15 - - ­ * - - - - 15 6* 7 - - ­ * - - - - 7 8* 8 - - ­ * - - - - 8 10* 6 - - ­ * 1 - - - 7 12* 5 1 - ­ * - - - - 6 14* 23 1 - ­ * - - - - 24 . . . 76* 1 - - ­ * - - - - 1 82* 1 - - ­ * - - - - 1 86* 1 - - ­ * - - - - 1 TOT 188 14 3 ­ *** 5 - - 1 211
RAND
In the RAND menu (- random), parameters for sample tree registrations can be set. The form factor used in the sample tree generator is: K x d2/D2
K (quote %) between 0 and 99 d Captured diameter D Mean diameter of tree specie
If the number is larger than the random number between 0 and 99 a loud beep will go off 10 times, indicating the registration of a sample tree. The parameters D and K can be named separately for tree species 1,2 and 3. For other species D and K are normally named.
Digitech ENU rev. Feb 2011
©Haglöf Sweden®AB Mantax Digitech - 21 -
The parameters are shown and can be changed as follows:
Choose RAND menu and tree species 1 to 4 with the L or R key. Press E. The D value for the current tree species is now featured in the display. By giving a short press on the E key, you step forward to the K value. Another short press and you return to the chosen tree species.
If a value needs to be changed, press the key for a short while and move the caliper jaw until desired value is featured in the display. Tree species with a K-value 00 will not be marked as sample trees.
SE T
One- or more key function is set in this menu, and Radio- or IR-transfer.First select between 1but (one-key function) or 3but (3-key function). Use the arrow keys L and R to choose 1but or 3but, activate your choice with the E-key.
1but Choose species and register diameter with the E-key.
3but Choose species with L and R keys and register diameter the E-key.
Then select Radio- or IR- transfer. This selection has to be made depending on what receiver you intend to use when sending captured data.
Rdio: Radio transfer Ir: Infra red transfer
Digitech ENU rev. Feb 2011
©Haglöf Sweden®AB Mantax Digitech - 22 -
RADIO
The Digitech has a built in radio transmitter, enabling wireless data transfer up to 25m/82feet with an external antenna, without antenna, up to5m/16feet.
The antenna is mounted at the back of the Digitech caliper. Remove the cover before mounting the antenna.
Data can be sent online when the user presses Enter, see Line. Data can also be sent as a file, including all stored registration, see PC. Make sure to set the caliper in Radio mode when using the Radio. Choose Rdio instead of IR in the SET menu. The receiver can be used in any PC compatible 9 pin serial port.
Receiver for other types of interfaces can be ordered from Haglöf Sweden AB.
ANTENNA
DIGIRADIO
Digitech ENU rev. Feb 2011
©Haglöf Sweden®AB Mantax Digitech - 23 -
TECHNICAL SPE CIFI CATION
Length 50cm/65cm/80cm 18”/24”/30” Memory 8000 registers Processor Low power 32 bit arm based processor Measuring system Electronic, non-contact Jaws Detachable aluminium No of tree species 8ea (1..8) Measuring range 0..999mm / 0..36” (when using the ’double scale’ function) Battery 1ea 1.5V AA battery Communication IR and radio Power 20mW Weight 600g (scale 500 mm) Temperature range -20…+60 C Signal Built-in loud speaker Tests IP67 moist + dust proof. See Declaration of conformity
Digitech radio: UHF transceiver 433.92MHz ISM (Industrial, Scientific and Medical) frequency band, in compliance with the European Telecommunication Standard Institute specification EN 300 220-1 V1.2.1. Theoretical power output 10mW. Power output dependies: Antenna length 125mm 55mm 30mm No antenna E(mV/m)@3m <20 <6 <2.5 <1.4 Antenna 125mm can be used in EU countries Antenna 30mm can be used in US , FCC Regulation Part 15, Section 231
AC CESSORIES
IR 4
IR-receiver for PC
IR 6
IR-receiver for Handheld
DIGIRA DIO V1. 6
Radio-receiver for PC or Handheld
DIGIANTENN
Radioantenna for DigiTech.
Digitech ENU rev. Feb 2011
©Haglöf Sweden®AB Mantax Digitech - 24 -
DECLAR ATION OF CONFORMIT Y
According to the EMC Directive 89/336/EEG, 92/31/EEG & the Low Voltage Directive 73/23/EEG and 93/68/EEG including amendments by the CE-marking Directive 93/68/EEGType of equipment Caliper. Brand name or trade mark Haglöf Sweden®, Digitech. Type designation(s)/Model no(s) Digitech & DigiRadio. Manufacturer’s name, address, telephone & fax no Haglöf Sweden AB, Klockargatan 8, SE­882 21 Långsele, Sweden Tel: + 46 620-25585, Fax: + 46 620-20581 The following standards and/or technical specifications, which comply with good engineering practice in safety matters in force within the EEA, have been applied: Testreport/ technical construction file/ normative document. Ref. No: 02012 Standard EN 50081-1, EN 55011 Class B EN 50082-2, EN 61000-4-2, -3 Level 3. FPA prüfnummer 3595, Kwf nr 1.06.3595. The product is CE-marked. As manufacturer/ the manufacturer’s authorized representative established within EEA,we declare under our sole responsibility that the equipment follows the provisions of the Directives stated above.
WAR RANT Y AN D SE RV IC E INF OR MA TI ON
Haglöf Sweden AB warrants that this product shall be free from defects in materials and workmanship, under normal intended use, for a period of 12 months after date of shipment. The warranty excludes the batteries, the accessories and any written materials. The warranty does not apply if the product has been improperly installed, improperly calibrated or operated in a manner not in accordance with the user’s guide. Warranty is also automatically expired if the product has been opposed to external force and warranty is not applicable for cosmetic defects. The one-year limited warranty time covers obvious fabrication defects. Defects in the electronic components that are impossible for the manufacturer to detect prior to assembling and shipping of the product may occur. Haglöf Sweden AB can in no case be responsible for problems of this nature and has no liability for any loss of business, profits, savings, consequential damages or other damages resulting from use of the products described. Signs of misuse, cosmetic damage, accidents or equal automatically withdraw the warranty. The warranty is valid in the country where your Haglöf product has been purchased. A product covered by warranty will be object to exchange, service, and repair or according to special agreement between seller and buyer, within the frames of the limited warranty. Haglöf Sweden reserves the right to determine which option will be most suitable for each separate case after having examined and evaluated the product.
IM PORTANT ISSUES:
For a valid warranty, a copy of invoice or dated receipt of your purchase must be presented. The serial number of
the returned product has to be clearly stated upon return. Go to
http://www.haglofsweden.com/PDF/HaglofRMA.pdf for return form/turn to your supplier for assistance.
The return freight to us is on buyer’s expense. After warranty repair or exchange, the return freight to you is on
our expense. If warranty has expired or is null and void, all freights are on buyer’s expense.
If no original invoice can be presented upon shipment, or if two years or more have passed from date of
purchase, a customs fee will be added by the applicable customs authorities and possibly in receiving country as well. These fees are on buyers account.
We perform repair and service of products where warranty has expired when possible. Cost estimation will be
sent to you after evaluating the returned product for cost approval. Please also see above paragraph on customs fees.
Please do not hesitate to contact us or any Haglöf Sweden AB representative for questions or comments! Any signs of misuse or negligence automatically withdraw our warranty commitments
SOF TWAR E
© Copyrights of Haglöf Sweden AB Software belong to Haglöf Sweden AB. Unauthorized duplication is prohibited. Haglöf Sweden and DIGITECH are registered trademarks of Haglöf Sweden AB. Production is made in Sweden.
Haglöf Sweden and its suppliers cannot warrant the performance or results when using the firmware, software or hardware, nor the documentation. No warranties or conditions are made; neither expressed nor implied, of merchantability, suitability or special fitness for any particular purpose. If software problems appear, please contact your programmer for support. Haglöf Sweden takes no responsibility for loss of income, time, or problems and delays due to problems in soft- or hardware of products. *Copyrights of all software & firmware made by Haglöf Sweden belong to Haglöf Sweden* Any lists and/or information of software for any Haglöf Sweden AB products should be considered as brief descriptions and not as a complete guide to what may and may not be available. For further details, please see ORGALIME SW01, General Conditions for Computer Software, and Supplement to ORGALIME S 2000 or ORGALIME SE 94.
Loading...