The IP66 range is manufactured from tough, durable
thermoplastic, and is intended for use in an outdoor
environment, or one in which the protection provided
by the IP66 range is required.
All of the products are rated IP66, for protection
against water and dust. All IP66 products need to
be tted with waterproof cable or conduit entries to
maintain their IP rating once installed.
The IP66 range complies with the following standards
Socket outlets: BS1363-2 / SS145 (13A); BS546
/ SS472 (15A); Fuse connection units: BS1363-4;
Switches: BSEN60669-1 / IEC60669-1.
2

All products in the range comply with the low voltage
directive LV 72/23/EEC and where relevant EMC
directive 89/336/EEC
Advice should be sought before installing this product
in an environment where it is likely to be subjected to
chemicals, oils, solvents or wood preservers
Installation Instructions
These products should be installed by a competent
person (eg. qualied electrician) in accordance
with these instructions and in compliance with the
appropriate clauses of the current edition of the IET or
IEC wiring and building regulations. Sockets should
be protected by a suitable RCD device.
The IP66 range is designed to be mounted on a
vertical at surface, with socket outlets not more than
1.5 meters above the ground.
3

The rear box shall be mounted on the wall using four
number 8 wood screws.
If conduit is to be used then please follow the
instructions below:
The drain feature can be drilled out using a 5mm drill
if top or side entry conduit is used. Opening this drain
hole will reduce the IP rating of the product.
If bottom entry conduit is used, there must be
adequate drainage from the lowest point of conduit.
The relevant cable entry knockout should be carefully
removed.
The rear box is equipped with 20mm removable
blanks, if a 25mm entry is required the blank should
be left in place and drilled out using a suitable 25mm
hole saw. The centre position of the blank has been
pre marked for this purpose.
4

A waterproof cable or conduit entry must then be
tted in its place.
If two cable entry positions are used with metal
conduit, then earth continuity between the conduits
must be maintained.
Ensure that the gasket is correctly tted, and tighten
the four screws to x the front cover in place. Do not
over tighten. Use of an electric screwdriver is not
recommended.
5

Operating Instructions for the end user
The switch face should be kept free of dirt or debris.
The product should not be subjected to chemicals,
oils, solvents or wood preservers.
Cleaning
Care should be taken when cleaning this product.
The outside can be cleaned with a mild detergent.
Solvent based cleaners should not be used.