Prepare the supply voltage
Respective connection cables should be provided for the power supply of the
device.
The Windows versions must be connected to a power supply 24 V DC (see
accessories).
The Android versions have a limited PoE capability. When selecting the supply
voltage, the intended use must be considered.
A 24 V DC auxiliary voltage is available when
- the device is integrated into a door communication system (Elcom)
- Audio-les are played-back (music, internet-radio)
- no PoE-supply (Power over Ethernet) is available)
Ongoing exceeding of the permissible PoE-power consumption, from
increased use of the audio applications may lead to the PoE power supply
switching off.
Installing connector (RJ45) on the network cable (gure 11)
The ush-mounted housing is installed rmly in the wall. The empty conduit
with the network cable is guided through an entry on the housing.
z Insert the network cable through the metal cap's earthing cover of the
connector.
z Strip the Ethernet strands of the network cable, do not remove insulation.
z Insert the strands into the plug-in connector (19) of the connector and bend
up 90°. Shorten any protruding strands.
When doing so, it is imperative to observe the colour code EIA/TIA -568 A
or B of the system. This can be found in the documentation of the installed
network components and routers. The Ethernet connection has been con-
nected to the device compatible with wired networks in accordance with
TIA/EIA-568-A or B
z Insert the plug-in connector into the connector (20) and snap it shut.
The plug-in connector is locked in place in the connector.
z Tighten the enclosed cable tie over the earthing cover.
P