hager tre50 series, tre52 series User Instructions

1 6T 7972-02b
6T 7972-02.b
TRE50., TRE52.
§
220° Motion Detectors
User instructions
¨
230V~
Bus
30 V
V2.5.1
ACCESSORY FOR
ANGLE FIXING EE855 White EE856 Anthracite 52125 White 52126 Anthracite
220° DETECTORS TRE500 White TRE501 Anthracite TRE520 White TRE521 Anthracite
15 min
s
5 min
auto
-
+
lux
test
30
α
IP55
+ 90°/- 30°
+/-80°
Description
Detection zone
Installation
Wall fixing plate
Adjustment potentiometers
Directional detection head
Adjustments
Shutters
Angle fixing support
Vertical adjustment
Optimal installation height is 2.5m. The detection zone shall remain free of obstacle.
8 m 16 m
2,5 m
0,5 m
16 m
4 m
LED A LED B
Delay (lighting time)
Brightness
level
Sensitivity (change of range)
1
2
2 6T 7972-02b
Warning :
This device is to be installed only by a professional electrician fitter according to local applicable installation standards.
Test and validation of detection zone
Set potentiometer 2to Test mode. The Test mode is available for 3 minutes time and does not take brightness level into account. Each detected movement turns LED A on for 2 seconds. The associated receiver is not under control. After 3 minutes without detection, the product is set back to auto mode. Limitation of detection zone: You can limit the detection zone using the shutters supplied or by inclining the head.
Mounting
Projection or ceiling mount :
- Fix the wall plate using the supplied screws.
- Clip the detector onto the wall plate
- Tighten the screws to close. For angle mounting, the wall fixing plate is
fitted between the accessory and the detector.
Precautions for installation
For optimum detection conditions, please follow these recommendations :
- Keep the detector protected from solar radiation and bad weather, as it is sensitive to these conditions.
- Maintain 1m distance between the light source and the detector and keep the detector out of the light source.
Product Description and working principles
This detector allows remote control of one or more receivers for a given time when a movement is detected in its detection zone. This product can be used in two types of configuration: one detector controls one/several receiver(s); several transmitters control the receiver(s).
Operation
The receiver(s) is(are) under control as soon as the brightness level as set by potentiometer
2
is considered too low and a movement is detected. Upon detection, the time delay is restarted.
If LED A flashes quickly during configuration, the position of potentiometer
1
is not compa-
tible with the selected function. If LED B flashes quickly or nothing occurs
when starting configuration, check that the batteries are correctly installed and replace them if necessary. Product factory reset is recommended before any new configuration.
Factory return
Keep push-button J depressed until LED cfg (flashes (>10s), and then release it. LED cfg is turned off when factory return is completed. This operation causes full delete of product configuration in any configuration mode. After factory return, wait 15s before starting.
Action Adjustments Potentiometer
Use Auto (factory) settings to set automatic lighting turn-on for a given time. Only available when a detector’s time delay is set.
Auto Settings
Put the Lux potentiometer on “auto test”. The settings are predefined :
Lux = , (operating at night only) time = 3 min, sensitivity = max
auto
lux
test
Turn automatic lighting on for a given time. Only available when a detector’s time delay is set.
Installer settings
15 min
30 s
5 min
auto
-
+
lux
test
Test and confirm detection zone.
Test mode
Move the potentiometer
2
to “auto test”.
auto
lux
test
auto
lux
test
Adjust sensitivity. Allows setting the range
to avoid disturbance.
-
+
Hereby, hager Controls, declares that this motion detector output is in compliance with the essential requirements and other relevant provisions of Directive 1999/5/EC.
The CE declaration can be consulted on the site :
www.hagergroup.net
Usable in all Europe and in Switzerland
Installing batteries
J Button
cfg
c
f
g
LED C
Button J
Configuration (button J )
These detectors can be configured in 3 different ways :
: tool-free configuration (using product pushbuttons and LEDs), see User's Instructions 6T7952 supplied with the product.
• TX100/B V2.5.0 or above: description of product functions available from the Manufacturer.
• ETS3 or via TR131: database and description of application software available from the Manufacturer.
Configuration by TX100 or ETS
Set the product in configuration mode by pressing
J button once during the teaching session of
TX100 or for addressing with TR131 in ETS.
O
Product factory return is required to change the configuration mode.
quicklink