Hager JK104BG, JK106BG, JK108B, JK124B, JK118BG User Manual

...
Invicta 3 Distribution Board User Instructions
Your property has been equipped with a hager Distribution Board. This unit and it’s associated hager protective devices will offer the highest level of protection for your premises.
A range of possible protective devices may be installed in your consumer unit, including Miniature Circuit Breakers (MCBs), Residual Current Circuit Breakers (RCCBs), or combined MCB/RCDs (RCBOs).
INV USERINV USER
MCBs and fuses are safety devices designed to operate in the event that a circuit or appliance demands too much current.
RCCBs are also safety devices but are designed to protect against fault currents owing to earth, and these reduce the risk of re and electric shock. RCBOs combine the operation of both the MCB and RCCB. Access to the devices is by lifting the tinted door.
T
RCCBs and RCBOs should be tested every 3 months. Press the TEST or T button. The device should trip (go to the OFF position). If it trips, reset the device by pushing the toggle to the up (ON) position. If it does not trip call a qualied electrician.
ONLY QUALIFIED ELECTRICIANS SHOULD REMOVE THE FRONT COVER.
If any of the protective devices have tripped please follow the ow diagram below.
IF IN DOUBT ALWAYS CONSULT A QUALIFIED ELECTRICIAN.
HAGER TECHNICAL SUPPORT HELPLINE: 01952 675689.
T
ON ON ON
ON
RCCBBlank RCBO
(2 Module)
* Important note Fuse carriers must not be opened or closed with the main
Use circuit as
normal
Call an
electrician
switch in the ON position.
YES
Does device
NO
Does device
supply socket
Unplug all appliances from circuit and reset device / replace fuse*
stay ON?
NO
outlets
YES
Try & reset device once
Tu rn ON
Main switch
T
MCB
or
RCBO
Pull down fuse* carrier handle and replace blown fuse with equivalent type & rating, close carrier
MCB Switch
RCBO
(1 Mod)
START
MCB/Fuse
tripped
Fuse
RCCB
Try & reset device once
Call an
electrician
NO
What device
is it?
Tu rn OFF
Main switch
Use circuit as
normal
YES
Does device
stay ON?
NO
Tu rn OFF
all MCBs / fuse*
devices
Reset RCCB
Does device
stay ON?
appliance until
repaired. Reset device.
Other appliances may
be used
Tu rn ON MCBs / fuses* devices one at a time until RCCB trips again, identifying faulty circuit
NO
Does device
stay ON?
Plug in & switch on
YES
appliances one at a time until device trips / blows, identifying faulty appliance
Hager Ltd. Hortonwood 50 Telford Shropshire TF1 7FT • Sales Hotline: 01952 675612 • Technical Helpline: 01952 675689