hager I-EA00116 Installation Instructions Manual

433 MHz Transmitters & Reciever
433 MHz Transmitters & Reciever
Installation Instructions
Installation Instructions
Digital Transmitters and Receiver with Sequencing Function
Digital Transmitters and Receiver with Sequencing Function
I-EA00116
I-EA00116
1 Description
Since receivers can be individually programmed, multiple receivers can be programmed differently thus allowing for sequencing in multiple applications. Upon activation (pushplate / transmitter), all receivers will acquire the signal at the same time; however, each receiver will respond according to their programming. Those receivers programmed with NO DELAY will active immediately upon receiving the transmitter signal. Those receivers programmed with a DELAY will activate at the end of their pre-determined time delay set by the potentiometer. The use of multiple receivers will allow for the uninterrupted pace or hands free operations through a pair of doors upon initial activation.
2-659-0186
ONE BUTTON
2-659-0184
3V w / LEADS
2 Specifications
DESCRIPTION SPECIFICATION
FREQUENCY 433 MHz
EMITTED RADIO POWER -28.7 dBm (Transmitter)
POWER CONSUMPTION 3mA (Transmitter) 30mA (Receiver)
INPUT VOLTAGE 12 to 24 VAC/DC (Receiver)
CONTACT RATING 1.0 A @ 30 VDC / 0.3 A @ 60 VDC
OPERATING TEMPERATURE 14ºF TO 131ºF (-10ºC TO 55ºC)
MAX No. OF PROGRAMMED UNITS PER RECEIVER
LEDs Receiver Learn
Relay Activation
DIMENSIONS Transmitter
Receiver
CERTIFICATIONS FCC, IC,
0.5 A @ 125 VAC
100 TRANSMITTERS
RED BLUE
2 3/4” X 1 3/8” X 9/16” (70mm x 35mm x 14mm) 2 3/4” x 2 1/8” x 1” (70mm x 55mm x 25mm)
3 Precautions
2-659-0183
TERMINAL
STRIP
2-659-0185
9V w / LEADS
DIP
SWITCH
LEARN WITH
DELAY BUTTON
ANTENNA WIRE
BLUE LED
RED LED
LEARN W/O DELAY BUTTON
DELAY POTENTIOMETER (Time Adjustment)
q
This product IS NOT intended for use with Maglocks / Electric Strikes. Contact Hager Companies for further information.
q
Shut off all power going to work area before attempting any wiring procedures.
q
Maintain a clean & safe environment when working in public areas.
q
To remain in compliance with Part 15.231, do not operate transmitter (hold down button ) for longer than 5 seconds.
q
Constantly be aware of pedestrian traffic around the area.
q
Always stop pedestrian traffic through the doorway when performing tests that may result in unexpected- reactions by the door
q
ESD: Circuit boards are vulnerable to damage by electrostatic discharge. Before handling ensure you dissipate your body’s charge.
q
Always check placement of components before powering up so that moving parts will not catch any wires or cause damage to equipment.
q
Ensure compliance with all applicable safety standards (i.e. ANSI A156.10 / 19) upon completion of installation.
q
DO NOT attempt any internal repair of the components. All repairs and/or component replacements must be performed by Hager Companies. Unauthorized disassembly or repair:
1. May jeopardize personal safety and may expose one to the risk of electrical shock.
2. May adversely affect the safe and reliable performance of the product resulting in a voided warranty.
07/24/2013 Hager Companies • 139 Victor Street • St. Louis, MO 63104 • 800 325 5559 • www.hagerco.com Page 1 of 4
.
4 Programming
1 DIP SWITCH SETTINGS
433 MHz Transmitters & Reciever
433 MHz Transmitters & Reciever
Installation Instructions
Installation Instructions
Digital Transmitters and Receiver with Sequencing Function
Digital Transmitters and Receiver with Sequencing Function
I-EA00116
I-EA00116
# 1 DESCRIPTION FUNCTION
OFF Pulse Relay Press the transmitter once and the relay will be active momentarily.
ON Toggle Relay Press the transmitter once and the relay output is active indefinitely,
press it again and the relay will de-energize indefinitely.
# 2 DESCRIPTION FUNCTION (Pulse Mode Only)
OFF 0.5 sec Hold Time Relay will remain active 0.5 second after the loss of activation.
ON 10 sec Hold Time Relay will remain active 10 seconds after the loss of activation.
ON
1 2
PUL TOG
In Toggle Setting (1-ON), the Hold Time
is inactive. Either setting for #2 dip
switch will have the same result.
1 2
PUL TOG
0.5 second
Pulse Setting
0.5s l 10s
ON
0.5s l 10s
ON
1 2
PUL TOG
ON
1 2
PUL TOG
10 second
Pulse Setting
2 HAND HELD CONFIGURATION
1. Set dip switches on the receiver to the desired activation cycle (dip switch 1 -Toggle or Pulse and dip switch 2 - 0.5s or 10s hold).
2. Press either Learn w/Delay Button or Learn w/No Delay Button on the receiver depending on the activation requirements (If delay learn is selected, adjust potentiometer to counterclockwise limit, 0 second delay). After learn cycle is complete, adjust potentiometer to desired delay time (0-30 sec).
3. Depress transmitter button repeatedly until Blue LED on the receiver illuminates (indicating reception of signal from transmitter).
NOTE: Repeat Steps 2-3 to program additional transmitters.
4. To test the system, depress transmitter button (Red LED on Transmitter will illuminate) and observe that the Blue LED illuminates on the receiver. This indicates that the relay has been activated.
3 PUSH PLATE CONFIGURATION
1. Before beginning, it is easiest to have already prepared the installation of the push plate.
2. Connect the wires from the transmitter to the NO and COM contacts of the push plates switch.
3. Follow Steps 1-4 (Hand-Held Configuration); depress the pushplate to activate the transmitter.
4. Attach the transmitter to the inside of the electrical box and complete the installation.
0.5s l 10s
0.5s l 10s
4 TYPICAL VESTIBULE APPLICATION
A OUTSIDE TRANSMITTER (PUSH PLATE)
1. Press Learn w/NO DELAY BUTTON on OUTER Receiver then press Transmitter 1.
2. Press Learn w/DELAY BUTTON on INNER Receiver then press Transmitter 1.
NOTE
: Set Potentiometer to desired Delay Time per Hand Held Configuration Step #2.
B INSIDE TRANSMITTER (PUSH PLATE)
1. Press Learn w/NO DELAY BUTTON on INNER Receiver then press Transmitter 2.
2. Press Learn w/DELAY BUTTON on OUTER Receiver then press Transmitter 2.
NOTE
: Set Potentiometer to desired Delay Time per Hand Held Configuration Step #2.
C VESTIBULE TRANSMITTERS (Dual Switch Push plate or Two Separate Push plates)
1. Press Learn w/NO DELAY BUTTON on INNER Receiver then press Transmitter 3.
2. Press Learn w/NO DELAY BUTTON on OUTER Receiver then press Transmitter 4.
INNER RECEIVER
2
3
4
5 REMOVING TRANSMITTER CODE(S)
SINGLE TRANSMITTER CODE
1. Press both DELAY and NO DELAY BUTTONS simultaneously until Red LED flashes once (approximately 1 second).
2. Press transmitter button twice within 10 seconds and the transmitter code will be deleted.
ALL TRANSMITTER CODES
1. Press and hold both DELAY and NO DELAY BUTTONS simultaneously until Blue LED illuminates then release (approximately 10 seconds).
OUTER RECEIVER
1
07/24/2013 Hager Companies • 139 Victor Street • St. Louis, MO 63104 • 800 325 5559 • www.hagerco.com Page 2 of 4
Loading...
+ 2 hidden pages