hager EG 270 User Instructions

res
7
6
on
off
5
4
3
2
1
ON
ON
OFF OFF
A B
auto manu
EG 270
Working principle :
The EG 270 is a time switch for the automatic control of electrical loads. It is fully programmable with a maximum of 20 program steps to be divided bet­ween the two channels. Each program step can be applied to one or several days, maximising the use of each memo­ry location. The front cover is sealable preventing unauthorised access after completion of programming.
Warning : at the beginning of use, please reset the device in order to clear the memory before programming. This is achieved by using a pen to push the reset button.
Presentation :
Display :
time
circuit status of channel A (ON or OFF)
circuit status of channel B (ON or OFF)
day of the week
(1 = Monday, 2 = Tuesday ....)
Buttons :
Mode selector : to select one of the following modes :
time setting
A programming channel A B programming channel B auto running mode manu manual override
1” to “7” : selection of the days
on/off” : chooses whether the circuit is on or off
+” and “-” : changes settings
enter” : to confirm
reset
Time and day setting :
1. Move mode selector to
2. Select with key 1 to 7 , the actual day (1=Monday, 2 = Tuesday .)
3. Input time with buttons + and “-”.
Important :
The clock starts when exiting the time setting mode.
Programming channel A :
1. Move mode selector to A”.
2. Select with keys 1 to 7 the day(s) assigned to this program step. An arrow appears above each day concerned.
3. Input switching time with buttons + and “-”.
4. Input the type of switching with button on/off (for the first action ON is automatically proposed).
5. Enter this program step with button enter”.
Program additional time settings by repeating steps 2 to 5.
Important :
To activate the program, move mode selector to
auto.
Programming channel B :
Move mode selector to B”. Same way of programming as channel A.
Important : To active the program, move mode selector to “auto.
Running Auto mode
This mode is the current displaying mode. It does not allow any modification.
Move mode selector to auto”. Display of the time, the day and the state of the two channels.
To check your program on channel A or B :
1. Move mode selector to A or B”.
2. Press the enter key repeatedly to display the different program steps (switching time, days of the week and state of the channel ON or OFF).
To override the output :
Important : the override must be identical on the
two channels (channels A and B ON”“ON or channels A and B OFF”“OFF).
Permanent override :
1. Move mode selector to manu”.
2. Select the state of the outputs with key on/off”.
To switch back to automatic mode, move mode selector to auto”.
1234567
1
2
4
3
5
6
78 9
10
enter
reset
on
off
A B
auto
manu
ON ON
1234567
enter
reset
on
off
A B
auto
manu
To modify or delete a program step on channel A or B :
1. Move mode selector to A or B”.
2. Press enterrepeatedly and select the program step to modify or to delete.
3. Modify :
- switching time with keys +” or “-”
- days assigned with keys 1 to 7”.
(an arrow flashes above all days assigned, press once to add a day, press twice to cancel).
- state of the channel with key on/off”.
To delete a program step, press keys 1 to 7 in order to cancel all days assigned.
4. Confirm with the enter key.
2 channels time switch ­weekly cycle
1234567
enter
reset
on
off
A B
auto
manu
ON ON
1234567
enter
reset
on
off
ON ON
A B
auto
manu
1234567
enter
reset
on
off
A B
auto
manu
ON ON
User instruction
GB
345621
L N
EG 270
987
10 11 12
A
B
Technical specifications :
Electrical characteristics :
- supply voltage : 230V +10/-15% 50Hz
- outputs : 2 changeover contact µ 16A - 250V AC1. µ 3A - 250V cos = 0,6 1000 W incandescent lighting
- power consumption : 1 VA
- protection degree : IP20
- insulation class : II
Functional characteristics :
- accuracy : ± 1sec. / day at 20 °C
- operating reserve : lithium battery,
total of three years.
Environment : Operating temperature : -10 to +50 °C Storage temperature : -10 to +50 °C
Connection tunnel terminals : flexible : 0,5 to 2.5 mm
2
rigid : 0,5 to 4 mm
2
Dimensions : 3 modules (3x17,5mm)
Electrical connections :
1. Move mode selector to manu”.
2. Select the state of the outputs with key on/off”.
3. Input with key +” and “-” the override duration : from 1 to 23 hours by steps of 1 hour. Then from 1 to 27 days by steps of 1 day.
4. Move mode selector to auto”. The state indication is flashing. This means a timed
override. Return to the initial program after the duration.
To reset the time switch :
Press reset to clear the program.
1. Move mode selector to manu”.
2. Press key “-” or “+” until display -h.
3. Move mode selector to auto to switch back to automatic mode.
Timed override :
To cancel the timed override :
1234567
enter
reset
on
off
A B
auto
manu
ON ON
1234567
enter
reset
on
off
A B
auto
manu
ON ON
A warranty period of 24 months is offered on hager products, from date of manufacture, relating to any material of manu­facturing defect. If any product is found to be defective it must be returned via the installer and supplier (wholesaler). The warranty is withdrawn if :
- after inspection by hager quality control dept the device is found to have been installed in a manner which is contrary to IEE wiring regulations and accepted practice within the industry at the time of installation.
- the procedure for the return of goods has not been followed. Explanation of defect must be included when returning goods.
Warranty
GB
6E 6128.b