hager EG110 Instructions For Use Manual

1 6E 6129.c
6E 6129.c
on
off
ON
OFF
enter
prog auto manu
EG110
§
1 channel time switch ­daily cycle.
User instruction
EG110
345621
L N
Technical specifications :
Electrical characteristics :
- supply voltage : 230V +10/-15% 50Hz
- output : 1 changeover contact μ 16A - 250V AC1. μ 3A - 250V cos φ = 0,6 1000 W incandescent lighting
- power consumption : 1 VA
- protection degree : IP20
- insulation class : II
Functional characteristics :
- accuracy : ± 1sec. / day at 20 °C
- operating reserve : lithium battery,
total of three years.
Environment :
Operating temperature : -10 to +50 °C Storage temperature : -10 to +50 °C
Connection tunnel terminals :
flexible : 0,5 to 2.5 mm
2
rigid : 0,5 to 4 mm
2
Dimensions : 3 modules (3x17,5mm)
Electrical connections :
1. Move mode selector to “manu”.
2. Select the state of the output with key
on/off”.
3. Input with key “+” and “-” the override
duration : from 1 to 23 hours by steps of 1 hour. Then from 1 to 27 days by steps of 1 day.
4. Move mode selector to “auto”. The state indication is flashing. This means a
timed override. Return to the initial program after the duration.
To reset the time switch :
Press “reset“ to clear the program.
1. Move mode selector to “manu”.
2. Press key “-” or “+” until display -h.
3. Move mode selector to “auto” to switch
back to automatic mode.
Timed override :
enter
reset
on
off
prog auto manu
ON
enter
reset
on
off
prog auto manu
ON
A warranty period of 24 months is offered on hager products, from date of manufacture, relating to any material of manufac­turing defect. If any product is found to be defective it must be returned via the installer and supplier (wholesaler). The warranty is withdrawn if :
- after inspection by hager quality control dept the device is found to have been installed in a manner which is contrary to IEE wiring regulations and accepted practice within the industry at the time of installation.
- the procedure for the return of goods has not been followed. Explanation of defect must be included when returning goods.
Warranty
GB
Working principle :
The EG110 is a time switch for the automatic control of electrical loads. It is fully programmable with a maximum of 20 program steps. The front cover is sealable preventing unauthorised access after completion of programming.
Warning : at the beginning of use, please reset the device in order to clear the memory before programming. This is achieved by using a pen to push the reset button.
Presentation :
Display :
time
circuit status (ON or OFF)
Buttons :
Mode selector : to select one of the following modes :
time setting
prog programming auto running mode manu manual override
on/off” : chooses whether the circuit is on or off
+” and “-” : changes settings
enter” : to confirm
reset
Time setting :
1. Move mode selector to
2. Input time with buttons “+” and “-”.
Important :
The clock starts when leaving the time setting mode.
Programming :
1. Move mode selector to “prog”.
2. Input the switching time with buttons “+” and “-”.
3. Input the type of switching with button “on/off”
(for the first action ON is automatically proposed).
4. Enter this program step with button “enter”. Program additional time settings by repeating
steps 2 to 4.
Important :
To activate the program, move mode selector to “auto”.
Running mode Auto
This mode is the current displaying mode. It does not allow any modification.
Move mode selector to “auto”. Display of the time and the state of the channel.
To check your program :
1. Move mode selector to “prog”.
2. Press the “enter” key repeatedly to display
the different program steps (switching time and state of the channel ON or OFF).
To override the output :
Permanent override :
1. Move mode selector to “manu”.
2. Select the state of the output with key
on/off”.
To switch back to automatic mode, move mode selector to “auto”.
5
1
3
2
467
enter
reset
on
off
prog auto manu
OFF
enter
reset
on
off
prog auto manu
To modify or delete a program step :
1. Move mode selector to “prog”.
2. Press “enter” repeatedly and select the
program step to modify or to delete.
3. Modify :
-switching time with keys “+” or “-”
-state of the channel with key “on/off”.
To delete a program step, modify switching time with keys “+” and “-”, until display --:-­(between 23:59 and 00:00).
4. Confirm with the “enter” key.
enter
reset
on
off
prog auto manu
ON
enter
reset
on
off
prog auto manu
ON
enter
reset
on
off
prog auto manu
ON
To cancel the timed override :
http://waterheatertimer.org/Hagar-timers-and-manuals.html
_________________________________________________________________________
Hager SAS - 132 bld d’Europe - BP 78 - 67 212 Obernai cedex (FRANCE) - Tél. +333 88 49 50 50 - www.hagergroup.net2 6E 6129.c
6E 6129.c
EG110
345621
L N
Tekniska data:
Elektriska märkdata:
- Driftspänning: 230V +10/-15% 50Hz
- Kontaktfunktion: 1 växlade kontakter μ 16A - 250V AC1. μ 3A - 250V cos φ = 0,6 1000 W glödljus
- Egenförbrukning: 1 VA
- IP klass: IP20
- Skyddsklass: II
Funktions data:
- Driftsnoggranhet: ± 1sek /dag vid 20 °C
- Gångreserv: lithium batteri, totalt tre år.
Omgivningstemperatrer:
Driftstemperatur: -10 till +50 °C Lagringstempertur: -10 till +50 °C
Anslutningar:
Mjukledare: 0,5 till 2,5 mm
2
Enkelledare: 0,5 till 4 mm
2
Mått: 3 Moduler (3 x 17,5mm)
Elektrisk anslutning:
1. Ställ omkopplaren i läge “manu”.
2. Välj på/av för respektive kanal med knapp
on/off”.
3. Ställ överstyrningstiden med “+” och “-”
knappar: välj mellan 1 till 23 timmar i steg om 1 timme. Därefter väljs antal dagar 1 till 27 i steg om en dag.
4. Ställ omkopplaren i läge “auto”.
Kontakt indikeringen blinkar och visar tidsinställd överstyrning. Överstyrning frånkopplas automatiskt efter inställd tid.
1. Ställ omkopplaren i läge “manu”.
2. Tryck på “-”och “+” knappar tills -h står på
displayen.
3. Ställ omkopplaren i läge “auto” för återgång
till normaldrift.
Tidsbegränsad överstyrning:
enter
reset
on
off
prog auto manu
ON
enter
reset
on
off
prog auto manu
ON
hager lämnar 24 mån garanti från faktura datumet ; garantin gäller alla fabrikations och materialfel och gäller under förutsättning att felaktig produkt returneras tillsammans med en förklaring av felet och kopia av fakturan via ansvarig installatör och grossist ; garantin gäller ej om hagers kvalitetskontroll finner att produk­ten är i fullgot skick eller att den ej installerats enl. gällande föreskrifter.
Garanti
SE
Användning:
EG110 är ett tidur för automatisk kontroll av elektriska laster. Ett programmeringsbart tidur med max 20 pro­grammsteg , som delas upp mellan två kanaler. Frontlocket på uret är plomberbart så att ingen obehörig skall ställa om några funktioner.
Varning: Innan användning skall man återställa EG110 för att rensa minnet innan programmering. Detta görs enklast genom att använda en penna för att trycka in resetknappen.
Presentation:
Display :
Tid.
Status (på/av).
Knappar:
Läges omkopplare: för att välja ett av följande läge:
Tidsinställning
prog Programmering auto Drift läge manu Manuell styr ning
on/off”: på/av: välj om kanalen skall vara på eller av.
+” eller “-”: ändrar inställningar
enter”: för att bekräfta
reset
Realtidsinställning:
1. Ställ omkopplare i läge
2. Ställ in tid med “+” och “-”.
Viktigt: Klockan startar efter tidsinställning.
Programmering:
1. Ställ omkopplaren i läge “prog”.
2. Ställ in tid med “+” och “-”.
3. Ställ in “on/off” (på/av) med knapp på/av.
(första läget föreslås på automatiskt).
4. Gå in i detta steg genom att trycka på “enter”. Programmera fler programsteg genom att repetera
repetera steg 2 till 5.
Viktigt:
För att aktivera programmet ,ställ omkopplare i läge “auto”.
Driftläge:
Detta läge är enbart driftläge. I detta läge går inga förändringar att utföra.
Ställ omkopplaren i läge “auto”. Displayen visar tiden och inställningar på dom två kanalerna.
Programmeringskontroll:
1. Ställ omkopplaren i läge “prog”.
2. Tryck på “enter” för att se dom olika pro-
gramstegen ( tillslagstid, och om kanalen är till eller från)
Överstyrning av kontakt:
Permanent överstyrning:
1. Ställ omkopplaren i läge “manu”.
2. Välj av/på med knapp “on/off”. För återställning till drift läge, ställ omkopplaren
i läge “auto”.
5
1
3
2
467
enter
reset
on
off
prog auto manu
OFF
enter
reset
on
off
prog auto manu
För att ändra eller radera ett program-steg :
1. Ställ omkopplaren i läge “prog”.
2. Tryck på “enter” och välj det programsteg
du skall ändra eller radera.
3. Ändra:
-Ändra tid med knappar “+” och “-”
-Kontaktstatus på kanalen väljs med knapp
on/off” (på/av).
För att radera ett programmsteg, ända oms­lagstid med knapp “+” och “-”, tills displayen visar --:-- (mellan 23:59 och 00:00)
4. Bekräfta genom att tryck på “enter”.
enter
reset
on
off
prog auto manu
ON
enter
reset
on
off
prog auto manu
ON
enter
reset
on
off
prog auto manu
ON
on
off
enter
ON
ON
OFFOFF
A B auto manu
EG 110
2 Kanals tidsur- dygnsur
Bruksanvisning
§
För att radera alla inställda tider:
Tryck på “reset“ för att ta bort alla program.
Hager 02.2010
Avbrytning av överstyrning:
Loading...