Hager EEK513W, EEK510B, EEK515P, EEK513P Installation Instructions

h
Y
X
Y
X
6LE000505C
EEK510B, EEK513W EEK51.P
z
PIR Occupancy Sensors
Occupancy Sensors
standalone
EEK510B
Occupancy Sensors
with pre-wired lead
EEK513W: 3 m
Occupancy Sensors
with pre-wired lead
and klik.system plug
EEK513P: 3 m EEK515P: 5 m
Description
Detection lens
LED’s for testing and IR acknowledgement
Detection areas
h 2,5 m 3 m 3,5 m
x 5 m 5 m 5 m
y 7 m 8 m 9 m
Fixing springs
IR sensor (detection)
x y
h
Overlap
Brightness measurement sensor (under the detection lens)
Potentiometers 1 and 2
auto test
1
lux
2
on
1 min
20 min
1 h
IR receiver (remote controls & programming tools)
6 m
2,5 m
The “y” values are given for lateral range. The range may be reduced if walking towards the sensor.
2,5 m
1 m
2,5 m
Settings
auto test
1
&
2
on
1 min
é
20 min
1 h
Instances of lighting levels
Position of potentiometer
auto test
1 200 Corridor
>1 ... 2 < > 200 ... 400 <
2 400 Offices
>2 ... On < > 400 ... 1000 <
On 1000 Offices
* The light measurement accuracy (Lux) is aected
by the environment (furniture, ground, walls...). If necessary, the level has to be adjusted by potentiometer or programming tool.
Lux value approximate
preset (≈ 400 Lux)
*
Application
Programming tool for settings
The installer programming tool EEK001 can be used to set the following features if the potentiometer is set on “auto test”:
- Lux levels (
- Time (
)
- Absence / presence detection
- Power up behaviour
)
-
M
- Active / passive cell .
Override remote control
The remote control EEK002 allows the switching ON or OFF of the light ( The EEK002 allows the same functionality as the wallswitch.
).
+
1 6LE000505C
auto test
1 min
1 h
20 min
1
on
2
lux
auto test
1 min
1 h
20 min
1
on
2
lux
1 min
1 h
20 min
1
on
2
lux
auto test
This device must be installed by a suitably qualified electrician according to the installa­tion’s standards.
Functional modes
The detector has 2 dierent modes.
- Presence detection (automatic).
- Absence detection (semi-automatic). The power up and cell operation can be set for each
Usable throughout Europe
Hager Controls hereby declares that the PIR Occupancy Sensorsdevice complies with the essential requirements
and other relevant provisions of Directive 2014/53/EU.
The CE declaration is available on the:
www.hagergroup.com
å
and in Switzerland
mode. A normally open retractive switch connected to the product makes it possible to reverse the lighting output state.
This state is maintained for the time period set by the potentiometer 2 or the programming tool EEK001.
Presence detection (automatic mode)
Product description and operating principles
Occupancy sensors EEK are designed to detect low level movements (e.g. person sitting at a desk). Dierent models are available:
- without lead: EEK510B for standalone and BESA mounting
- with pre-wired lead (3 m): EEK513W to be interfaced with the KLDS marshalling boxes
- with pre-wired lead (3 m or 5 m) and klik.system plug to be interfaced with the KLMB marshalling boxes: EEK513P, EEK515P.
Detection is by means of a pyroelectric sensor located under the detection lens. The occupancy sensor measures the brightness in the room on a continuous basis and compares it to the level preset on the potentiometer (or by means of the programming tool EEK001).
Settings
The Lux threshold and time out period can be set with the potentiometers or by using the installer programming tool (EEK001).
Test Mode - Walk test
This mode makes it possible to validate the detection area. To select this mode, set the potentiometer 1 to the position “auto test”. The green or red LED behind the lens is on for 2 seconds after detection. The red LED indicates that the light level measured is lower than current setting. If the green LED is on, the light level measured is higher than current setting. There is a time out of 2 minutes which is reactivated after each detection. The output is also switched during 2 s. after each detection. It is also possible to use the programming tool EEK001 to set the detector in test mode.
In this mode the light is controlled by motion in the detection area and ambient light levels.
If presence is detected whilst the light levels are below the required Lux level, the sensor is activated and keeps the light on whilst there is still occupancy and for the time out period afterwards. Once the sensor has deactivated the lights, it will require a new occupancy whilst the ambient light levels are below the required Lux levels to activate the lights again. This mode can be changed via the IR remote control EEK001 (default mode is presence detection: automatic).
Absence detection (semi automatic mode)
The sensor needs to be activated by a normally open retractive switch or a user remote control input. Once the sensor is activated, it will hold the lights on whilst there is still occupancy and for the time out period afterwards. Once the sensor has deactivated the lights, it will require another input from the wallswitch or the programming tool to switch the lights on.
Power Up
A parameter of the detector allows the choice of state for the lighting after power up (mains return). During warm up phase, the green LED blinks. In the Power up ON state, the lighting will automatically be energised when mains power is initially supplied or returned to the sensor. In the Power up OFF state, the lighting will not be energised and the sensor will not operate during warm up period. This parameter is modified using the installer programming tool EEK001.
POWER UP state:
• ON: the light is immediately switched on for 30 s
after power up. In case of detection, the light (in automatic mode) remains on during the time delay; otherwise the light is switched o.
• OFF: the detector switches to the selected mode
after warm up.
Action Settings Potentiometers
Use Auto settings (factory) or set by the programming tool to switch the light automatically for a defined time.
Automatically switch on the light for a defined time.
Test and validate the detection zone.
Auto Settings
Put the Lux potentiometer on “auto test”. The settings are predefined: Lux = 400, time = 20 min.
q: test mode for 2 min.
Programming tool settings EEK001
(manual settings inhibited).
Installer settings
Test mode
Move the potentiometer 1 to “auto test”. On this position, the programming tool
1 h
auto test
auto test
auto test
on
on
EEK001 can be used.
on
1 min
1
2
1
2
20 min
1
2
lux
lux
lux
auto test
Active / passive cell
Active cell
The photocell will inhibit the output from the sensor if the ambient light level is sucient.
If the sensor detects occupancy whilst the ambient light level is below the required Lux level, the lights will be activated. However if the ambient light level increases to a value where it is above the required Lux level during a certain time, the sensor will detect it and switch o the light.
Passive cell
The photocell will inhibit the output from the sensor if at the time of detection the ambient light level is sucient. In case of detection, if the ambient light level increases, the photocell will not turn o the light.
Factory settings
Luminosity threshold 400 lux
Lighting time 20 min.
Mode Presence
Power Up OFF
Active cell (Luminosity Cell) ON
Technical characteristics
Electrical characteristics
Supply voltage 230V~ +10/-15% 50/60Hz 240V~ +/-6% 50/60Hz Consumption with no load 2,4 VA / 270 mW
Upstream protection circuit breaker 16 A
Functional characteristics
Lighting output operating time 1 min. 1 h Brightness level 5 1000 Lux Recommended installation height 2,5 3,5 m Detection range Ø 7 m (installed product height: 2.5 m) Fixing accessorie Screws ( No 8), Protective cover Products can be connected in parallel. Hole size required 60 mm
Environment
Storage temperature -20 °C +60 °C Class of insulation II IK 03 Index of protection IP41 Fire resistance 650 °C Connection capacity (EEK510B)
0.5 mm2 to 1.5 mm2 flexible,
0.5 mm2 to 1.5 mm2 rigid Operating altitude 2000m Operating temperature :
Amperes (A)
16A
10A
Temperature (C°)
40°C 45°C
Correct Disposal of This product (Waste Electrical & Electronic
Equipment)
(Applicable in the European Union and other European countries with separate collection systems).
This marking shown on the product or its literature indicates that it hould not be disposed with other household wasted at the end of its working life. To prevent possible harm to the envi ronment or human health from uncontrolled waste disposal, please separate this from other types of wastes and recycle it responsibly to promote the sustainable reuse of material re sources.
Household users should contact either the retailer where they
1
2
on
purchased this product, or their local government oce, for details of where and how they can take this item for environ
lux
mentally safe recycling. Business users should contact their supplier and check the
terms and conditions of the purchase contract. This product should not be mixed with other commercial wastes of disposal.
-
-
-
2 6LE000505C
Loading...
+ 2 hidden pages