Hager ECM140D User guide

Page 1
z i y
Technical data Technische data Dati tecnici
z i y
Data in compliance with EN 50470-1, EN 50470-3,
IEC 62053-21 and IEC62053-23
General characteristics Algemene karakteristieken Caratteristiche generali
Housing DIN 43880 Behuizing DIN 43880 Involucro DIN 43880 DIN Mounting EN 60715 Montage EN 60715 Montaggio EN 60715 DIN rail 35 mm Depth Diepte Profondità mm 60 Weight Gewicht Peso g 60
Operating features Bedieningsfuncties Funzionalità operative
6LE005484Ad
Connection to single-phase network - number
Storage of energy values
and conguration
Approval (according to EN 50470-1, EN 50470-3) Goedkeuring (volgens EN 50470-1, EN 50470-3) Omologazione (secondo EN 50470-1, EN 50470-3)
Reference Voltage (Un) Referentiespanning (Un) Tensione di riferimento (Un) VAC 230
of wires Internal ash non volatile memory Opslag van energiewaarden
Reference Current (Iref) Referentie stroom (Iref) Corrente di riferimento (Iref) A 5 Minimum Current (Imin) Minimumstroom (Imin) Corrente minima (Imin) A 0.25
ECM140D
Maximum Current (Imax) Maximale stroom (Imax) Corrente massima (Imax) A 40 Starting Current (Ist) Startstroom (Ist) Corrente di avviamento (Ist) A 0.020 Reference Frequency (fn) Referentie frequentie (fn) Frequenza di riferimento (fn) Hz 50
Sealable terminal cover Dimension Verzegelbare
schroefklemafdekkap
Afmetingen
Coprimorsetto sigillabile Dimensione
18
Number of phases / number of wires Aantal fasen / aantal draden Numero di fasi / numero di li - 1 / 2 Certied Measures Gecerticeerde maatregelen Misure certicate kWh
Accuracy Nauwkeurigheid Precisione
- Active Energies (accord. to EN 50470-3) - Reële energie (conform EN 50470-3) - Energia attiva (secondo EN 50470-3) classe B
- Active Powers (accord. to IEC 62053-21 and IEC 61557-12) - Reëel vermogen (conform IEC 62053-21 en IEC 61557-12) - Potenza attiva (secondo IEC 62053-21 e IEC 61557-12) classe 1
Supply Voltage and Power Consumption Voedingsspanning en Energieverbruik Tensione di alimentazione e potenza assorbita
Operating Supply Voltage range Bedrfsspanningbereik Intervallo tensione di alimentazione V 92 … 276 Maximum Power Consumption (Voltage circuit) Maximaal energieverbruik (Spanningscircuit) Potenza massima assorbita (circuito voltmetrico) VA / W ≤2 / ≤1 Maximum VA burden (Current circuit) @ Imax Maximale VA last (stroom circuit) @ Imax Massimo assorbimento VA (circuito amperometrico) @ Imax VA ≤1
Voltage Input Waveform Meetspanningsvorm Forma d'onda tensione di ingresso - AC Voltage impedance Impedantie spanningsingang Impedenza circuito voltmetrico 1 Current impedance Impedantie stroomingang Impedenza circuito amperometrico ≤20
92
45
Overload capability Overbelastingscapaciteit Capacità di sovraccarico
Voltage continuous Spanning doorlopend Tensione continuo VAC 276
temporary (1 s) tdelk (1 s) temporaneo (1 s) VAC 300
Current continuous Stroom doorlopend Corrente continuo A 40
temporary (10 ms) tdelk (10 ms) temporaneo (10 ms) A 1200
Measuring Features Meetfuncties Funzioni di misura
Voltage range Spanningsbereik Intervallo di tensione VAC 92 … 276
7 44
Current range Stroombereik Intervallo di corrente A 0.020 … 40 Frequency range Frequentiebereik Intervallo di frequenza Hz 45 … 65 Measured Quantities Gemeten hoeveelheden Quantità misurate - V, A, kWh, PF, Hz, kW
60
Display features Display functies Caratteristiche del display
Display type LCD Display type LCD Tipo di
Wiring diagram Cable stripping length and terminal screw torque
Aansluitschema Kabelstriplengte en aandraaimomenten van de
aansluitklemmen Schema di collegamento
Lunghezza di sguainatura del cavo e coppia della vite del morsetto
Active Energy 5 digits + 2 decimal digits Reële Energie 5 cfers + 2 decimalen Energia attiva 5 cifre + 2 cifre decimali kWh 0.01 … 99999.99 Voltage 3 digits + 2 decimal digits Spanning 3 cfers + 2 decimalen Tensione 3 cifre + 2 cifre decimali V 92.00 … 276.00 Current 2 digits + 2 decimal digits Stroom 2 cfers + 2 decimalen Corrente 2 cifre + 2 cifre decimali A 0.00 … 40.00 Power factor 1 digit + 2 decimal digits with sign + capac./
induc. indic.
Frequency 2 digits + 2 decimal digits Frequentie 2 cfers + 2 decimalen Frequenza 2 cifre + 2 cifre decimali Hz 45.00 … 65.00 Active Power 2 digits + 2 decimal digits with sign Reëel vermogen 2 cfers + 2 decimalen met teken Potenza attiva 2 cifre + 2 cifre decimali con segno kW 0.00 … 11.04 Display refresh period Toon verversingsperiode Frequenza di aggiornamento del display s 1
Optical metrological LED Optische metrologische LED LED metrologico ottico
Front mounted red LED (meter
constant)
proportional to active imp/exp Energy
Safety Veiligheid Sicurezza
Overvoltage category Overspanningscategorie Categoria di sovratensione - 3 Protective class Beschermingsklasse Classe di protezione classe II AC voltage test (EN 50470-3, 7.2) AC spanningstest (EN 50470-3, 7.2) Test di tensione AC (EN 50470-3, 7.2) kV 4 Degree of pollution Vervuilingsgraad Grado di inquinamento - 2 Operational voltage Nominale spanning Tensione di funzionamento V 300
6 8
Impulse voltage test (Uimp) Impulsspanningstest (Uimp) Test di tensione ad impulso (Uimp) 1.2/50 μs-kV 6 Housing material ame resistance UL 94 Behuizing materiaal vlamwerendheid UL 94 Resistenza alla amma del materiale
Ultrasonic safety welding between upper and lower housing part
Embedded M-Bus communication Geïntegreerde communicatie M-Bus Comunicazione incorporata M-Bus
Baud rate Baudrate Velocità Baud bps 300 … 9600 Unit load Busbelasting Carico singolo - 1 Address adjustable Adres Instelbaar Indirizzo regolabile
MID certied MID gecerticeerd Certicato MID
Isolation class SELV Isolatieklasse SELV Classe di isolamento SELV -
Environmental conditions Milieuomstandigheden Condizioni ambientali
Storage temperature range Opslagtemperatuur Temperatura di stoccaggio °C -25 … +70 Operating temperature range Bedrfstemperatuur Temperatura di funzionamento °C -25 … +55 Mechanical environment Mechanische omgeving Ambiente meccanico - M1 Electromagnetic environment Elektromagnetische omgeving Ambiente elettromagnetico - E2 Installation indoor only Installatie alleen binnen Installazione solo all'interno -
Altitude (max.) Hoogte (max.) Altitudine (max.) m ≤2000
Humidity yearly average, without
condensation on 30 days per year, without
condensation
IP rating in built-in condition (front part) IP rating in ingebouwde conditie (voorkant) Grado di protezione IP in condizione di incasso (parte
(*) For use in accordance with the MID Directive, the energy meter must be installed in a
distribution board/enclosure for modular products with a minimum protection rating IP30 The IP51 ratings apply to the meter parts exposed in front of (outside of) the cover of the enclosure.
1 Hager Electro S.A.S., Boulevard d’Europe, B.P. 3, 67215 OBERNAI CEDEX, France - www.hager.com Hager 09.19 OCOM 136679 6LE005484Ad
terminal block klemblok morsettiera - IP20
en IEC62053-23
Verbinding naar eenfasig netwerk - aantal
en cong.
Powerfactor 1 cfer + 2 decimalen + capaciteit./induc.
Aan voorzde gemonteerde rode LED (meter constant)
Ultrasoon veiligheidslassen verbinden bovenste en onderste behuizingsdelen
indic.
Vochtigheid jaarlks gemiddelde, zonder
(*) Voor gebruik in overeenstemming met de MID-richtln moet de energiemeter
worden gemonteerd in een verdeelkast voor modulaire producten met een minimale beschermingsklasse IP30. De IP51 is van toepassing op het gedeelte van de behuizing van de energiemeter dat door de afdekplaat heen naar buiten steekt..
draden Intern ash niet-vluchtig geheugen Memorizzazione dei valori
evenredig met actieve imp / exp Energie
condensatie op 30 dagen per jaar, zonder
condensatie
Dati conformi alle norme EN 50470-1, EN 50470-3, IEC
62053-21 e IEC62053-23
1 0
Connessione alla rete monofase - numero di li
di energia e congurazione
Memoria interna non volatile -
-
2
c
kWh kWh
visualizzazione
Fattore di potenza
LED rosso frontale (costante del
contatore)
dell'involucro Saldatura ad ultrasuoni di sicurezza tra la parte superiore e
quella inferiore della custodia
LCD - 7.0 / 5.2
1 cifra + 2 cifre decimali con segno + indic. capac. / indutt.
proporzionale all'energia
imp / exp. Attiva
- -1.00 … 1.00
p/kWh 5000
UL 94 classe V0
-
c
- 0 … 250
c
c
Umidità media annuale, senza condensa - ≤75%
su 30 giorni all'anno, senza condensa
frontale)
(*) Per l'utilizzo in conformità alla direttiva MID, il contatore di energia deve essere installato
in un quadro di distribuzione per apparecchi modulari con grado di protezione minimo IP30. Il grado di protezione IP51 è relativo a parti del contatore esterne al quadro (frontale dell'apparecchio).
- ≤95%
- IP51(*)
Page 2
z
6LE005484Ad
ECM140D
Safety instructions
This device must be installed only by a professional electrician tter according to local applicable installation standards.
this product when the power supplying is ON. Its use is only permitted within the limits shown and stated in the installation instructions. The device and the equipement connected can be destroyed by loads exceeding the values stated.
Operating principle
This M-Bus meter measures the active energy used in an electrical installation. This device can manage 2 tariffs controlled via communication. Only the total active energy register can be used for billing purposes according to measuring instrument directive (MID).
- Active Energy Class B (according to EN 50470)
- Active Power Class 1 (according to IEC 62053-21 and IEC 61557-12) This device has a LCD and 1 push-button key to read Energies, V, I, PF, F, P and to congure some parameters. The design and manufacture of this meter comply with Standard EN 50470-3 requirements.
Product presentation
LCD display:
Symbols
One phase
Do not plug in or unplug
Energy register (kWh), not resettable
Energy import (consumption ) Energy export (production
)
One phase energy meter, direct connection 40 A
with MID declaration of conformity and M-Bus communication
MID certication concerns active energy only.
User instructions
EU declaration of conformity:
http://hgr.io/r/ecm140d
Operating M-Bus Communication
M-Bus MEDIA:
In a standard conguration, a M-Bus connection can be used to link up to 250* products with a PC or PLC, over a range of 1000 meters**. * depending on the M-Bus master. ** depending on the number of products and the communication speed.
Recommendations:
The use of a JYSTY Nx2x0.8 mm (0.5 mm²) unshielded twisted pair is recommended. If the range of 1000 m and/or the limit of 250 products are exceeded, a repeater will need to be connected. If the 250 limit is exceeded: only use the secondary address.
M-Bus protocol
The M-Bus protocol operates using a master/slave structure. ECM140D (slave) units are compatible with both primary and secondary addressing modes. Primary addressing can be congured via the product interface. Secondary addressing uses a xed, unique address shown on the product. M-Bus ECM140D units also have the «Wildcard addressing» function which allows products to be searched for on the M-Bus network. Option to broadcast to addresses 254 and 255. In addition, M-Bus product units are OMS compatible (Open Metering Systems).
M-Bus table:
Download from: http://hgr.io/r/ecm140d
Error condition:
When the display shows the message ERROR 2 or ERROR 3, the meter has got a malfunction and must be replaced.
1 s
Main page is depending on current power direction indication
with the corresponding global and partial energy register
display.
< 1 s
< 1 s
< 1 s
< 1 s
< 1 s
< 1 s
< 1 s
< 1 s
< 1 s
Meter type
Active energy imported
Active energy exported
Active Power (in this case: imported
Power factor
Primary Address:
)
Voltage
Current
Frequency
0 ... 250
Baud Rate:
300-600-1200-
4800-9600
2400
> 3 s
< 1 s
< 1 s
...
> 3 s
< 1 s
< 1 s
...
> 3 s
< 1 s
< 1 s
> 3 s
> 3 s
Short press to change
value
Short press to change
value
Long press to validate
value
Short press to change
value
Short press to change
value
Long press to validate
value
Short press to change
value
Short press to change
value
Long press to validate
value
Long press to modify
current value
- Change: short press
- Validate: long press
Protected by double insulation (Class II)
Backstop: Reversal preventing device
Commands
Command button: Short press: Push briey (<1 sec.) the button and then release it. Used to scroll pages or during parameter’s modication. Long Press: Keep the button pushed for at least 3 seconds. Used to start and to conrm parameter’s modications.
Optical metrological LED
Note:
If no button is pushed for at least 20 seconds the display goes back to the Main Page.
Power factor Convention according to IEC 62053-23
kW
- +
II I
Q
II I
kvar
kvar
+
-
IV
kW
Secondary Address not
< 1 s
< 1 s
< 1 s
< 1 s
< 1 s
S
P
modiable
Serial number
Software version and
checksum
Display test
PF ≤0 PF ≥0
2 Hager Electro S.A.S., Boulevard d’Europe, B.P. 3, 67215 OBERNAI CEDEX, France - www.hager.com Hager 09.19 OCOM 136679 6LE005484Ad
Page 3
i
6LE005484Ad
ECM140D
Veiligheidsinstructies
Dit apparaat mag alleen worden geïnstalleerd door een professionele installateur in overeenstemming met de geldende installatienormen.
dit product niet aan of koppel het niet los b ingeschakelde spanning. Het gebruik ervan is alleen toegestaan binnen de aangegeven grenzen en vermeld in de installatie-instructies. Het apparaat en het aangesloten apparaat kunnen worden beschadigd door belastingen die de vermelde waarden overschrden.
Werkingsprincipe
Deze M-Bus-meter meet de actieve energie die wordt gebruikt in een elektrische installatie. Dit apparaat kan 2 tarieven beheren die via communicatie worden beheerd. Alleen het totale actieve energieregister kan voor factureringsdoeleinden worden gebruikt volgens de meetinstrumentrichtln (MID).
- Reële energieklasse B (volgens EN 50470)
- Reële vermogensklasse 1 (volgens IEC 62053-21 en IEC 61557-12) Dit apparaat heeft een LCD en 1 druktoets om Energies, V, I, PF, F, P te lezen en om enkele parameters te congureren. Het ontwerp en de fabricage van deze meter voldoen aan de vereisten van norm EN 50470-3.
Productpresentatie
LCD scherm:
Energieregister (kWh), niet opnieuw instelbaar
Energie-import (consumptie ) Energie-export (productie
Symbolen
Een fase
Beschermd door dubbele isolatie (klasse II)
Backstop: apparaat om achteruitrden te voorkomen
Commando's
Command knop: Korte druk: Druk kort (<1 sec.) Op de knop en laat deze dan los. Wordt gebruikt om door pagina's te bladeren of tdens de wziging van de parameter. Lang indrukken: Houd de knop minstens 3 seconden ingedrukt. Wordt gebruikt om de wzigingen van de parameter te starten en te bevestigen.
Optische metrologische LED
Sluit
)
Eenfase energiemeter, directe stroommeting 40 A
met MID-verklaring van overeenstemming en M-Bus-communicatie
MID certicering heeft alleen betrekking op werkelke energie.
Gebruikersinstructies
EU-conformiteitsverklaring:
http://hgr.io/r/ecm140d
Operationele M-Bus-communicatie
M-Bus MEDIA:
In een standaardconguratie kan een M-Bus-verbinding worden gebruikt om tot 250 * producten te verbinden met een pc of PLC, over een bereik van 1000 meter **. * afhankelk van de M-Bus-master. ** afhankelk van het aantal producten en de communicatiesnelheid.
Aanbevelingen:
Het gebruik van een niet-afgeschermd getwist aderpaar JYSTY Nx2x0,8 mm (0,5 mm²) wordt aanbevolen. Als het bereik van 1000 m en / of de limiet van 250 producten wordt overschreden, moet een repeater worden aangesloten. Als de limiet van 250 wordt overschreden: gebruik alleen het secundaire adres.
M-Bus-protocol
Het M-Bus-protocol werkt met een master / slave-structuur. ECM140D (slave) -eenheden zn compatibel met zowel primaire als secundaire adresseringsmodi. Primaire adressering kan via de productinterface worden gecongureerd. B secundaire adressering wordt een vast uniek adres gebruikt dat op het product wordt vermeld. M-Bus ECM140D­enheden hebben ook de functie "Wildcard-adressering" waarmee producten op het M-Bus-netwerk kunnen worden opgezocht. Optie om uit te zenden naar adressen 254 en 255. Bovendien zn de M-Bus­producteenheden OMScompatibel (open meetsystemen).
M-Bus-tabel:
Downloaden van: http://hgr.io/r/ecm140d
Foutconditie:
In de situatie dat de foutmeldingen ERROR 2 of ERROR 3 op het display verschnen dan is er een defect in de meter. In deze situatie moet de meter worden vervangen.
Powerfactor Conventie volgens IEC 62053-23
kW
kW
1 s
Hoofdpagina is afhankelk van de huidige aanduiding van
de stroomrichting
met het bbehorende algemeen en
gedeeltelke energieregisterscherm.
< 1 s
< 1 s
< 1 s
< 1 s
< 1 s
< 1 s
< 1 s
< 1 s
< 1 s
< 1 s
< 1 s
< 1 s
< 1 s
Meter type
Reële energie
geïmporteerd
Reële energie
geëxporteerd
Reëel vermogen
(in dit geval:
geïmporteerd
Spanning
Stroom
Frequentie
Powerfactor
Hoofdadres:
0 ... 250
Baudrate:
300-600-1200-
Secundair adres kan niet
worden gewzigd
Softwareversie en check
4800-9600
Serienummer
som
2400
Druk kort om de waarde
< 1 s
< 1 s
te wzigen
Druk kort om de waarde
te wzigen
...
Lang drukken om de
> 3 s
< 1 s
< 1 s
)
waarde te valideren
Druk kort om de waarde
te wzigen
Druk kort om de waarde
te wzigen
...
Lang drukken om de
> 3 s
< 1 s
< 1 s
> 3 s
> 3 s
> 3 s
waarde te valideren
Druk kort om de waarde
te wzigen
Druk kort om de waarde
te wzigen
Lang drukken om de
waarde te valideren
Lang indrukken om
de huidige waarde te
wzigen
- Verandering: korte druk
- Bevestig: lang indrukken
- +
Opmerking:
Als er ten minste 20 seconden lang op geen enkele knop wordt gedrukt, keert het display terug naar de hoofdpagina.
kvar
kvar
3 Hager Electro S.A.S., Boulevard d’Europe, B.P. 3, 67215 OBERNAI CEDEX, France - www.hager.com Hager 09.19 OCOM 136679 6LE005484Ad
+
-
II I
Q
II I
IV
PF ≤0 PF ≥0
< 1 s
S
P
Displaytest
Page 4
y
6LE005484Ad
ECM140D
Istruzioni per la sicurezza
Questo dispositivo deve essere installato esclusivamente da un elettricista professionista secondo le norme di installazione locali applicabili.
collegare o scollegare il prodotto quando è alimentato. Il suo utilizzo è consentito solo nei limiti indicati e dichiarati nelle istruzioni di installazione. Il dispositivo e le apparecchiature collegate possono essere danneggiati da carichi che superano i valori indicati.
Principio di funzionamento
Questo contatore M-Bus misura l'energia attiva utilizzata in un'installazione elettrica. Questo dispositivo può gestire 2 tariffe controllate tramite comunicazione. Solo il registro di energia attiva totale può essere utilizzato per la fatturazione in base alla direttiva dello strumento di misura (MID).
- Classe Energia Attiva B (secondo EN 50470)
- Classe Potenza Attiva 1 (secondo IEC 62053-21 e IEC 61557-12) Questo dispositivo ha un display LCD e 1 pulsante per leggere Energia, V, I, PF, F, P e per congurare alcuni parametri. La progettazione e la fabbricazione di questo strumento sono conformi ai requisiti della norma EN 50470-3.
Presentazione del prodotto
Display LCD:
Registro di energia (kWh), non resettabile
Energia importata (consumata ) Energia esportata (prodotta
Symboli
Monofase
Protetto da doppio isolamento (Classe II)
Backstop: dispositivo anti inversione
Non
)
Contatore di energia monofase, inserzione diretta 40 A
con dichiarazione di conformità MID e comunicazione M-Bus
La certicazione MID riguarda solo la energia attiva.
Istruzioni per l'utente
Dichiarazione di conformità UE:
http://hgr.io/r/ecm140d
Funzionamento della comunicazione M-Bus
M-Bus MEDIA:
In una congurazione standard, è possibile utilizzare una connessione M-Bus per collegare no a 250 * prodotti con un PC o PLC, entro un raggio di 1000 metri **. * a seconda del master M-Bus. ** a seconda del numero di prodotti e della velocità di comunicazione.
Raccomandazioni:
Si consiglia l'uso di un doppino non schermato JYSTY Nx2x0,8 mm (0,5 mm²). Se viene superato il raggio di 1000 m e / o il limite di 250 prodotti, sarà necessario collegare un ripetitore. Se il limite 250 viene superato: utilizzare solo l'indirizzo secondario.
Protocollo M-Bus
Il protocollo M-Bus funziona utilizzando una struttura master / slave. Le unità ECM140D (slave) sono compatibili con entrambe le modalità di indirizzamento primario e secondario. L'indirizzamento primario può essere congurato tramite l'interfaccia del prodotto. L'indirizzamento secondario utilizza un indirizzo sso e univoco riportato sul prodotto. Le unità M-Bus ECM140D dispongono anche della funzione «Indirizzamento predenito» che consente la ricerca di prodotti sulla rete M-Bus. Opzione per trasmettere agli indirizzi 254 e 255. Inoltre, i prodotti M-Bus sono compatibili con OMS (Open Metering Systems).
Piattaforma M-Bus:
Scarica da: http://hgr.io/r/ecm140d
Condizione di errore:
Quando il display mostra il messaggio ERROR 2 o ERROR 3, lo strumento ha un malfunzionamento e deve essere sostituito.
1 s
La pagina principale dipende dall'indicazione della direzione
della potenza impostata
registro di energia globale e parziale.
con il corrispondente display del
< 1 s
< 1 s
< 1 s
< 1 s
< 1 s
< 1 s
< 1 s
< 1 s
< 1 s
< 1 s
Tipo di contatore
Energia attiva importata
Energia attiva esportata
Potenza attiva
(in questo caso:
importato
Frequenza
Fattore di potenza
Indirizzo principale:
)
Tensione
Corrente
0 ... 250
Velocità Baud:
300-600-1200-
Indirizzo secondario non
4800-9600
modicabile
2400
> 3 s
Premere brevemente per
< 1 s
< 1 s
modicare il valore
Premere brevemente per
modicare il valore
...
> 3 s
< 1 s
< 1 s
Premere a lungo per convalidare il valore
Premere brevemente per
modicare il valore
Premere brevemente per
modicare il valore
...
> 3 s
< 1 s
< 1 s
> 3 s
> 3 s
Premere a lungo per convalidare il valore
Premere brevemente per
modicare il valore
Premere brevemente per
modicare il valore
Premere a lungo per convalidare il valore
Premere a lungo per
modicare il valore corrente
- Modicare: breve
- Confermare: premere
pressione
a lungo
Comandi
Pulsante di comando: Breve pressione: Premere brevemente (<1 sec.) Il pulsante e quindi rilasciarlo. Utilizzato per scorrere le pagine o durante la modica dei parametri. Premere a lungo: Tenere premuto il pulsante per almeno 3 secondi. Utilizzato per iniziare e confermare le modiche del parametro.
LED metrologico ottico
Fattore di potenza Convenzione secondo IEC 62053-23
kW
kW
< 1 s
< 1 s
< 1 s
Numero di serie
Versione software e
checksum
- +
Nota:
Se non viene premuto alcun pulsante per almeno 20 secondi, il display torna alla pagina principale.
kvar
kvar
4 Hager Electro S.A.S., Boulevard d’Europe, B.P. 3, 67215 OBERNAI CEDEX, France - www.hager.com Hager 09.19 OCOM 136679 6LE005484Ad
+
-
II I
Q
II I
IV
PF ≤0 PF ≥0
< 1 s
Test di visualizzazione
S
P