hager 46CE, 46NK, 46BE, 46DT, 46NL Installation Instructions Manual

Page 1
4600 Series Narrow Stile Trim
46CE
Cylinder Escutcheon Key Locks & Unlocks Levers Requires a mortise cylinder (3902) and “L” Cam (3976) with radius 0.637” (16mm). Both sold separately.
46NK
Night Lever Lever Operable When Key Is Turned. Key Removable Only When Locked
Requires a mortise cylinder (3902) and “L” Cam (3976) with radius 0.637” (16mm). Both sold separately.
46BE
Blank Escutcheon Always Operable
46DT
Dummy Pull When Exit Device Is Dogged
46NL
Night Latch Key Retracts Latchbolt Requires a RIM cylinder (3901) and extra long tailpiece (2-639-7058). Both sold separately.
Handing Pin
Mounting Post (2 places)
Cylinder Cam
Cylinder Nut
Adjustable Tailpiece
DEVICES COVERED IN THIS DOCUMENT:
46CE Cylinder Escutcheon – Key locks and
unlocks lever
46DT Dummy Trim – Pull when dogged 46BE Blank Escutcheon – Always operable
46NL Night Latch – Key retracts latchbolt
46NK Night Lever (09 Function) – Lever operable
when key is turned. Key removable only when locked.
Cylinder Collar
Mortise Cylinder
Lever Handle
(46CE Cylinder Escutcheon Shown)
Installation Instructions I-ED01164
Rev 3, Rev Date: 8/4/2017 27390048 Page 1 of 5
Hager Companies 139 Victor Street, St. Louis, MO 63104 (800) 325-9995 www.hagerco.com
Page 2
4600 Series Narrow Stile Trim
APPLICATIONS
4950 BLADE STOP STRIKE SINGLE DOOR
4920 STANDARD STRIKE SINGLE DOOR
4920 STANDARD STRIKE AND MULLION
4952 SEMI-FLUSH STRIKE AND MULLION
4920 Standard Strike Application Single or Double Door Panic Exit Hardware (4912 strike available for fire-rated applications)
4952 Semi-Flush Strike Application Single or Double Door Panic Exit Hardware
TOOLS REQUIRED
4950 Blade Stop Strike Application Single Door Panic Exit Hardware
4920 Standard Strike Application Single or Double Door Panic Exit Hardware (4920F Strike Available for Fire Rated Applications)
Installation Instructions I-ED01164
Rev 3, Rev Date: 8/4/2017 27390048 Page 2 of 5
Hager Companies 139 Victor Street, St. Louis, MO 63104 (800) 325-9995 www.hagerco.com
Page 3
4600 Series Narrow Stile Trim
1. SET TRIM HANDING
A. Rotate lever handle to the right or left direction to match the desired door handing. B. Align the handle for the desired door handing position and then insert the square handing pin into the trim
escutcheon as shown below.
2. INSTALL MORTISE CYLINDER (for CE and NK trim only)
A. Install mortise cylinder into collar and
escutcheon trim.
B. From the back of the trim escutcheon
screw cylinder nut onto mortise cylinder until secure.
Test Installation (CE trim only)
Insert the key and rotate counterclockwise. Turn the lever handle and observe the tailpiece. It should be unlocked and the tailpiece will rotate. Rotate the key clockwise to lock the trim. Verify that the tailpiece does not rotate when the handle is turned.
Test Installation (NK trim only)
Insert the key and rotate counterclockwise. While keeping the key rotated, turn the lever Handle and observe the tailpiece to see if it has rotated. The handle should cause the tailpiece to turn only when the key remains turned. Release the key. Rotate the lever handle and confirm that the tailpiece is not turning.
Left Hand Reverse (LHR) show
Square Handing Pin
Cylinder Nut
5/8” Collar
46CE Cylinder Escutcheon
Mortise Cylinder Part # 3902 with 3976 Cam R 0.637” (16mm) (Ordered separately)
Installation Instructions I-ED01164
Rev 3, Rev Date: 8/4/2017 27390048 Page 3 of 5
Hager Companies 139 Victor Street, St. Louis, MO 63104 (800) 325-9995 www.hagerco.com
Page 4
4600 Series Narrow Stile Trim
3. INSTALL NIGHT LATCH RIM CYLINDER (for NL trim only)
A. Replace standard length tailpiece with extra-long tailpiece (2-3/8”). B. Install rim cylinder into collar and escutcheon trim. C. Install cylinder mounting bracket from back side of escutcheon trim as shown below. D. Adjust break-off screws to eliminate excess length and secure rim cylinder. E. Insert key and rotate. Observe the back of the trim and verify that the tailpiece rotates.
4. DRILL MOUNTING HOLES FOR ESCUTCHEON TRIM
A. Mark horizontal centerline by matching it to exit device centerline,
which can be found on the push side of the door.
B. Mark vertical centerline by matching it to exit device centerline,
which can be found on the push side of the door. Refer to Applications section on page 2 to determine the location of the vertical centerline.
C. Apply template to door using centerlines. D. Mark and drill holes as shown below.
i. Note that the mounting holes are the same for all functions but
the tailpiece clearance hole is different depending on function.
Note: Available templates include T-ED01194 – 4600 Trim Template (BE, CE,DT) and T-ED01195 – 46NL Trim Template
#12-24 Break-off screws
Cylinder Mounting Bracket
46NL Night Latch 5/8” Collar
RIM Cylinder Part No. 3901 & Extra Long Tailpiece Part # 2-639-7058 (Both Sold Separately)
Door Stile (Pull Side)
Frame
Note B
Note C
Note A
Note A
Notes:
A. Trim centerline corresponds to exit device centerline. B. Trim mounting clearance holes (2 places):
i. Drill ø 1/2” [13] holes on pull side. ii. Drill ø 5/16” [8] holes on push side.
C. Trim tailpiece clearance hole:
i. For CE, NK and BE functions:
1. Drill ø 3/4” [19] hole on pull side.
2. Drill ø 1/2” [13] hole on pull side. ii. For NL function, drill ø 1/2” [13] thru hole. iii. Not required for DT function.
Installation Instructions I-ED01164
Rev 3, Rev Date: 8/4/2017 27390048 Page 4 of 5
Hager Companies 139 Victor Street, St. Louis, MO 63104 (800) 325-9995 www.hagerco.com
Page 5
4600 Series Narrow Stile Trim
5. ADJUST TELESCOPING ACTUATING SHAFT (for BE, CE and NK trim only)
A. The telescoping actuating shaft is preset at the factory for a 1-3/4” thick door. For thicker door applications
follow these steps:
i. Remove the small screw on the side of the actuating shaft and keep it handy for the next step. ii. Use the chart below to choose the appropriate setting for your door application. For other door/shim
kit thicknesses, use the closest larger size.
iii. Slide the center shaft out until it lines up properly with the setting you chose in the last step. iv. Replace the screw and secure. v. Check for proper engagement with the exit device in the next step.
INSTALL ESCUTCHEON TRIM
A. Insert trim mounting
posts and actuating shaft through door.
B. Mate trim actuating
shaft with cam on back of exit device.
C. Secure from push
side of door with provided ¼”-20 machine screws.
D. Test installation by
rotating lever handle or key to verify trim functions properly.
4600 Narrow Stile Exit Device
Adjust Shaft Length
Telescoping Actuating Shaft
Remove Screw
Preset Door Thickness Positions For Telescoping Actuating Shaft
3”
2-1/2”
2”
2-1/4”
1-3/4”
(Factory preset
46CE Cylinder Escutcheon
Door Stile
¼”-20 Mounting Screws
Replace Screw
Installation Instructions I-ED01164
Rev 3, Rev Date: 8/4/2017 27390048 Page 5 of 5
Hager Companies 139 Victor Street, St. Louis, MO 63104 (800) 325-9995 www.hagerco.com
Loading...