hager 4501, 4601 Installation Instructions Manual

Page 1
4500/4600 Series Electric Exit Device
Request to Exit (RX)
Latch Bolt Monitoring (LM)
Authorized Ingress (AI)
Electrical Specification
SPDT Monitoring Switch
Maximum Contact Rating: 3 AMP @125VAC 2 AMP @ 30VDC
SPDT Monitoring Switch
Maximum Contact Rating: 3 AMP @125VAC 2 AMP @ 30VDC
SPDT Monitoring Switch
Maximum Contact Rating: 3 AMP @125VAC 2 AMP @ 30VDC
Color Code for wires
Yellow Wire – Common Red Wire – Normally Open Grey Wire – Normally Closed Wire Gauge – #22 AWG
Black Wire – Common White Wire – Normally Open Red Wire – Normally Closed Wire Gauge – #22 AWG
Black Wire – Common Orange Wire – Normally Open Purple Wire – Normally Closed Wire Gauge – #22 AWG
Door fabricator to provide a
3/8” ** diameter (minimum)
Raceway through door to
Allow insertion of electrical
Wires running between exit
Device and power transfer
device
DEVICES COVERED IN THIS DOCUMENT:
LM – Latch Bolt Monitoring * DE – Delayed Egress ELR – Electric Latch Retraction (not for use with Mortise Exit)* AI – Authorized Ingress * RX – Request to Exit (Field Installation Kit 2-649-5001) * RX2 – Dual Request to Exit ED – Electric Dogging * ET – Electric Trim (4500 Series only) EL or EU – Electrified Mortise Trim (ordered with 4501N Exit) * OBDE-On-Board Delayed Egress MLR – Motorized Latch Retraction (Field Installation Kit 2-649-5007) *
* Quick Connects Optional
** Quick Connects Require 5/8” Raceway
Installation Instructions I-ED00367
For use with all Hager monitored exit device modifications. Request to Exit (RX) switch monitors egress by push bar activation of the exit device. Latch Bolt Monitoring (LM) switch monitors the latch mechanism of the exit device. Authorized Ingress (AI) switch monitors ingress by trim or key retraction of the exit device latch.
WIRE ROUTING AND DOOR PREP INSTRUCTIONS
1. Follow exit device instructions and template to prepare door and frame for installation.
2. Door fabricator to provide a 3/8” ** diameter (minimum) raceway through door to allow insertion of
electrical wires running between exit device and power transfer device (electric hinge).
Rev 8, Rev Date: 8/27/2018 27390025 Page 1 of 3
Hager Companies 139 Victor Street, St. Louis, MO 63104 (800) 325-9995 www.hagerco.com
Page 2
4500/4600 Series Electric Exit Device
Installation Instructions I-ED00367
Notes:
1. Wire entry hole location on door (see example below): a. This dimension depends on the backset and specific door application. Please see exit device
instructions to determine backset and exit device location.
b. This dimension also depends on whether the device length has been field modified. Please note
that the standard 3-foot exit device with ELR and Electric Dogging cannot be cut from the factory length. Standard 3 foot exit devices with MLR can be cut a maximum of two inches.
Example – Single 3-foot door with RIM device. Please refer to individual 4500/4600 Series Installation template for approprite dimension.
2. Mount exit device end cap and wires: a. Follow exit device instructions and template to install end cap bracket. b. Route wires as shown in diagram below and terminate at power transfer device.
3. The EL, EU functions for the Mortise Exit Device are available for the Night Latch Version only (4501N).
These electrifications are ordered with the device but are included in the Mortise Exit Lock Body.
4. The ELR, MLR, DE and ED all occupy the same space in the push bar. None of these can be done in
conjunction with each other or with cylinder dogging or any Alarm Kit functions.
Rev 8, Rev Date: 8/27/2018 27390025 Page 2 of 3
Hager Companies 139 Victor Street, St. Louis, MO 63104 (800) 325-9995 www.hagerco.com
Page 3
4500/4600 Series Electric Exit Device
Quick Connect
Harness Cable Pinning
8 Pin
Wire Color
Pin # 1
Black
Pin # 2
Red
Pin # 3
White
Pin # 4
Green
Pin # 5
Orange
Pin # 6
Blue
Pin # 7
Brown
Pin # 8
Yellow
4 Pin
Color
Pin # 1
Violet
Pin # 2
Gray
Pin # 3
Pink
Pin # 4
Tan
1 4 3 21 8 7 6 5 4 3 2 1 4 3 21 8 7
6 5 4 3 2
4501/4601 Quick Connect Pinning
8 Pin
Function
Wire Color
Pin # 1
Power*
Color*
*Color (Power)
Pin # 2
Power*
Color*
• Black (ED)
Pin # 3
RX (Com)
Yellow
• White (MLR)
Pin # 4
RX (N/O)
Red
• Blue (ELR)
Pin # 5
RX (N/C)
Gray
Pin # 6
AI (Com)
Black
Pin # 7
AI (N/O)
Orange
Pin # 8
AI (N/C)
Purple
4 Pin
Function
Color
Pin # 1
Blank
Blank
Pin # 2
LM (Com)
Black
Pin # 3
LM (N/O)
White
Pin # 4
LM (N/C)
Red
NOTE: Pin harness as needed.
Hager Quick Connect
Harness Cable
(Sold Separately)
Hager Exit Quick
Connect Terminals
Installation Instructions I-ED00367
QUICK CONNECTS
- Quick connects are installed on the wires from the exit device electrification options. These quick
connects are compatible with Hager Quick Connect Harness Cable which can be used to plug into Hager hinges with quick connects to provide quick and accurate wiring of the door.