hager 2978 Installation Instructions Manual

Page 1
2978 No-Touch Wave-To-Exit Switch
Installation Instructions
I-EA00062
Rev 1, Rev Date: 1/27/14
Always visit www.hagerco.com for the latest Installation Instructions
HAGER COMPANIES 139 Victor Street, St. Louis, MO 63104 (800) 325-9995
INSTALLATION INSTRUCTIONS
MODEL 2978 WAVE-TO-EXIT SWITCH
· Device is activated with the simple wave of a hand
· Designed to control electric locks/strikes, magnetic locks,
or automatic door operators
· Ideal for use in cleanrooms, hospitals, labs, schools, or
offices
· Sensing range up to 4" (10cm)
· Mounted on a durable stainless steel plate
· Dual LED, illuminated sensor indicates status
· Quick connect screwless terminal block for easy
installation.
NOTE:
The HAGER 2978 must be mounted to a single-gang electrical back box or plaster ring.
1. Unscrew the four rear cover screws. Remove the rear cover to expose the 8-position screwless terminal block.
2. Feed the wiring through the wall to the back box. Feed the wiring through the gasketed hole of the rear cover. Verify that the wire leads are on the inside of the rear cover.
3. Connect the wires onto the screwless terminal block (see page 2 for typical wiring examples). Verify that each wire is securely terminated by gently pulling on each wire.
4. Replace the rear cover of the sensor switch, and secure the four cover screws.
5. Mount the stainless steel faceplate onto the back box using the two supplied screws. Be careful not to pinch any wires when mounting the device.
6. Apply 12VDC power to the device. The LED indicator ring will turn RED.
7. Test for proper activation by placing a hand within 4" of the sensor. The LED sensor ring will change from RED to GREEN, and both relays will activate.
Installation & Operation
Dimensions
No
Touch
EXIT
Screwless
Terminal Block
Connections
12/24VDC
PWR
Relay#
1
Specifications
1-"
(29mm)
2-¼"
(56mm)
4-½"
(115mm)
2-¾"
(70mm)
1-¾"
(45mm)
Side View Front View Rear View
Rear Cover
Rubber Gasket Ring
Relay#2
+
-
NO
NC
C
NO
NC
C
text
No
Touch
EXIT
Input Voltage
Current @
12VDC 24VDC
Contact Rating
LED Color
Range
Standby
Active
Output Activation
Time
Operating Temp.
Weight
Dimensions
30mA 15mA
Standby
70mA 35mA
Active
(2) Form C Relays, 3A@30VDC (Resistive)
Red
Green
4" (10cm) max.
1 Second or as long as sensor is triggered
-4deg F ~ 131deg F (-20C ~ 55C) 3 oz. (85g)
4.5" X 2.75" x 1.375" (mm = 115 x 70 x 35)
Page 1 of 2
Page 2
2978 No-Touch Wave-To-Exit Switch
Installation Instructions
I-EA00062
Rev 1, Rev Date: 1/27/14
Always visit www.hagerco.com for the latest Installation Instructions
HAGER COMPANIES 139 Victor Street, St. Louis, MO 63104 (800) 325-9995
Typical Wiring Examples
2978
Terminal
Block
Connecting the Switch to an Access Control Panel or Door Operator:
Using the 2978 as a request to exit device in an access control system
To Access
Control
Panel
To 12/24VDC Power Supply
To Auto
Operator
+
­NO
NC
C
NO
NC
C
12/24VDC Relay#1 Relay#2
*NOTE: Refer to manufacturer’s
installation instructions for Power Supply, Keypad, & Lock wiring. Locks must be the same voltage as the power supply output.
FAIL
SECURE
LOCK
+
-
FAIL SAFE LOCK
+
-
2915/2916
Digital Keypad
12 or
24VDC
Main
Output
(+) (-)
2908
POWER SUPPLY
Touchless Sensor Power
+
-
NO
NC
C
NO
NC
C
12/24VDC
Relay#1 Relay#2
Terminal
Block
120V
A/C Mains
*
*
*
E
1
E
2
E
3
E
4
E
5
E
6
E
7
E
8
AUXILIARY RELAY
2 AMPS @ 28VDC MAX
+
-
KEY PAD POWER
12-24 VOLTS
AC OR DC
SENSE
GROUND
REX
GROUND GROUND
OUTPUT 3
OUTPUT 4
GROUND
BLACK
GREEN
BLUE
BLACK
BLACK
VIOLET
BLACK
GRAY
MAIN RELAY
5 AMPS @ 28VDC MAX
NO
COM
NC
NO
NC
COM
}
}
}
2978
Page 2 of 2