It is essential to pay attention to these instructions in order to install the product
successfully and safely. Please pay attention to all of the specified installation steps,
instructions and notes!
These installation instructions are intended for:
• the operator of the product,
• the installer of the product.
In addition to these installation instructions, both groups of people must also have
read the separate operating instructions before handling the product.
The installer has the following obligations:
• All notes and specifications in the installation instructions must be complied with.
The installation steps must not be deviated from or varied.
• Only the supplied original parts must be installed.
• The installation instructions must be handed to the operator
after installation has taken place.
The operator has the following obligations:
• The installation requirements must be complied with.
• The product may only be installed and started up by qualified experts
(see Chapter “1.3 Personnel qualifications“ in the operating instructions).
• The instructions must be kept until the product is disposed of, and handed to the
new operator in the event of a change of operator.
1.4 Technical DataPower Supply: 6VDC by 4 AA Batteries
Power Input: max. 70mA
Operation Frequency:13,56 MHz
Modulation TypeASK
Antenna TypeLoop Antenna
Number of Channel1
Operation Temperature-10°C to 60°C
Reading Range0 - 40mm
2. Installation requirements
2.1 Ambient
conditions
In addition to the ambient conditions specified here, the instructions in the chapter
entitled “2.1 Correct purpose of use“ in the operating instructions also apply.
NOTE
The product may be damaged if it is installed under the wrong
ambient conditions!
The products must not be installed:
> on exterior doors,
> in humid environments,
> in the vicinity of electromagnetically sensitive devices,
> in potentially explosive environments.
HDE 16.06.2011 Dimensions in mm
2
NOTE
The product can be damaged by water condensing on cold
components!
> Before installation, please ensure that all product components
are at ambient temperature!
> Store products at the installation site for an appropriate period
prior to installation.
2.2 Installation
conditions
Door leaf
• Possible door leaf thicknesses: 38 - 80 mm,
• Possible door materials: Wood and wooden materials,
Mortise
• The mortise must be present, and must comply with the dimensioned drawing
Suitable screw-in cylinder for emergency opening
• The screw-in cylinder for emergency opening is not included in the scope of
• The size of the screw-in cylinder depends on the door leaf thickness.
• For help in calculating the length, see “Installation requirements“ on page 7.
3. Check scope of delivery
metal only after prior consultation with Häfele.
“Installation requirements“ on page 7.
delivery and must be ordered separately by the operator.
NOTE
The product may be damaged if the screw-in cylinder is used incorrectly!
The screw-in cylinder is for emergency opening only.
> Do not use the screw-in cylinder for normal door
locking / opening!
WARNING
Risk of suffocation from small parts and packing materials!
Screws, small parts and packing materials can be deadly playthings for
children.
> Do not leave the packing materials and the contents lying
around carelessly, and keep away from children and babies.
> Keep children away from the installation site during installation.
• Check completeness and condition of scope of delivery prior to installation.
For overview of scope of delivery, see illustrations starting
on page 6.
• If parts are missing or damaged, contact the manufacturer.
• Dispose of packaging materials in accordance with national regulations.
HDE 16.06.2011 Dimensions in mm
3
4. Installation
4.1 Safety instructions
for installation
WARNING
Risk of fatality due to lack of emergency opening facility!
If the product is installed without an emergency opening facility, it may
not be possible to open the door from the outside in the event of fault.
If emergencies occur inside the room during the fault, rescue work will
be hindered.
> The operator must ensure that doors to which this product is
fitted have an emergency opening facility in the event of faults.
> Häfele is not liable for damage that is attributable to failure to
install an emergency opening facility.
WARNING
Risk of fatality due to failures or faults in electromagnetically
sensitive devices!
The electromagnetic radiation of the product can cause faults in sensitive parts (e.g. in medical equipment). The functionality thereof will be
adversely affected.
> Do not mount product close to electromagnetically sensitive
devices.
> Pay attention to the safety instructions for the
electromagnetically sensitive devices.
> If you have any doubts regarding compatibility, please contact
the manufacturer.
4.2 Installation
description
NOTE
Damage to product due to incorrect installation!
> Adhere to installation requirements.
> Do not jam or damage wires during installation.
> Never start up and use the product if any wires have been
damaged.
> Always drill holes in the door leaf from both sides to prevent
pieces of the door from breaking away.
The installation is described using only pictures.
For step-by-step installation instructions, see picture section starting at page 8.