ECOMPACT 4
Economic & Compact Transient Immunity Test Station
The new ECOMPACT 4 combines the best of all
worlds: Performance, flexibility, economy and the
famous Haefely quality and reliability.
The ECOMPACT 4 is an ultra-compact immunity tester
that performs all the most commonly used transient
immunity tests, including Surge, EFT, Dips/Interrupts
and AC/Surge Magnetic Field. The simplified user
interface provides quick selection of tests and test
levels, and even lets you change test parameters “on
the fly” while running a test.
The actual EUT power mains voltage and current are
indicated in the display. Using the Electronic-Fuse
function, the user can set an upper limit for EUT power
mains current. This feature is useful to protect the EUT
from unnecessary damage.
By using the integrated safety-circuit and warning-lamp
functions a high degree of operator safety is
guaranteed.
The included “EMV-Check” software is compatible with
all latest windows versions, and allows full automation
of the test routine as well as data gathering and test
report generation.
Whether you test to the IEC 61000 series “CE Mark”
standards, the IEC 60601 Medical Device standards, or
any number of telecom and product specific standards,
the ECOMPACT 4 tester is your one stop test station for
everything from precompliance to full compliance to
product development testing.
A wide range of cost-efficient Coupling / Decoupling
Networks for symmetrical and asymmetrical data- and
signal-lines is available as an option.
With a 100 year history of innovation, service centers
on three continents, and a full staff of development and
support engineers, Haefely is the clear choice for all
your transient immunity test needs.
Features
Up to 6 complete EMC immunity standards in
a single test station
- IEC 61000-4-4 Ed.2 Electrical Fast Transient
- IEC 61000-4-5 Surge Combination Wave
- IEC 61000-4-8 AC Magnetic Field
- IEC 61000-4-9 Surge Magnetic Field
- IEC 61000-4-11 Ed.1 & 2 Dips & Interrupts
- IEC 61000-4-29 DC Dips
According to the latest editions of:
IEC 61000-4-4 & IEC 61000-4-11
Integrated 1-Phase Coupling Decoupling
Network
Optional automated 3-Phase 16A Coupling
Decoupling Network for Surge & EFT
available
Test routine Storage and Recall
Windows 98/2000/XP Software Included
Benefits
Multi-purpose – All basic immunity tests
combined in a single economical package for
maximum flexibility.
Quick and Simple – One touch operation and
simple automation of test routines streamlines the
test procedure.
Test Reporting – Included Windows software
automatically documents test parameters and
results
Reliable and Economical – World-renowned
Haefely quality, reliability, service and support in a
budget-friendly package.
Applications
Full Compliance and Pre-Compliance testing to a
wide variety of transient immunity standards:
IEC 61000-4-X “CE Mark” Basic Standards
IEC 60601 for Medical Equipment
IEC, ANSI, ITU, UL Product Standards

Technical Specifications
System Mainframe
Control Power 100/115/230V 50/60 Hz Dimensions (W x H x D) 48 x 18 x 44 cm
Memory Storage 20 positions Weight 30 kg
Communication Interface RS232, RS485
IEC / EN 61000-4-4 Edition 2 Electrical Fast Transient
Output Voltage 0.2 – 4.2 kV Spike Frequency 0.5 – 100 kHz
Polarity Positive and Negative Burst Duration 0.75 – 130 ms
Output Impedance 50 Ohms Burst Period 10 – 2400 ms
Rise Time 5 ns +/- 30% Spikes per Second Max. 2500 at U < 3 kV
Impulse Duration 50 ns +/- 30% (50 Ohms)
50 ns –15 +100 ns
(1 kOhm)
Integrated Single Phase
Coupling Decoupling
Network
Max. 1250 at U = 3 kV to 4.2 kV
33 nF coupling capacitance
1.5 mH decoupling inductance
230V AC/60V DC, 16A
IEC / EN 61000-4-5 Surge Combination Wave
Output Voltage 0.2 – 4.2 kV Output Current 0.1 – 2.1 kA
Voltage Rise Time 1.2 us +/- 30% Current Rise Time 8 us +/- 20%
Voltage Duration 50 us +/- 20% Current Duration 20 us +/- 20%
Polarity Positive and Negative Repetition Rate 10 s – 999 s
Output Impedance 2 Ohms
Synchronization 0 – 359 deg, 1 deg res.
Integrated Single Phase
Coupling / Decoupling
Network
230V AC / 60V DC, 16A
According to IEC/EN 61000-4-5
Edition 1&2
IEC / EN 61000-4-11 Edition 1 & 2 and IEC / EN 61000-4-29 Dips and Interrupts
Max. Voltage 250V AC/DC Interrupt Time 0.1 ms – 998 s
Max. Current 16A AC/DC Repetition Time 0.2 ms – 999 s
Dip Levels 0%, 40%, 70%, 80% Phase Synch. 0 – 359 degree asynchronous
ECOMPACT 4 Art. No. 249100
Qty. 1 ECOMPACT 4 Immunity Tester
Qty. 1 Safety Circuit Connector
Qty. 1 User Manual
Qty. 1 Power, EUT Power & Control Cable
Qty. 1 EMV-Check Software Diskette
16 / 40 / 50 / 60 Hz
Options & Accessories
ECOUPLER 4 3 Phase CDN 440V Phase to Phase
16A rms cont. / 25A rms short-time
PCD 121 Surge Coupling Network for
Symmetrical Data and Control Lines
PCD 126 Surge Coupling Network for
Asymmetrical Data and Control Lines
IP4A EFT Capacitive Coupling Clamp
MFS 100 Magnetic Field Test Set up to
1000 A/m Surge & 100 A/m Power
Frequency, incl. 1x1m coil & stand
“
EMV-Check” Automated Test Software
Headquarters
Haefely Test AG
Lehenmattstrasse 353
CH-4052, Basel
Switzerland
+ 41 61 373 41 11
+ 41 61 373 45 99
EMC-sales@haefely.com
Haefely has a policy of continuous product improvement. Therefore we reserve the right to change design and specification without notice. ECOMPACT4_2006-05-23.doc
Locate your local
sales representative at
www.haefelyEMC.com
North American Office
Hipotronics Inc.
Haefely EMC Division
1650 Route 22
Brewster, NY 10509
++1 845 279 3644 x264
++1 845 279 2467
EMCsales@hubbell-haefely.com