HACE CB-17 User Manual

Users manual
Portable air conditioner CB-17
A. Control panel
ON/OFF
ON/OFF
INCREASE & DECREASE TEMPERATURE
INCREASE & DECREASE TEMPERATURE
WATER FULL INDICATOR
SET TIMER
SET TIMER
SELECT FAN SPEED
SELECT FAN SPEED
SELECT MODE
SELECT MODE
B. Remote control
C. Water tank and water hose connection
D. Exhaust hose
E. Window kit
5
Please read this manual carefully before installing and using your air conditioner.
Store the manual in a safe place for future reference and product warranty.
www.tesscandinavia.se
Users manual HACE air conditioner CB17
Table of contents
2 ............................................................. Technical drawings
6 ............................................................. English
9 ............................................................. Swedish
12 ............................................................. Danish
15 ............................................................. Norwegian
6
Security warnings:
• The unit must be instal­led in accordance with national wiring regula­tions.
• If the power cord is damaged, it must be
replaced by qualied
personnel.
• Children should not play with the unit.
• The unit is for indoor use only.
• Do not switch the unit off by unplugging its power cord.
• Do not put any objects into the unit’s air inlet or outlet.
• Keep the unit away from water sources.
Place the unit on a at and solid surface.
• Keep the unit away from heat sources and inam­mable goods.
• Do not use the unit in cooling mode if the ambient temperature is above +35°C.
• The maximum length of the exhaust hose is 1500 mm. Do not extend or use a longer hose as this might seriously da­mage the air conditioner.
Do not bend or ex the exhaust hose more than
45° to ensure sufcient air ow.
• The remote control uses
AAA batteries. Use alkaline batteries only. Do not use rechargeable batteries.
Installation
• If the unit has been transported horizontally, keep it in an upright po­sition for 2 hours before using it.
Place the unit on a at and solid surface.
• Do not install the unit in bathrooms or other wet environments.
Make sure that air ow isn’t blocked - always keep at least 50 cm distance to surrounding surfaces.
Installing the exhaust hose
• Attach the adapter to one end of the hose and connect the other end to the back of the air conditioner.
• Extend the exhaust hose and lead it outside through a door or win­dow.
Using the window kit
• To use the window kit, open the window and place the window kit either horizontally or vertically, depending on the window.
• Adjust the length of the window kit. Shut the window and attach the
adapter on the exhaust hose to the window kit.
Protection functions
Automatic defrost
The unit will automatically defrost when needed.
Compressor protection
The unit has a compressor protection function causing a 3-minute start delay after the unit is restarted.
Water full alarm
When the water tank is full, the unit will stop working and a water-full indication light is shown. Empty the water tank and restart the unit.
Operating instructions
1. Starting the unit
Press the POWER button to start and stop the unit.
2. Select mode
The unit has 3 different modes; cooling, auto, and dry mode. Press MODE on the control panel or remote control to select mode.
Cooling mode
Set desired temperatu­re with the TEMP + and TEMP - buttons on the control panel or the remote control.
Set temperature is shown in the display for few seconds. After, the display returns to show the room temperature. Select fan speed with the SPEED button.
English
7
Dry
In dry mode the unit will dehumidify the room. Fan speed and temperature cannot be set. Do not use the air exhaust hose when using the unit in dry mode.
Auto
In auto mode, the unit will automatically set mode depending on the room temperature
Room temperature below 23°C: Only the fan runs
Room temperature between 23-26°C: Dry mode
Room temperature above 26°C: Cooling mode
3. Set timer
Press the TIMER button one time to set time for automatic shut off. Press it again to set time for automatic start.
Set time with the TEMP + and TEMP - buttons on the control panel or remote control
4. Set fan speed
Press the SPEED button on the control panel or remote control to choose fan speed.
Water drainage
Empty the water tank
Remove the water stopper. Empty the water tank and re-attach the water stopper.
Connecting a water hose for direct drainage
Unscrew the drain cover and remove the water stopper. Attach a 13 mm water hose to the pipe on the unit. Lead the other end of the water hose to a drain. Make sure that the water can be drained downwards.
The air lters
The air lters keep dust
and dirt from entering the air conditioner.
It is very important that the lters are cleaned regular­ly; otherwise the unit may be seriously damaged.
Therefore, clean the lters
at least once every two weeks.
Filter cleaning
• Remove the back and
side lters.
Clean the lters with warm water and a mild detergent.
Make sure that the lters are fully dried before reinserting them.
Maintenance and storage
• Clean the body of the unit with a soft cloth. Do not use strong solvents as this might damage the surface of the unit.
• Store the unit in a dry environment, away from direct sunlight. Drain the water before storage.
Warranties and service
2 years product warranty. The warranty is only valid with proof of purchase.
For all service and warran-
ty claims, you should rst
contact your retailer.
English
8
Problem Cause Solution
The unit doesn’t start Is the power cord connected? Connect the power cord
Is the water tank full? Empty the water tank
Is the room temperature above 35°C or below 10°C?
Increase or decrease the room temperature
Is the room temperature lower than set tempe­rature?
Change set temperature
Bad cooling effect Is the unit placed in direct sunlight? Move the unit or close the curtains
Are the doors or windows open? Close doors and windows
Are the lters dirty? Clean the lters
Is the air inlet or outlet jammed? Make sure that air ow isn’t blocked
High noise level Is the unit placed on an uneven ground? Place the unit on a at and solid
ground
The compressor doesn’t work
Overheat protection is activated Wait until the temperature decreases,
the unit will automatically restart
The remote control doesn’t work
Too long distance or the remote control isn’t aimed at the unit?
Bring the remote control closer and aim it towards the unit
Does the batteries need replacing? Replace the batteries
Error code E0 Tube temperature sensor problem Contact retailer Error code E2 The water tank is full Empty the water tank.
Trouble shooting
If you are having trouble with your unit, please refer to below trouble shooting. If nothing of the below works, please contact your retailer for servicing of your unit.
English
KLIMASKLEP ul. Orzechowa 3 72-010 Przęsocin (koło Szczecina)
tel.: (91) 432-43-42 tel.: (91) 432-43-49
e-mail: sklep@klimasklep.pl www: www.KlimaSklep.pl