HAAS + SOHN KOMFORT IV 180.18-AL User Manual

Page 1
Product no.
Description
20 0618618005036
Art. Nr. 0618018109000 V14 A16
Complete product information
, „HAAS+SOHN KOMFORT IV
180.18-AL“
718
1
16
2 3
14
17
13
9 5
18
7
19
Ø100
270150
15
781
Note: Labels with the short designations are attached to the mounting parts.
1. Install first row: first HSM (rear block centre) (top groove rearward), then rear blocks left and right (top groove rearward) and front blocks.
2. Insert bottom blocks 1, 2 and 3.
3. Insert ash pan (5) and grate (9).
4. Install second row: rear blocks and lateral blocks.
5. Insert insulating block (16) and draught deflector plate (10). Installation of the insulating block: Insert insulating block (16) with the short edge into the upper sheet steel groove
(see drawing) and let slip into the lower sheet steel groove. Installation of the draught deflector plate: Insert draught deflector plate (10) slantwise (bevelled corners at the back) and place it on the lateral sheet steel angles, then lift the front edge and place it on the support plate.
Important: Push the draught deflector plate to the front until the limit stop is reached! Important: After cleaning of the appliance, or before returning it to service, checks must be carried out to ensure that
the baffle plates are in the correct position (see diagram). Suitable fuels:
The following fuels are permitted for use in your wood burning stove (see also section 5.1): Dry, well seasoned, unadulterated wood and wood briquettes which comply with DIN 51731
No.
1
6
2 0618018105300
10
3 5 0618018005600
8
6 0618018015002
20
7 0089000020005 8
12
9 0020100130005
11
10 0050500040005
11 12 0618516075310
13 0420114005371 14 0618018025301 15 0088400060005 16 0050500050005 17 0618018105035 18 0088500050005
19
Body of the stove Door to the combustion
chamber Refractory
Ashpan Supports for the
exhaust flue Adjustable feet
Secondary air Grate 260x152 Plate for diverting the
exhaust Glases angled upwards
Air intake control Fitting for the door
handle Door handle
Inspection window Door spring Insulating brick Door latch Socket for the pipe
supplying air from outside Ø 100
Air duct Bottom plate
Page 2
Description of the system for supplying the air needed for combustion:
The system for supplying the air needed for combustion in stove unit type 180.18-AL has three settings: the primary air is adjusted by means of the air intake control(11) With the handle in position 2 (‘right’) the primary air. I enters through the grate, and the primary air II enters through that area of the combustion chamber which is to wards the front of the stove. With the handle in position 1 (‘middle’) the primary air I only enters via the grate. The amount of secondary air is set at an optimum level for the unit to provide the necessary ventilation to keep the window clean and to provide the necessary air for secondary combustion; it is permanently adjusted for increased comfort. The pre­heated secondary air flows past the top end of the inspection window (8).
Air intake control
2
"right"
Primary air I open
Primary air II open
Use: For use when it is heating up and after fuel has been added
1
"middle"
0
"left"
shut shut
open shut
In normal operation Only for keeping the embers glowing
Connection for providing the air needed for combustion:
In airtight buildings there can be reduction in the oxygen content of the room in which the stove is set up; it must therefore be ensured that there is adequate ventilation. The stove unit type 180.18-AL therefore offers you the possibility of drawing in the air needed for combustion from outside. The stove can then be operated without having to depend on the air within the room. In order to do this the air from outside that is needed for combustion is supplied by means of a flexible pipe attached to the socket for the pipe (18). It is possible for you to change the position of the pipe socket to the left, right or rear of the stove unit. The end of the pipe carrying the air must be located in the open air, or in a well ventilated room situated within the building. Operation of the stove unit in connection with an air conditioning and ventilation system is permitted. When installing the stove unit in connection with an automatic air conditioning and ventilation system the end of the pipe supplying the air must not be located in a room which is connected to this system.
The amount of fuel and adjustment of the air intake control:
Lighting, and heating the appliance up: see sections 5.4, 5.5 and 5.6 in the instructions for use of the stove. Use the gloves provided to protect you against the heat when operating the air intake control. Before every addition of fuel, the air intake control is to be closed completely (handle setting ‘left’).
Brennstoffe maximale Brennstoffmenge Primärluft: Luftregler Sekundärluft (ohne
Regelung)
Scheitholz 2 - 3 Scheite (ca. 2 – 2,5 kg) 10 Minuten lang Hebelstellung „2“ Holzbriketts 1 Holzbrikett (2 kg)
Tip for burning wood: Every time the stove is lit leave the appliance in the ‘right’ position until the fuel is burning well (around 10 minutes). (This time can vary somewhat depending on the amount of draught and the pressures involved).When adding fuel shut the air intake as indicated.
(rechts), dann Hebelstellung „1“ (Mitte)
offen
Typenbezeichnung:
Variante:
Herstellnummer: Wärmeleistungsbereich: Nennwärmeleistung Zugelassener Brennstoff: Staub bez.auf 13% O2: 22 mg/Nm³ Wirkungsgrad: 80,3% CO bez. auf 13% O2: 0,10% Abgastemperatur am Stutzen: 320°C Nox bez. 13% O2: 96 mg/Nm³ HC bez. auf 13% O2: 42 mg/Nm³ Mindestabstände seitlich: zu brennbaren Bauteilen: hinten:
Prüfstellenkennziffer: 1625 / Prüf Nr. RRF- 29 12 3110
Lesen und befolgen Sie die Bedieungsanleitung!
Mehrfachbelegung des Schornsteins ist zulässig
Kamineinsatz Bauart : EN 13229-W / Zeitbrandfeuerstätte
Prüf Nr. VKF:
HAAS + SOHN OFENTECHNIK GMBH
URSTEIN NORD 67 A-5412 PUCH
Holz, Holzbrikett nach - DIN 51731,
vorne im Strahlungsbereich:
Anbringungsjahr 2013
Komfort – IV 180.18 AL
Komfort-III 180.18-AL
1303180800085
3,9 - 8,3 kW
siehe Aufstellungs-und
Bedienanleitung
80 cm
180.18
8,0 kW
Page 3
Prüf. Nr.
Stove unit:
Komfort I
V 180.18
-AL:
Kaminbausätze:
Description
intems
Product no.
RRF Oberhausen stove „Alpes-II“, RRF-40 06 1033
stove „Jura-II“: RRF-40 06 1033 stove “Genf-II” RRF-40 08 1686 stove “Adonis“ RRF-40 12 3013
RRF-29 12 3110
Fitting the combustion chamber lining for the
„HAAS+SOHN Komfort IV 180.18-AL“
HSL
SL
BS1 BS3 BS2
HW
HSR
HSM
BS1 (stone 1) 1 0050110490005 BS2 (stone 2) 1 0050110500005 BS3 (stone 3) 2 0050110480005 SR (stone right) 1 0050110120005 SL (stone left) 1 0050110110005 HSM (stone middle) 2 0050110060005 HSR (stone right) 2 0050110070005 HSL (stone left) 2 0050110140005 IS (isulating brick) 1 0050500050005 Z (plate) 1 0050500040005 ZU (bottom plate) HW (holder)
IS
ZU
Z
SR
1 0618618005036 3 0618618005035
Page 4