Haas+Sohn Exquisit 182.18-AL Instructions Manual

Product number. 0618218019030
V09 G07
Complete product information,HAAS+SOHN Exquisit 182.18-AL”
Product number 0618218010000
Installation of the combustion chamber liner:
Note: Labels with the short designations are attached to the mounting parts.
2. Insert bottom blocks (F, G and H).
3. Insert ash pan (5) and grate (9).
4. Install second row: rear blocks (A) and lateral blocks (B,I,J).
5. Instell front blocks(K,L,M)
5. Insert insulating block (16) and draught deflector plate (10). Installation of the insulating block: Insert insulating block (16) with the short edge into the upper sheet steel
groove (see drawing) and let slip into the lower sheet steel groove. Installation of the draught deflector plate: Insert draught deflector plate (10) slantwise (bevelled corners at the back) and place it on the lateral sheet steel angles, then lift the front edge and place it on the support plate.
Important: Push the draught deflector plate to the front until the limit stop is reached! Important: After cleaning of the appliance, or before returning it to service, checks must be carried out to
ensure that the baffle plates are in the correct position (see diagram).
No. Product no. Description
1 Body of the stove 2 0618218015300 Door to the combustion
chamber 3 Refractory 4 Wood storage compartment 5 0618018005600 Ashpan 6 0618018015002 Supports for the exhaust flue 7 0089000020000 Adjustable feet 8 Secondary air 9 0020100130005 Grate 260x152
10 0050500070005 Plate for diverting the
exhaust Glases
angled upwards
11 0618218010001 Air intake control 12 0081220020005 Fitting for the door handle 13 0081220040005 Door handle (for the door to
the combustion chamber)
14 0618218015301 Inspection window 15 0088400060000 Door spring 16 0050500060000 Insulating brick 17 0087255300095 Door latch 18 0088500050005 Socket for the pipe supplying
air from outside Ø 100
19 Air duct
Suitable fuels: The following fuels are permitted for use in your wood burning stove (see also section 5.1): Dry, well seasoned, unadulterated wood and wood briquettes which comply with DIN 51731
1
Product number. 0618218019030
V09 G07
Description of the system for supplying the air needed for combustion :
The system for supplying the air needed for combustion in stove unit type 182.18_AL has three settings: the primary air is adjusted by means of the air intake control(11) With the handle in position 2 (‘left’) the primary air. I enters through the grate, and the primary air II enters through that area of the combustion chamber which is to wards the front of the stove. With the handle in position 1 (‘middle’) the primary air I only enters via the grate. The amount of secondary air is set at an optimum level for the unit to provide the necessary ventilation to keep the window clean and to provide the necessary air for secondary combustion; it is permanently adjusted for increased comfort. The pre-heated secondary air flows past the top end of the inspection window (8).
Air intake control Primary air I Primary air II Use:
For use when it is heating up and after
"left" open open
"middle" shut open In normal operation
"right" shut shut Only for keeping the embers glowing
Connection for providing the air needed for combustion:
In airtight buildings there can be reduction in the oxygen content of the room in which the stove is set up; it must therefore be ensured that there is adequate ventilation. The stove unit type 182.18-AL therefore offers you the possibility of drawing in the air needed for combustion from outside. The stove can then be operated without having to depend on the air within the room. In order to do this the air from outside that is needed for combustion is supplied by means of a flexible pipe attached to the socket for the pipe (18). It is possible for you to change the position of the pipe socket to the left, right or rear of the stove unit. the air must be located in the open air, or in a well ventilated room situated within the building. Operation of the stove unit in connection with an air conditioning and ventilation system is permitted. When installing the stove unit in connection with an automatic air conditioning and ventilation system the end of the pipe supplying the air must not be located in a room which is connected to this system.
Fuels Amount of fuel Primary air:
air intake control Chopped wood Wood briquettes:
2 to 3 pieces of wood (approx. 2 to 2.5kg) or 1 wood briquette (2kg)
For approximately 10 minutes: open
(handle to the left),
then operate with the handle in
the middle position
The amount of fuel and adjustment of the air intake control:
Lighting, and heating the appliance up: see sections 5.4, 5.5 and 5.6 in the instructions for use of the stove. Use the gloves provided to protect you against the heat when operating the air intake control. Before every addition of fuel, the air intake control is to be closed completely (handle setting ‘left’). Tip for burning wood: Every time the stove is lit leave the appliance in the ‘right’ position until the fuel is burning well (around 10 minutes). (This time can vary somewhat depending on the amount of draught and the pressures involved).When adding fuel shut the air intake as indicated.
Wärmeleistungsbereich:
Zugelassener Brennstoff:
Staub bez.auf 13% O
Prüfstellenkennziffer: 1625 / Prüf Nr. RRF-29 06 1188
Lesen und befolgen Sie die Bedieungsanleitung! Mehrfachbelegung des Schornsteins ist zulässig
Kamineinsatz Bauart : EN 13229-W / Zeitbrandfeuerstätte
Typenbezeichnung:
Herstellnummer:
Nennwärmeleistung
Prüf Nr. VKF: 11108 NOx: 93 mg/Nm³ HC: 44 mg/Nm³
HAAS + SOHN OFENTECHNIK GMBH
URSTEIN NORD 67 A-5412 PUCH
2:
28mg/Nm³
Wirkungsgrad: 81,7% CO:0,10%
Stove unit: Exquisit 182.18-AL: RRF Essen RRF-29 06 1188 Stove EN13240:
stove „Colmar“, RRF-40 02 476
fuel has been added
The end of the pipe carrying
Secondary air (not adjustable) open
Exquisit 182.18-AL
JH 03 000085
4,7 - 9,2kW
8,0 kW
Holz, Holzbrikett nach -DIN 51731,
2