Electrical Service Manual 96-0284F RevF English January 2009
•This content is for illustrative purposes.
•Historic machine Service Manuals are posted here to provide information for Haas machine owners.
•Publications are intended for use only with machines built at the time of original publication.
•As machine designs change the content of these publications can become obsolete.
•You should not do mechanical or electrical machine repairs or service procedures unless you are qualied
and knowledgeable about the processes.
•Only authorized personnel with the proper training and certication should do many repair procedures.
WARNING: Some mechanical and electrical service procedures can be
extremely dangerous or life-threatening.
Know your skill level and abilities.
All information herein is provided as a courtesy for Haas machine owners
for reference and illustrative purposes only. Haas Automation cannot be held
responsible for repairs you perform. Only those services and repairs that are
provided by authorized Haas Factory Outlet distributors are guaranteed.
Only an authorized Haas Factory Outlet distributor should service or repair a
Haas machine that is protected by the original factory warranty. Servicing by
Haas Technical Publications
Manual_Archive_Cover_Page Rev A
June 6, 2013
HAAS SERVICE AND OPERATOR MANUAL ARCHIVE
TITLE
• This content is for illustrative purposes.
• Historic machine Service Manuals are posted here to provide information for Haas machine owners.
• Publications are intended for use only with machines built at the time of original publication.
• As machine designs change the content of these publications can become obsolete.
• Y o u s h o u l d n o t d o m e c h a n i c a l o r e l e c t r i c a l m a c h i n e r e p a i r s o r s e r v i c e p r o c e d u r e s u n l e s s y o u a r e q u a l i e d
and knowledgeable about the processes.
• Only authorized personnel with the proper training and certication should do many repair procedures.
WARNING: Some mechanical and electrical service procedures can be
extremely dangerous or life-threatening.
Know your skill level and abilities.
All information herein is provided as a courtesy for Haas machine owners
for reference and illustrative purposes only. Haas Automation cannot be held
responsible for repairs you perform. Only those services and repairs that are
provided by authorized Haas Factory Outlet distributors are guaranteed.
Only an authorized Haas Factory Outlet distributor should service or repair a
Haas machine that is protected by the original factory warranty. Servicing by
any other party automatically voids the factory warranty.
SAFETY
RED
WHT
40
BLK
ON
OFF
Install lock-out clasp
and lock with padlock
to secure Circuit
Breaker in the
OFF position.
To avoid possible shock, make sure circuit breakers are appropriately locked off before attempting any
electrical work.
CAUTION! Working with the electrical services required for the machine can be extremely
hazardous. The electrical power must be off and steps must be taken to ensure
that it will not be turned on while you are working with it. In most cases this means
turning off a circuit breaker in a panel and then locking the panel door. However ,
if your connection is different or you are not sure how to do this, check with the
appropriate personnel in your organization or otherwise obtain the necessary
help before you continue.
WARNING!
The electrical panel should be closed and the three screws/latches on the
door should be secured at all times except during installation and service. At
those times, only qualied electricians should have access to the panel. When
the main circuit breaker is on, there is high voltage throughout the electrical
panel (including the circuit boards and logic circuits) and some components
operate at high temperatures. Therefore extreme caution is required.
GENERAL ELECTRICAL TROUBLESHOOTING
MACHINE NOT RUNNING
Machine cannot be powered on.
• Check input voltage to machine.
• Check main circuit breaker at top right of electrical cabinet; switch must be at the on position.
• Check overvoltage fuses.
• Check wiring to Power Off button on front control panel.
• Check wiring to Auto Off relay to I/O PCB.
• Check connection between 24V transformer (T5) and K1 contactor.
• Check 24V transformer (T5) bracket has jumper in correct position (measure voltage at main circuit breaker
and connect jumper to corresponding connector on T5 transformer bracket).
• Check I/O PCB.
• Check Power PCB.
96-0284 rev F January 2009
Electrical Service
1
Machine can be powered on, but turns off by itself.
• Check Settings #1 and #2 for Auto Off Timer or Off at M30.
• Check alarm history for Overvoltage or Overheat shutdown.
• Check AC power supply lines for intermittent supply.
• Check low voltage power supply for intermittent supply.
• Check wiring to Power Off button on front control panel.
• Check connection between 24V transformer and K1 contactor.
• Check I/O PCB.
• Check Parameter 57 for Power off at E-Stop.
• Check MOTIF or MOCON PCB.
Machine turns on, keyboard beeps, but no LCD/CRT display.
• Check for power connections to LCD/CRT from I/O PCB (LVPS power from Power PCB for 15” monitor).
Check for green Power LED at front of CRT.
• Close doors and zero return machine (possible bad monitor).
• Check video cable from Video PCB to LCD/CRT.
• Check for lights on the processor.
• Replace LCD/CRT.
Machine turns on, LCD works, but keyboard keys do not work.
• Check keyboard cable (700) from Video to SKBIF PCB.
• Check keypad.
• Check SKBIF PCB.
Constant E-Stop Condition (will not reset) (Vertical Machines).
• Check hydraulic counterbalance pressure, low pressure switches, and cabling.
Quad APC trouble shooting
The Quad APC uses an additional PC board to control pallets 3 and 4.
The pallet chain motor receives 160VDC from plug 6A on this board (32-3078A). The PC board receives
power (115V) from the power card, which plugs into P4 on the APC board.
The solenoid for the left, air operated, automatic door plugs into P3; this cable is part of 33-6038A. Pallet 3
and 4 signals are sent through cable 33-1516, which plugs into P1. The cable’s other end plugs into the I/O
board P62.
LECTRICAL ALARM TROUBLESHOOTING
E
Axis Drive Fault Alarm
• Blown amplifi er - indicated by light at bottom of amplifi er when power is on. Replace the fuse in the amplifi er.
• Amplifi er or MOCON is noise sensitive. If this is the case, the alarm can be cleared and the axis will run
normally for a while.
To check an amplifi er, switch the motor leads and control cables between the amplifi er and the one next to
it. If the same problem occurs with the other axis, the amplifi er must be replaced. If the problem stays on the
same axis, either the MOCON or control cable. The problem could also be the axis motor itself, with leads
either shorted to each other or to ground.
2
Electrical Service
96-0284 rev F January 2009
• Amplifi er faulting out for valid reason, such as overtemp, overvoltage, or +/-12V undervoltage condition. This
usually results from running a servo intensive program, or unadjusted 12V power supply. Adjust voltage to
correct specifi cations or replace the power supply.
Overvoltage could occur if regen load is not coming on, but this does not usually happen. The problem could
also be the axis motor itself, with leads either shorted to each other or to ground.
Axis Overload
• The fuse function built into the MOCON has been overloaded. This may be caused by a lot of motor accel/
decels, or hitting a hard stop with the axis. This safety function protects the amplifi er and motor. If the current
program is the cause, change the program. If the axis hits a hard stop the travel limits may be set wrong.
Phasing Error
• The MOCON did not receive the proper phasing information from the motors. Do not reset the machine if
this alarm occurs. Power the machine down and back up. If the problem persists, it is probably a broken wire
or faulty MOCON connectors. This problem could also be related to the Low Voltage Power Supply. Check to
see if the LVPS is functioning properly.
Servo Error Too Large
• This alarms occurs when the difference between the commanded axis position and the actual position
becomes larger than the maximum that is set in the parameter.
This condition occurs when the amplifi er is blown, is not receiving the commands, or the 320V power source
is dead. If the MOCON is not sending the correct commands to the amplifi er, it is probably due to a broken
wire, or a Phasing Error that was generated.
Axis Z Fault or Z Channel Missing
• During a self-test, the number of encoder counts was found to be incorrect. This is usually caused by a noisy
environment, and not a bad encoder. Check all shields and grounds on the encoder cables and the motor
leads that come into the amplifi ers. An alarm for one axis can be caused by a bad grounding on the motor
leads of another axis.
Axis Cable Fault
• During self-test, encoder cable signals were found to be invalid. This alarm is usually caused by a bad cable,
or a bad connection on the motor encoder connectors. Check the cable for any breaks, and the encoder
connectors at the motor controller board. Machine noise can cause this alarm, although it is less common.
Alarm 101, “MOCON Comm. Failure”
• During self-test of communications between the MOCON and main processor, the main processor does not
respond, and is suspected to be dead. This alarm is generated and the servos are stopped. Check all ribbon
cable connections, and all grounding. Machine noise can also cause this alarm, although it is less common.
Alarm 157, MOCON Watchdog Fault
• The self-test of the MOCON has failed. Replace the MOCON.
Alarm 212, Program Integrity Error/Alarm 250, Program Data Error
• If a program has been corrupted in the system or a corrupted program has been loaded into the machine,
a Program Data Error (250) or Program Integrity Error (212) might occur. This occurrence can be recognized
by an exclamation point (!) next to a program when turning to the list program page. Following is the common
procedure to perform when this happens.
1. Save all programs to disk except the program with the exclamation point error signal. The exclamation
point (!) indicates the program that is corrupt. This will be your back-up disk to reload the programs into the
machine.
2. Delete all the programs. This should delete all the programs including the one with the “!” error signal.
3. If the program with the exclamation point (!) does not erase then the control needs to be initialized.
96-0284 rev F January 2009
Electrical Service
3
4. If the machine still has the program with the exclamation point or the control now refuses to load a good
program, it may be necessary to clear memory and reload software.
5. If problem persists, replace main processor board.
Alarm 261, Rotary CRC Error (Horiz & Vert)
This alarm is normally the result of an incomplete software installation. To correct this error:
Press Emergency Stop.1.
Turn Setting 7 to OFF. 2.
Go to Setting 30 and select HRT210. Make note of this and all following changes. 3.
Go to Parameter 43 and change the fi rst bit from 0 to 1. 4.
Go to setting 30 and select HRT310. 5.
Go back to Parameter 43 and change the second bit from 0 to 1. 6.
Now reverse the changes you have made. 7.
Cycle power to the machine. The alarm will now be cleared. 8.
If the alarm persists, repeat the above steps before calling for assistance.
Alarm 354, Aux Axis Disconnected (Lathe)
When this alarm is generated, do not press Reset. Turn Setting 7 Off. Enter Debug mode, then view the
Alarms/Messages page. On the Messages page, a code will appear similar to WO1. The list of codes and
their descriptions follows :
WO1Power was just turned on or failed. Check the ribbon cables from the Aux Axis PCB to the proces-
sor for correct routing. Check for communication problems between the processor and the Aux
Axis PCB.
WO2Servo following error too large. Check the encoder for contamination or dirt. Check for an
intermittent connection at both ends of the motor cable.
WO3 Emergency Stop. The E-STOP button was pressed, or an E-STOP condition occurred.
WO4 High load. Check for binding in the tool changer gearbox and motor. Rotate the carousel by hand
and feel for any binding. Make sure the toolholders are the correct weight.
WO5Remote RS-232 commanded off. Check the ribbon cable and the voltage to the Aux Axis PCB.
Check for 115V AC (minimum) to the Aux Axis PCB from the main transformer. Check the fuse holder and the fuse that is protecting this circuit.
WO6Air or limit switch or motor overheat. Check that the motor is not hot. Check for any binding in the
motor. Check for overweight tooling.
WO7Z channel fault. Either the encoder or the cable is bad. Change the encoder fi rst, as it is easier to
change than the cable. If the problem persists, change the cable.
WO8Over-current limit, stalled or PCB fault. Check for binding in the tool changer gearbox. Make sure
the belt is not too tight. Ohm out the motor cable, checking pins G to F (should be open), G to H
(should be open), and F to H (should read between 2.5 and 5 ohms). Check all the connections
on the Aux Axis PCB and motor cable.
WO9 Encode ES. Z channel is missing. Bad encoder or cable. See WO7.
WOA High voltage. Check the incoming voltage to the Aux Axis PCB. Incoming voltage must be 115V
AC. See WO5.
WOBCable fault. Check the cable from the motor to the Aux Axis PCB. Check for loose connections at
each end.
4
Electrical Service
96-0284 rev F January 2009
LINE VOLTAGE ADJUSTMENTS
Please read this section in its entirety before attempting to adjust the line voltage.
Tools Required: Large fl at tip screwdriver, Digital voltmeter
NOTE: The machine must have air pressure at the air gauge, or a “Low Air Pressure” alarm
will be present on power up.
Low VoltagePower Supply
T5 Transformer
MOCON-2
(if equipped)
LCD Video/Floppy
MOCON-1
Processor
3-Phase Breaker
Power PCB
Power Amplifiers
X, Y,Z, A, B & PC
Optional Servo
Tool Changer Amp
SERVODRIVE
ASSEMBLY
Haas Vector Drive
Wye-Delta Contactors
(underneath)
I/O Board
Single Axis Brake PCB
(if so equipped)
Transformer
Control Cabinet General Overview
ELECTRICAL CONNECTIONS
Ouput
Power
Ground Line
Main
Circuit
Breaker
L1L2
L3
TB2
240VOUT
D
A
488-458V
N
G
E
R
!
120VOUT
457-429V
260-244V
INCOMINGLINE VOLTAGETAPS (74,75, 76)
428-403V
243-227V
!
!
H
I
G
H
V
O
L
TB1
T
A
402-377V
226-211V
376-354V
210-195V
G
E
D
A
N
G
E
R
!
!
!
Input
Power
1. Place the main circuit breaker in the Off position and hook up the three power lines to the terminals on top
of the main circuit breaker at the upper right-hand side of the electrical panel. Connect the separate ground
line to the ground bus to the left of the terminals.
NOTE: Ensure service wires go into terminal-block clamps. (Do not miss clamp and tighten
screw. Connection looks fi ne but machine runs poorly - servo overloads.) To check,
pull on wires after screws are tightened.
96-0284 rev F January 2009
Electrical Service
5
2. After the line voltage is connected to the machine, make sure that main circuit breaker is off. Turn on the
power at the source. Using an accurate digital voltmeter and appropriate safety procedures, measure the
voltage between all three pair phases at the main circuit breaker and write down the readings. The voltage
must be between 195 and 260V (360 and 480V for high voltage option).
NOTE: Wide voltage fl uctuations are common in many industrial areas; you need to know
the minimum and maximum voltage which will be supplied to the machine while it is
in operation. U.S. National Electrical Code specifi es that machines should operate
with a variation of +5% to -5% around an average supply voltage. If problems with
the line voltage occur, or low line voltage is suspected, an external transformer may
be required. If you suspect voltage problems, the voltage should be checked every
hour or two during a typical day to make sure that it does not fl uctuate more than
+5% or -5% from an average.
CAUTION! Make sure the main circuit breaker is set to off and the power is off at the supply
panel before changing the transformer connections. Make sure that all three
black wires are moved to the correct terminal block and are tight.
3. Check the connections on the transformer at the bottom-right corner of the rear cabinet. The three black
wires labeled 74, 75, and 76 must be moved to the terminal block triple which corresponds to the average
voltage measured in step 2 above. There are four positions for the input power for the 260V transformer and
fi ve positions for the 480V transformer. The labels showing the input voltage range for each terminal position
are as shown in the previous illustration.
4. Transformer T5 supplies 24VAC used to power the main contactor. There are two versions of this
transformer for use on 240 and 400V machines (32-0964B and 32-0965B, respectively). The 240V
transformer has two input connectors located on the transformer bracket, which allow it to be connected
to either a 221-240V range or 180 to 220V range. Users that have 180-240V input power should place the
jumper on the appropriate connector.
The 400V transformer has three input connectors located on the transformer bracket, which allow it to be
connected to either a 441-480V range, 381-440V range or 340-380V range. Users with the External High
Voltage Option should place the jumper on the connector marked with the appropriate input voltage. Failure to
place the jumper on the correct input connector will result in either overheating of the main contactor or failure
to reliably engage the main contactor.
A jumper must also be placed on the plate covering the T5 transformer, Measure voltage at the main circuit
breaker and connect the supplied shorting plug to the corresponding connector on the T5 transformer plate.
5. Set the main circuit breaker to ON and check for evidence of problems, such as the smell of overheating
components or smoke. If such problems are indicated, immediately set the main circuit breaker to OFF and
call the factory before proceeding.
T5 Transformer
441-480V
Main
Circuit
Breaker
6
Electrical Service
221-240V
381-440V
180-220V
MEASURE VOLTAGEAT MAIN
CIRCUIT BREAKER AND CONNECT
SUPPLIED SHORTING PLUG TO
CORRESPONDING CONNECTOR
340-380V
ON THIS TRANSFORMER
T5 24VAC
WARNING:
96-0284 rev F January 2009
Through the Spindle Coolant (TSC) pump is a three phase pump and must
be phased correctly! Improper phasing will cause damage to the TSC pump
and void the warranty. Refer to the TSC start up section if your machine is
equipped with TSC.
6. After the power is on, measure the voltage across the bottom terminals on the main circuit breaker. It
should be the same as the measurements where the input power connects to the main circuit breaker. If there
are any problems, check the wiring.
7. Apply power to the control by pressing the Power On switch on the front panel. Check the high voltage
buss on the Vector Drive (pin 2 with respect to pin 3 on the terminal bus at the bottom of the drive). It must be
between 310 and 360V. If the voltage is outside these limits, turn off the power and recheck steps 2 and 3.
If the voltage is still outside these limits, call the factory. Next, check the DC voltage displayed in the second
page of the Diagnostic data on the display screen. It is labeled DC BUS. Verify that the displayed voltage
matches the voltage measured at pins 2 and 3 of the Vector Drive +/- 7V DC.
8. Electrical power must be phased properly to avoid damage to your equipment. The Power Supply
Assembly PC board incorporates a “Phase Detect” circuit with neon indicators, shown below (disregard for
single phase machines). When the orange neon is lit (NE5), the phasing is incorrect. If the green neon is lit
(NE6), the phasing is correct. If both neon indicators are lit, you have a loose wire. Adjust phasing by placing
the main circuit breaker in the Off position and swapping L1 and L2 of the incoming power lines at the main
circuit breaker.
PHASE DETECT
(FOR 3 PHASE ONLY)
PASSFAIL
WARNING!
NE5NE6
WARNING!
All power must be turned off at the source prior to adjusting phasing.
9. Close the door, lock the latches, and turn the power back on.
10. Remove the key from the control cabinet and give it to the shop manager.
96-0284 rev F January 2009
Electrical Service
7
FUSE REPLACEMENT
Please read this section in its entirety before attempting to replace any fuses.
Some of the brushless amplifi ers have one 15 amp fuse, F1. If this fuse blows, the associated motor will stop;
a light on the amplifi er will tell of a blown fuse. Use the Amplifi er Fuse Kit (Haas P/N 93-1089) to replace the
fuse. If the fuse blows again, the amplifi er may be damaged, and needs to be replaced.
The Power PCB contains three ½-amp fuses located at the top right (FU1, FU2, FU3). If the machine is
subject to a severe overvoltage or a lightning strike, these fuses will blow and turn off all power. Replace
these fuses only with the same type and ratings. FU 4, 5, and 5A protect the chip conveyor (FU6 is only used
with 3 phase motors).
Size Fuse Name Type Rating (amps) Voltage Location
5mm FU1-FU3 Slo-Blo ½ 250V PSUP pcb, upper right
1/4 F1 Ultra fast 15 250V Amplifi er (X, Y, Z, A, B)
5mm FU4, 5 Fast blow 5A 250V PSUP, bottom right corner
15” and Thin Pendant Machines
Size Fuse Name Type Rating (amps) Voltage Location
5x20mm F1/F3 Fast Acting 1 250V PSUP pcb, upper right
OVERVOLTAGE FUSES
The electrical panel will have residual voltage, even after power has been
shut off and/or disconnected . Never work inside this cabinet until the small
green Power On light on the servo amplifi ers (servo drive assembly on brush
machines) goes out. The servo amplifi ers/servo drive assembly is on the left
side of the main control cabinet and about halfway down. This light(s) is at the
top of the circuit card at the center of the assembly. Until this light goes out,
there are dangerous voltages in the assembly even when power is shut off.
1. Turn machine power off.
2. Place the main circuit breaker (upper right of electrical cabinet) in the off position.
WARNING!
Main
Switch
3. Open the cabinet door and wait until the red charge light on the servo drive assembly goes out before
beginning any work inside the electrical cabinet.
8
Electrical Service
96-0284 rev F January 2009
4. The two overvoltage fuses are located beside each other at the upper right of the Power Supply board. An
orange light will be on to indicate the blown fuse(s).
PHASE DETECT
(FOR3 PHASE ONLY)
+5V
GND
10A230V
FAILPASS
GND
+5V
NE6
WORKLIGHT
GFI/
7173
NE5
F1
NE1
TSC COOLANTPUMP
TSCCOOLANT PUMP
930
COOLANT/TSC
1A250V
10A230V
POWER SUPPLYASSY
SEC
PRI
TOT5
F3
NE3
PSUP-K
230VIN
CHIPCONVEYOR
CHIPCONVEYOR
170
AUTOOFF/CONTACTOR
740
ON/OFF
P10
5A230V
CB4
160
CHIPC230V
GND
+5V
PHASE DETECT
(FOR 3 PHASE ONLY)
GND
+5V
NE6
FAILPASS
7173
NE5
F1
NE1
1A 250V
PRI
TO T5
F3
NE3
IOPCB
GND
GND
+5V
+12V
P30
GND
GND
-12V
+12V
COOLANTPUMP
COOLANTPUMP
92A
DELTA-WYE
LOWVOLT PS
SWDOOR FAN
MONITOR
PROBEPS
SERVOFAN
90A
AC GROUND
90C
MCD1
MCD2
LVINPUT
GND
GND
GND
GND
+12V
90A
90A
90A
90A
96
90C
95
94/N
-12V
+12V
+12V
LE2
Z3
LE3
+12V
-12V
TS1
MAIN115V XFRMR
P1
ONONONONON
10A115V
115VINPUT
MAIN
XFRMR
CB2
115VSPARES
90C 90C
90C90C 90C
MOTIF
MOCON2
GND
GND
+5V
+5V
+5V
-12V
+12V
Z4
+12V
LE1
Z1
+5V
P18
AMPS
GND
+12V
-12V
GFI
7A115V
GFI
CB6CB3CB5
90
3PH115V TOIOPCB
Power Supply Board; Fuse Locations
5. Using a fl at tip screwdriver, turn the fuse(s) counterclockwise to remove the fuses. Replace the fuse(s) with
one having the same type and rating (½ amp, type AGC, 250V).
CAUTION! When the left fuse is blown, it is still possible to operate the machine, thereby
making an overvoltage situation possible. Verify absolute voltage to the machine
does not exceed 200V (max 260 leg to leg or leg to ground, or 400V on high
voltage machines - max 520V leg to leg or leg to ground).
FRONT PANEL
Please read this section in its entirety before attempting to replace any control panel component.
SL-10 PENDANT COMPONENTS ACCESS
The SL-10 pendant door hinges on the left side. Remove the two (2) screws on top of the pendant in order to
open the pendant door.
CAUTION! Do not pinch the cable as the door is closed.
96-0284 rev F January 2009
Electrical Service
9
LCD ASSEMBLY REPLACEMENT
CAUTION! Use an electrostatic discharge (ESD) strap on wrist when working inside the
pendant.
1. Turn the power off and disconnect power to the machine.
2. Remove the screws holding the cover on the back of the operator’s pendant. Take care to hold the cover in
place until all screws have been removed.
3. Disconnect the video out cable (J16) from the SKBIF PC board and backlight cable.
4. Remove the four (4) hex nuts and washers beginning with the bottom, then remove the LCD assembly and
set aside in a safe place.
CAUTION! Do not drop or damage the LCD when removing it from the control panel.
5. Use gloves to avoid getting fi ngerprints on the new LCD. Position the assembly onto the four bolts (two
each on top and bottom). Place the washers and hex nuts on the bolts to hold in place. Once all washers
have been attached and nuts have been hand-tightened, tighten down completely.
Video Out
to LCD
Pnl
J13
SKBIF
J16
Video In
Kybd
Data
In
Power In
Backlight cable
to inverter board
RS-232 Data
to/from
Microprocessor
Back of Operator’s Pendant
6. Plug the keyboard cables into the new receiver board (P1) and the power supply (TB2). Plug the power
cable into the power supply board (TB1) and attach the green wire to ground. Plug the data cable into the
receiver board (J3).
7. Replace the back cover panel and attach with the four screws previously removed.
JOG HANDLE
The Jog handle is actually a 100-line-per-revolution encoder, used to move one axis at a time. If no axis
is selected for jogging, turning the handle has no effect. When the axis moved reaches its travel limits, the
handle inputs will be ignored in the direction that would exceed the travel limits. Parameter 57 bit 0 can be
used to reverse the direction of operation of the handle.
Jog Handle Replacement
1. Turn the machine power off.
2. Remove the screws holding the cover on the back of the pendant. Take care to hold the cover in place until
all screws have been removed.
10
Electrical Service
96-0284 rev F January 2009
3. Unplug the cable leading to the jog handle encoder.
Blank pin goes to this
side of connector
+5V
BLK
Jog Handle Encoder Jog Handle Removal Jog Handle Wiring Diagram
A
RED
GND
WHT
+5V
RED
B
GRN
A
YEL
GND
WHT/
RED
B
BRN
A
WHT/
YEL
4. Using the 5/64” allen wrench, loosen the two screws holding the knob to the control panel and remove.
5. Remove the three screws holding the jog handle encoder to the control panel and remove.
6. Replacement is reverse of removal. Important! The blank pin side of the connector must face as shown
when reconnecting; otherwise, damage may occur to the machine.
POWER ON/OFF SWITCHES
The Power On switch engages the main contactor. The On switch applies power to the contactor coil and the
contactor thereafter maintains power to its coil. The Power Off switch interrupts power to the contactor coil
and turns power off. Power On is a normally open switch and Power Off is normally closed. The maximum
voltage on the Power On and Power Off switches is 24V AC and is present any time the main circuit breaker
is on.
B
WHT/
BRN
EMERGENCY STOP SWITCH
The Emergency Stop switch is normally closed. If the switch opens or is broken, servo power is removed
instantly. This will also shut off the turret, spindle drive, and coolant pump. The Emergency Stop switch will
shut down motion even if the switch opens for as little 0.005 seconds. Note that if Parameter 57 bit 3 is set to
1, it will cause the control to be powered down when Emergency Stop is pressed.
You should not normally stop a tool change with Emergency Stop as this will leave the tool changer in an
abnormal position that takes special action to correct
If the lathe turret or mill tool changer (T/C) becomes jammed, the control will automatically come to an alarm
state. To correct this, push the Emergency Stop button and remove the cause of the jam. Push the Reset key
to clear any alarms. Push Zero Return and the Auto All Axes to reset the Z-axis and turret or T/C. Never put
your hands near the turret or T/C when powered unless E-Stop is pressed.
KEYBOARD BEEPER
There is a beeper under the control panel that is used as an audible response to pressing keyboard buttons
and as a warning beeper. The beeper is a one kHz signal that sounds for about 0.1 seconds when any
keypad key, Cycle Start, or Feed Hold is pressed. The beeper also sounds for longer periods when an autoshutdown is about to occur and when the “Beep at M30” setting is selected.
If the beeper is not audible when buttons are pressed, the problem could be in the keypad, keyboard interface
PCB or in the speaker. Check that the problem occurs with more than one button and check that the beeper
volume is not turned down or disconnected. If lamps do not turn on, check the GFCI plug.
96-0284 rev F January 2009
Electrical Service
11
LAMP ON/OFF SWITCH
An on/off switch is supplied for the work lamp. It is located on the side of the operator’s pendant. The lamp
uses 115V AC taken from P19 on the main power distribution board.
SWITCH REPLACEMENT
1. Turn the machine power off. Remove the screws holding the cover on the back of the pendant. Take care to
hold the cover in place until all screws have been removed.
2. Disconnect all leads to the switch connectors. Ensure all leads are properly marked for reconnecting later.
3. Unscrew the two small set screws, one on top and one on the bottom, and turn the switch counterclockwise
to loosen. Separate from the front portion and pull out.
4. To replace, screw the front and rear portions together (reverse of removal) and tighten down the two small
set screws when the switch is properly positioned.
NOTE: The Power On, Power Off, and Emergency Stop switches must all have the connectors
on the bottom of the switch.
5. Reconnect all leads to the correct switch.
SPINDLE LOAD METER
Load meter measures load on spindle motor as a percentage of rated continuous power of motor, with a slight
delay between a load and actual meter refl ection. The eighth A-to-D input also provides a measure of spindle
load for cutter wear detection. Second page of diagnostic data displays % of spindle load. Meter should
agree with display within 5%. Spindle drive display #7 should also agree with load meter within 5%. There
are different types of spindle drives used in the control, all are equivalent in performance but are adjusted
differently.
Spindle Load Meter Replacement
1. Turn the power off and disconnect power to the machine. Remove the screws holding the cover panel on
the back of the pendant. Take care to hold the cover panel in place until all screws are removed.
2. Disconnect the two leads at the back of the spindle load meter assembly. Ensure the two leads are properly
marked for reconnecting later.
3. Unscrew the four screws that hold the spindle load meter assembly to the control panel. Take care to hold
the assembly in place until all screws have been removed. Remove the assembly.
4. Installation is reverse of removal. Ensure leads go to the correct location.
KEYPAD REPLACEMENT
1. Turn the power off and disconnect power to the machine. Remove the screws holding the rear cover to the
back of the pendant. Take care to hold the cover in place until all screws are removed.
2. Unplug the keypad’s 24-pin ribbon cable from the Keyboard Interface board.
3. Remove the screws from the front of the pendant. Take care to hold the cover in place until all screws have
been removed. Remove the pieces and set aside in a safe place.
4. Using a fl at, blunt tool, such as putty knife, pry the keypad away from the control panel. Pull the ribbon
cable through the opening in the control to remove.
5. To replace, fi rst put the bezel spacer in place and fasten temporarily with screws in the top corners.
12
Electrical Service
96-0284 rev F January 2009
Gasket
Glass
Keypad
Keypad Installation
Front Bezel
6. Insert the ribbon cable through the opening in the control panel. Expose the adhesive strip on the back of
the keypad and press it into place in the upper right corner of the keypad recess. Press to the control panel to
mount. Plug the ribbon cable into the Keyboard Interface board, taking care to not bend the pins.
7. Replace the front and rear cover panels and fasten with the screws that were previously removed.
SERIAL KEYBOARD INTERFACE REPLACEMENT
NOTE: Refer to “Cable Locations” for a diagram of this board.
1. Follow all precautions noted previously before working in the control cabinet.
2. Turn the main switch (upper right of electrical cabinet) to the off position.
3. Remove the four screws on the back of the control box, then remove the cover panel. Take care to hold the
panel in place until all screws have been removed.
4. Disconnect all leads to the Serial Keyboard Interface (SKBIF) board. Ensure all cables are properly labeled.
5. After all cables have been disconnected, unscrew the four screws holding the Serial KBIF board to the
control box. Take care to hold the board in place until all screws have been removed. Place the screws and
standoffs aside for later use.
6. Replace the Serial KBIF board, using the four screws previously removed. Starting at the top right, attach
each screw and standoff loosely, until all are mounted, then tighten down.
7. Reconnect all cables to the Serial KBIF board at their proper locations.
8. Verify whether the machine is equipped with either a speaker or a beeper. Align the toggle switches of
Switch 1 on the Serial KBIF board to their appropriate positions. Beeper operation requires that both S1
switches be set to ‘B’; speaker operation requires that both S1 switches be set to ‘S’.
96-0284 rev F January 2009
Electrical Service
13
SOLENOIDS
Please read this section in its entirety before attempting to replace any solenoid assemblies.
TOOL RELEASE PISTON (TRP) AIR SOLENOID ASSEMBLY (HORIZ & VERT)
Removal
1. Turn machine power on and raise spindle head to uppermost position, then turn the power off. Remove air
supply from machine.
2. Remove sheet metal at rear and/or top of machine to access the back of the spindle (Mechanical Service
manual).
3. Disconnect all air lines from the air solenoid assembly (Do not remove fi ttings). Disconnect the two leads
from the low air pressure sensor.
4. Unscrew the air solenoid assembly from the tool release piston assembly, taking care not disturb the
position of the clamp/unclamp switches. It may be necessary to remove the tool release piston to access the
solenoid assembly.
5. Unplug the wiring leading to the plug marked on the solenoid bracket as “880 from I/O PCB to Solenoid
Valves” and the plug marked “Spare”.
6. Unscrew the air solenoid from the air solenoid assembly. Remove the SHCS holding the assembly to the
bracket and remove the assembly.
Installation
1. Install the new air solenoid. Take care to not disturb the position of the clamp/unclamp switches.
2. Replace air solenoid assembly and attach to bracket with the SHCS previously removed. Tighten securely.
3. Reinstall the tool release piston assembly if removed (see Mechanical Service).
4. Reconnect the two leads to the low air preassure sensor. Reconnect wiring to plugs on solenoid bracket.
5. Ensure all air lines are reconnected to their proper fi ttings. Reconnect air supply to the machine, and check
for leaks.
6. Replace the sheet metal.
Air Solenoid
Assembly
EC
400
Check ValveSwitch
Pre-
Charge
Regulator
Check ValveSwitch
Basic Air Solenoid Assembly
Motor Shroud
TRP Solenoid
Inlet
Pressure
Switch
TRP
Solenoid
Air Solenoid
Assembly
EC
To TSC
Check
Valve
Switch
Air Solenoid Assembly
With TSC Feature Added
Sheet Metal
Tray
TSC Solenoid
Junction
Elbow
Low air pressure
sensor
Air solenoid
assembly
Disconnect
all air lines
Disconnect
all air lines
Locations of EC-300 and EC-400 TRP Solenoids VF-Series Air Solenoid Assembly
14
Electrical Service
96-0284 rev F January 2009
SPINDLE LUBE AIR SOLENOID
Removal
1. Turn the machine power off and remove the air supply from the machine.
2. a. Lathe: Disconnect the lube line from the spindle lube air solenoid assembly.
b. Mill: Disconnect the air lines from the spindle lube air solenoid assembly.
3. Disconnect the electrical leads from the main air line pressure switch.
4. Lathe: Unscrew the solenoid assembly pressure gauge from the assembly.
5. Unscrew the entire solenoid assembly from the T-fi tting.
Main Air Line
Pressure Switch
Installation
1. Reattach the solenoid assembly at the T-fi tting.
2. a. Lathe: Replace the pressure gauge on the solenoid assembly and reconnect the lube line.
b. Mill: Reconnect all air lines.
3. Reconnect the electrical leads to the main air line pressure switch.
1. Turn machine power off and remove the air supply from the machine.
2. Pneumatic Chuck: Disconnect the two air hoses from the pneumatic chuck clamp/unclamp solenoid.
Turret: Disconnect the three air hoses from the turret clamp/unclamp solenoid (see the Turret In/Out
Adjustment), and disconnect exhaust lines.
3. Unplug the solenoid electrical lead (located on the rear of the lube air panel).
4. Remove the two SHCS holding the assembly to the bracket and remove the assembly.
Installation
1. Replace the air solenoid assembly and attach it to the bracket with the two SHCS. Tighten securely.
2. Reconnect the electrical connection to the solenoid at the switch bracket.
3 Reconnect the two (three for Turret) air lines and turret exhaust lines, ensuring that all connections are tight
and do not leak.
4. Restore the air supply to the machine.
96-0284 rev F January 2009
Electrical Service
15
SMART AMPLIFIER
The Smart Amplifi er has a microprocessor incorporated in the design. This allows the amplifi er to detect and
report detailed alarms. The software level necessary to display these new alarms is 15.02A or newer.
The Smart Amplifi er is backward compatible to any machine that has a Vector Drive. New Smart Amplifi ers
and standard amplifi ers may be used in any combination in the machine. However, if the machine does not
have at least 15.02A software or newer the specifi c Smart Amplifi er will not be displayed. The Smart Amplifi er
and the standard amplifi er use the same Parameters. On non-thin pendant machines, at least two of the
standard amplifi ers must be used.
The Smart Amplifi er does not have a 12VDC connector, and both the Fault (Red LED) and the Run (Green
LED) are relocated. The 320VDC (H+ and H-) and the X, Y and Z-axis connections are also relocated.
The smart amplifi er will calibrate utilizing the microprocessor that is present in each of the Smart Amplifi ers
at power up. When power is applied to the Control Cabinet the Fault (Red LED) will illuminate and stay
illuminated for a short time (approximately 5 seconds), this is called the “A” Phase Calibration. Then both
LEDs will be out for a few seconds; this is called the “B” Phase Calibration. Next the Run (Green LED) will
illuminate, indicating the Smart Amplifi er is ready with no faults.
16
Electrical Service
96-0284 rev F January 2009
SMART VECTOR DRIVE
The smart vector drive features a microprocessor that allows it to detect and display specifi c alarms (software
version 15.02A or newer only). It is backward compatible to any machine with a vector drive regardless of
software version; however, the drive-specifi c alarms will not display in older software. Such alarms will dis-
play in the same way as with old-style drives.
Smart vector drives installed in new machines include a cover, and the machines electrical cabinet door is
cut to accommodate it. Service drives are shipped without the cover for installation in older machines. When
replacing a drive in a machine built to accommodate the cover, use the cover from the old drive.
When installing a smart vector drive without the cover, install the cover plate to the front of the vector drive.
When installing with the cover, install the cover plate to the top of the vector drive.
You will also need several cables. Please see 93-32-5558A for the 40 HP drive and 93-32-5559A for the 20
HP drive.
PCB REPLACEMENT
Please read this section in its entirety before attempting to replace any PCBs
MICROPROCESSOR ASSEMBLY
The microprocessor assembly is in the control cabinet at the top left position. It contains three large boards.
They are: Microprocessor, the Video/Keyboard and the MOCON. All three boards of the processor assembly
receive power from the low voltage power supply. The three PCBs are interconnected by a local buss on dual
50-pin connectors. At power-on, some diagnostic tests are performed on the processor assembly and any
problems found will generate Alarms 157 or 158. In addition, while the control is operating, it continually tests
itself and a self test failure will generate Alarm 152.
MOCON, VIDEO/KEYBOARD, & MICROPROCESSOR
The electrical panel will have residual voltage, even after power has been
shut off and/or disconnected. Never work inside this cabinet until the small
red Charge light on the servo amplifi ers go out. The servo amplifi ers are on
the left side of the main control cabinet and about halfway down. This light
is at the top of the circuit card at the center of the assembly. Until this light
goes out, there are dangerous voltages in the assembly even when power
is shut off.
WARNING!
96-0284 rev F January 2009
Electrical Service
17
Ground straps must be used when handling boards.
NOTE: Board arrangement may differ from the order of replacement that follows. Steps for
replacement will only differ in which board may need to be removed before getting
to the necessary board.
MOTOR CONTROLLER (MOCON)
Machines are equipped with a microprocessor-based brushless motor controller board (MOCON) that
replaces the motor interface in the brush type controls. It runs in parallel with the main processor, receiving
axis commands and closing the loop around the axis motors.
In addition to controlling the axis and detecting axis faults, the motor controller board (MOCON) is also in
charge of processing discrete inputs, driving the I/O board relays, commanding the spindle, and processing
the jog handle input. It also controls 6 axes, so there is no need for an additional board for a 5-axis machine.
Four LEDs are used to diagnose MOCON problems:
The RUN” LED will turn on, indicating that Mocon code was found in ROM and is being executed. This LED
will turn off if a processor exception causes the Mocon code to abort execution.
The “STAT” LED indicates the following (Specifi c to Mocon 11.00 or later software)
a. Continuously ON - Normal status. board passed all power-on tests; no problems encountered
b. Blinks 3 times - Communication with main processor failed
c. Blinks 4 times - Internal ±12V testing failed
d. Blinks 5 times - Internal watchdog circuit failed
e. Blinks rapidly - EPROM CRC failed
The “Halt” LED glows when the board is in use (processing).
The “+5” LED lights when the board has power.
MOCON Board Replacement
1. Turn machine power off and turn the main switch (upper right of electrical cabinet) to the off position.
2. Open the cabinet door enough to safely work on the electrical panel. Wait until the red charge light on the
servo amplifi ers (servo drive assembly on brush machines) goes out before beginning any work.
3. Disconnect all leads to the Motor Controller (MOCON) board, and ensure all cables are properly labeled.
4. After all cables have been disconnected, unscrew the standoffs, taking care to hold the board in place until
all standoffs have been removed.
NOTE: If the Video/Keyboard or Processor boards need replacing, skip the next step.
5. Replace the MOCON board, attaching it to the Video/Keyboard (beneath the MOCON board) with the
standoffs, and reconnect all leads (previously removed) to their proper connections.
6. If a second MOCON board is present, be sure to connect the jumper on the second MOCON board.
VIDEO/KEYBOARD
The Video/Keyboard PCB generates the video data signals for the monitor and the scanning signals for the
keyboard. In addition, the keyboard beeper is generated on this board. There is a single jumper on this board
used to select inverse video. The video PCB connectors are:
P1 Power connector J11 SPARE
J3 Keyboard (700) J12 Floppy J4 Address bus J13 Video (760)
J5 Data J14 RS422 B J10 Floppy V+ J15 RS422 A
18
Electrical Service
96-0284 rev F January 2009
Video/Keyboard Replacement
1. Remove the MOCON board as previously described.
2. Disconnect all leads to the Video/Keyboard. Ensure all cables are properly labeled for reconnecting later.
3. After all cables have been disconnected, unscrew the standoffs, taking care to hold the board in place until
all standoffs have been removed.
NOTE: If the Processor board needs replacing, skip the next step.
4. Replace the Video/Keyboard, attaching it to the Processor board with the standoffs.
5. Reconnect all leads (previously removed) to their proper connections.
6. Replace the MOCON board.
MICROPROCESSOR PCB (68ECO30)
The Microprocessor PCB contains the 68ECO30 processor running at 40 MHz, one 128K EPROM; between
1MB and 16MB of CMOS RAM and betwen 512K and 1.5MB of Fast Static RAM. It also contains a dual serial
port, a battery to backup RAM, buffering to the system buss, and eight system status LED’s.
Two ports on this board are used to set the point at which an NMI is generated during power down and the
point at which Reset is generated during power down.
The eight LEDs are used to diagnose internal processor problems. As the system completes power up testing,
the lights are turned on sequentially to indicate the completion of a step. The lights and meanings are:
RUN Program Running Without Fault Exception. (Normally On) - If this light does not come on, or goes
out after coming on, there is a problem with the microprocessor or the software running in it. Check all
of the buss connectors to the other two PCBs and ensure all three cards are getting power.
PGM Program Signature Found in Memory. (Normally On) - If this light does not come on, it means that
the main CNC program package was not found in memory, or that the auto-start switch was not set.
Check that Switch S1-1 is on and the EPROM is plugged in.
CRT CRT/LCD Video Initialization Complete. (Normally On) - If the light does not come on, there is a
problem communicating with the Video PCB. Check buss connectors to ensure it is getting power.
MSG Power-on Serial I/O Message Output Complete. (Normally On) - If light does not come on, a
problem exists with serial I/O or interrupts. Disconnect anything on the external RS-232 and retest.
SIO Serial I/O Initialization Complete. (Normally On) - If this light does not come on, there is a problem
with the serial ports. Disconnect anything on the external RS-232 and test again.
POR Power-On-Reset Complete. (Normally On) - If this light does not come on, there is a problem with
the Processor PCB. Check that the EPROM is plugged in. Test the card with buss connectors off.
HALT Processor Halted in Catastrophic Fault. (Normally Dim) - If this light comes on, there is a problem
with the Processor PCB. Check that the EPROM is plugged in. Test the card with buss connectors off.
+5V +5V Logic Power Supply is Present. (Normally On) - If this light does not come on, check the low
voltage power supply and check that all three phases of 230V input power are present.
There is 1 two-position DIP switch on the Processor PCB labled S1. Switch S1-1 must be ON to auto-start the
CNC operational program. If S1-1 is OFF, the PGM light will remain off. Switch S2-1 is used to enable Flash.
If it is disabled it will not be possible to write to Flash.
The processor connectors are:
J1 Address buss J5 Serial port #2 (for auxiliary 5th axis) (850A)
J2 Data buss J3 Power connector
J4 Serial port #1 (for upload/download/DNC) (850) J6 Battery
96-0284 rev F January 2009
Electrical Service
19
Memory Retention Battery
The memory retention battery (3.3V Lithium battery) is soldered into the Processor PCB. It maintains the
contents of CMOS RAM during power off periods. A minimum voltage of 2.5V DC is required for proper
operation. Prior to this battery being unusable, an alarm is generated indicating low battery. If the battery
is replaced within 30 days, no data is lost. The battery is not needed when the machine is powered on.
Connector J6 on the Processor PCB can be used to connect an external battery.
To replace the battery, the 4-pin jumper, attached to a fresh battery, has to be temporarily attached to J6
before the old battery is removed. With the jumper in place, un-solder the old battery and remove. Install a
new battery and solder in place, then remove the temporary jumper.
NOTE: Do not attach the jumper after the old battery has been removed or remove the
jumper if a fresh battery has not been installed. This will result in complete
machine memory loss, which cannot be reversed.
Processor Board Replacement
1. Remove the MOCON board, and the Video/Keyboard as previously described.
2. Disconnect all leads to the Processor board. Ensure all cables are properly labeled for reconnecting later.
3. After all cables have been disconnected, unscrew the standoffs, taking care to hold the board in place until
all standoffs have been removed.
4. Replace the Processor board, attaching it to the electrical cabinet with the standoffs, reconnect all leads
(previously removed) to their proper connections, and replace Video/Keyboard and MOCON board.
INPUT/OUTPUT ASSEMBLY
The Input/Output Assembly consists of a single printed circuit board called the I/O PCB.
The I/O PCB also contains a circuit for sensing a ground fault condition of the servo power supply. If more
than 1.75 amps is detected fl owing through the grounding connection of the 160V DC buss, a ground fault
alarm is generated and the control will turn off servos and stop.
Relay K6 is for the coolant pump 230V AC. It is a plug-in type and is double-pole. Relays K9 through K12 are
also plug-in types for controlling the tool changer motors.
I/O Board Replacement
1. Follow all precautions noted previously before working in the electrical cabinet.
2. Disconnect all leads to the Input/Output board and move aside for removal. Ensure all cables are properly
labeled for reconnecting later.
3. Remove the board by fi rst removing the twelve screws that fasten it to the cabinet. Take care to hold the
board in place until all screws have been removed.
4. Replace the I/O board, attaching it to the cabinet with the twelve screws previously removed, and reconnect
all leads to the I/O board. Check for any additional jumper settings per I/O release notes.
POWER TRANSFORMER ASSEMBLY (T1)
The power transformer assembly converts three-phase input power (50/60Hz) to three-phase 230V and
115V power. Two transformers are used, depending on the input voltage range. The low voltage transformer
has four input connections to allow for a range of voltages from 195V RMS to 260V RMS. The high voltage
transformer has fi ve input connections and will accept a range of voltages from 354V RMS to 488V RMS.
The 230V is used to power the spindle drive. THe 230V also supplies the power to the vector drive, which
supplies 325V DC power for the axis servo amplifi ers. The 115V is used by the video monitor, solenoids, fans
and pumps, in addition to supplying power to the main LVPS used by the control electronics.
20
Electrical Service
96-0284 rev F January 2009
The transformer assembly is located in the lower right hand corner of the main cabinet. Besides the high/low
voltage variations, two different power levels are available depending on the spindle motor used. The small
and large transformers have power ratings of 14 KVA and 28 KVA, respectively, and are protected by the main
circuit breaker.
Ouput
Power
Input
Power
TB2
240VOUT
488-458V
457-429V
260-244V
D
A
INCOMINGLINE VOLTAGETAPS (74,75, 76)
N
428-403V
G
E
243-227V
R
!
!
402-377V
!
H
226-211V
I
G
TB1
120VOUT
376-354V
H
V
210-195V
O
L
T
A
G
E
D
A
N
G
E
R
!
!
!
.
Polyphase Bank Transformer
Primary Connection To T1
Input power to T1 is supplied through CB1, the main circuit breaker. Three-phase 230 to T1 is connected to
the fi rst three terminals of TB10.
Circuit breaker CB1 protects the spindle drive and shuts off all power to the control. A trip of this breaker
indicates a serious overload problem and should not be reset without investigating the cause of the trip.
Main Contactor K1
Main contactor K1 is used to turn the control on and off. The Power On switch applies power to the coil of K1
and after it is energized, auxiliary contacts on K1 continue to apply power to the coil. The Power Off switch on
the front panel will always remove power from this contactor.
When the main contactor is off, the only power used by the control is supplied through two ½ amp fuses to
the circuit that activates the contactor. An overvoltage or lightning strike will blow these fuses and shut off the
main contactor.
The power to operate the main contactor is supplied from a 24V AC control transformer that is primary fused
at ½ amp. This ensures that the only circuit powered when the machine is turned off is this transformer and
only low voltage is present at the front panel on/off switches.
Voltage Selection Taps
There are four labeled plastic terminal blocks. Each block has three connections for wires labeled 74, 75, and
76. Follow the instructions printed on the transformer.
Secondary Connection To T1
The secondary output from T1 is 115V AC three-phase CB2 that protects the secondary of transformer T1 and
is rated at 25 amps.
The low voltage control transformer, T5, supplies power to the coil of the main contactor K1. It guarantees that
the maximum voltage leaving the Power Supply assembly when power is off is 12V AC to earth ground. It is
connected via P5 to the Power PCB.
Operator’s Work Light
Main transformer (T1) outputs 115V AC to the work light.
POWER SUPPLY ASSEMBLY
All control power passes through a power supply assembly on the upper right corner of the control cabinet.
Power PCB (PSUP)
Low voltage power distribution and high voltage fuses and circuit breakers are mounted on a circuit board
called the Power PCB.
Secondary Circuit Breakers
The following circuit breakers are located on the Power supply assembly:
CB2Controls the 115V power from the main transformer to the I/O PCB and, if tripped, will turn off all
inputs and outputs. CB2 could be tripped by a short circuit in the cables.
CB3Controls the power to coolant pump only. It can be tripped by an overload of the coolant pump
motor or a short in the wiring to the TSC motor, or lathe hydraulic pump.
CB4 Controls the power to chip conveyor only.
CB5 Controls power to the TSC coolant pump only. It can be tripped by an overload of the TSC coolant
pump motor or a short in the wiring to the motor.
CB6 Single-phase 115V protected ground fault interrupt circuit and output for the worklight.
Power PCB (PSUP) Replacement
1. Follow all precautions noted previously before working in the electrical cabinet
2. Disconnect all leads to the Power PCB (PSUP) and set aside for removal. Ensure all cables are properly
labeled for reconnecting later.
3. After all cables have been disconnected, remove the seven screws holding the Power board to the cabinet
and remove the board. Take care to hold the Power board in place until all screws have been removed.
NOTE: If replacing the Low Voltage Power Supply board, please skip the next step.
4. Replace the Power board, attaching it with the seven screws previously removed. Do not forget to use the
lower left screw for a ground connection.
5. Reconnect all cables to Power board at proper location. Refer to release notes for additional information.
LOW VOLTAGE POWER SUPPLY
The low voltage power supply provides +5V DC, +12V DC, and -12V DC to all logic sections of the control. It
operates from 115V AC nominal input power, and continues to operate correctly over 90 to 133V AC.
Low Voltage Power Supply (LVPS) Replacement
1. Remove the Power Distribution (Power) board as previously described.
2. Disconnect all leads to the Low Voltage Power Supply (LVPS) board. Ensure all cables are properly labeled
for reconnecting later.
3. After all cables are disconnected, unscrew the two standoffs at the bottom of the board. Unscrew the
remaining two screws at the top of the LVPS board. Hold the board in place until all screws are removed.
4. Replace the LVPS board, attaching it to the cabinet with the two screws and standoffs previously removed.
5. Replace the Power board as previously described.
22
Electrical Service
96-0284 rev F January 2009
RS-232 SERIAL INTERFACE
There are two connectors used for the RS-232 interface. The RS-232 connector on most PCs is a male DB25, so only one type of cable is required for connection to the controller, or between controllers. This cable
must be a DB-25 male on one end and a DB-25 female on the other. Pins 1, 2, 3, 4, 5, 6, 7, 8, and 20 must
be wired one-to-one. It cannot be a Null Modem cable, which inverts pins 2 and 3. To check cable type use
a cable tester to check that communication lines are correct. The controller is DCE (Data Communication
Equipment). This means that it transmits on the RXD line (pin 3) and receives on the TXD line (pin 2). The
RS-232 connector on most PCs is wired for DTE (Data Terminal Equipment), requiring no special jumpers.
The Down Line DB-25 connector is only used when more than one controller is to be used. The fi rst
controller’s down line connector goes to the second controller’s up line connector, etc.
Interfacing a Haas Rotary Control to the mill
The RS-232 interface sends and receives seven data bits, even parity, and two stop bits. The interface must
be set correctly. The data rate can be between 110 and 19200 bits per second. When using RS-232, it is
important to make sure that Parameter 26 (RS-232 Speed) and 33 (X-on/X-off Enable) are set to the same
value in the controller and PC.
If Parameter 33 is set to on, the controller uses X-on and X-off codes to control reception, so be sure your
computer is able to process these. It also drops CTS (pin 5) at the same time it sends X-off and restores CTS
when is sends X-on. The RTS line (pin 4) can be used to start/stop transmission by the controller or the X-on/
Xoff codes can be used. The DSR line (pin 6) is activated at power-on of the controller and the DTR line (pin
20 from the PC) is not used. If Parameter 33 is 0, the CTS line can still be used to synchronize output.
When more than one Haas controller is daisy-chained, data sent from the PC goes to all of the controllers at
the same time, requiring an axis selection code (Parameter 21). Data sent back to the PC from the controllers
is ORed together so that, if more than one box is transmitting, the data will be garbled. Because of this, the
axis selection code must be unique for each controller.
RS-232 Remote Command Mode
Parameter 21 must be non-zero for the remote command mode to operate as the controller looks for an axis
select code defi ned by this parameter. The controller must also be in RUN mode to respond to the interface.
Since the controller powers-on in Run mode, remote unattended operation is thus possible.
RS-232 Line Noise
To minimize line noise on the serial port, reroute the cables straight up the left-hand side of the control to the
processor stack. Do not run them above the I/O PCB or up the center wire channel to the processor.
Transmission errors may be best minimized with a good common ground between the PC and CNC control.
RS-232 Loop Back Test
If you have a communications problem between Port #1 of the machine and your external computer, use the
following procedure to isolate the problem to either internal or external causes.
1. Unplug the cable from Port #1 of the Control Panel, and plug the cable tester in (port #1).
PLUG TESTER
BACK VIEW
The RS-232 Plug Tester is a 25-pin male connector with the following pins shorted.
Pins 2 & 3 and Pins 14 & 16
In order to properly perform the test, Setting 14 must be set to CTS/RTS.
96-0284 rev F January 2009
Electrical Service
23
2. If the machine is on, cycle the power (power down then turn back on).
3. Press List Prog, followed by press Param Dgnos twice, then press Send RS232.
4. If the internal serial port is working, the lower left-hand part of the screen will display Serial Passed. (This
means that the system, to the output of the control panel, is working. Check the cable to the computer
set-up if you still have a communications problem.)
If the internal serial port is bad, the lower left-hand part of the screen will display Serial Failed. (This means
there is a problem inside the control panel, or that the test connector is unplugged or missing.)
RS-232 PCB Replacement
1. Follow all precautions noted previously before working in the electrical cabinet.
NOTE: It is necessary, when replacing the RS-232 board, to work from the inside and
outside of the cabinet at the same time.
2. On the left side of the cabinet, at the top of the side panel, are two serial port connections labeled “Serial
Port #1” and “Serial Port #2”. Serial Port #1 is the upper connection.
5
1
2
3
4
R
R
R
R
R
V
V
V
V
V
RS-232
PORT 1
RS-232
PORT 2*
2
1
P
P
5R
4
R
3R
2R
1
R
PIN1
2
3
4
5
1
C
C
C
C
C
D
N
3
P
G
Video &
Keyboard
J13
Processor
J14
* Requires second RS-232 Board (34-4089)
RS-232
PCB
Micro
SKBIF
P1
J4
PORT 1
To
RS-232
PORT 2*
* Requires second RS-232 Board (34-4090)
RS-232 Wiring Diagram (with Serial Keyboard)
5
1
2
3
4
R
R
R
R
R
V
V
V
V
V
2
1
P
P
5
R
4
R
3
R
2R
1
R
PIN1
2
3
4
5
1
C
C
C
C
C
D
N
3
P
G
J3
Coldfire
Micro
Processor
J4
J14
3. To remove the RS-232 board, unscrew the two hex screws (on the exterior of the cabinet) holding the
connector to the cabinet. From the inside of the cabinet, pull the connector through the panel, and disconnect
the cable.
4. Replace the RS-232 board by fi rst connecting the appropriate cable to the board (850 to Serial Port #1,
850A to Serial Port #2, then inserting the board (cable side up) through the left side panel. Attach with the two
hex screws previously removed. Ensure the board for Serial Port #1 is the upper connector and the board for
Serial Port #2 is the lower connector.
To
SKBIF
P1
24
Electrical Service
96-0284 rev F January 2009
SPARE USER M CODE INTERFACE
The M code interface uses outputs M21-25 and one discrete input circuit. M codes M21 through M25 will
activate relays labeled M21-25. These relay contacts are isolated from all other circuits and may switch up to
120V AC at three amps. The relays are SPDT (Single Pole Double Throw).
Power circuits and inductive loads must have snubber protection.
The M-FIN circuit is a normally open circuit that is made active by bringing it to ground. The one M-FIN
applies to all of the user M codes.
The timing of a user M function must begin with all circuits inactive (open). The timing is as follows:
WARNING!
M21
M-FIN Discrete
Input 1009
CNC is:
RunningWaiting
for M-fin
.05 ms
delay
Waiting for
end M-fin
Running
The Diagnostic Data display page may be used to observe the state of these signals.
M FUNCTION RELAYS (M-FIN)
The I/O PC board has relays that are available to the user. M21 is already wired out to P12 at the side of the
control cabinet. This is a four-pin DIN connector and includes the M-FIN signal.
NOTE: Refer to Diagnostic Data for specifi c machine Inputs and Outputs.
3
M-Code
Output Relay
Normally Open
4
1 M-FIN, Input Signal
2 Input GND
NOTE: Some or all of the M21-25 on the I/O PCB may be used for factory installed options.
Inspect the relays for existing wires to determine which are in use.
M-FIN DISCRETE INPUT
The M-FIN discrete input is a low voltage circuit. When the circuit is open, there is +12V DC at this signal.
When the line is brought to ground, there is about 10 milliamps of current. M-FIN is discrete input 1009
and is wired from input 1009 on the I/O PCB (usually P10). The return line for grounding the circuit should
come from that PCB. For reliability, these two wires should be routed in a shielded cable where the shield is
grounded at one end only. The diagnostic display shows a “1” when the circuit is open and a “0” when it is
grounded.
WIRINGTHE RELAYS
Relays are marked on the I/O PCB, with their respective terminals forward of them. If the optional 8M relay
board is installed, connections on the I/O PCB are unused, since they are replaced by relays on the optional
board. Refer to the fi gure, and the Probe Option fi gure in the Electrical Diagrams section for terminal labeling.
96-0284 rev F January 2009
Electrical Service
25
SWITCHES
X, Y, Z Travel Limit Switches
Machine zero position is defi ned by a limit switch for each of the X, Y, and Z axes. After search for machine
zero is complete, these switches are used to limit travel in the positive direction. Negative direction travel is
limited by stored stroke limits. It is not normally possible to command the servo axes past the machine zero
as servo travel lookahead will decelerate and stop each motor prior to exceeding the stroke limits.
Prior to performing a Power Up/Restart or an Auto All Axes operation, there are no travel limits. You can jog
into the hard stops in either direction for X, Y, or Z. After a Zero Return has been performed, the travel limits
will operate unless an axis hits the limit switch. When the limit switch is hit, the zero returned condition is reset
and an Auto All Axes must be done again to ensure you can still move the servo back away from it.
The limit switches are normally closed. When a search for zero operation is being performed, the X, Y, and Z
axes will move towards the limit switch unless it is already active (open); then move away from the switch until
it closes again; then continue to move until the encoder Z channel is found. This position is machine zero.
On some mills, the auto search for zero in the Z-axis is followed by a rapid move from the limit switch position
down to the tool change position, making the Z-axis a little different from the other axes. The position found
with the limit switch is not machine zero but is the position used to pull tools out of the spindle. Machine zero
for Z is below this by Parameter 64. Be careful during the Z zero search and stay clear of that rapid move.
What Can Go Wrong With Switches?
Proximity switches are distance sensitive, and must be set no farther than .012” (3mm) away from an
assembly or limit fl ag. An improperly set proximity switch will give inconsistence results, which may be
interrupted as another problem. Any time a switch is replaced ensure the proper distance is set.
• If the machine is operated with Limit Switch inputs disabled, a Low Lube and Door Open alarm is generated.
In addition, Home search will not stop at the limit switch and instead runs into the physical stops on each axis.
• If the switch is damaged and permanently open, the zero search for that axis will move in the negative
direction at about 0.5 in/min until it reaches the physical travel stops at the opposite end of travel.
• If the switch is damaged and permanently closed, the zero search for that axis will move at about 10 in/min
in the positive direction until it reaches the physical stops.
• If the switch opens or a wire breaks after the zero search completes, an alarm is generated, the servos are
turned off, and all motion stops. The control will operate as though the zero search was never performed.
Reset can be used to turn servos on, but you can jog that axis slowly.
Clamp/Unclamp Switches
There are two switches used to sense the position of the turret or tool clamping mechanism. They are both
normally closed and one will activate at the end of travel during unclamping and the other during clamping.
When both switches are closed, it indicates that the turret or drawbar is between positions.
The diagnostic display can be used to display the status of the relay outputs and the switch inputs.
Door Hold Switch
The switch is normally closed. When the door opens, the switch opens and the machine stops with a “Door
Hold” function. When the door is closed again, operation continues normally.
If the door is open, it is not possible to start a program. Door hold will not stop a tool change operation, will not
turn off the spindle, and will not turn off the coolant pump. The door hold function can be temporarily disabled
with Setting 51, but this setting will return to Off when the control is turned off.
Tool #1 Sense Switch
The tool rotation turret has a switch activated when tool one is in position or facing toward the spindle. At
Power On this switch can indicate that tool #1 is in the spindle. If this switch is not active at power-on, the fi rst
tool change will rotate the turret until the switch engages and then move to the selected tool. The diagnostic
display will show the status of this input switch as “Tool #1”. A “1” indicates that tool #1 is in position.
26
Electrical Service
96-0284 rev F January 2009
Umbrella Tool Changer Geneva Wheel Position Mark (Vert)
The turret rotation mechanism has a switch mounted so that it is activated for about 30o of travel of the
Geneva mechanism. When activated, this switch indicates that the turret is centered on a tool position. This
switch is normally closed. The diagnostic display will show this status of this input switch as “TC MRK”. A “1”
indicates the Geneva wheel is in position.
Two switches are used to sense the position of the tool changer shuttle and the arm that moves it. One switch
is activated when the shuttle is moved to full travel inward and one is activated when it is in full travel outward.
These switches are normally closed, so that both are closed between in and out. The diagnostic display will
show the status of the input switch. A “1” indicates the associated switch is activated or open.
Transmission High/Low Gear Position Switches
On machines with a two-speed transmission, there are two switches in the gearbox used to sense the position
of the gears. One switch indicates “High” by opening and the other indicates “Low” by opening. Between
gears, both switches are closed, indicating a between-gear condition. The diagnostic display shows the status
of these switches and the Curnt Comds display shows which gear is selected. If the switches indicate that the
gearbox is between gears, the display will indicate “No Gear”.
NOTE: The Transmission High/Low Gear Position Switches are located at the bottom of the
CONTROL MEMORY
The Haas processor board contains three types of memory:
Gearbox Assembly and are diffi cult to reach. Removal of this assembly is necessary
to replace these switches. See the Mechanical Components Service Manual, for
Spindle Motor and Transmission removal.
• Flash Memory - stores the binary and language fi les (software). Information stored only changes when the
serviceperson loads a new binary fi le. Flash memory retains its contents even when the power is turned off.
• Random Access Memory (RAM) - When the machine is powered up the processor board copies the binary
fi le and the selected language text from the fl ash memory into RAM, which is run from there. RAM also holds
internal information that the control needs while it is running, such as current position, displays screens, etc.
When the user selects a different language, it is copied over the last language. Information stored in RAM is
not retained when the machine is turned off.
• Battery Backed-up Random Access Memory (BBU-RAM) - This type of memory uses an on-board
battery to retain its information after the machine is turned off. If battery power is low the memory gets
corrupted, and if the battery voltage goes to zero, the memory goes blank. Battery Backed up memory holds
information such as user programs, Settings, Parameters, Offsets.
Clearing Processor Memory (Coldfi re):
At the prompt, >, type in the following and press, “enter” to test and clear BBU Ram:
M 6000000 60FFFFF
The following message is repeatedly displayed until Reset is pressed to stop the BBU RAM memory test:
Memory test passed, press and hold reset to stop
To clear Flash Memory (Coldfi re Processor):
Type “FC” and press enter
The following message will be displayed:
ERASING FLASH – PLEASE WAIT…
FIRST FLASH CHIP ERASED
FLASH CLEAR COMPLETE
NOTE: This fl ash memory clear will not erase the ColdFire monitor program
96-0284 rev F January 2009
Electrical Service
27
Clearing the memory in a control
At times it is necessary to clear the memory of the machine. This may have to be done to update software, or
do remove corrupted software. To do this follow the steps for the specifi c type of memory. The next two steps
must be followed to prepare the machine.
1. The programs, settings and other control information must be saved before clearing the memory. It may be
necessary to turn off Setting 23 to save the macro variables. The following are the fi les to save:
2. Turn off the machine and then turn it back on while holding the PRGRM CONVRS button. The display will
be similar to the following:
HAAS 68030 MONITOR ddd-mmm-yy
FLASH MEMORY FOUND: 1024K @ 00080000
BBU RAM FOUND: 1024 K (1024K of BBU-RAM)
68882 COPROCESSOR NOT FOUND
This example shows 1024K of fl ash memory at address 80000 and 1024K of BBU-RAM. Write down what the
machine has before continuing.
Clearing the BBU-RAM (68K Processor)
1. Type in “M 3000D6C 300FFFF” and press Enter. The control responds with “Memory Test Passed” written
several times. The command “M3000D6C” checks and clears just a portion of the BBU-RAM. It avoids the
section that contains the serial number of the machine (Setting 26). Most problems can be solved without
removing the serial number.
2. Press and Hold Reset until you see “>” displayed. If the “>” does not display, continue to step 3.
3. This step will clear the BBU-RAM completely including the machine serial number. Use the following to
determine the command to clear BBU-RAM.
BBU RAM Found Board Size Command to Clear BBU-RAM
256K 256K M 3000000 303FFFF
1024K 1 megabyte M 3000000 30FFFFF
4096K 4 megabyte M 3000000 33FFFFF
8192K 8 megabyte M 3000000 37FFFFF
16384K 16 megabyte M 3000000 3FFFFFF
To Clear BBU- RAM as per the example, Type the following and press Enter:
M 3000000 30FFFFF (for 1024K)
Clearing Flash Memory:
Clearing Flash Memory will solve problems caused by fragments of code left behind from previous binary or
language fi les. The most common problem is BAD LANGUAGE VERSION alarm. To clear the fl ash memory,
a value is entered to tell the system where it is located. Following these steps will clear the memory or give
you the message, “Undefi ned Command”, or a similar message.
If the control displayed the amount of fl ash memory in step 2 of “Clearing the memory in the control”, then do
one of the following depending upon how much fl ash Memory is found:
Enter FC 80000 200000 and press enter (for 1536K of FLASH)
Enter FC 80000 280000 and press enter (for 2048K of FLASH)
Enter FC 80000 380000 and press enter (for 3072K of FLASH)
Enter FC 8000 and press enter (for 0.5MB of FLASH)
Enter FC 100000 and press enter (for 1.0MB of FLASH)
Enter FC 180000 and press enter (for 1.5MB of FLASH)
28
Electrical Service
96-0284 rev F January 2009