No part of this manual may be reproduced or transmitted in any form or by any means
without prior written consent of Hangzhou Huawei-3Com Technology Co., Ltd.
Trademarks
H3C, Aolynk, , IRF, H3Care,
SecPath, COMWARE, VVG, V2G, VnG, PSPT, NetPilot, and XGbus are trademarks of
Hangzhou Huawei-3Com Technology Co., Ltd.
All other trademarks that may be mentioned in this manual are the property of their
respective owners.
Notice
The information in this document is subject to change without notice. Every effort has
been made in the preparation of this document to ensure accuracy of the content s, but
all statements, information, and recommendations in this document do not constitute
the warranty of any kind, express or implied.
To obtain the latest information, please access:
http://www.huawei-3com.com
1 Regulatory Compliance Statement Lists the regulatory compliance
2 Regulatory Compliance Information Covers the details of regulatory
3 Safety Information Provides the safety information in
statements of H3C S7500 Series
Ethernet Switches.
compliance information, including
regulatory compliance standards for the
switch, USA regulatory compliance,
European Directives compliance, and
CISPR 22 requirements.
English, comprising general warning,
warnings on installation, and safety with
electricity. You are expected to read this
chapter very carefully before installing
the equipment.
Conventions
The manual uses the following conventions:
I. Command conventions
4 安全信息
5 Sicherheitsinformationen Provides the safety information in
Convention Description
Boldface
The keywords of a command line are in Boldface.
Provides the safety information in
Chinese, comprising general warning,
warnings on installation, and safety with
electricity. You are expected to read this
chapter very carefully before installing
the equipment.
German, comprising general warning,
warnings on installation, and safety with
electricity. You are expected to read this
chapter very carefully before installing
the equipment.
Convention Description
italic
[ ]
{ x | y | ... }
[ x | y | ... ]
{ x | y | ... } *
[ x | y | ... ] *
# A line starting with the # sign is comments.
Command arguments are in italic.
Items (keywords or arguments) in square brackets [ ] are
optional.
Alternative items are grouped in braces and separated by
vertical bars. One is selected.
Optional alternative items are grouped in square brackets
and separated by vertical bars. One or none is selected.
Alternative items are grouped in braces and separated by
vertical bars. A minimum of one or a maximum of all can be
selected.
Optional alternative items are grouped in square brackets
and separated by vertical bars. Many or none can be
selected.
II. GUI conventions
Convention Description
< >
[ ]
/
Button names are inside angle brackets. For example, For
example, click <OK>.
Window names, menu items, data table and field names
are inside square brackets. For example, pop up the [New
User] window.
Multi-level menus are separated by forward slashes. For
example, [File/Create/Folder].
III. Symbols
Convention Description
Means reader be extremely careful. Improper operation
Warning
Caution
Note Means a complementary description.
may cause bodily injury.
Means reader be careful. Improper operation may cause
data loss or damage to equipment.
Environmental Protection
This product has been designed to comply with the requirements on environmental
protection. For the proper storage, use and disposal of this product, national laws and
regulations must be observed.
Compliance and Safety Manual
H3C S7500 Series Ethernet Switches Table of Contents
5.5.4 Zusammenlegen von Signalleitungen...................................................................5-10
ii
Compliance and Safety Manual
H3C S7500 Series Ethernet Switches List of Figures
List of Figures
Figure 1-1 European Community CE Certification DoC of H3C S7502.................................1-1
Figure 1-2 European Community CE Certification DoC of H3C S7502 and H3C S7503-DC1-2
Figure 1-3 European Community CE Certification DoC of H3C S7506 and H3C S7503-DC1-3
Figure 1-4 European Community CE Certification DoC of H3C S7506R and H3C S7506R-DC
Table 5-1 Sicherheitssymbole und Beschreibung..................................................................5-2
iv
Compliance and Safety Manual
H3C S7500 Series Ethernet Switches Chapter 1
Regulatory compliance statement
Chapter 1 Regulatory compliance statement
1.1 European Community CE Certification DoC
Figure 1-1 European Community CE Certification DoC of H3C S7502
1-1
Compliance and Safety Manual
H3C S7500 Series Ethernet Switches Chapter 1
Regulatory compliance statement
Figure 1-2 European Community CE Certification DoC of H3C S7502 and H3C
S7503-DC
1-2
Compliance and Safety Manual
H3C S7500 Series Ethernet Switches Chapter 1
Regulatory compliance statement
Figure 1-3 European Community CE Certification DoC of H3C S7506 and H3C
S7503-DC
1-3
Compliance and Safety Manual
H3C S7500 Series Ethernet Switches Chapter 1
Regulatory compliance statement
Figure 1-4 European Community CE Certification DoC of H3C S7506R and H3C
S7506R-DC
1-4
Compliance and Safety Manual
H3C S7500 Series Ethernet Switches Chapter 2 Regulatory Compliance Information
Chapter 2 Regulatory Compliance Information
2.1 Regulatory compliance standards
Table 2-1 Regulatory compliance standards
Discipline Standards
FCC Part 15 (CFR 47) Class A
CISPR22 Class A
EN55022 Class A
ETSI EN 300 386 V1.2.1
EMC
VCCI Class A
AS/NZS 3548 Class A
EN55024
IEC 61000-3-2
IEC 61000-3-3
UL 60950
IEC 60950
Safety
EN 60950
EN60825-1: and EN60825-2:
AS/NZS 3260
CSA C22.2 No 60950
2.2 European Directives compliance
H3C S7500 Series Ethernet Switches comply with the following European Directives:
89/336/EC (electromagnetic compatibility), 73/23/EC (low voltage) or 99/5/EC.
See Figure 1-1 to 1-4 for Huawei-3Com-3Com's Declaration of Conformity.
2.3 USA regulatory compliance
2.3.1 FCC Part 15
H3C S7500 Series Ethernet Switches comply with Part 15 of the FCC Rules. Operation
is subject to the following two conditions:
z This device may not cause harmful interference.
z This device must accept any interference received, including interference that may
cause undesired operation.
2-1
Compliance and Safety Manual
H3C S7500 Series Ethernet Switches Chapter 2 Regulatory Compliance Information
If the customer modifies the equipment without the authorization of Huawei-3Com,
which directly or indirectly contribute to the equipment incompliance with FCC
requirements for Class A digital devices, Huawei-3Com is not liable for such
interference problem and the expenses incurred therefrom shall be covered by the
customers.
Note:
This equipment has been tested and found to comply with the limits for a Cla ss A digital
device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide
reasonable protection against harmful interference when the equipment is operated in
a commercial environment. This equipment generates, uses, and can radiate radio
frequency energy and, if not installed and used in accordance with the instruction
manual, may cause harmful interference to radio communications. Operation of this
equipment in a residential area is likely to cause harm ful interference in which case the
user will be required to correct the interference at his own expense.
2.3.2 FDA
H3C S7500 series Ethernet Switches conform to the applicable requirements of 21
CFR Subchapter J.
2.4 Japan regulatory compliance
2.4.1 VCCI
H3C S7500 series Ethernet Switches comply with the requirements of VCCI Class A
Information Technology Equipment (ITE).
Warning: If this equipment is used in a domestic environment, radio disturbance may
arise. When such trouble occurs, the user may be required to take corrective actions.
2.5 CISPR 22 compliance
H3C S7500 series Ethernet Switches comply w ith the requirements of CISPR 22 for
Class A Information Technology Equipment (ITE).
Warning: If this equipment is used in a domestic environment, radio disturbance may
arise. When such trouble occurs, the user may be required to take corrective actions.
2-2
Compliance and Safety Manual
H3C S7500 Series Ethernet Switches Chapter 3 Safety Information
Chapter 3 Safety Information
3.1 Overview
This section introduces part of the safety precautions that sh ould be followed during the
installation and maintenance of the equipment of Huawei-3Com.
Note:
Before any operation is performed, please read the operation instructions and
precautions carefully to minimize the possibility of accidents. The Note, Caution, Warning and Danger items in other manuals do not cover all safety precautions that
should be followed. They are only the supplements to the safety precautions for
operations as a whole. Therefore, the personnel in charge of the installation and
maintenance of the Huawei-3Com products are required to understand these basics o f
safety operation .
In performing various operations, please follow the local safety regulations. The safety
precautions introduced in the product manuals are supplementary and subject to the
local safety regulations.
When various operations are executed on the Huawei-3Com products, the precautions
and special safety instructions provided by Huawei-3Com must be followed to the full.
The personnel in charge of the installation and maintenance of the Huawei-3Com
products must be trained as professionals to master the proper operating methods and
all safety precautions. Only the trained and qualified personnel can perform operations
such as equipment installation and maintenance.
3.1.1 Conventions Used
The symbols in this manual are shown in the following table. They are used to remind
the reader of the safety precautions during equipment installation and mainte nance.
Table 3-1 Safety symbol and description
Safety Symbol Description
Generic alarm symbol: To suggest a general safety concern
ESD protection symbol: To suggest electrostatic-sensitive
equipment.
3-1
Compliance and Safety Manual
H3C S7500 Series Ethernet Switches Chapter 3 Safety Information
Safety Symbol Description
Electric shock symbol: To suggest a danger of high voltage
Microwave symbol: To suggest a high-intensity
electromagnetic field
Laser symbol: To suggest a strong laser beam
Safety precautions are classified into the following levels: Danger, Warning, Caution
and Note.
Danger: Suggests the possibility of a fatal accident or body injury if safety precautions
are ignored.
Warning: Suggests the possibility of a major accident or severe injury, or equipment
damage, if safety precautions are ignored.
Caution: Suggests the possibility of a severe injury, or that the equipment may be
damaged, if safety precautions are ignored.
Note: Suggests the possibility of an injury or equipment damage, if safety precautions
are ignored
3.1.2 General Requirements
In order to reduce the technically unavoidable residual risk to a minimum, it is
imperative to follow the rules below:
z Read all the instructions before operation.
z When installing the unit, always make the ground connection first and di sconnect it
last.
zDo not block ventilation openings while the system is on, and keep at least 5 cm
distance from ventilation openings and walls or other things which may block the
openings.
zNever defeat the ground conductor or operate the equipment in the absence of a
suitably installed ground conductor. Contact the appropriate electrical insp ection.
zThe unit/system must be connected to the protection ground before operation
permanently. And the cross-section of protective earthing conductor shall be at
2
least 6mm
zFor DC supplied model: Reinforced insulation must be provided to isolate 61-72V
source from the AC mains supply.
zBecause the device has several power supplies, disconnect all of them to switch
off the device.
zWhen moving or lifting the chassis, please use the handles that are directly in the
chassis, or lift the chassis by grasping it s lower edge, and it is not permitted to use
.
3-2
Compliance and Safety Manual
H3C S7500 Series Ethernet Switches Chapter 3 Safety Information
the handles on certain modules such as power supply, fans or cards, for they
cannot support the weight of the device.
zDo not lift the chassis alone, always move it by two people. When lifting it, keep
your back straight and move stably.
zTo prevent laser radiation from hurting your eyes, never stare into the open o ptical
port.
zFor safety it is not recommended to wear jewelry and watch during operation on
device.
zInstallation, configuration and disassembly must be done only by skillful personnel
according to the documents concerned.
z The unit/system must be operated by experts and authorized users only.
z Any replacement or change to the system or parts of the system (including the
software) must be done by qualified or authorized personnel of Huawei-3Com.
zAny fault and error that might affect safety must be reported immediately by the
user to the person in charge.
zRemoval or disabling of safety facilities, troubleshooting, and maintenance of the
equipment must be done by qualified specialists only.
All parts of the document must be followed to the full. The document also serves as a
guide to the selection of measuring and test equipment.
3.2 Electricity Safety
3.2.1 High Voltage
Danger:
High voltage power supply offers electric power for equipment op eration. Direct contact
or indirect contact (via damp objects) with high voltage and AC mains supply may result
in fatal danger.
zDuring the installation of AC power supply facility, the local safety regulations must
be followed. The personnel who install the AC facility must be qualified for high
voltage and AC operations.
zConducting articles, such as watch, hand chain, bracelet and ring are prohibited
during the operation.
zWhen water is found in the rack, or the rack is damp, please immediately switch off
the power supply.
zWhen operation is performed in a damp environment, make sure that water is ke pt
off the equipment.
3-3
Compliance and Safety Manual
H3C S7500 Series Ethernet Switches Chapter 3 Safety Information
Warning:
Non-standard and improper high voltage operations may result in fire and electric
shock. Therefore, AC cable bridging and wiring through a certain area must follow the
local rules and regulations. The personnel who perform high voltage operations should
be qualified for high voltage and AC operations.
3.2.2 Power Cable
Note:
Installation and removal of live power cable is prohibited strictly. Transient contact
between the core of power cable and conductor may generate electric arc or spark,
which may lead to fire or eye injury.
zBefore the power cable is installed or removed, the power switch must be turned
off.
zBefore the power cable is connected, it must be confirmed that the power cable
and label comply with the requirements of the actual installation.
Note:
For DC power supplied equipment, please use 2.5 mm2 or 12 AWG minimum power
supply cord.
2
For AC power supplied equipment, please use 1.0 mm
or 16 AWG minimum power
supply cord.
Use type H03VV-F or light PVC sheathed flexible cord according to IEC 60227.
3-4
Compliance and Safety Manual
H3C S7500 Series Ethernet Switches Chapter 3 Safety Information
3.2.3 Tools
Warning:
During high voltage and AC operations, special tools should b e used. It is not permitted
to use common tools or tools brought by the operator.
3.2.4 Drilling
Warning:
Drilling on the rack without permission is strictly prohibited. Drilling that does not satisfy
the requirements concerned may damage the wires and cables inside the rack. If the
metal swarf from the drilling gets into the rack, it may result in short-circuit of the circuit
boards.
zIf it is necessary to drill a hole on the rack, insulation protection gloves must be
worn, and the cables inside the rack should first be removed.
zDuring the drilling, make sure that the eyes of the operator are well protected. The
spattering swarf may cause injury to the eyes.
z Make sure that the metal swarf does not get into the rack.
z Non-standard drilling operation may damage the electromagnetic shielding
performance of the rack.
zAfter the drilling, please clean up the metal swarf in time.
3.2.5 Thunderstorm
Danger:
High voltage and AC operations, or operations on a steel tower and a mast on a
thunderstorm day are prohibited.
3-5
Compliance and Safety Manual
H3C S7500 Series Ethernet Switches Chapter 3 Safety Information
On a thunderstorm day, the electromagnetic field generated in the thunderstorm area
may cause damage to electronic parts. In order to prevent the equipment from being
damaged by lightning, proper grounding is required.
3.2.6 Electrostatic
Caution:
The electrostatic(static electricity) generated by human body may damage the
electrostatic-sensitive components on the circuit board, such as large-scale integrated
circuit (LSIC).
zIn the case of human body moving, clothes friction, friction between shoes and
ground, holding ordinary plastic in hand, the human body will generate a static
electromagnetic field that will remain with the human body for a long time.
zBefore touching the equipment, hand-holding, circuit boards, or ASICs, a
grounded electrostatic discharge (ESD) wrist strap should be worn to prevent the
sensitive components from being damaged by the electrostatic in human body.
Figure 3-1 Diagram of wearing electrostatic protection wrist strap
3.3 Fuse
For the safety of continuous operation, please replace the fuse with that of the same
type and rating, if necessary.
Warning:
3-6
Compliance and Safety Manual
H3C S7500 Series Ethernet Switches Chapter 3 Safety Information
3.4 Laser
The laser hazard level of this equipment is Class 1.
Warning:
When performing installation and maintenance operations of optical fibers, you should
not stand close to, or look into the optical fiber outlet directly with unaided eyes.
3.4.1 General Laser Information
Laser transceiver/ transmitter are used in optical transmission system and associated
test instruments. The wavelength of the laser is above 780nm, and lower than 1600nm.
Because the laser being transmitted through the optical fiber , produces a small beam of
light,it has very high power density and is invisible to human eyes. When a beam of
light enters the eyes, retinal may be burned.
The damage mechanism at the wavelengths used in telecommunications is thermal in
origin i.e., damage caused by heating. Therefore, a specific amount of energy is
required for a definite time to heat an area of retinal tissue.
Lasers used in lightwave systems have a larger beam divergence, typically 10 to 20
degrees. Inadvertently viewing an un-terminated fiber or damaged fiber with the
unaided eye at distances greater than 150 mm (6 inches) will normally not cause eye
injury. However, damage may occur if an optical instrument such as a microscope,
magnifying glass or eye loupe is used to view the energized fiber end.
In its normal operating mode, a lightwave system is totally enclosed and presents no
risk of eye injury. Additional safety is achieved by the implementation of an Automatic
Laser Shut-down (ALS) of the system. The ALS, however, can be applied for
bi-directional transmission only. If the receiver side does not detect the laser from the
transmission side, it will give the transmission side a signal, so the ALS will shutdown
the laser emission in less than 100ms.
3.4.2 Laser Safety Guidelines
Read the following guidelines to avoid laser radiation:
zRead the relevant instructions before installation, operation and maintenance the
equipment. Ignoring the instructions can cause in exposure to dangerous laser
radiation.
zAn eye-protective glasses are recommended when you are handling lasers or
fibers.
3-7
Compliance and Safety Manual
H3C S7500 Series Ethernet Switches Chapter 3 Safety Information
zAll the operations shall be performed by authorized personnel who satisfactorily
completed an approved training course.
zMake sure that the optical source is switched off before disconnecting optical fiber
connectors.
zBefore opening the front door of an optical transmission system, always take care
that you are not exposed to laser radiation.
zNever look into the end of an exposed fiber or an open connector as long as you
are not sure whether the optical source is switched on or off.
zPlease use optical power meter to check that the optical source is switched off by
measuring the optical power.
zNever use optical instrument such as a microscope, magnifying glass or eye loupe
to view the optical connector or fiber.
3.4.3 Handing Fibers
Read the instructions before handling fibers.
z Cutting and splicing fibers must be performed by trained personnel only.
z Before cutting or splicing the fibers, always verify the fiber is disconnected from
the optical source. After disconnect the fiber, all the optical connectors must be
protected by a protecting cap.
3.5 Miscellaneous
3.5.1 Lifting Heavy Objects
Warning:
When lifting heavy objects, it is prohibited to stand or walk under the arm or the lifted
object.
3.5.2 Sharp Objects
Warning:
When the equipment is carried by hand, protection gloves should be worn to avoid
injury by sharp objects.
3-8
Compliance and Safety Manual
H3C S7500 Series Ethernet Switches Chapter 3 Safety Information
3.5.3 Plug/Unplug Board
Note:
When plugging the board, the operator should not push it too hard; otherwise the pins
on the backplane may be distorted.
zThe board should be inserted along the slot guides. Try to avoid contacts between
the circuit sides of the board and other boards, which will result in short-circuit or
scratch.
zWhen holding a board in hand, do not touch the board circuit, components,
connectors, and connection slots.
3.5.4 Binding Signal Lines
Note:
Signal lines should be bound separately from strong current lines or high voltage lines.
The spacing of the binding should be 150mm at minimum.
3-9
Compliance and Safety Manual
H3C S7500 Series Ethernet Switches
z 在处理光模块或是光纤时,请佩带保护眼镜。
z 所有的操作必须由专业人员进行。
z 在拆装光纤连接器之前,请确保光源已经切断。
z 在打开激光发送系统护罩之前,请确保眼睛不要暴露在激光辐射区域。
z 在不能确定激光光源是关闭还是工作状态时,请不要直视暴露的光纤或是连接器。
z 请使用激光能量测试仪来测试设备的激光能量,检查光源是否关闭。
z 禁止使用光仪器来观察激光连接器或是光纤,如:显微镜、放大镜或是用于珠宝加
工的小型放大镜等。
Chapter 4 安全信息
4.4.3 光接口的处理
在进行光接口处理前,请仔细阅读本手册
z 必须由专业人员进行插拔光纤接口的操作。
z 在插拔光纤接口前,不能直视这些光纤接口。在拔出光纤接口后,光纤接口的连接
器必须戴上保护帽来保护。
4.5
其它
4.5.1 设备搬运
警告:
在举起沉重设备时,禁止站立或走过起重机的起重臂下面。
4-6
Compliance and Safety Manual
H3C S7500 Series Ethernet Switches
4.5.2 尖锐物体
警告:
在用手搬运设备时,请佩带防护手套以免设备的尖角锐边划伤手。
4.5.3 插拔单板
说明:
插入单板时,不能使用太猛的力,以免损坏背板上的插针。
z 插入单板时,请顺着单板滑道方向进行。避免单板之间的磕碰以免划伤单板或是导
致单板短路。
z在用手抓取单板时,不要触及单板电路、器件、连接器和链接槽。
Chapter 4 安全信息
4.5.4 信号线的捆扎
说明:
信号线应该单独捆扎,不能和高电流和高电压的线缆混在一起。线束之间的间距不能小
于 150mm。
4-7
Compliance and Safety Manual
H3C S7500 Series Ethernet Switches Chapter 5 Sicherheitsinformationen
Chapter 5 Sicherheitsinformationen
5.1 Überblick
Dieser Abschnitt macht Sie mit den Sicherheitsvorschriften vertraut, die Sie bei der
Installation und Instandhaltung de r Ausrüstung von Huawei-3Com beachten müssen.
Anmerkung:
Lesen Sie bitte alle Arbeitsanweisungen und Sicherheitshinweise sorgfältig durch,
bevor Sie mit dem Arbeiten beginnen. Nur durch Beachtung dieser Hinweise lässt sich
das Unfallrisiko minimieren. Die in anderen Handbüchern aufgeführten Symbole
Anmerkung, Achtung, Warnung und Gefahr beinhalten nicht alle zu beachtenden
Sicherheitshinweise. Sie dienen lediglich der Ergänzung. Deshalb muss sich das für
die Installation und Instandhaltung der Ausrüstung von Huawei-3Com verantwortliche
Personal mit allen Sicherheitshinweisen vertraut machen.
Bei der Durchführung der verschiedenen Arbeitsschritte müssen außerdem die
örtlichen Sicherheitsvorschriften beachtet werden. Die in den Handbüchern der
einzelnen Produkte aufgeführten Sicherheitshinweise sind Ergänzungen und
unterliegen den nationalen Sicherheitsvorschriften.
Während der Arbeit mit den Produkten von Huawei-3Com sind deshalb grundsätzlich
alle Sicherheitsvorschriften und spezifischen Sicherheitshinweise genau zu beach ten.
Das für die Installation und Instandhaltung der Produkte von Huawei-3Com
verantwortliche Pesonal muss geschult werden, um alle Sicherheitsvorschriften zu
kennen und die richtigen Arbeitsmethoden anwenden zu können. Nur geschultes und
qualifiziertes Personal kann die Installation und Instandhaltung in korrekter Weise
durchführen.
5.1.1 Symbolerläuterung
Die in diesem Handbuch verwendeten Symbole sind in der folgenden Tabelle
dargestellt. Diese Symbole sollen das Personal während der Installation und
Instandhaltung der Ausrüstung an die Wichtigkeit der im Handbuch aufgeführten
Sicherheitsvorschriften erinnern.
5-1
Compliance and Safety Manual
H3C S7500 Series Ethernet Switches Chapter 5 Sicherheitsinformationen
Table 5-1 Sicherheitssymbole und Beschreibung
Symbol Erläuterung
Alarm: Hinweis auf ein generelles Sicherheitsproblem
ESD-Schutz: Hinweis auf Beschädigung infolge elektrostatischer
Entladung
Elektrischer Schlag: Hinweis auf Gefährdung durch Hochspannung
Mikrowellen: Hinweis auf ein hochintensives elektromagnetisches
Feld
Laser: Hinweis auf einen starken Laserstrahl
Die Sicherheitshinweise sind in die folgenden Gefahrenstufen eingeteilt: Gefahr,
Warnung, Achtung und Anmerkung.
Gefahr: Hinweis auf die Möglichkeit von Unfällen mit tödlichen Verletzungen bei
Nichtbeachtung der Sicherheitsvorschriften.
Warnung: Hinweis auf die Möglichkeit von schweren Unfällen, schweren
Körperverletzungen oder Beschädigungen der Ausrüstung bei Nichtbeachtung der
Sicherheitsvorschriften.
Achtung: Hinweis auf die Möglichkeit von schweren Körperverletzungen oder
Beschädigungen der Ausrüstung bei Nichtbeachtung der Sicherheitsvorschriften .
Anmerkung: Hinweis auf die Möglichkeit einer Körperverletzung oder Beschädigung
der Ausrüstung bei Nichtbeachtung der Sicherheitsvorschriften.
5.1.2 Allgemeine Anforderungen
Um das technisch bedingte Restrisiko auf ein Minimum zu begrenzen, ist es unbedingt
erforderlich, die folgenden Regeln zu beachten:
zLesen Sie alle Anweisungen sorgfältig durch, bevor Sie mit dem Arbeiten
beginnen.
zBeachten Sie, dass bei der Installation des Systems stets zuerst die
Erdverbindung angebracht wird und das die Erdverbindung stets als letztes
getrennt wird.
zSorgen Sie dafür, dass die Öffnungen der Ventilation zu keinem Zeitpunkt
verschlossen, verstopft oder anderweitig blockiert sind. Zwischen den
Ventilationsöffnungen und Wänden bzw. anderen Gegenständen muss stets ein
Abstand von mindestens 5cm bestehen.
zBetreiben Sie die Ausrüstung niemals ohne Erdung. Trennen Sie das System
nicht von der Erdung.
5-2
Compliance and Safety Manual
H3C S7500 Series Ethernet Switches Chapter 5 Sicherheitsinformationen
zDas System muss vor der ständigen Inbetriebnahme geerdet werden. Der
Querschnitt der Erdverbindung sollte mindestens 4mm² betragen.
zMit Gleichstrom betriebenes Modell: Für das Gerät muss eine verstärkte Isolation
bereitgestellt werden, um die 61-72V-Quelle gegen die Hauptversorgung zu
isolieren.
zDa das Gerät mehrere Energiequellen hat, ist es notwendig stets alle
Verbindungen zu unterbrechen, um den energiefreien Zustand zu erreichen.
zZum Anheben und Tragen der Baugruppen erfassen Sie diese bitte an den
Handgriffen, die direkt an der Baugruppe angebracht sind oder umfassen Sie die
untere Kante der Baugruppe. Benutzen Sie nicht die Handgriffe an den einzelnen
Bausteinen, wie z. B. Stromzufuhr, Ventilator oder Karten, da diese das
Gesamtgewicht des Gerätes nicht tragen können.
zVersuchen Sie nicht, Baugruppen allein anzuheben oder zu tragen. Für den
Transport der Baugruppen sind mindestens zwei Perso nen erforderlich. Wenn Sie
Baugruppen anheben, achten Sie bitte darauf, dass Ihr Rücken gerade ist. Sorgen
Sie für einen stabilen und gleichmäßigen Transport der Baugruppen, um
Verletzungen zu vermeiden.
zNehmen Sie das Gerät nicht in Betrieb, solange das optische Fenster nicht
geschlossen ist. Der Laserstrahl kann zu Augenverletzungen führen.
zAus Sicherheitsgründen dürfen bei Arbeiten mit der Ausrüstung keine Uhren,
Armbänder, Ringe oder anderer Schmuck getragen werde n.
zInstallation, Einrichtung und Demontage der Ausrüstung dürfen nur durch
geschultes und qualifiziertes Fachpersonal durchgeführt werden.
zDas System darf nur von qualifizierten und bevollmächtigten Fachkräften
betrieben werden.
zJeder Austausch und jede Änderung am System und seinen T eilen (einschließlich
der Software) darf nur vom qualifizierten und bevollmächtigten Fachpersonal von
Huawei-3Com durchgeführt werden.
zJeder aufgetretene Fehler und jede Funktionsstörung, welche die Sicherheit
gefährden können, müssen unverzüglich vom Betreiber dem verantwortlichen
Personal berichtet werden.
zEntfernen oder Abschalten von Sicherheitseinrichtungen sowie die Instandhaltun g
der Ausrüstung dürfen nur von qualifizierten Fachkräften durchgeführt werden.
zAlle Teile dieses Handbuches sind zu beachten.Das Handbuch dient gleichzeitig
als Ratgeber bei der Auswahl von zusätzlichen Messinstrumenten und
Testvorrichtungen.
5-3
Compliance and Safety Manual
H3C S7500 Series Ethernet Switches Chapter 5 Sicherheitsinformationen
5.2 Elektrische Sicherheit
5.2.1 Hochspannung
Gefahr:
Hochspannungsleitungen stellen die für die Arbeit der Ausrüstung erforderliche
Energie zur Verfügung. Direkter oder indirekter Kontakt (z. B. durch feuchte
Gegenstände) mit Hochspannung und Wechselstromversorgung kann zu tödlichen
Unfällen führen.
zBei der Installation der Wechselstromversorgung sind die örtlichen
Sicherheitsbestimmungen zu beachten. Das Personal muss besond ers qualifiziert
sein für das Arbeiten mit Hochspannung und Wechselstrom.
zEs ist nicht erlaubt während dieser Arbeiten leitende Gegenstände wie Uhren,
Armbänder, Armreifen und Ringe am Körper zu tragen.
zSollte sich Wasser im Baugruppenträger befinden oder der Baugruppenträger
feucht sein, ist die Energiezufuhr sofort zu unterbrechen und das System
abzuschalten.
zMuss in einer feuchten Umgebung gearbeitet werden, ist sicherzustellen, dass
kein Wasser in die Ausrüstung dringen kann.
Warnung:
Die Nichtbeachtung der Sicherheitsvorschriften bei der Arbeit mit Hochspannung kann
zu Feuer und elektrischem Schlag führen. Deshalb m uss die Verle gung von Leit ungen
und Verbindungen den örtlichen Anforderungen und Sicherheitsvorschriften
entsprechen. Arbeiten mit Hochspannung dürfen nur von qualifiziertem Fachpersonal
durchgeführt werden.
5-4
Compliance and Safety Manual
H3C S7500 Series Ethernet Switches Chapter 5 Sicherheitsinformationen
5.2.2 Zuleitung
Anmerkung:
Das Entfernen und Anbringen von Zuleitungen ist strengstens verboten. Kurzschlüsse
zwischen innerem und äußerem Leiter können Lichtbögen oder Funkenflug
verursachen, was zu Feuer oder einer Augenverletzung führen kann.
zDas System muss stets abgeschaltet werden, bevor die Zuleitung angebracht
oder entfernt wird.
zÜberprüfen Sie vor dem Anbringen der Zuleitung immer, ob das von Ihnen
verwendete Kabel den Anforderungen entspricht.
Anmerkung:
Für mit Gleichstrom betriebene Ausrüstung benutzen Sie bitte eine 2.5 mm2 oder 12
AWG Zuleitung.
Für mit Wechselstrom betriebene Ausrüstung benutzen Sie bitte ei ne 1.0 mm
AWG Zuleitung.
Es sind Typ H03VV-F oder eine leichte PVC Schlauchleitung entsprechend IEC 60227
zu benutzen.
5.2.3 Werkzeuge
Warnung:
Für Arbeiten mit Hochspannung und Wechselstrom sind Spezialwerkzeuge zu
verwenden. Es ist nicht erlaubt, herkömmliche Werkzeuge oder Werkzeuge des
Bedienpersonals zu benutzen.
2
oder 16
5-5
Compliance and Safety Manual
H3C S7500 Series Ethernet Switches Chapter 5 Sicherheitsinformationen
5.2.4 Bohren
Warnung:
Das Anbohren des Baugruppenträgers ist verboten. Am Baugrupp enträger darf nur mit
Erlaubnis gebohrt werden. Um die Beschädigung der im Inneren des
Baugruppenträgers verlaufenden Kabel und Leitungen zu vermeiden, sind beim
Bohren die Sicherheitsanforderungen zu beachten. Beim Bohren können Metallspäne
in den Baugruppenträger gelangen und Kurzschlüsse in den Leiterplatten auslösen.
zSollte es wirklich erforderlich sein, in den Baugruppenträger ein Loch zu bohren,
sind zuvor die Kabel aus dem Inneren des Baugruppenträgers zu entfernen.
Während des Bohrens sind isolierende Schutzhand schuhe zu tragen.
zUm die Verletzung der Augen durch umherflieg ende Späne zu vermeiden, hat das
Personal eine Schutzbrille zu tragen.
z Vermeiden Sie, dass die Metallspäne in den Baugruppenträger gelangen.
z Um die EM-Abschirmungseigenschaften des Baugruppenträgers zu erhalten,
müssen beim Bohren alle Sicherheitsanforderungen eingehalten werden.
zEntfernen Sie nach Beendigung des Bohrens bitte unverzüglich alle Metallspäne.
5.2.5 Gewitter
Arbeiten mit Hochspannung und Wechselstrom oder Arbeiten auf Stahltürmen und
masten während eines Gewitters sind verboten.
Das elektromagnetische Feld, das während eines Gewitters entsteht, kann die
Elektronik beschädigen. Um die Ausrüstung vor Beschädigung durch Blitzschlag zu
schützen, ist eine ordnungsgemäße Erdung erforderlich.
Gefahr:
5-6
Compliance and Safety Manual
H3C S7500 Series Ethernet Switches Chapter 5 Sicherheitsinformationen
5.2.6 Elektrostatische Entladung
Achtung:
Die durch den menschlichen Körper erzeugte elektrostatische Energie (statische
Elektrizität) kann die gegen elektrostatische Entladung besonders empfindlichen Teile
der Leiterplatten, wie z. B. die Schaltkreise (LSIC), beschädigen.
zHält man einen herkömmlichen Kunststoffgegenstand in der Hand, wird bei jeder
Bewegung des menschlichen Körpers durch die Reibung d er Kleidung aneinander
oder durch die Reibung der Schuhe mit dem Boden ein ele ktromagnetisches Fel d
erzeugt, welches für lange Zeit im Körper bestehen bleibt.
zDeshalb ist es erforderlich, vor jeder Berührung der Ausrüstung, der Leiterplatten
oder Schaltungen ein geerdetes Armband zur elektrostatischen Entladung zu
tragen. So können die sensiblen Teile vor einer Beschädigung infolge der im
Körper vorhandenen Elektrostatik geschützt werden.
Figure 5-1 Darstellung des geerdeten Armbandes
5.3 Sicherung
Warnung:
Ersetzen Sie die Sicherung bei Bedarf immer nur mit einem Sicherungstyp, der die
gleichen technischen Daten besitzt.
5-7
Compliance and Safety Manual
H3C S7500 Series Ethernet Switches Chapter 5 Sicherheitsinformationen
5.4 Laser
Die von diesem Laser ausgehende Gefahr entspricht der Kateg orie 1.
Warnung:
Während der Installation und Instandhaltung der optischen Fasern dürfen Sie nicht zu
nahe am Ausgang der optischen Fasern stehen und nicht ohne Augenschutz in die
optischen Fasern sehen.
5.4.1 Allgemeine Informationen zum Laser
Laserempfänger und -sender werden in optischen Übertragungssystemen und in
Testinstrumenten einge setzt. Die W ellenl änge der Laserstrahl en liegt in einem B ereich
oberhalb von 780nm bis 1600nm. Der Laser wird durch die optischen Fasern geleitet.
In den Fasern wird das Licht zu einem dünnen Strahl gebündelt. Dieser Lichtstrahl hat
eine sehr hohe Energiedichte und ist für das menschliche Au ge nicht sichtbar . T r iff t der
Lichtstrahl das Auge f ührt das zu schweren B eschädigungen, wie z. B. Verbrennungen
der Netzhaut.
Die in der Telekommunikation verwendeten Wellenlängen verursachen thermische
Schäden, d. h., Beschädigungen infolge Hitzeeinwirkung. Zu einer Beschädigung der
Netzhaut kommt es, wenn eine bestimmte Energiemenge über einen definierten
Zeitraum auf das Gewebe einwirkt.
Laser, die in Lichtwellensystemen verwendet werden, haben eine größere Streuung
des Lichtstrahls, typisch sind Werte zwischen 10° und 20°. Der versehentliche Blick in
eine beschädigte oder nicht abgeschlossene optische Faser ohne Augenschutz aus
einer Entfernung von mehr als 150mm wird grundsätzlich keine Verletzung der Augen
zur Folge haben. Es kann aber zu Verletzungen kommen, wenn optische Instrumente,
wie z. B. Mikroskope, Vergrößerungsgläser oder Lupen, benutzt werden, um das
Faserende zu betrachten.
Das Lichtwellensystem ist vollkommen abgeschlossen und stellt im normalen
Arbeitsmodus keine Gefahr für die Augen dar. Zusätzliche Sicherheit kann jedoch
erzielt werden mit der Durchführung einer automatischen Laserstilllegung (ALS). Die
automatische Laserstilllegung kann nur bei einem System, das in beide Richtungen
überträgt, verwendet werden. Wenn der Empfänger keinen Laserstrahl vom Sender
wahrnimmt, gibt er dem Sender ein Signal, so dass das automatische
Laserstilllegungssystem in weniger als 100ms die Laserausstrahlung been det.
5-8
Compliance and Safety Manual
H3C S7500 Series Ethernet Switches Chapter 5 Sicherheitsinformationen
5.4.2 Richtlinien für den sicheren Umgang mit dem Laser
Lesen Sie sich bitte die folgenden Richtlinien sorgfältig durch, um beim Umgang mit
dem Laser Verletzungen durch Verstrahlung zu vermeiden.
zLesen Sie alle Anweisungen, bevor Sie die Ausrüstung installieren, instandhalten
und in Betrieb nehmen. Die Nichtbeachtung dieser Anweisungen kann zu
gefährlicher Laserverstrahlung führen.
zEs wird empfohlen, während des Umgangs mit den optischen Fasern oder mit
dem Laser eine Schutzbrille zu tragen.
zAlle Arbeiten dürfen nur von bevollmächtigtem Fachpersonal ausgeführt werden,
welches zuvor erfolgreich geschult wurde.
zVergewissern Sie sich, dass die optische Quelle abgeschaltet ist, bevor Sie die
Verbindungen der optischen Fasern abklemmen.
zBevor Sie die vordere Tür eines optischen Übertragungssystems öffnen, müssen
Sie sicherstellen, dass Sie keiner Laserstrahlung ausgesetzt werden können.
zSehen Sie niemals in das Ende einer freigelegten Faser oder in eine offene
Verbindung, wenn Sie nicht sicher sind, dass die optische Quelle auch tatsächli ch
abgeschaltet ist.
zBenutzen Sie ein Optometer, um zu messen, ob die optische Quelle tatsächlich
abgeschaltet ist.
zBenutzen Sie niemals optische Instrumente, wie z. B. Mikroskope,
Vergrößerungsgläser oder Lupen, um die Fasern oder die Verbindungen
anzusehen.
5.4.3 Handhabung der Fasern
Lesen Sie sich die Anweisungen sorgfältig durch, bevor Sie mit den Fasern arbeiten.
zDas Trennen und Verbinden von Fasern darf nur von geschultem Fachpersonal
durchgeführt werden.
zVergewissern Sie sich stets vor dem Trennen und Verbinden von Fasern, dass
diese auch wirklich von der optischen Quelle getrennt wurden. Nach dem
Abklemmen der Fasern von der optischen Quelle müssen alle Verbindungen
durch spezielle Verschlusskappen geschützt werden.
5.5 Sonstiges
5.5.1 Anheben schwerer Gegenstände
5-9
Compliance and Safety Manual
H3C S7500 Series Ethernet Switches Chapter 5 Sicherheitsinformationen
Warnung:
Es ist verboten, unter einem angehobenen Gegenstand zu stehen oder du rchzulaufen.
5.5.2 Scharfkantige Gegenstände
Warnung:
Um sich vor Verletzungen zu schützen dürfen scharfkantige Gegenstände nur mit
Schutzhandschuhen angefasst und transportiert werden.
5.5.3 Einsteckplatinen
Anmerkung:
Beim Einstecken einer Platine darf kein zu großer Druck ausgeübt werden, ansonsten
kann es zur Verdrehung der Kontakte kommen.
zDie Platine muss exakt längs zum Einschub eingeführt werden. Verhindern Sie,
dass sich die Schaltkreise der Platinen berühren. Das kann zu Kurzschluss oder
Kratzern auf der Platine führen.
zBerühren Sie nicht mit den Fingern die Schaltkreise, Einzelkomponenten,
Verbindungen und Verbindungsschlitze.
5.5.4 Zusammenlegen von Signalleitungen
Anmerkung:
Signalleitungen sollten getrennt von Hochspannungsleitungen verlegt werden. Der
Abstand zwischen den Leitungen sollte mindestens 150mm betragen.