H3C LS-S5600-26F, LS-S5600-50C-OVS, S5600-26C, S5600-26C-PWR, S5600-26F Installation Manual

...
H3C S5600 Series Ethernet Switches
Installation Manual
Hangzhou H3C Technologies Co., Ltd. http://www.h3c.com
Manual Version: T2-08045W-20071218-C-1.04
Copyright © 2006-2007, Hangzhou H3C Techn ologies Co ., Ltd. a nd its licensors
All Rights Reserved
No part of this manual may be reproduced or transmitted in any form or by any means without prior written consent of Hangzhou H3C Technologies Co., Ltd.
Trademarks
H3C, , Aolynk, , H3Care,
, TOP G, , IRF, NetPilot, Neocean, NeoVTL, SecPro, SecPoint, SecEngine, SecPath, Comware, Secware, Storware, NQA, VVG, V
2
G, VnG, PSPT, XGbus, N-Bus, TiGem, InnoVision and
HUASAN are trademarks of Hangzhou H3C Technologies Co., Ltd. All other trademarks that may be mentioned in this manual are the property of their
respective owners.
Notice
The information in this document is subject to change without notice. Every effort has been made in the preparation of this document to ensure accuracy of the content s, but all statements, information, and recommendations in this document do not constitute the warranty of any kind, express or implied.
To obtain the latest information, please access: http://www. h3c.com
Technical Support
customer_service@h3c.com http://www. h3c.com
About This Manual
Related Documentation
In addition to this manual, each H3C S5600 Series Ethernet Switches documentation set includes the following:
Manual Description
H3C S5600 Series Ethernet Switches Operation Manual
It is used for assisting the users in data configurations and typical applications.
H3C S5600 Series Ethernet Switches Command Manual
It is used for assisting the users in using various commands.
Organization
H3C S5600 Series Ethernet Switches Installation Manual is organized as follows:
Chapter Contents
1 Product Overview
Introduces the characteristics and technical specifications of S5600 Series Ethernet Switches.
2 Preparing for Installation
Introduces the installation preparation and precaution of S5600 Series Ethernet Switches.
3 Installing the Switch
Introduces the procedures to install an S5600 Series Ethernet Switch, including the setup of the mainframe, cards and cables.
4 Starting up the Switch at the Initial Boot
Introduces the booting process of an S5600 Series Ethernet Switch, including the power-on booting of the switch and the system initialization.
5 Loading Boot ROM and Host Software
Introduces how to load BootROM and host software for an S5600 Series Ethernet Switch.
6 Maintenance and Troubleshooting
Introduces the problems that might occur during the installation and the booting of an S5600 Series Ethernet Switch and the related solution.
7 Appendix A Lightning Protection of the Switch
Introduces lightning protection of S5600 Series Ethernet Switches.
Conventions
The manual uses the following conventions:
I. GUI conventions
Convention Description
< >
Button names are inside angle brackets. For example, click <OK>.
[ ]
Window names, menu items, data table and field names are inside square brackets. For example, pop up the [New User] window.
/
Multi-level menus are separated by forward slashes. For example, [File/Create/Folder].
II. Symbols
Convention Description
Warning
Means reader be extremely careful. Improper operation may cause bodily injury.
Caution
Means reader be careful. Improper operation may cause data loss or damage to equipment.
Note Means a complementary description.
Environmental Protection
This product has been designed to comply with the requirements on environmental protection. For the proper storage, use and disposal of this product, national laws and regulations must be observed.
Installation Manual H3C S5600 Series Ethernet Switches Table of Contents
i
Table of Contents
Chapter 1 Product Overview........................................................................................................1-1
1.1 Overview............................................................................................................................1-1
1.2 S5600-26C/S5600-26C-PWR/S5600-26F Ethernet Switch ..............................................1-2
1.2.1 Front Panel.............................................................................................................. 1-2
1.2.2 Rear Panel ............................................................................................................ 1-10
1.3 S5600-50C/S5600-50C-PWR Ethernet Switch ............................................................... 1-11
1.3.1 Front Panel............................................................................................................ 1-11
1.3.2 Rear panel.............................................................................................................1-12
1.4 Power system .................................................................................................................. 1-13
1.5 Cooling system ................................................................................................................ 1-13
1.6 Attributes of 1000 Mbps SFP port....................................................................................1-14
1.7 Expansion Module...........................................................................................................1-15
1.8 S5600 Series Technical Specifications ...........................................................................1-18
Chapter 2 Preparing for Installation............................................................................................2-1
2.1 Safety Precautions............................................................................................................. 2-1
2.2 Installation Site...................................................................................................................2-1
2.2.1 Temperature/Humidity.............................................................................................2-1
2.2.2 Cleanness ............................................................................................................... 2-2
2.2.3 Electromagnetic Susceptibility ................................................................................ 2-2
2.2.4 Laser Safety............................................................................................................2-3
2.3 Installation Tools................................................................................................................ 2-3
Chapter 3 Installing the Switch.................................................................................................... 3-1
3.1 Rack-Mounting the Switch................................................................................................. 3-1
3.1.1 Introduction to mounting ear ................................................................................... 3-1
3.1.2 Introduction to guide rail..........................................................................................3-2
3.1.3 Use front mounting ears and a tray......................................................................... 3-3
3.1.4 Use front and rear mounting ears ........................................................................... 3-4
3.1.5 Use front mounting ears and guide rails................................................................. 3-7
3.2 Mounting the Switch on a Tabletop/Workbench................................................................ 3-9
3.3 Installing/Removing the Power Module...........................................................................3-10
3.3.1 Installing the Power Module.................................................................................. 3-10
3.3.2 Removing the Power Module................................................................................ 3-10
3.4 Connecting the Power Cord and the Ground Wire.......................................................... 3-11
3.4.1 Connecting the AC-Input Power Cord................................................................... 3-11
3.4.2 Connecting the DC-Input Power Cord ..................................................................3-12
3.4.3 Connecting the Ground Wire.................................................................................3-13
3.5 Connecting the Switch to a Console Terminal................................................................. 3-16
Installation Manual H3C S5600 Series Ethernet Switches Table of Contents
ii
3.5.1 Console Cable....................................................................................................... 3-16
3.5.2 Connecting the Console Cable ............................................................................. 3-16
3.6 Installing/Removing the Stack Cable............................................................................... 3-17
3.6.1 Stack Cable........................................................................................................... 3-17
3.6.2 Installing the Stack Cable......................................................................................3-17
3.6.3 Removing the Stack Cable....................................................................................3-18
3.7 Installing/Removing the Optional Interface Module......................................................... 3-18
3.8 Verifying Installation......................................................................................................... 3-19
Chapter 4 Starting up the Switch at the Initial Boot .................................................................. 4-1
4.1 Setting up a Configuration Environment............................................................................4-1
4.2 Connecting the Console Cable.......................................................................................... 4-1
4.3 Setting Terminal Parameters............................................................................................. 4-1
4.4 Booting the Switch.............................................................................................................4-4
4.4.1 Verifying Installation before Power-up .................................................................... 4-4
4.4.2 Powering up the Switch........................................................................................... 4-4
Chapter 5 Loading Boot ROM and Host Software ..................................................................... 5-1
5.1 Introduction to Loading Approaches..................................................................................5-1
5.2 Loading Software Locally...................................................................................................5-1
5.2.1 Boot Menu............................................................................................................... 5-1
5.2.2 Loading Software from Console Port Using XModem............................................5-3
5.2.3 Loading Software from an Ethernet Port Using TFTP ............................................ 5-7
5.2.4 Loading Software from an Ethernet Port Using FTP...............................................5-9
5.3 Loading Software Remotely.............................................................................................5-10
5.3.1 Loading Software Remotely Using FTP................................................................5-10
5.3.2 Loading Software Remotely Using TFTP..............................................................5-11
Chapter 6 Maintenance and Troubleshooting............................................................................ 6-1
6.1 Dealing with Loading Failures............................................................................................6-1
6.2 Dealing with Password Loss..............................................................................................6-1
6.3 Dealing with Power System Failures.................................................................................6-1
6.4 Dealing with Configuration System Failures......................................................................6-1
Installation Manual H3C S5600 Series Ethernet Switches Chapter 1 Product Overview
1-1
Chapter 1 Product Overview
1.1 Overview
H3C S5600 Series Ethernet Switches are high-performance, high-density, easy-to-install, NMS-manageable intelligent Ethernet switches which support wire-speed Layer2/3 switching.
Table 1-1 lists the models of H3C S5600 Series Ethernet Switches.
Table 1-1 Models of H3C S5600 Series Ethernet Switches
Model
Number of
10/100/1000M
electrical ports
Number of
1000M SFP
optical ports
Number of
Console ports
S5600-26C S5600-26C-PWR
24 4
S5600-26F 4 24 S5600-50C S5600-50C-PWR
48 4
1
Each SFP port and the corresponding 10/100/1000M Ethernet port form a Combo port. For each Combo port, the SFP port and the 10/100/1000M Ethernet port cannot be used at the same time. For the relationship between the Combo ports and the Ethernet ports, refer to
Table 1-2.
Table 1-2 Combo port list
Switch model Combo Port Corresponding port
25 22 26 24 27 21
S5600-26C/S5600-26C
-PWR/S5600-26F 28 23
49 46 50 48 51 45
S5600-50C/S5600-50C
-PWR 52 47
Installation Manual H3C S5600 Series Ethernet Switches Chapter 1 Product Overview
1-2
Note:
z The electrical ports of S5600-26C-PWR/S5600-50C-PWR are capable of sup plying
-48 VDC power to remote PDs (powered devices, such as S2016C, S2008B, S2016B, S2016-EI, and so on).
z The S5600-26C-PWR/S5600-50C-PWR adopts PoE power module, which provides
AC/DC power to PD devices. When delivering the AC input, the module can supply up to 300 W power. If more power is needed, use the DC input or both AC and DC inputs to ensure the operation of all the connected devices.
z The S5600-26C-PWR/S5600-50C-PWR can also adopt AC/DC dual input power
module. In this case, however, the two types of switches have no PoE function. And they function exactly like the S5600-26C and S5600-50C.
1.2 S5600-26C/S5600-26C-PWR/S5600-26F Ethernet Switch
1.2.1 Front Panel
I. Front panel
The S5600-26C/S5600-26C-PWR provides 24 x 10/100/1000Base-TX Ethernet ports, one Console port, and four 1000 Mbps SFP Combo ports on its front panel. Each SFP port and the corresponding 10/100/1000M Ethernet port form a Combo port. For each Combo port, the SFP port and the 10/100/1000M Ethernet port cannot be used at the same time. For the relationship between the Combo ports and the Ethernet port s, refer to
Table 1-2.
Figure 1-1 shows the front panel of an S5600-26C Ethernet switch.:
(1) 10/100/1000M auto-negotiation Ethernet port status LEDs (2) 1000 Mbps SFP Combo port LED (3) Console port (4) 7-segment digitron display (5) Power LED (6) DC LED (7) Fabric LED (8) Module LED (9) Port mode LED (10) Mode button
Figure 1-1 Front panel of the S5600-26C/S5600-26C-PWR
Installation Manual H3C S5600 Series Ethernet Switches Chapter 1 Product Overview
1-3
The S5600-26F provides 24 x 1000 Mbps SFP optical port s, one Console port, and four 1000 Mbps RJ-45 Combo ports on it s front panel. Each SFP port an d the corresponding 10/100/1000M Ethernet port form a Combo port. For each Combo port, the SFP port and the 10/100/1000M Ethernet port cannot be used at the same time. For the relationship between the Combo ports and the Ethernet ports, refer to
Table 1-2.
Figure 1-2. shows the front panel of an S5600-26F Ethernet switch.:
(1) SFP optical port status LED (2) 10/100/1000M auto-negotiation Ethernet port status LEDs: left one for speed, right one for duplex mode (3) Console port (4) 7-segment digitron display (5) Power LED (6) RPS LED (7) Fabric LED (8) Module LED
Figure 1-2 Front panel of the S5600-26F
II. LEDs
The S5600-26C/S5600-26C-PWR provides one power LED, one RPS LED, one fabri c LED, one module LED, one mode LED, one 7-segment digitron display, four pairs of 1000 Mbps SFP port status LEDs, and 24 pairs of 10/100/1000M port status LEDs on its front panel.
The S5600-26F provides one power LED, one RPS LED, one fabric LED, one module LED, one 7-segment digitron display , 24 pairs of 1000 Mbps SFP port status LEDs, and four pairs of 10/100/1000M auto-negotiation Ethernet port status LEDs on its front panel.
Table 1-3 and Table 1-4 describe respectively the LEDs on the S5600-26C/S5600-26C-PWR and S5600-26F.
Installation Manual H3C S5600 Series Ethernet Switches Chapter 1 Product Overview
1-4
Table 1-3 LEDs on the S5600-26C/S5600-26C-PWR
LED Mark Status Description
Speed Solid green
The port status LEDs are showing the speed of each port.
Duplex Solid yellow
The port LEDs are showing the duplex mode of each port.
Mode LED Mode
PoE
Blinking green (at 1 Hz)
The port LEDs are showing the PoE status of each port.
Solid green The switch is started normally.
Blinking green (at 1 Hz)
The system is running power-on self-test (POST).
Solid red
The system fails the POST, or there is another fault.
Blinking yellow (at 1 Hz)
Some ports fail the POST and do not function.
Power LED
PWR
OFF The switch is power-off.
Solid green
Both the AC power supply and the DC input operate normally.
Solid yellow
The AC power supply fails or the AC input is disconnected, while the DC input operates normally.
DC LED RPS
OFF DC input is disconnected.
Green
The device is in the ring fabric status; the LED blinks quickly when the fabric port is receiving or sending data.
Yellow
The device is in the daisy chain fabric status; the LED blinks quickly when the fabric port is receiving or sending data.
Blinking green (at 3 Hz)
This device is isolated from the whole set of fabric devices (effective when this device is in the fabric status).
Fabric LED
STK
OFF
Neither of the two fabric ports is connected.
Installation Manual H3C S5600 Series Ethernet Switches Chapter 1 Product Overview
1-5
LED Mark Status Description
Solid green
The module is seated and operates normally.
Blinking yellow
The module fails or is not supported.
Module LED
Module (MOD)
OFF No module is installed.
POST running
Blinking green
The POST ID of the in-process test is displayed:
POST failed
Blinking red
The POST ID of the failed test blinks.
Software downloading
Blinking green
A light bar rotates clockwise around the display during the downloading procedure.
Fan failed Solid red
An “F” is displayed.
Over temperature alarm
Solid red
A “t” is displayed.
Speed and duplex mode
Solid green
UNIT ID in the fabric; or “1” for a standalone unit is displayed.
7-segment digitron display
Unit
PoE mode
Solid green
The utilization of the power supply is displayed.
0 - 20%
21 - 40%
41 - 60%
61 - 80%
81 - 100%
Installation Manual H3C S5600 Series Ethernet Switches Chapter 1 Product Overview
1-6
LED Mark Status Description
Green
The port is operating at 1000 Mbps. The LED blinks quickly when the port is receiving or sending data.
Yellow
The port is operating at 10/100 Mbps. The LED blinks quickly when the port is receiving or sending data.
Blinking yellow (at 3 Hz)
The port fails the POST.
Speed mode
OFF The port is not connected.
Green
The port is operating in full duplex mode. The LED blinks quickly when the port is receiving or sending data.
Yellow
The port is operating in half duplex mode. The LED blinks quickly when the port is receiving or sending data.
Blinking Yellow (3 Hz)
The port fails the POST.
Duplex mode
OFF The port is not connected. Solid
green
The port supplies power normally.
Blinking green (at 1 Hz)
The connected device requires more power than the maximum power a port can supply.
The port cannot supply power because the switch has reached its maximum power supplied.
Solid yellow
The port cannot supply power because the connected device is not a PD.
The port cannot supply power due to the power source failure of PoE.
Blinking yellow (3 Hz)
The port fails the POST.
10/100/ 1000M auto­negotiation Ethernet port status LED
PoE mode
OFF The port does not supply power.
Installation Manual H3C S5600 Series Ethernet Switches Chapter 1 Product Overview
1-7
LED Mark Status Description
Green
The port is operating at 1000 Mbps. The LED blinks quickly when the port is receiving or sending data.
Blinking yellow (3 Hz)
The port fails the POST.
Speed mode
OFF The port is not connected.
Green
The port is operating in 1000 Mbps full duplex mode. The LED blinks quickly when the port is receiving or sending data.
Blinking yellow (3 Hz)
The port fails the POST.
Duplex mode
OFF The port is not connected.
1000M Base SFP port mode LED
PoE mode OFF
Table 1-4 LEDs on the S5600-26F
LED Mark Status Description
Solid green The switch is started normally.
Blinking green (at 1 Hz)
The system is running power-on self-test (POST).
Solid red
The system fails the POST, or there is another fault.
Blinking yellow (at 1 Hz)
Some ports fail the POST and do not function.
Power LED
PWR
OFF The switch is power-off.
Solid green
Both the AC power supply and the DC input operate normally.
Solid yellow
The AC power supply fails or the AC input is disconnected, while the DC input operates normally.
DC LED RPS
OFF DC input is disconnected.
Installation Manual H3C S5600 Series Ethernet Switches Chapter 1 Product Overview
1-8
LED Mark Status Description
Green
The device is in the ring fabric status; the LED blinks quickly when the fabric port is receiving or sending data.
Yellow
The device is in the daisy chain fabric status; the LED blinks quickly when the fabric port is receiving or sending data.
Blinking green (at 3 Hz)
This device is isolated from the whole set of fabric devices (effective when this device is in the fabric status).
Fabric LED
STK
OFF
Neither of the two fabric ports is connected.
Solid green
The module is seated and operates normally.
Blinking yellow
The module fails or is not supported.
Module LED
Module (MOD)
OFF No module is installed.
POST running
Blinking green
The POST ID of the in-process test is displayed:
POST failed
Blinking red
The POST ID of the failed test blinks.
Software downloading
Blinking green
A light bar rotates clockwise around the display during the downloading procedure.
Fan failed Solid red
An “F” is displayed.
Over temperature alarm
Solid red
A “t” is displayed.
7-segment digitron display
Unit
Speed and duplex mode
Solid green
UNIT ID in the fabric; or “1” for a standalone unit is displayed.
Installation Manual H3C S5600 Series Ethernet Switches Chapter 1 Product Overview
1-9
LED Mark Status Description
Green
The port is operating at 1000 Mbps. The LED blinks quickly when the port is receiving or sending data.
Yellow
The port is operating at 10/100 Mbps. The LED blinks quickly when the port is receiving or sending data.
Blinking yellow (at 3 Hz)
The port fails the POST.
Speed mode
OFF The port is not connected.
Green
The port is operating in full duplex mode. The LED blinks quickly when the port is receiving or sending data.
Yellow
The port is operating in half duplex mode. The LED blinks quickly when the port is receiving or sending data.
Blinking Yellow (3 Hz)
The port fails the POST.
10/100/ 1000M auto­negotiation Ethernet port status LED
Duplex mode
OFF The port is not connected.
Green
The port is operating at 1000 Mbps. The LED blinks quickly when the port is receiving or sending data.
Blinking yellow (3 Hz)
The port fails the POST.
1000Base SFP optical port status LED
port status LED
OFF The port is not connected.
III. Console port
The S5600-26C/S5600-26C-PWR/S5600-26F provides an EIA/TIA-232-compliant Console port, which enables you to configure the switch from the local or remote site.
Table 1-5 Attributes of the Console port
Item Description
Connector RJ-45 Standard EIA/TIA-232
Installation Manual H3C S5600 Series Ethernet Switches Chapter 1 Product Overview
1-10
Item Description
Baud rate 9600 bps (default), auto-negotiation is supported
Services
Connection to an ASCII terminal Connection to the serial port of a local terminal (a PC for
example) or a remote terminal (through a pair of modems) running terminal emulation software
1.2.2 Rear Panel
I. Rear panel
Note:
The ports of the AC/DC dual input power module and the PoE power module are exactly the same, so only one rear panel illustration is shown below.
The S5600-26C/S5600-26C-PWR/S5600-26F provides two sockets for pluggable power module, two fabric ports, one expansion slot, and one grounding screw on its rear panel, as shown in the following figure.
(1) AC-input power socket for the power module (2) Expansion module (3) Grounding screw (4) Fabric ports (5) Fabric port LEDs (6) RPS LED (7) DC-input power socket for the power module
Figure 1-3 Rear panel of the S5600-26C/S5600-26C-PWR/S5600-26F
II. Fabric port
The fabric port marked with “UP” connects to a port of the same type on an upstream device; the fabric port marked with “DOWN” connects to a port of the same type on a downstream device.
Installation Manual H3C S5600 Series Ethernet Switches Chapter 1 Product Overview
1-11
Table 1-6 Fabric port LEDs
LED Mark Status Indicate
Solid green The fabric port is properly connected. Blinking
green
The fabric port is properly connected and the port is receiving or sending data.
Fabric port LED
UP(DOWN)
OFF The fabric port is disconnected.
1.3 S5600-50C/S5600-50C-PWR Ethernet Switch
1.3.1 Front Panel
I. Front panel
The S5600-50C/S5600-50C-PWR provides 48 x 10/100/1000Base-TX Ethernet ports, one Console port, and four 1000 Mbps SFP Combo ports on its front panel. Each SFP port and the corresponding 10/100/1000M Ethernet port form a Combo port. For each Combo port, the SFP port and the 10/100/1000M Ethernet port cannot be used at the same time. For the relationship between the Combo ports and the Ethernet port s, refer to
Table 1-2.
Figure 1-4 shows the front panel of an S5600-50C/S5600-50C-PWR Ethernet switch:
(1) 10/100/1000M auto-negotiation Ethernet port status LEDs (2) Console Port (3) 7-segment digitron display (4) Mode button (5) Mode LED (6) Power LED (7) RPS LED (8) Fabric LED (9) Module LED (10) 1000 Mbps SFP combo port LED
Figure 1-4 Front panel of the S5600-50C/S5600-50C-PWR
Installation Manual H3C S5600 Series Ethernet Switches Chapter 1 Product Overview
1-12
II. LEDs
The S5600-50C/S5600-50C-PWR provides one power LED, RPS LED, fabric LED, module LED, mode LED, 7-segment digitron display, 1000 Mbps SFP port statu s LED, and auto-negotiation Ethernet port status LED on its front panel. The meaning of each LED is shown in
Table 1-3
III. Console port
The S5600-50C/S5600-50C-PWR provides an EIA/TIA-232-compliant console port, which enables you to configure the switch from the local or remote site. For the attributes of the port, refer to
Table 1-5.
1.3.2 Rear panel
I. Rear panel
Note:
The ports of the AC/DC dual input power module and the PoE power module are exactly the same, so only one rear panel illustration is shown below.
The S5600-50C/S5600-50C-PWR provides two sockets for pluggable power module, two fabric ports, one expansion slot, and one grounding screw on its rear panel, as shown in the following figure.
(1) AC-input power socket for the power module (2) Expansion module (3) Grounding screw (4) Fabric ports (5) Fabric port LEDs (6) RPS LED (7) DC-input power socket for the power module
Figure 1-5 Rear panel of the S5600-50C/S5600-50C-PWR
II. Fabric ports
For fabric ports and the meanings of their LEDs, refer to Table 1-6.
Installation Manual H3C S5600 Series Ethernet Switches Chapter 1 Product Overview
1-13
1.4 Power system
z AC power input range
Rated voltage: 100 to 240 VAC; 50/60 Hz Max. voltage range: 90 to 264 VAC; 50/60 Hz
z DC power input range
Rated voltage: –48 to–60 V Max. voltage range: –36 to–72 V
z AC input of the PoE power module
Rated voltage: 100 to 240 VAC; 50/60 Hz Max. voltage range: 90 to 264 VAC; 50/60 Hz
z DC input of the PoE power module
Rated voltage: –53.5 V Max. voltage range: –52 to –55 V
Note:
The S5600-26C-PWR/S5600-50C-PWR must use the external PoE PSU recommended by H3C as its DC input, but not the -48VDC power supply generally available in the equipment room. Otherwise, the device may be damaged.
1.5 Cooling system
S3100-8TP-PWR-EI Ethernet switches each run two fans for heat dissipation. Table 1-7 S5600 Ethernet switches cooling system
(1)
Model S5600-26C S5600-26C-PWR S5600-26F
Cooling system
Two fans are for the device and two are for the power supply module.
Two fans are for the device and four are for the power supply module.
Four fans are for the device and two are for the power supply module.
Installation Manual H3C S5600 Series Ethernet Switches Chapter 1 Product Overview
1-14
Table 1-8 S5600 Ethernet switches cooling system (2)
Model S5600-50C S5600-26C-PWR
Cooling system
Two fans are for the device and two are for the power supply module.
Two fans are for the device and four are for the power supply module.
1.6 Attributes of 1000 Mbps SFP port
The S5600-26C/S5600-26C-PWR/S5600-50C/S5600-50C-PWR provides 4 × 1000 Mbps SFP ports on it s front panel. The S5600 -26F provides 24 × 1000 Mbp s SFP ports on its front panel.
SFP modules allow for great flexibility in networking because they are hot swappable and user configurable.
Table 1-9 lists the available SFP modules that you can select as re quired:
Table 1-9 Optical port module
Type Model
SFP-GE-SX-MM850-A SFP-GE-LX-SM1310-A SFP-GE-LH40-SM1310 SFP-GE-LH40-SM1550
1000M SFP module
SFP-GE-LH70-SM1550
SFP module
SFP electrical interface module SFP-GE-T
Note:
z Only the optical module that H3C Technology provides or recommends can be
used.
z The types of SFP modules may vary with time. Consult H3C marketing personnel or
technical support personnel to obtain the latest information about SFP modules.
z For specifications of SFP modules, refer to H3C Low End Series Ethernet Switches
Pluggable Module Manual.
Installation Manual H3C S5600 Series Ethernet Switches Chapter 1 Product Overview
1-15
1.7 Expansion Module
The S5600 Series Ethernet switches provide one expansion module slot on the rear panel. The expansion mode that can be used in this slot includes 8-port 1000 Mbps SFP module, 1-port 10 Gbps XENPAK module, and 2-port 10 Gbps XFP module.
I. 8-port 1000 Mbps SFP module
(1) Port status LEDs (2) SFP ports (3) Module power LED
Figure 1-6 8-port 1000 Mbps SFP module
This module provides eight 1000 Mbps SFP external optical/electrical ports.
z For an optical port, you can choose one of the following SFP modules according to
your needs.
Table 1-10 Optical port module supported by 8-port 1000 Mbps SFP module
SFP module
Central wavelength
Fiber specifications
Maximum transmission distance
SFP-GE-SX-MM850-A SFP-GE-LX-SM1310-A
SFP module 1000M SFP module
SFP-GE-LH40-SM1310
Note:
z The types of SFP modules may vary with time. Consult H3C marketing personnel or
technical support personnel to obtain the latest information about SFP modules.
z For specifications of SFP modules, refer to H3C Low End Series Ethernet Switches
Pluggable Module Manual.
z For an RJ-45 electrical port with the transmission distance is 100 m (328 ft), you
can select the RJ-45 connector as shown in the following figure, and the category-5 twisted pair as the data transmission medium.
Installation Manual H3C S5600 Series Ethernet Switches Chapter 1 Product Overview
1-16
Figure 1-7 RJ-45 connector
Table 1-11 Pinouts of the RJ-45 GE port
1000Base-TX
Pin
Signal Function
1 MX_0+ Data transmit/receive 2 MX_0- Data transmit/receive 3 MX_1+ Data transmit/receive 4 MX_2+ Data transmit/receive 5 MX_2- Data transmit/receive 6 MX_1- Data transmit/receive 7 MX_3+ Data transmit/receive 8 MX_3- Data transmit/receive
II. 2-port 10 Gbps XFP module
(1) Module power LED (2) Port status LEDs (3) 10 Gbps XFP optical ports
Figure 1-8 2-port 10 Gbps XFP module
This module provide two 10 Gbps XFP optical port. The following table lists the available XFP optical modules that you can select according to your needs:
Loading...
+ 50 hidden pages