H3C S5500-28C-PW, S5500-28C-SI 24, S5500-52C-SI 48, S5500-52C-PW, S5500-20TP-SI Installation Manual

...
H3C S5500-SI Complete Series
Ethernet Switches
Installation Manual
Hangzhou H3C Technologies Co., Ltd. http://www.h3c.com
Copyright © 2007, Hangzhou H3C Technologies Co., Ltd. and its licensors
All Rights Reserved
No part of this manual may be reproduced or transmitted in any form or by any means without prior written consent of Hangzhou H3C Technologies Co., Ltd.
Trademarks
H3C, , Aolynk, , H3Care,
, TOP G, , IRF, NetPilot, Neocean, NeoVTL, SecPro, SecPoint, SecEngine, SecPath, Comware, Secware, Storware, NQA, VVG, V
2
G, VnG, PSPT, XGbus, N-Bus, TiGem, InnoVision and
HUASAN are trademarks of Hangzhou H3C Technologies Co., Ltd. All other trademarks that may be mentioned in this manual are the property of their
respective owners.
Notice
The information in this document is subject to change without notice. Every effort has been made in the preparation of this document to ensure accuracy of the content s, but all statements, information, and recommendations in this document do not constitute the warranty of any kind, express or implied.
To obtain the latest information, please access: http://www. h3c.com
Technical Support
customer_service@h3c.com http://www. h3c.com
About This Manual
Related Documentation
In addition to this manual, each H3C S5500-SI Complete Series Ethernet Switches documentation set includes the following:
Manual Description
H3C S5500-SI Series Ethernet Switches Operation Manual
It is used for assisting the users in data configurations and typical applications.
H3C S5500-SI Series Ethernet Switches Command Manual
It is used for assisting the users in using various commands.
Organization
H3C S5500-SI Complete Series Ethernet Switches Installation Manual is organized as follows:
Chapter Contents
1 Product Overview
Introduces the characteristics and technical specifications of S5500-SI Complete Series Ethernet Switches.
2 Preparing for Installation
Introduces the installation preparation and precaution of S5500-SI Complete Series Ethernet Switches.
3 Installing the Switch
Introduces the procedures to install an S5500-SI Complete Series Ethernet Switch, including the setup of the mainframe, cards and cables.
4 Powering on the Switch for the First Time
Introduces the booting process of an S5500-SI Complete Series Ethernet Switch, including the power-on booting of the switch and the system initialization.
5 BootROM and Host Software Loading
Introduces how to load BootROM and host software for an S5500-SI Complete Series Ethernet Switch.
6 Maintenance and Troubleshooting
Introduces the problems that might occur during the installation and the booting of an S5500-SI Complete Series Ethernet Switch and the related solution.
Appendix A Lightning Protection of the Switch
Introduces lightning protection of S5500-SI Complete Series Ethernet Switches.
Conventions
The manual uses the following conventions:
I. GUI conventions
Convention Description
< >
Button names are inside angle brackets. For example, click <OK>.
[ ]
Window names, menu items, data table and field names are inside square brackets. For example, pop up the [New User] window.
/
Multi-level menus are separated by forward slashes. For example, [File/Create/Folder].
II. Symbols
Convention Description
Warning
Means reader be extremely careful. Improper operation may cause bodily injury.
Caution
Means reader be careful. Improper operation may cause data loss or damage to equipment.
Note Means a complementary description.
Environmental Protection
This product has been designed to comply with the requirements on environmental protection. For the proper storage, use and disposal of this product, national laws and regulations must be observed.
Installation Manual H3C S5500-SI Complete Series Ethernet Switches Table of Contents
i
Table of Contents
Chapter 1 Product Overview........................................................................................................1-1
1.1 Preface...............................................................................................................................1-1
1.2 Introduction to S5500-SI Series Ethernet Switches...........................................................1-3
1.2.1 S5500-28C-SI Ethernet Switch...............................................................................1-3
1.2.2 S5500-52C-SI Ethernet Switch...............................................................................1-4
1.2.3 S5500-28C-PWR-SI Ethernet Switch......................................................................1-5
1.2.4 S5500-52C-PWR-SI Ethernet Switches.................................................................. 1-7
1.2.5 S5500-20TP-SI Ethernet Switch.............................................................................1-8
1.3 Introduction to Front Panel LEDs.....................................................................................1-10
1.3.1 LEDs of S5500-28C-SI/S5500-52C-SI Switch......................................................1-10
1.3.2 LEDs of S5500-28C-PWR-SI/S5500-52C-PWR-SI Switch................................... 1-12
1.3.3 LEDs of S5500-20TP-SI Switch............................................................................1-16
1.4 System Specifications of the S5500-SI Series................................................................1-19
1.5 SFP Modules ................................................................................................................... 1-21
1.6 Optional Interface Modules..............................................................................................1-21
1.6.1 One-port 10 GE XFP Interface Module.................................................................1-22
1.6.2 Dual-Port 10 GE XFP Interface Module................................................................1-22
1.6.3 Short-haul Dual-Port 10 GE CX4 Interface Module..............................................1-23
1.6.4 Description of LEDs of Extension Modules...........................................................1-23
1.7 CX4 Cable........................................................................................................................1-23
Chapter 2 Preparing for Installation............................................................................................2-1
2.1 Safety Precautions............................................................................................................. 2-1
2.2 Installation Site...................................................................................................................2-1
2.2.1 Temperature/Humidity.............................................................................................2-1
2.2.2 Cleanness ............................................................................................................... 2-2
2.2.3 Electromagnetic Susceptibility ................................................................................ 2-2
2.2.4 Laser Safety............................................................................................................2-3
2.3 Installation Tools................................................................................................................ 2-3
Chapter 3 Installing the Switch.................................................................................................... 3-1
3.1 Rack-Mounting the Switch................................................................................................. 3-1
3.1.1 Cabinet Mounting.................................................................................................... 3-1
3.1.2 Mounting the Switch on a Workbench .................................................................. 3-10
3.2 Connecting the Power Cords and the Ground Wire........................................................3-11
3.2.1 Connecting the AC Power Cord............................................................................ 3-11
3.2.2 Connecting the DC Power Cord............................................................................ 3-12
3.2.3 Connecting the Ground Wire.................................................................................3-15
3.3 Connecting Optical Fiber.................................................................................................3-17
Installation Manual H3C S5500-SI Complete Series Ethernet Switches Table of Contents
ii
3.4 Connecting Console Cable.............................................................................................. 3-17
3.4.1 Console Cable....................................................................................................... 3-17
3.4.2 Connecting Console Cable ................................................................................... 3-18
3.5 Installing and Removing Optional Interface Modules......................................................3-19
3.5.1 10 GE XFP Interface Module................................................................................3-19
3.5.2 Short-haul Dual-port 10 GE CX4 Interface Module...............................................3-22
3.6 Installing Dedicated CX4 Cable....................................................................................... 3-23
3.6.1 Installing Dedicated CX4 Cable ............................................................................ 3-23
3.6.2 Removing Dedicated CX4 Cable .......................................................................... 3-23
3.7 Verifying the Installation................................................................................................... 3-23
Chapter 4 Powering on the Switch for the First Time................................................................4-1
4.1 Setting up the Configuration Environment.........................................................................4-1
4.2 Connecting Console Cable................................................................................................ 4-1
4.3 Setting Terminal Parameters............................................................................................. 4-1
4.4 Booting the Switch.............................................................................................................4-5
4.4.1 Checking before Powering on the Switch ............................................................... 4-5
4.4.2 Powering on the Switch........................................................................................... 4-5
4.4.3 Changing the Startup Mode....................................................................................4-7
Chapter 5 Boot ROM and Host Software Loading ..................................................................... 5-1
5.1 Introduction to Loading Modes .......................................................................................... 5-1
5.2 Local Software Loading.....................................................................................................5-1
5.2.1 Boot Menu............................................................................................................... 5-2
5.2.2 Loading Software Using XMODEM Through Console Port....................................5-3
5.2.3 Loading Software Using TFTP through Ethernet Port............................................5-8
5.2.4 Loading Software Using FTP Through Ethernet Port............................................. 5-9
5.3 Remote Software Loading...............................................................................................5-11
5.3.1 Remote Loading Using FTP..................................................................................5-11
5.3.2 Remote Loading Using TFTP................................................................................5-13
Chapter 6 Maintenance and Troubleshooting............................................................................ 6-1
6.1 Software Loading Failure................................................................................................... 6-1
6.2 Password Missing Failure..................................................................................................6-1
6.2.1 Missing User Password........................................................................................... 6-1
6.2.2 Missing Boot ROM Password ................................................................................. 6-2
6.3 Power Supply Failure......................................................................................................... 6-2
6.4 Configuration System Failure ............................................................................................ 6-2
Installation Manual H3C S5500-SI Complete Series Ethernet Switches Chapter 1 Product Overview
1-1
Chapter 1 Product Overview
1.1 Preface
H3C S5500-SI Series Ethernet switches (hereinafter referred to as S5500-SI series) are Gigabit Ethernet switching products developed by H3C.
Currently, S5500-SI Series Ethernet switches include the S5500-28C-SI, S5500-52C-SI, S5500-28C-PWR-SI, S5500-52C-PWR-SI, and S5500-20TP-SI, as listed in the following table:
Table 1-1 H3C S5500-SI Series Ethernet switches
Name Model
Power
supply
Number of
10/100/1000
Mbps
electrical ports
Number
of gigabit
uplink
ports
Number
of
Console
ports
S5500-28C-SI 24 S5500-52C-SI 48 S5500-28C-PW
R-SI
24
S5500-52C-PW R-SI
AC input or RPS DC input
48
Four Gigabit SFP Combo ports
H3C S5500-SI Series Ethernet switches
S5500-20TP-SI AC input 8
Twelve Gigabit SFP ports
1
Each SFP port and the corresponding 10/100/1000BASE-T Ethernet port form a Combo port. For each Combo port, either the SFP port or the corresponding 10/100/1000BASE-T Ethernet port can be used at a time. Refer to
Table 1-2.
Table 1-2 Combo port mapping relationship
Model Combo port Corresponding port
25 22 26 24 27 21
S5500-28C-SI S5500-28C-PWR-SI
28 23
Installation Manual H3C S5500-SI Complete Series Ethernet Switches Chapter 1 Product Overview
1-2
Model Combo port Corresponding port
49 46 50 48 51 45
S5500-52C-SI S5500-52C-PWR-SI
52 47
Note:
A Gigabit Combo port and its corresponding 10/100/1000BASE-T autosensing Ethernet port cannot be used together at the same time. For details, refer to the Port
Correlation Configuration part of the H3C S5500-SI Series Ethernet Switches Operation Manual.
S5500-SI series have abundant service features. They provide the IPv6 forwarding function and 10GE uplink interfaces, and support H3C-specific cluster management, which simplifies your network management. S5500-SI series are designed as convergence and access devices for enterprise networks and metropolitan area networks (MANs), and can also be used for connecting server groups in data centers.
The feature-rich S5500-SI series switches support the following services:
z Broadband Internet access z Access of MAN and enterprise network users z Multimedia services, such as VoD z Delay-sensitive voice services, such as VoIP z Multicast audio and video services
S5500-SI series feature the following advantages:
z Providing full-Gigabit access ports z Providing 10GE ports (except for the S5500-20TP-SI switch) z Supporting IPv4/IPv6 dual-stack and hardware forwarding z Supporting jumbo frames z Supporting port security z Supporting link aggregation control protocol (LACP) z Supporting 4K VLANs z Supporting QACL z Supporting port-based/flow-based mirroring
Installation Manual H3C S5500-SI Complete Series Ethernet Switches Chapter 1 Product Overview
1-3
1.2 Introduction to S5500-SI Series Ethernet Switches
1.2.1 S5500-28C-SI Ethernet Switch
I. Front Panel
The S5500-28C-SI Ethernet switch provides 24 × 10/100/1000BASE-T Ethernet ports, four Gigabit SFP Combo ports and one Console port on the front panel.
Figure 1-1
shows the front panel appearance of the S5500-28C-SI Ethernet switch.
(1)
(2) (3) (4) (5) (6) (7) (8)
(9)
(10)
(1)
(2) (3) (4) (5) (6) (7) (8)
(9)
(10)
(1): 10/100/1000 BASE-T autosensing Ethernet port status LED (2): Gigabit SFP Combo port status LED (3): Console port (4): 7-segment digitron display (5): Power LED (6): DC power LED (7): LED for extended slot 1 (8): LED for extended slot 2 (9): Mode LED (10): Mode switching button
Figure 1-1 Front panel of the S5500-28C-SI Ethernet switch
Note:
For details about LEDs on the front panel, refer to section 1.3.1 “LEDs of S5500-28C-SI/S5500-52C-SI Switch”.
II. Rear Panel
(1) (2)
(3)
(4)
(5)
(1) (2)
(3)
(4)
(5)
(1): AC power input (2): DC power input (3): Grounding screw (4): Extended slot 1 (5): Extended slot 2
Figure 1-2 Rear panel of the S5500-28C-SI Ethernet switch
Installation Manual H3C S5500-SI Complete Series Ethernet Switches Chapter 1 Product Overview
1-4
III. Power Supply System
The S5500-28C-SI Ethernet switch supports both AC input and RPS 12 V input. The AC input and DC input can be used together to serve as backup for each other. In addition, either of them can be used alone. You can use only the RPS power supply recommended by H3C for DC input.
AC input: Rated voltage range: 100 VAC to 240 VAC, 50 Hz or 60 Hz Input voltage range: 90 VAC to 264 VAC, 50 Hz or 60 Hz RPS (DC) input: Rated voltage range: 10.8 VDC to 13.2 VDC
IV. Cooling System
The S5500-28C-SI Ethernet switch provides four fans for heat dissipation.
1.2.2 S5500-52C-SI Ethernet Switch
I. Front Panel
The S5500-52C-SI Ethernet switch provides 48 × 10/100/1000BASE-T Ethernet ports, four Gigabit SFP Combo ports and one Console port on the front panel.
Figure 1-3
shows the front panel appearance of the S5500-52C-SI Ethernet switch.
(1) (2)
(10)
(3) (6)
(7)
(8)
(9)
(4) (5)
(1) (2)
(10)
(3) (6)
(7)
(8)
(9)
(4) (5)
(1): 10/100/1000 BASE-T autosensing Ethernet port status LEDs (2): Console port (3): 7-segment digitron display (4): Mode switching button (5): Mode LED (6): Power LED (7): DC Power LED (8): LED for extended slot 1 (9): LED for extended slot 2 (10): Gigabit SFP Combo port status LED
Figure 1-3 Front panel of the S5500-52C-SI Ethernet switch
Installation Manual H3C S5500-SI Complete Series Ethernet Switches Chapter 1 Product Overview
1-5
Note:
For details about LEDs on the front panel, refer to section 1.3.1 “LEDs of S5500-28C-SI/S5500-52C-SI Switch”.
II. Rear Panel
(1)
(2)
(3)
(4)
(5)
(1)
(2)
(3)
(4)
(5)
(1): AC power input (2): DC power input (3): Grounding screw (4): Extended slot 1 (5): Extended slot 2
Figure 1-4 Rear panel of the S5500-52C-SI Ethernet switch
III. Power Supply System
The S5500-52C-SI Ethernet switch supports both AC input and RPS 12 V input. The AC input and DC input can be used together to serve as backup for each other. In addition, either of them can be used alone. You can use only the RPS power supply recommended by H3C for DC input.
AC power input: Rated voltage range: 100 VAC to 240 VAC, 50 Hz or 60 Hz Input voltage range: 90 VAC to 264 VAC, 50 Hz or 60 Hz RPS (DC) input: Rated voltage range: 10.8 VDC to 13.2 VDC
IV. Cooling System
The S5500-52C-SI Ethernet switch provides four fans for heat dissipation.
1.2.3 S5500-28C-PWR-SI Ethernet Switch
I. Front Panel
The S5500-28C-PWR-SI Ethernet switch provides 24 × 10/100/1000Base-T Ethernet ports, four Gigabit SFP Combo ports and one Console port on the front panel.
Figure
1-5 shows the front panel appearance of the S5500-28C-PWR-SI Ethernet switch.
Installation Manual H3C S5500-SI Complete Series Ethernet Switches Chapter 1 Product Overview
1-6
(1)
(2) (3) (4) (5) (6) (7) (8)
(9)
(10)
(1)
(2) (3) (4) (5) (6) (7) (8)
(9)
(10)
(1)
(2) (3) (4) (5) (6) (7) (8)
(9)
(10)
(1)
(2) (3) (4) (5) (6) (7) (8)
(9)
(10)
(1): 10/100/1000 BASE-T autosensing Ethernet port status LEDs (2): Gigabit SFP Combo port status LED (3): Console port (4): 7-segment digitron display (5): Power LED (6): DC Power LED (7): LED for extended slot 1 (8): LED for extended slot 2 (9): Mode LED (10): Mode switching button
Figure 1-5 Front panel of the S5500-28C-PWR-SI Ethernet switch
Note:
For details about LEDs on the front panel, refer to section 1.3.2 “LEDs of S5500-28C-PWR-SI/S5500-52C-PWR-SI Switch”.
II. Rear Panel
(1) (2)
(3)
(4)
(5)
(1) (2)
(3)
(4)
(5)
(1): DC power input (2): AC power input (3): Grounding screw (4): Extended slot 1 (5): Extended slot 2
Figure 1-6 Rear panel of the S5500-28C-PWR-SI Ethernet switch
III. Power Supply System
The S5500-28C-PWR-SI Ethernet switch supports both AC input and DC input. The AC input and DC input can be used together to serve as backup for each other . In addition, either of them can be used alone.
AC power input: Rated voltage range: 100 VAC to 240 VAC, 50 Hz or 60 Hz
Installation Manual H3C S5500-SI Complete Series Ethernet Switches Chapter 1 Product Overview
1-7
Input voltage range: 90 VAC to 264 VAC, 50 Hz or 60 Hz The S5500-28C-PWR-SI Ethernet switch supports only the external PoE power supply
recommended by H3C as the DC power. –48 VDC power cannot be used directly. Otherwise, the device may be destroyed.
DC input: Rated voltage range: –52 VDC to –55 VDC
IV. Cooling System
The S5500-28C-PWR-SI Ethernet switch provides six fans for heat dissipation.
1.2.4 S5500-52C-PWR-SI Ethernet Switches
I. Front Panel
The S5500-52C-PWR-SI Ethernet switch provides 48 × 10/100/1000Base-T Ethernet ports, four Gigabit SFP Combo ports and one Console port on the front panel.
Figure
1-7 shows the front panel appearance of the S5500-52C-PWR-SI Ethernet switch.
(1) (2)
(10 )
(3) (6)
(7)
(8 )
(9 )
(4) (5) (1) (2)
(10 )
(3) (6)
(7)
(8 )
(9 )
(4) (5) (1) (2)
(10 )
(3) (6)
(7)
(8 )
(9 )
(4) (5) (1) (2)
(10 )
(3) (6)
(7)
(8 )
(9 )
(4) (5)
(1): 10/100/1000 BASE-T autosensing Ethernet port status LEDs (2): Console port (3): 7-segment digitron display (4): Mode switching button (5): Mode LED (6): Power LED (7): DC Power LED (8): LED for extended slot 1 (9): LED for extended slot 2 (10): Gigabit SFP Combo port status LED
Figure 1-7 Front panel of the S5500-52C-PWR-SI Ethernet switch
Note:
For details about LEDs on the front panel, refer to section 1.3.2 “LEDs of S5500-28C-PWR-SI/S5500-52C-PWR-SI Switch”.
Installation Manual H3C S5500-SI Complete Series Ethernet Switches Chapter 1 Product Overview
1-8
II. Rear Panel
(1) (2 )
(3)
(4)
(5)
(1) (2 )
(3)
(4)
(5)
(1): DC power input (2): AC power input (3): Grounding screw (4): Extended slot 1 (5): Extended slot 2
Figure 1-8 Rear panel of the S5500-52C-PWR-SI Ethernet switch
III. Power Supply System
The S5500-52C-PWR-SI Ethernet switch supports both AC input and DC input. The AC input and DC input can be used together to serve as backup for each other . In addition, either of them can be used alone.
AC power input: Rated voltage range: 100 VAC to 240 VAC, 50 Hz or 60 Hz Input voltage range: 90 VAC to 264 VAC, 50 Hz or 60 Hz The S5500-52C-PWR-SI Ethernet switch supports only the external PoE power supply
recommended by H3C as the DC power. –48 V DC power cannot be used directly. Otherwise, the device may be destroyed.
DC input: Rated voltage range: –52 VDC to –55 VDC
IV. Cooling System
The S5500-52C-PWR-SI Ethernet switch provides six fans for heat dissipation.
1.2.5 S5500-20TP-SI Ethernet Switch
I. Front panel
The S5500-20TP-SI Ethernet switch provides 12 Gigabit SFP ports, 8 × 10/100/1000Base-T Ethernet ports, and one console port on th e front panel.
Figure 1-9
shows the front panel appearance of the S5500-20TP-SI Ethernet switch.
Installation Manual H3C S5500-SI Complete Series Ethernet Switches Chapter 1 Product Overview
1-9
(1)
(10)
(2)
(3)
(4)
(5)
(6)
(7)
(9)
(8)
(1): 1000/100 Mbps SFP port LED (2): 10/100/1000 Base-T autosensing Ethernet port LED (3): Console port (4): 7-segment digitron display (5): System LED (6): LED for power slot 1 (7): LED for power slot 2 (8): Mode LED (9): Mode switching button (10): Air intake vent
Figure 1-9 Front panel of the S5500-20TP-SI Ethernet switch
Note:
For details about LEDs on the front panel, refer to section 1.3.3 LEDs of S5500-20TP-SI Switch.
II. Rear panel
(1)
(2)
(4)
(3)
(1): Grounding screw (2): Power slot 1 (3): Power cable bail latch (4): Power slot 2
Figure 1-10 Rear panel of the S5500-20TP-SI Ethernet switch
III. Power supply system
The S5500-20TP-SI Ethernet switch adopts AC input. Rated voltage range: 100 VAC to 240 VAC, 50 Hz or 60 Hz Input voltage range: 90 VAC to 264 VAC, 50 Hz or 60 Hz
IV. Cooling system
The S5500-20TP-SI Ethernet switch provides five fans (three for the system, and one for each power module) for heat dissipation.
Installation Manual H3C S5500-SI Complete Series Ethernet Switches Chapter 1 Product Overview
1-10
1.3 Introduction to Front Panel LEDs
1.3.1 LEDs of S5500-28C-SI/S5500-52C-SI Switch
The S5500-28C-SI/S5500-52C-SI Ethernet switch provides LEDs on the front panel for your convenience to monitor the switch.
T able 1 -3 describes the meanings of th e LEDs. You can use the mode button on the panel to switch the display mode (rate mode or duplex mode) of LEDs.
Table 1-3 Description on the LEDs of the S5500-28C-SI/S5500-52C-SI Ethernet switch
LED Mark Status Description
Rate mode
Green, ON
The port status LEDs are showing the port rates.
Mode LED Mode
Duplex mode
Yellow, ON
The port status LEDs are showing the duplex mode of
the ports. Green, ON The switch starts normally. Green, blinking (1
Hz)
The system is performing
power-on self test (POST). Red, ON The system fails the POST. Yellow, blinking (1
Hz)
One or more ports fail the
POST.
Power LED PWR
OFF The switch is powered off.
Green, ON
Both AC and DC inputs are
normal.
Yellow, ON
The DC input is normal, but
the AC input is abnormal or
disconnected.
DC power LED RPS
OFF
The DC input is
disconnected.
Green, ON
The module is installed and
operates normally.
Yellow, blinking
The module is not supported
or is in trouble.
Module LED
Module( MOD)
OFF The module is not installed.
Installation Manual H3C S5500-SI Complete Series Ethernet Switches Chapter 1 Product Overview
1-11
LED Mark Status Description
POST running
Green, blinking
The POST ID of the
in-process test is displayed.
POST failed
Red, blinking
The POST ID of the failed
test blinks.
Loading software
Green, blinking
A light bar rotates clockwise
around the display during
the loading procedure.
Fan failure
Red, ON
An “F” is displayed.
Overtem perature alarm
Red, ON
A “t” is displayed.
7-segment digitron display
Unit
Cluster status
Green, ON
A “C” is displayed if this is a
command switch.
An “S” is displayed if this is a
member switch.
A “c” is displayed if this is a
candidate switch.
A “1” is displ ayed when the
switch operates
independently.
(The default display is “c”,
that is, the device is
candidate switch by default.)
Installation Manual H3C S5500-SI Complete Series Ethernet Switches Chapter 1 Product Overview
1-12
LED Mark Status Description
Green
The port works at the rate of
1000 Mbps; the LED blinks
quickly when the port is
sending or receiving data.
Yellow
The port works at the rate of
10/100 Mbps; the LED blinks
quickly when the port is
sending or receiving data.
Yellow, blinking (3 Hz)
POST fails on the port.
Rate mode
OFF The port is not connected.
Green
The port works in full duplex
mode; the LED blinks quickly
when the port is sending or
receiving data..
Yellow
The port works in half duplex
mode; the LED blinks quickly
when the port is sending or
receiving data..
Yellow, blinking (3 Hz)
POST fails on the port.
10/100/1000BAS E-T Ethernet port status LED
Duplex mode
OFF The port is not connected.
Green
The port works at the rate of
1000 Mbps; the LED blinks
quickly when the port is
sending or receiving data.
Yellow, blinking (3 Hz)
POST fails on the port.
1000Base SFP port status LED
This LED is not influence d by the mode button
OFF The port is not connected.
1.3.2 LEDs of S5500-28C-PWR-SI/S5500-52C-PWR-SI Switch
The S5500-28C-PWR-SI/S5500-52C-PWR-SI Ethernet switch provides LEDs on the front panel for your convenience to monitor the switch.
Table 1-4 describes the meanings of the LEDs. You can use the Mode button on the panel to switch the display mode (rate mode, duplex mode, or PoE mode) of LEDs.
Installation Manual H3C S5500-SI Complete Series Ethernet Switches Chapter 1 Product Overview
1-13
Table 1-4 Description on the LEDs of the S5500-28C-PWR-SI/S5500-52C-PWR-SI Ethernet switch
LED Mark Status Description
Rate mode
Green, ON
The port status LEDs are showing the port rate.
Duplex mode
Yellow, ON
The port status LEDs are showing the duplex mode of the port.
Mode LED Mode
PoE mode
Green, blinking (1 Hz)
The port status LEDs are showing the PoE status of the
port. Green, ON The switch starts normally. Green, blinking (1
Hz)
The system is performing
power-on self test (POST). Red, ON The POST fails the POST. Yellow, blinking (1
Hz)
One or more ports fail the
POST.
Power LED PWR
OFF The switch is powered off.
Green, ON
Both AC and DC inputs are
normal.
Yellow, ON
The DC input is normal but the
AC input is abnormal or
disconnected.
DC power LED RPS
OFF The DC input is disconnected.
Green, ON
The module is installed and
operates normally.
Yellow, blinking
The module is not supported or
is in trouble.
Module LED
Module (MOD)
OFF The module is not installed.
Installation Manual H3C S5500-SI Complete Series Ethernet Switches Chapter 1 Product Overview
1-14
LED Mark Status Description
POST running
Green, blinking
The POST ID of the in-process
test is displayed.
POST failed
Red, blinking
The POST ID of the failed test
blinks.
Loading software
Green, blinking
A light bar rotates clockwise
around the display during the
loading procedure.
Fan failure
Red, ON
An “F” is displayed.
Overtemp erature alarm
Red, ON
A “t” is displayed.
Cluster status
Green, ON
A “C” is displayed if there i s a
command switches.
An “S” is displayed if there is a
member switches.
A “c” is displayed if there is a
candidate switches.
A “1” is displ ayed when the
switch operates independently.
(The default display is “c”, that
is, the device is candidate
switch by default.)
7-segment digitron display
Unit
PoE mode
Green, ON
Show the utilization of the
power
0 - 20%
21 - 40%
41 - 60%
61 - 80%
81 - 100%
Installation Manual H3C S5500-SI Complete Series Ethernet Switches Chapter 1 Product Overview
1-15
LED Mark Status Description
Green
The port works at the rate of
1000 Mbps; the LED blinks
quickly when the port is sending
or receiving data.
Yellow
The port works at the rate of
10/100 Mbps; the LED blinks
quickly when the port is sending
or receiving data.
Yellow, blinking (3 Hz)
POST fails on the port.
Rate mode
OFF The port is not connected.
Green
The port works in full duplex
mode; the LED blinks quickly
when the port is sending or
receiving data.
Yellow
The port works in half duplex
mode; the LED blinks quickly
when the port is sending or
receiving data.
Yellow, blinking (3 Hz)
POST fails on the port.
Duplex mode
OFF The port is not connected. Green,
ON
The port supplies power
normally
Green, blinking (1 Hz)
The required power of the
attached devices has exceeded
the maximum power that the
port can supply.
The total power that the switch
supplies has reached the
maximum power, so the port
does not supply power any
more.
Yellow, ON
The devices attached to the port
are not powered devices (PDs),
so the port does not supply
power.
The PoE power fails, so the port
cannot supply power.
Yellow, blinking (3 Hz)
POST fails on the port
10/100/1000B ASE-T Ethernet port status LED
PoE mode
OFF The port does not supply power.
Installation Manual H3C S5500-SI Complete Series Ethernet Switches Chapter 1 Product Overview
1-16
LED Mark Status Description
Green
The port works at the rate of
1000 Mbps; the LED blinks
quickly when the port is sending
or receiving data.
Yellow, blinking (3 Hz)
POST fails on the port.
1000Base SFP port status LED
This LED is not influenced by the mode button
OFF The port is not connected.
1.3.3 LEDs of S5500-20TP-SI Switch
The S5500-20TP-SI Ethernet switch provides LEDs on the front panel for your convenience to monitor the switch.
Table 1-5 describes the meanin gs of the LEDs. You can use the Mode button on the panel to switch the display mode (rate mode, or duplex mode) of LEDs.
Table 1-5 Description of LEDs on the front panel of the S5500-20TP-SI Ethernet Switch
LED Mark Status Description
Speed
Solid green
Rate of the port
Mode LED Mode
Duplex
Solid yellow
Duplex of the port
Solid green
The switch is started normally.
Flashing green (1 Hz)
The system is running a POST.
Solid red
The system fails the POST or a power failure occurs.
Flashing yellow (1 Hz)
Some ports fail the POST or a port failure occurs.
System power LED
SYS
OFF The power is disconnected.
Solid green
A power module is installed in the power module slot and the output is normal.
Solid yellow
A power module is installed in the power module slot but there is an output failure.
LED for power module slot 1
PWR1
OFF
No power module is installed in the power module slot or no power is input.
Installation Manual H3C S5500-SI Complete Series Ethernet Switches Chapter 1 Product Overview
1-17
LED Mark Status Description
Solid green
A power module is installed in the power module slot and the output is normal.
Solid yellow
A power module is installed in the power module slot but there is an output failure.
LED for power module slot 2
PWR2
OFF
No power module is installed in the power module slot or no power is input.
Solid green
The module is in position and works normally.
Flashing yellow
The switch does not support the module or a module failure occurs.
Module LED MOD
OFF No module is installed.
POST running
The power LED flashes green.
The LED displays the POST test ID.
POST failed
The power LED flashes red.
The LED flashes the POST test ID of the failed test.
Software loading
The power LED flashes green.
A bar rotates clockwise around the LED.
Fan failure
The power LED is solid red.
The LED displays F.
Over-tem perature alarm
The power LED is solid red.
The LED displays t.
7-segment digital LED
Unit
Cluster status
Solid green
For a command switch, the LED displays C.
For a member switch, the LED displays S.
For a candidate switch, the LED displays c.
The LED displays 1 if there is only one unit.
Installation Manual H3C S5500-SI Complete Series Ethernet Switches Chapter 1 Product Overview
1-18
LED Mark Status Description
Green
A 1000 Mbps link is present. When data is being received or sent, the LED flashes at a high frequency.
Yellow
A 10/100 Mbps link is present. When data is being received or sent, the LED flashes at a high frequency.
Flashing yellow (3 Hz)
The port fails the POST.
Speed
OFF No link is present.
Green
The port operates in the full duplex mode. When data is being received or sent, the LED flashes at a high frequency.
Yellow
The port operates in the half duplex mode. When data is being received or sent, the LED flashes at a high frequency.
Flashing yellow (3 Hz)
The port fails the POST.
Auto-sensing 10/100/1000Bas e-T Ethernet port status LED
Duplex
OFF No link is present.
Green
A 1000 Mbps link is present. When data is being received or sent, the LED flashes every 30 milliseconds.
Flashing yellow (3 Hz)
The port fails the POST.
SFP port status LED (1000 Mbps)
The Mode button has no effect on the LED.
OFF No link is present.
Installation Manual H3C S5500-SI Complete Series Ethernet Switches Chapter 1 Product Overview
1-19
1.4 System Specifications of the S5500-SI Series
Table 1-6 System specifications of the S5500-SI series
Item
S5500-28C-
SI
S5500-52C
-SI
S5500-28C-PWR
-SI
S5500-52C-PW
R-SI
Physical dimensions
(H × W × D)
43.6 × 440 × 300 mm (1.72 × 17.3 × 11.8 in.)
43.6 × 440 × 420 mm (1.72 × 17.3 ×
16.5 in.)
Weight
4 kg (8.8 lb)
4.5 kg (9.9 lb)
6 kg (13.2 lb) 6.5 kg (14.3 lb)
Management port
One console port
GE ports on the front panel
24 × 10/100/1000 Mbps electric ports
Four Gigabit SFP Combo ports
48 × 10/100/100 0 Mbps electric ports
Four Gigabit SFP Combo ports
24 × 10/100/1000 Mbps electric ports
Four Gigabit SFP Combo ports
48 × 10/100/1000 Mbps electric ports
Four Gigabit SFP Combo ports
Optional interface modules
One-port 10 GE XFP interface module Dual-port 10 GE XFP interface module Short-haul dual-port 10GE CX4 interface module
AC
Rated voltage range: 100 VAC to 240 VAC, 50 Hz or 60 Hz Input voltage range: 90 VAC to 264 VAC, 50 Hz or 60 Hz
Input volta ge
DC
Rated voltage range:
10.8 VDC to 13.2 VDC
Rated voltage range: –52 VDC to –55 VDC
Power consumption (full load)
80 W
120 W
455 W, with 85 W of system power consumption and 370 W of PoE power
500 W when RPS is not connected, with 130 W of system power consumption and 370 W of PoE power
870 W when RPS is connected, with 130 W of system power consumption and 740 W of PoE power
Installation Manual H3C S5500-SI Complete Series Ethernet Switches Chapter 1 Product Overview
1-20
Item
S5500-28C-
SI
S5500-52C
-SI
S5500-28C-PWR
-SI
S5500-52C-PW
R-SI
Operating temperature
0°C to 45°C (32°F to 113°F)
Relative humidity (noncondens ing)
10% to 90%
Table 1-7 System specifications of the S5500-20TP-SI Ethernet switch
Item S5500-20TP-SI
Physical dimensions
(H × W × D)
43.6 × 440 × 360 mm (1.72 × 17.3 × 14.2 in.)
Weight
5.5 kg (12.1 lb)
Management port
One console port
GE ports on the front panel
12 Gigabit SFP Combo ports 8 × 10/100/1000 Mbps electric ports
Optional interface modules
Interface modules not supported
AC
Rated voltage range: 100 VAC to 240 VAC, 50 or 60 Hz Input voltage range: 90 VAC to 264 VAC, 50 or 60 Hz
Input volta ge
DC Not supported
Power consumption (full load)
65 W
Operating temperature
0°C to 45°C (32°F to 113°F)
Relative humidity (noncondens ing)
10% to 90%