H3C S5100-EI, S5100-24P-SI, S5100-8P-SI, S5100-16P-SI, S5100-48P-SI Installation Manual

...
Page 1
H3C S5100-SI/EI Series Ethernet Switches
Installation Manual
Hangzhou H3C Technologies Co., Ltd. http://www.h3c.com
Manual Version: 20080123-C-1.05
Page 2
Copyright © 2007-2008, Hangzhou H3C Techn ologies Co ., Ltd. a nd its licensors
All Rights Reserved
No part of this manual may be reproduced or transmitted in any form or by any means without prior written consent of Hangzhou H3C Technologies Co., Ltd.
Trademarks
H3C, , Aolynk, , H3Care,
, TOP G, , IRF, NetPilot, Neocean, NeoVTL, SecPro, SecPoint, SecEngine, SecPath, Comware, Secware, Storware, NQA, VVG, V
2
G, VnG, PSPT, XGbus, N-Bus, TiGem, InnoVision and
HUASAN are trademarks of Hangzhou H3C Technologies Co., Ltd. All other trademarks that may be mentioned in this manual are the property of their
respective owners.
Notice
The information in this document is subject to change without notice. Every effort has been made in the preparation of this document to ensure accuracy of the content s, but all statements, information, and recommendations in this document do not constitute the warranty of any kind, express or implied.
To obtain the latest information, please access: http://www. h3c.com
Technical Support
customer_service@h3c.com http://www. h3c.com
Page 3
About This Manual
Related Documentation
In addition to this manual, each H3C S5100-SI/EI Series Ethernet Switches documentation set includes the following:
Manual Description
H3C S5100-SI/EI Series Ethernet Switches Operation Manual
It is used for assisting the users in data configurations and typical applications.
H3C S5100-SI/EI Series Ethernet Switches Command Manual
It is used for assisting the users in using various commands.
Organization
H3C S5100-SI/EI Series Ethernet Switches Installation Manual is organized as follows:
Chapter Contents
1 Product Overview Introduces the characteristics and technical
specifications of S5100-SI/EI Series Ethernet Switches.
2 Preparing for Installation Introduces the installation preparation and precaution
of S5100-SI/EI Series Ethernet Switches.
3 Installing the Switch Introduces the procedures to install an S5100-SI/EI
Series Ethernet Switch, including the setup of the mainframe, cards and cables.
4 Powering on the Switch for the First Time
Introduces the booting process of an S5100-SI/EI Series Ethernet Switch, including the power-on booting of the switch and the system initialization.
5 Boot ROM and Host Software Loading
Introduces how to load BootROM and host software for an S5100-SI/EI Series Ethernet Switch.
6 Maintenance and Troubleshooting
Introduces the problems that might occur during the installation and the booting of an S5100-SI/EI Series Ethernet Switch and the related solution.
7 Appendix A Introduces lightning protection of S5100-SI/EI Series
Ethernet Switches.
Page 4
Conventions
The manual uses the following conventions:
I. GUI conventions
Convention Description
< >
Button names are inside angle brackets. For example, click <OK>.
[ ]
Window names, menu items, data table and field names are inside square brackets. For example, pop up the [New User] window.
/
Multi-level menus are separated by forward slashes. For example, [File/Create/Folder].
II. Symbols
Convention Description
Warning
Means reader be extremely careful. Improper operation may cause bodily injury.
Caution
Means reader be careful. Improper operation may cause data loss or damage to equipment.
Note Means a complementary description.
Environmental Protection
This product has been designed to comply with the requirements on environmental protection. For the proper storage, use and disposal of this product, national laws and regulations must be observed.
Page 5
Installation Manual H3C S5100-SI/EI Series Ethernet Switches Table of Contents
i
Table of Contents
Chapter 1 Product Overview........................................................................................................1-1
1.1 Preface...............................................................................................................................1-1
1.2 S5100-SI Series Ethernet Switches...................................................................................1-2
1.2.1 S5100-8P-SI Ethernet Switch ................................................................................. 1-2
1.2.2 S5100-16P-SI Ethernet Switch ............................................................................... 1-4
1.2.3 S5100-24P-SI Ethernet Switch ............................................................................... 1-6
1.2.4 S5100-48P-SI Ethernet Switch ............................................................................... 1-7
1.3 S5100-EI Series Ethernet Switches...................................................................................1-8
1.3.1 S5100-8P-EI Ethernet Switch ................................................................................. 1-8
1.3.2 S5100-16P-EI Ethernet Switch ............................................................................... 1-9
1.3.3 S5100-24P-EI Ethernet Switch ............................................................................. 1-10
1.3.4 S5100-48P-EI Ethernet Switch ............................................................................. 1-12
1.3.5 S5100-26C-EI Ethernet Switch.............................................................................1-13
1.3.6 S5100-50C-EI Ethernet Switch.............................................................................1-15
1.3.7 S5100-8P-PWR-EI Ethernet Switch...................................................................... 1-16
1.3.8 S5100-16P-PWR-EI Ethernet Switch.................................................................... 1-18
1.3.9 S5100-26C-PWR-EI Ethernet Switch....................................................................1-20
1.3.10 S5100-50C-PWR-EI Ethernet Switch..................................................................1-21
1.4 LEDs................................................................................................................................1-23
1.4.1 Power LED (PWR)................................................................................................1-23
1.4.2 DC Power Supply LED (RPS)...............................................................................1-24
1.4.3 Mode LED ............................................................................................................. 1-24
1.4.4 Gigabit Autosensing Ethernet Port Status LEDs...................................................1-25
1.4.5 Gigabit SFP Port Status LED................................................................................1-26
1.4.6 Module LED...........................................................................................................1-27
1.4.7 7-Segment Digitron Display .................................................................................. 1-28
1.5 System Features of the S5100 Series.............................................................................1-30
1.5.1 System Features of the S5100-SI Series.............................................................. 1-30
1.5.2 System Features of the S5100-EI Series.............................................................. 1-31
1.6 Ordering SFP/XFP/XENPAK Interface Modules ............................................................. 1-34
1.7 Ordering 10 G Stack Interface Modules..........................................................................1-35
1.8 Ordering Stack Cables..................................................................................................... 1-36
1.9 Ordering DC Power cords................................................................................................1-36
Chapter 2 Preparing for Installation............................................................................................ 2-1
2.1 Safety Precautions............................................................................................................. 2-1
2.2 Installation Site...................................................................................................................2-1
2.2.1 Temperature/Humidity.............................................................................................2-1
Page 6
Installation Manual H3C S5100-SI/EI Series Ethernet Switches Table of Contents
ii
2.2.2 Cleanness ............................................................................................................... 2-2
2.2.3 Electromagnetic Susceptibility ................................................................................ 2-2
2.2.4 Safety in Use of Laser.............................................................................................2-3
2.3 Installation Tools................................................................................................................2-3
Chapter 3 Installing the Switch.................................................................................................... 3-1
3.1 Rack-Mounting the Switch.................................................................................................3-1
3.1.1 Introduction to Mounting Ear...................................................................................3-2
3.1.2 Introduction to Guide Rail........................................................................................3-4
3.1.3 Using Front Mounting Ears to Install a Switch........................................................3-4
3.1.4 Use Front Mounting Ears and a Tray......................................................................3-5
3.1.5 Use Front and Rear Mounting Ears........................................................................3-6
3.1.6 Use Front Mounting Ears and Guide Rails ............................................................. 3-9
3.2 Desk Mounting.................................................................................................................3-12
3.3 Wall Mounting..................................................................................................................3-12
3.4 Magnet Mounting............................................................................................................. 3-13
3.5 Connecting Power Cord and Grounding Wire.................................................................3-16
3.5.1 Connecting AC Power Cord..................................................................................3-16
3.5.2 Connecting DC Power Cord.................................................................................. 3-17
3.5.3 Connecting Grounding Wire..................................................................................3-19
3.6 Connecting Console Cable..............................................................................................3-21
3.6.1 Console Cable....................................................................................................... 3-21
3.6.2 Connecting Console Cable ................................................................................... 3-22
3.7 Installing and Removing Optional Interface Modules...................................................... 3-23
3.7.1 XFP Interface Module ...........................................................................................3-23
3.7.2 Stack Module.........................................................................................................3-25
3.7.3 XENPAK Optical Module....................................................................................... 3-26
3.8 Installing and Removing Dedicated Stack Cables........................................................... 3-28
3.8.1 Introduction............................................................................................................3-28
3.8.2 Installation.............................................................................................................3-28
3.8.3 Removal................................................................................................................3-28
3.9 Verifying the Installation................................................................................................... 3-29
Chapter 4 Powering on the Switch for the First Time................................................................4-1
4.1 Set up the Configuration Environment............................................................................... 4-1
4.2 Connecting the Console Cable..........................................................................................4-1
4.3 Setting Terminal Parameters.............................................................................................4-1
4.4 Booting the Switch............................................................................................................. 4-4
4.4.1 Checking before Powering on the Switch ............................................................... 4-4
4.4.2 Powering on the Switch........................................................................................... 4-4
4.4.3 Changing the Startup Mode....................................................................................4-6
Chapter 5 Boot ROM and Host Software Loading ..................................................................... 5-1
5.1 Introduction to Loading Modes .......................................................................................... 5-1
Page 7
Installation Manual H3C S5100-SI/EI Series Ethernet Switches Table of Contents
iii
5.2 Local Software Loading.....................................................................................................5-1
5.2.1 Boot Menu...............................................................................................................5-2
5.2.2 Loading Software Using XModem Through Console Port......................................5-3
5.2.3 Loading Software Using TFTP through Ethernet Port............................................5-8
5.2.4 Loading Software Using FTP Through Ethernet Port............................................. 5-9
5.3 Remote Software Loading...............................................................................................5-11
5.3.1 Remote Loading Using FTP..................................................................................5-11
5.3.2 Remote Loading Using TFTP................................................................................5-13
Chapter 6 Maintenance and Troubleshooting............................................................................ 6-1
6.1 Software Loading Failure................................................................................................... 6-1
6.2 Missing Password..............................................................................................................6-1
6.2.1 Missing user password............................................................................................ 6-1
6.2.2 Missing Boot ROM Password ................................................................................. 6-2
6.3 Power Supply Failure......................................................................................................... 6-2
6.4 Configuration System Failure ............................................................................................ 6-2
Page 8
Installation Manual H3C S5100-SI/EI Series Ethernet Switches Chapter 1 Product Overview
1-1
Chapter 1 Product Overview
1.1 Preface
H3C S5100 Series Ethernet Switches (hereinafter referred to as the H3C S5100 series) are Gigabit Ethernet switching products developed by H3C Technology Co., Ltd. The H3C S5100 series provide a variety of service features. The H3C S5100 series are designed as convergence and access devices for intranets and metropolitan area networks (MANs), and can also be used for connecting data center server clusters.
The H3C S5100 series come in two series: S5100-SI and S5100-EI, which are available in the following models:
Table 1-1 H3C S5100-SI/EI series
Series Model
10/100/100
0Base-T
autosensin
g Ethernet
port
1000Base-X
SFP port
Console
port
S5100-8P-SI 8 2 S5100-16P-SI 16 S5100-24P-SI 24
S5100-SI
S5100-48P-SI 48
4
S5100-8P-EI 8 2 S5100-16P-EI 16 S5100-24P-EI 24 S5100-48P-EI 48 S5100-26C-EI 24 S5100-50C-EI 48
4
S5100-8P-PWR-EI 8 2 S5100-16P-PWR-EI 16 S5100-26C-PWR-EI 24
S5100-EI
S5100-50C-PWR-EI 48
4
1
An SFP port and its corresponding 10/100/100 0Base-T autose nsing Ethernet port form a Combo port. That is, only one of the two ports forming the Combo port can be used at
Page 9
Installation Manual H3C S5100-SI/EI Series Ethernet Switches Chapter 1 Product Overview
1-2
a time. Table 1-2 shows the mapping relations between the ports forming the Combo port.
Table 1-2 Mapping relations between the ports forming the Combo port
Model 1000Base-X SFP port
10/100/1000Base-T
autosensing Ethernet port
17 14 18 16 19 13
S5100-16P-SI S5100-16P-EI S5100-16P-PWR-EI
20 15 25 22 26 24 27 21
S5100-24P-SI S5100-24P-EI S5100-26C-EI S5100-26C-PWR-EI
28 23 49 46 50 48 51 45
S5100-48P-SI S5100-48P-EI S5100-50C-EI S5100-50C-PWR-EI
52 47
1.2 S5100-SI Series Ethernet Switches
1.2.1 S5100-8P-SI Ethernet Switch
I. Front Panel
An S5100-8P-SI Ethernet switch provides 8 x 10/100/1000Base-T autosensing Ethernet ports, two 1000Base-X SFP ports, and one console port on the front panel. Figure 1-1 shows the front panel of an S5100-8P-SI Ethernet switch.
Page 10
Installation Manual H3C S5100-SI/EI Series Ethernet Switches Chapter 1 Product Overview
1-3
(1): 10/100/1000Base-T autosensing Ethernet port status LEDs (2): 1000Base-X SFP port status LED (3): Console port (4): 7-segment digitron display (5): Power LED (6): Ethernet port mode switching LED (7): Port status LED mode switch
Figure 1-1 Front panel of an S5100-8P-SI Ethernet switch
II. Rear Panel
(1): AC power input (2): Grounding terminal
Figure 1-2 Rear panel of an S5100-8P-SI Ethernet switch
III. Side panel
An S5100-8P-SI Ethernet switch provides a lock hole for locking the switch to a secure object for theft prevention.
The lock hole is on the back of the left side panel, as sho wn in
Figure 1-3.
Page 11
Installation Manual H3C S5100-SI/EI Series Ethernet Switches Chapter 1 Product Overview
1-4
(1)
(1): Lock hole for theft prevention
Figure 1-3 Lock hole for theft prevention on the back of the left side panel
Note:
The lock hole cannot be used when the screw hole above it is in use.
IV. Power supply system
AC input: Rated voltage range: 100 VAC to 240 VAC; 50 Hz or 60 Hz Max voltage range: 90 VAC to 264 VAC; 47 Hz to 63 Hz
V. Cooling system
An S5100-8P-SI Ethernet switch provides one fan for heat dissipation.
1.2.2 S5100-16P-SI Ethernet Switch
I. Front panel
An S5100-16P-SI Ethernet switch provides 16 x 10/100/1000Base-T autosensing Ethernet ports, four 1000Base-X SFP po rts, and one console port on the front panel. An SFP port and its corresponding 10/100/1000Base-T autosensing Ethernet port form a Combo port. That is, only one of the two ports forming the Combo p ort can be used at a time.
T able 1-2 sho ws the mapping relations between the port s forming the Combo port.
Figure 1-4 shows the front panel of an S5100-16P-SI Ethernet switch.
Page 12
Installation Manual H3C S5100-SI/EI Series Ethernet Switches Chapter 1 Product Overview
1-5
(1): 10/100/1000Base-T autosensing Ethernet port status LEDs (2): 1000Base-X SFP port status LED (3): Consol e port (4): 7-segment digitron display (5): Power LED (6): Ethernet port mode switching LED (7): Port status LED mode switch
Figure 1-4 Front panel of an S5100-16P-SI Ethernet switch
II. Rear panel
(1): AC power input (2): Grounding terminal
Figure 1-5 Rear panel of an S5100-16P-SI Ethernet switch
III. Side panel
An S5100-16P-SI Ethernet switch provides a lock hole for locking the switch to a secure object for theft prevention.
The lock hole is on the back of the left side panel, as sho wn in
Figure 1-3.
Note:
The lock hole cannot be used when the screw hole above it is in use.
IV. Power supply system
AC input: Rated voltage range: 100 VAC to 240 VAC; 50 Hz or 60 Hz Max voltage range: 90 VAC to 264 VAC; 47 Hz to 63 Hz
Page 13
Installation Manual H3C S5100-SI/EI Series Ethernet Switches Chapter 1 Product Overview
1-6
V. Cooling system
An S5100-16P-SI Ethernet switch provides one fan for heat dissipation.
1.2.3 S5100-24P-SI Ethernet Switch
I. Front panel
An S5100-24P-SI Ethernet switch provides 24 x 10/100/1000Base-T autosensing Ethernet ports, four 1000Base-X SFP po rts, and one console port on the front panel. An SFP port and its corresponding 10/100/1000Base-T autosensing Ethernet port form a Combo port. That is, only one of the two ports forming the Combo p ort can be used at a time.
T able 1-2 sho ws the mapping relations between the port s forming the Combo port.
Figure 1-6 shows the front panel of an S5100-24P-SI Ethernet switch.
(1): 10/100/1000Base-T autosensing Ethernet port status LEDs (2): 1000Base-X SFP port status LED (3): Console port (4): 7-segment digitron display (5): Power LED (6): Ethernet port mode switching LED (7): Port status LED mode switch
Figure 1-6 Front panel of an S5100-24P-SI Ethernet switch
II. Rear panel
(1): AC power input (2): Grounding terminal
Figure 1-7 Rear panel of an S5100-24P-SI Ethernet switch
III. Power supply system
AC input: Rated voltage range: 100 VAC to 240 VAC; 50 Hz or 60 Hz Max voltage range: 90 VAC to 264 VAC; 47 Hz to 63 Hz
Page 14
Installation Manual H3C S5100-SI/EI Series Ethernet Switches Chapter 1 Product Overview
1-7
IV. Cooling system
An S5100-24P-SI Ethernet switch provides one fan for heat dissipation.
1.2.4 S5100-48P-SI Ethernet Switch
I. Front panel
An S5100-48P-SI Ethernet switch provides 48 x 10/100/1000Base-TX autosensing Ethernet ports, four 1000Base-X SFP ports, and one con sole port. An SFP port and its corresponding 10/100/1000Base-T autosen sing Ethernet port form a Combo port. That is, only one of the two ports forming the Combo port can be used at a time.
Table 1-2
shows the mapping relations between the ports forming the Combo port.
Figure 1-8
shows the front panel of an S5100-48P-SI Ethernet switch.
(1)(1) (2) (3) (4) (5) (6)
(7)
(1): 10/100/1000Base-T autosensing Ethernet port status LEDs (2): Console port (3): 7-segment digitron display (4): Port status LED mode switch (5): Ethernet port mode switching LED (6): Power LED (7): 1000Base-X SFP port status LED
Figure 1-8 Front panel of an S5100-48P-SI Ethernet switch
II. Rear panel
(1): AC power input (2): Grounding terminal
Figure 1-9 Rear panel of an S5100-48P-SI Ethernet switch
III. Power supply system
AC input: Rated voltage range: 100 VAC to 240 VAC, 50 Hz or 60 Hz Max voltage range: 90 VAC to 264 VAC, 47 Hz to 63 Hz
Page 15
Installation Manual H3C S5100-SI/EI Series Ethernet Switches Chapter 1 Product Overview
1-8
IV. Cooling system
An S5100-48P-SI Ethernet switch provides two fans for heat dissipation.
1.3 S5100-EI Series Ethernet Switches
1.3.1 S5100-8P-EI Ethernet Switch
I. Front panel
An S5100-8P-EI Ethernet switch provides 8 x 10/100/1000Base-T autosensing Ethernet ports, two 1000Base-X SFP ports, and one console port on the front panel. Figure 1-10 shows the front panel of an S5100-8P-EI Ethernet switch.
(1): 10/100/1000Base-T autosensing Ethernet port status LEDs (2): 1000Base-X SFP port status LED (3): Consol e port (4): 7-segment digitron display (5): Power LED (6): Ethernet port mode switching LED (7): Port status LED mode switch
Figure 1-10 Appearance of an S5100-8P-EI Ethernet switch
II. Rear panel
(1): AC power input (2): Grounding terminal
Figure 1-11 Rear panel of an S5100-8P-EI Ethernet switch
III. Side panel
An S5100-8P-EI Ethernet switch provides a lock hole for locking the switch to a secure object for theft prevention.
Page 16
Installation Manual H3C S5100-SI/EI Series Ethernet Switches Chapter 1 Product Overview
1-9
The lock hole is on the back of the left side panel, as sho wn in Figure 1-3.
Note:
The lock hole cannot be used when the screw hole above it is in use.
IV. Power supply system
AC input: Rated voltage range: 100 VAC to 240 VAC, 50 Hz or 60 Hz Max voltage range: 90 VAC to 264 VAC, 47 Hz to 63 Hz
V. Cooling system
An S5100-8P-EI Ethernet switch provides one fan for heat dissipation.
1.3.2 S5100-16P-EI Ethernet Switch
I. Front panel
An S5100-16P-EI Ethernet switch provides 16 x 10/100/1000Base-T autosensing Ethernet ports, four 1000Base-X SFP po rts, and one console port on the front panel. An SFP port and its corresponding 10/100/1000Base-T autosensing Ethernet port form a Combo port. That is, only one of the two ports forming the Combo p ort can be used at a time.
T able 1-2 sho ws the mapping relations between the port s forming the Combo port.
Figure 1-12 shows the front panel of an S5100-16P-EI Ethernet switch.
(1): 10/100/1000Base-T autosensing Ethernet port status LEDs (2): 1000Base-X SFP port status LED (3): Console port (4): 7-segment digitron display (5): Power LED (6): Ethernet port mode switching LED (7): Port status LED mode switch
Figure 1-12 Front panel of an S5100-16P-EI Ethernet switch
Page 17
Installation Manual H3C S5100-SI/EI Series Ethernet Switches Chapter 1 Product Overview
1-10
II. Rear panel
(1): AC power input (2): Grounding terminal
Figure 1-13 Rear panel of an S5100-16P-EI Ethernet switch
III. Side panel
An S5100-16P-EI Ethernet switch provides a lock hole for locking the switch to a secure object for theft prevention.
The lock hole is on the back of the left side panel, as sho wn in
Figure 1-3.
Note:
The lock hole cannot be used when the screw hole above it is in use.
IV. Power supply system
AC input: Rated voltage range: 100 VAC to 240 VAC; 50 Hz or 60 Hz Max voltage range: 90 VAC to 264 VAC; 47 Hz to 63 Hz
V. Cooling system
An S5100-16P-EI Ethernet switch provides one fan for heat dissipation.
1.3.3 S5100-24P-EI Ethernet Switch
I. Front panel
An S5100-24P-EI Ethernet switch provides 24 x 10/100/1000Base-T autosensing Ethernet ports, four 1000Base-X SFP po rts, and one console port on the front panel. An SFP port and its corresponding 10/100/1000Base-T autosensing Ethernet port form a Combo port. That is, only one of the two ports forming the Combo p ort can be used at a time.
T able 1-2 sho ws the mapping relations between the port s forming the Combo port.
Figure 1-12 shows the front panel of an S5100-24P-EI Ethernet switch.
Page 18
Installation Manual H3C S5100-SI/EI Series Ethernet Switches Chapter 1 Product Overview
1-11
(1): 10/100/1000Base-T autosensing Ethernet port status LEDs (2): 1000Base-X SFP port status LED (3): Console port (4): 7-segment digitron display (5): DC power LED (6): Power LED (7): Ethernet port mode switching LED (8): Port status LED mode switch
Figure 1-14 Front panel of an S5100-24P-EI Ethernet switch
II. Rear panel
(1): AC power input (2): DC power input (3): Grounding terminal
Figure 1-15 Rear panel of an S5100-24P-EI Ethernet switch
III. Power supply system
An S5100-24P-EI switch provides AC power input and RPS DC input. The AC and DC power inputs can be used at the same time, acting as backup for each other. Alternatively , you can use either the AC power input alo ne or the DC power input alone. Make sure you use an RPS module recommended by H3C as the DC power input.
z AC input:
Rated voltage range: 100 VAC to 240 VAC; 50 Hz or 60 Hz Max voltage range: 90 VAC to 264 VAC; 47 Hz to 63 Hz
z DC input
Rated voltage range: -48 VDC to -60 VDC Max voltage range: -36 VDC to -72 VDC
Page 19
Installation Manual H3C S5100-SI/EI Series Ethernet Switches Chapter 1 Product Overview
1-12
Note:
For the description of RPS and the auxiliary cables, see RPS500-A3 User Manual and RPS1000-A3 User Manual.
IV. Cooling system
An S5100-24P-EI Ethernet switch provides one fan for heat dissipation.
1.3.4 S5100-48P-EI Ethernet Switch
I. Front panel
An S5100-48P-EI Ethernet switch provides 48 x 10/100/1000Base-T autosensing Ethernet ports, four 1000Base-X SFP po rts, and one console port on the front panel. An SFP port and its corresponding 10/100/1000Base-T autosensing Ethernet port form a Combo port. That is, only one of the two ports forming the Combo p ort can be used at a time.
T able 1-2 sho ws the mapping relations between the port s forming the Combo port.
Figure 1-16 shows the front panel of an S5100-48P-EI Ethernet switch.
(1): 10/100/1000Base-T autosensing Ethernet port status LEDs (2): Console port (3): 7-segment digitron display (4): Port status LED mode switch (5): Ethernet port mode switching LED (6): Power LED (7): DC power LED (8): 1000Base-X SFP port status LED
Figure 1-16 Front panel of an S5100-48P-EI Ethernet switch
Page 20
Installation Manual H3C S5100-SI/EI Series Ethernet Switches Chapter 1 Product Overview
1-13
II. Rear panel
(1): AC power input (2): DC power input (3): Grounding terminal
Figure 1-17 Rear panel of an S5100-48P-EI Ethernet switch
III. Power supply system
An S5100-48P-EI switch provides AC power input and RPS DC input. The AC and DC power inputs can be used at the same time, acting as backup for each other. Alternatively , you can use either the AC power input alo ne or the DC power input alone. Make sure you use an RPS module recommended by H3C as the DC power input.
z AC input:
Rated voltage range: 100 VAC to 240 VAC; 50 Hz or 60 Hz Max voltage range: 90 VAC to 264 VAC; 47 Hz to 63 Hz
z DC input
Rated voltage range: -48 VDC to -60 VDC Max voltage range: -36 VDC to -72 VDC
IV. Cooling system
An S5100-48P-EI Ethernet switch provides two fans for heat dissipation.
1.3.5 S5100-26C-EI Ethernet Switch
I. Front panel
An S5100-26C-EI Ethernet switch provides 24 x 10/100/1000Base-T autosensing Ethernet ports, four 1000Base-X SFP po rts, and one console port on the front panel. An SFP port and its corresponding 10/100/1000Base-T autosensing Ethernet port form a Combo port. That is, only one of the two ports forming the Combo p ort can be used at a time.
T able 1-2 sho ws the mapping relations between the port s forming the Combo port.
Figure 1-18 shows the front panel of an S5100-26C-EI Ethernet switch.
Page 21
Installation Manual H3C S5100-SI/EI Series Ethernet Switches Chapter 1 Product Overview
1-14
(1): 10/100/1000Base-T autosensing Ethernet port status LEDs (2): 1000Base-X SFP port status LED (3): Console port (4): 7-segment digitron display (5): Power LED (6): DC power LED (7): 10 G interface slot 1 LED (8): 10G interface slot 2 LED (9): Ethernet port mode switching LED (10): Port status LED mode switch
Figure 1-18 Front panel of an S5100-26C-EI Ethernet switch
II. Rear panel
An S5100-26C-EI Ethernet switch provides AC input, DC input, and two 10 Gbps interface slots on the rear panel, as shown in
Figure 1-19.
(1): AC power input (2): DC power input (3): 10 G interface slot 1 (4): 10 G interface slot 2
(5): Grounding terminal
Figure 1-19 Rear panel of an S5100-26C-EI Ethernet switch
Note:
Both 10 G interface slot 1 and 10 G interface slot 2 can be used for XFP interface cards, stack cards, and XENPAK optical modules.
III. Power supply system
An S5100-26C-EI switch provides AC power input and RPS DC input. The AC/DC power inputs can be used at the same time, acting as backup for each other.
Page 22
Installation Manual H3C S5100-SI/EI Series Ethernet Switches Chapter 1 Product Overview
1-15
Alternatively , you can use either the AC power input alo ne or the DC power input alone. Make sure you use an RPS module recommended by H3C as the DC power input.
z AC input:
Rated voltage range: 100 VAC to 240 VAC; 50 Hz or 60 Hz Max voltage range: 90 VAC to 264 VAC; 47 Hz to 63 Hz
z DC input
Rated voltage range: -48 VDC to -60 VDC Max voltage range: -36 VDC to -72 VDC
IV. Cooling system
An S5100-26C-EI Ethernet switch provides two fans for heat dissipation.
1.3.6 S5100-50C-EI Ethernet Switch
I. Front panel
An S5100-50C-EI Ethernet switch provides 48 x 10/100/1000Base-T autosensing Ethernet ports, four 1000Base-X SFP po rts, and one console port on the front panel. An SFP port and its corresponding 10/100/1000Base-T autosensing Ethernet port form a Combo port. That is, only one of the two ports forming the Combo p ort can be used at a time.
T able 1-2 sho ws the mapping relations between the port s forming the Combo port.
Figure 1-20 shows the front panel of an S5100-50C-EI Ethernet switch.
(1)(1) (2) (3) (4) (5)
(10)
(6) (7)
(8) (9)
(1): 10/100/1000Base-T autosensing Ethernet port status LEDs (2): Console port (3): 7-segment digitron display (4): Port status LED mode switch (5): Ethernet port mode switching LED (6): Power LED (7): DC power LED (8): 10 G interface slot 1 LED (9): 10G interface slot 2 LED (10) 1000Base-X SFP port status LED
Figure 1-20 Front panel of an S5100-50C-EI Ethernet switch
Page 23
Installation Manual H3C S5100-SI/EI Series Ethernet Switches Chapter 1 Product Overview
1-16
II. Rear panel
(1): AC power input (2): DC power input (3): 10 G interface slot 1 (4): 10 G interface slot 2 (5): Grounding terminal
Figure 1-21 Rear panel of an S5100-50C-EI Ethernet switch
III. Power supply system
An S5100-50C-EI switch provides AC power input and RPS DC input. The AC/DC power inputs can be used at the same time, acting as backup for each other. Alternatively , you can use either the AC power inp ut alone or the DC power input alone. Make sure you use an RPS module recommended by H3C as the DC power input.
z AC input:
Rated voltage range: 100 VAC to 240 VAC; 50 Hz or 60 Hz Max voltage range: 90 VAC to 264 VAC; 47 Hz to 63 Hz
z DC input
Rated voltage range: -48 VDC to -60 VDC Max voltage range: -36 VDC to -72 VDC
IV. Cooling system
An S5100-50C-EI Ethernet switch provides three fans for heat dissipation.
1.3.7 S5100-8P-PWR-EI Ethernet Switch
I. Front panel
An S5100-8P-PWR-EI Ethernet switch provides 8 x 10/100/1000Base-T autosensing Ethernet ports, two 1000Base-X SFP ports, and one console port on the front panel. Figure 1-22 shows the front panel of an S5100-8P-PWR-EI Ethernet switch.
Page 24
Installation Manual H3C S5100-SI/EI Series Ethernet Switches Chapter 1 Product Overview
1-17
(1): 10/100/1000Base-T autosensing Ethernet port status LEDs (2): 1000Base-X SFP port status LED (3): Consol e port (4): 7-segment digitron display (5): Power LED (6): Ethernet port mode switching LED (7): Port status LED mode switch
Figure 1-22 Front panel of an S5100-8P-PWR-EI Ethernet switch
II. Rear panel
(1): AC power input (2): Grounding terminal
Figure 1-23 Rear panel of an S5100-8P-PWR-EI Ethernet switch
III. Side panel
An S5100-8P-PWR-EI Ethernet switch provides a lock hole for locking the switch to a secure object for theft prevention.
The lock hole is on the back of the left side panel, as sho wn in
Figure 1-3.
Note:
The lock hole cannot be used when the screw hole above it is in use.
IV. Power supply system
AC input: Rated voltage range: 100 VAC to 240 VAC; 50 Hz or 60 Hz Max voltage range: 90 VAC to 264 VAC; 47 Hz to 63 Hz
Page 25
Installation Manual H3C S5100-SI/EI Series Ethernet Switches Chapter 1 Product Overview
1-18
V. PoE
S5100-8P-PWR-EI Ethernet switches support Power Over Ethernet (PoE). They can be connected to remote powered devices (PDs), such as IP phones, WLAN APs, Security and Bluetooth APs, over twisted pair cables to remotely supply -48 VDC power to the connected PDs.
z When serving as a power sourcing equipment (PSE), an S5100-8P-PWR-EI
Ethernet switch supports IEEE802.3af standards and can also supply power to some of the PDs incompatible with 802.3af stan dards.
z An S5100-8P-PWR-EI Ethernet switch can provide power supplies through its
eight fixed Ethernet electrical ports over a distance of up to 100 m (328 feet).
z Each Ethernet port on an S5100-8P-PWR-EI Ethernet switch provides a maximum
output power of 15.4 W for the connected devices. The maximum output power for the whole system is 65 W.
VI. Cooling system
An S5100-8P-PWR-EI Ethernet switch provides two fans for heat dissipation.
1.3.8 S5100-16P-PWR-EI Ethernet Switch
I. Front panel
An S5100-16P-PWR-EI Ethernet switch provides 16 x 10/100/1000Base-T autosensing Ethernet ports, four 1000Base-X SFP ports, and one console port on the front panel. An SFP port and its corresponding 10/100/1000Base-T autosensing Ethernet port form a Combo port. That is, only one of the two ports forming the Combo port can be used at a time.
Table 1-2 shows the mapping relations between the ports
forming the Combo port.
Figure 1-24 shows the front panel of an S5100-16P-PWR-EI
Ethernet switch.
(1): 10/100/1000Base-T autosensing Ethernet port status LEDs (2): 1000Base-X SFP port status LED (3): Consol e port (4): 7-segment digitron display (5): Power LED (6): Ethernet port mode switching LED (7): Port status LED mode switch
Figure 1-24 Front panel of an S5100-16P-PWR-EI Ethernet switch
Page 26
Installation Manual H3C S5100-SI/EI Series Ethernet Switches Chapter 1 Product Overview
1-19
II. Rear panel
(1): AC power input (2): Grounding terminal
Figure 1-25 Rear panel of an S5100-16P-PWR-EI Ethernet switch
III. Side panel
An S5100-16P-PWR-EI Ethernet switch provides a lock hole for locking the switch to a secure object for theft prevention.
The lock hole is on the back of the left side panel, as sho wn in
Figure 1-3.
Note:
The lock hole cannot be used when the screw hole above it is in use.
IV. Power supply system
AC input: Rated voltage range: 100 VAC to 240 VAC; 50 Hz or 60 Hz Max voltage range: 90 VAC to 264 VAC; 47 Hz to 63 Hz
V. PoE
S5100-16P-PWR-EI Ethernet switches support PoE. They can be connected to re mote PDs, such as IP phones, WLAN APs, Security and Bluetooth APs, over twisted pair cables to remotely supply -48 VDC power to the connected PDs.
z When serving as a PSE, an S5100-16P-PWR-EI Ethernet switch supports
IEEE802.3af standards and can also supply power to some of the PDs incompatible with 802.3af standards.
z An S5100-16P-PWR-EI Ethernet switch can provide power supplies through its 1 6
fixed Ethernet electrical ports over a distance of up to 100 m (328 feet).
z Each Ethernet port on an S5100-16P-PWR-EI Ethernet switch provides a
maximum output power of 15.4 W for the connected devices. The maximum output power for the whole system is 125 W.
Page 27
Installation Manual H3C S5100-SI/EI Series Ethernet Switches Chapter 1 Product Overview
1-20
VI. Cooling system
An S5100-16P-PWR-EI Ethernet switch provides three fans for heat dissipation.
1.3.9 S5100-26C-PWR-EI Ethernet Switch
I. Front panel
An S5100-26C-PWR-EI Ethernet switch provides 24 x 10/100/1000Base-T autosensing Ethernet ports, four 1000Base-X SFP ports, and one console port on the front panel. An SFP port and its corresponding 10/100/1000Base-T autosensing Ethernet port form a Combo port. That is, only one of the two ports forming the Combo port can be used at a time.
Table 1-2 shows the mapping relations between the ports
forming the Combo port.
Figure 1-26 shows the front panel of an S5100-26C-PWR-EI
Ethernet switch.
(1): 10/100/1000 Base-T autosensing Ethernet port status LEDs (2): 1000Base-X SFP port status LED (3): Consol e port (4): 7-segment digitron display (5): Power LED (6): DC power LED (7): 10 G interface slot 1 LED (8): 10 G interface slot 2 LED (9): Ethernet port mode switching LED (10) Port status LED mode switch
Figure 1-26 Front panel of an S5100-26C-PWR-EI Ethernet switch
II. Rear panel
(1): AC power input (2): 10 G interface slot 1 (3): 10 G interface slot 2 (4): Grounding terminal (5): DC power input
Figure 1-27 Rear panel of an S5100-26C-PWR-EI Ethernet switch
Page 28
Installation Manual H3C S5100-SI/EI Series Ethernet Switches Chapter 1 Product Overview
1-21
III. Power supply system
An S5100-26C-PWR-EI switch provides AC power input and RPS DC input. The AC/DC power inputs can be used at the same time, acting as backup for each other. Alternatively , you can use either the AC power inp ut alone or the DC power input alone. Make sure you use an RPS module recommended by H3C as the DC power input.
z AC input:
Rated voltage range: 100 VAC to 240 VAC; 50 Hz or 60 Hz Max voltage range: 90 VAC to 264 VAC; 47 Hz to 63 Hz
z DC input:
Voltage range: -52 VDC to -55 VDC
IV. PoE
S5100-26C-PWR-EI Ethernet switches support PoE. They can be connected to remote PDs, such as IP phones, WLAN APs, Security and Bluetooth APs, over twisted pair cables to remotely supply -48 VDC power to the connected PDs.
z When serving as a PSE, an S5100-26C-PWR-EI Ethernet switch supports
IEEE802.3af standards and can also supply power to some of the PDs incompatible with 802.3af standards.
z An S5100-26C-PWR-EI Ethernet switch can provide power supplies through its 24
fixed Ethernet electrical ports over a distance of up to 100 m (328 feet).
z Each Ethernet port on an S5100-26C-PWR-EI Ethernet switch provides a
maximum output power of 15.4 W for the connected devices. The maximum output power for the whole system is 370 W.
V. Cooling system
An S5100-26C-PWR-EI Ethernet switch provides two fans for cooling the whole device and three fans for cooling the power supply system.
1.3.10 S5100-50C-PWR-EI Ethernet Switch
I. Front panel
An S5100-50C-PWR-EI Ethernet switch provides 48 x 10/100/1000Base-T autosensing Ethernet ports, four 1000Base-X SFP ports, and one console port on the front panel. An SFP port and its corresponding 10/100/1000Base-T autosensing Ethernet port form a Combo port. That is, only one of the two ports forming the Combo port can be used at a time.
Table 1-2 shows the mapping relations between the ports
forming the Combo port.
Figure 1-28 shows the front panel of an S5100-50C-PWR-EI
Ethernet switch.
Page 29
Installation Manual H3C S5100-SI/EI Series Ethernet Switches Chapter 1 Product Overview
1-22
(1): 10/100/1000 Base-T autosensing Ethernet port status LEDs (2): Console port (3): 7-segment digitron display (4): Port status LED mode switch (5): Ethernet port mode switching LED (6): 10 G interface slot 2 LED (7): 10 G interface slot 1 LED (8): DC power LED (9): Power LED (10): 1000Base-X SFP port status LED
Figure 1-28 Front panel of an S5100-50C-PWR-EI Ethernet switch
II. Rear panel
(1) (2) (3)
(4)(5)
(1): AC power input (2): 10 G interface slot 1 (3): 10 G interface slot 2 (4): Grounding terminal (5): DC power input
Figure 1-29 Rear panel of an S5100-50C-PWR-EI Ethernet switch
III. Power supply system
An S5100-50C-PWR-EI switch provides AC power input and RPS DC input. The AC/DC power inputs can be used at the same time, acting as backup for each other. Alternatively , you can use either the AC power inp ut alone or the DC power input alone. If DC power input is used, make sure you use an RPS module recommended by H3C as the DC power input and use an external PoE module recommended by H3C as the DC power supply . Do not di rectly use -48 V equipment-room DC power supply be cause doing so may damage the device.
z AC input:
Rated voltage range: 100 VAC to 240 VAC; 50 Hz or 60 Hz Max voltage range: 90 VAC to 264 VAC; 47 Hz to 63 Hz
z DC input:
Page 30
Installation Manual H3C S5100-SI/EI Series Ethernet Switches Chapter 1 Product Overview
1-23
Voltage range: -52 VDC to -55 VDC
IV. PoE
S5100-50C-PWR-EI Ethernet switches support PoE. They can be connected to remote PDs, such as IP phones, WLAN APs, Security and Bluetooth APs, over twisted pair cables to remotely supply -48 VDC power to the connected PDs.
z When serving as a PSE, an S5100-50C-PWR-EI Ethernet switch supports
IEEE802.3af standards and can also supply power to some of the PDs incompatible with 802.3af standards.
z An S5100-50C-PWR-EI Ethernet switch can provide power supplies through its 48
fixed Ethernet electrical ports over a distance of up to 100 m (328 feet).
z Each Ethernet port on an S5100-50C-PWR-EI Ethernet switch provides a
maximum output power of 15.4 W for the connected devices. When AC power input is used, the maximum output power for the whole system is 370 W; when DC power input is used, the maximum output power for the whole system is 740 W.
V. Cooling system
An S5100-50C-PWR-EI Ethernet switch provides three fans for cooling the whole device and three fans for cooling the power supply system.
1.4 LEDs
The S5100 series provide a power LED (PWR), a DC power LED (RPS), Gigabit autosensing Ethernet port status LEDs, a Gigabit SFP port status LED, an Ethernet port mode LED (MODE), module indicator, and a 7-segment digitron display.
1.4.1 Power LED (PWR)
The PWR LED is a green-red indicator.
Page 31
Installation Manual H3C S5100-SI/EI Series Ethernet Switches Chapter 1 Product Overview
1-24
Table 1-3 Description of the power LED
LED Mark Status Description
Yellow, ON The switch is starting. Green, ON The switch has been normally started.
Green, blinking (1 Hz)
The system is performing POST (power-on self test) or downloading software.
Red, ON
The system POST has failed or another fatal error has been detected.
Yellow, blinking (1 Hz)
One or more ports have failed in POST or other non-fatal errors have been detected.
Power LED PWR
OFF The switch has been powered off.
1.4.2 DC Power Supply LED (RPS)
The RPS LED is a yellow-green indicator.
Table 1-4 Description of the DC power supply LED
LED Mark Status Description
Green, ON Both AC and DC inputs are normal.
Yellow, ON
The AC input is abnormal; the DC input is normal.
DC power supply LED
RPS
OFF There is no DC input.
Note:
Only the S5100-24P-EI, S5100-48P-EI, S5100-26C-EI, S5100-50C-EI, S5100-26C-PWR-EI, and S5100-50C-PWR-EI switches provide DC power supply LEDs.
1.4.3 Mode LED
The mode LED is a yellow-green indicator.
Page 32
Installation Manual H3C S5100-SI/EI Series Ethernet Switches Chapter 1 Product Overview
1-25
Table 1-5 Description of the mode LED
LED Mark Status Description
OFF Invalid Green, ON The port LED is indicating rate mode. Yellow , ON The port LED is indicating duplex mode.
Mode LED Mode
Green, blinking (1 Hz)
The port LED is indicating PoE mode.
1.4.4 Gigabit Autosensing Ethernet Port Status LEDs
The Gigabit autosensing Ethernet port status LEDs are yellow-green indicator.
Table 1-6 Description of Gigabit autosensing Ethernet port status LEDs
Port mode LED status Description
ON
The port is connected at 1,000 Mbps.
Green
Blinking (30 ms per packet)
The port is receiving or sending data at 1,000 Mbps.
ON
The port is connected at 10/100 Mbps.
Blinking (30 ms per packet)
The port is receiving or sending data at 10/100 Mbps.
Yellow
Blinking (3 Hz) Port POST has failed.
Rate mode
OFF The port is not connected.
ON
The port is working in full duplex mode.
Green
Blinking (30 ms per packet)
The port is receiving or sending data in full duplex mode.
ON
The port is working in half duplex mode.
Blinking (30 ms per packet)
The port is receiving or sending data in half duplex mode.
Yellow
Blinking (3 Hz) Port POST has failed.
Duplex mode
OFF The port is not connected.
Page 33
Installation Manual H3C S5100-SI/EI Series Ethernet Switches Chapter 1 Product Overview
1-26
Port mode LED status Description
ON Power supply is normal.
Green
Blinking (3 Hz)
The power required exceeds the maximum output power of the port or the available power of the switch is insufficient.
ON
PoE malfunctioned, and the power supply failed.
Yellow
Blinking (3 Hz)
Port POST (power-on self test) failed.
PoE mode
OFF There is no power supply.
1.4.5 Gigabit SFP Port Status LED
The Gigabit SFP LED is a yellow-green indicator.
Page 34
Installation Manual H3C S5100-SI/EI Series Ethernet Switches Chapter 1 Product Overview
1-27
Table 1-7 Description of the Gigabit SFP port status LED
LED Status Description
ON
The port is connected at 1,000 Mbps.
Green
Blinking (30 ms per packet)
The port is receiving or sending data at 1,000 Mbps.
ON
The port is connected at 10/100 Mbps.
Blinking (30 ms per packet)
The port is receiving or sending data at 10/100 Mbps.
Yellow
Blinking (3 Hz)
Port POST has failed.
Rate mode
OFF The port is not connected.
ON
The port is working in full duplex mode.
Green
Blinking
The port is receiving or sending data in full duplex mode.
ON
The port is working in half duplex mode.
Blinking (30 ms per packet)
The port is receiving or sending data in half duplex mode.
Yellow
Blinking (3 Hz)
Port POST has failed.
Duplex mode
OFF The port is not connected. Yellow , blinking (3 Hz) Port POST has failed.
1000Base
-X SFP port status LED
PoE
OFF There is no power supply.
1.4.6 Module LED
The module LED is a green-yellow indicator.
Page 35
Installation Manual H3C S5100-SI/EI Series Ethernet Switches Chapter 1 Product Overview
1-28
Table 1-8 Description of the module LED
LED Mark Status Description
OFF
The module has not been installed or connected.
Green, ON
The module has been installed and connected.
Green, blinking
The module is receiving or sending data.
Yellow , blinking (3 Hz) Module POST has failed.
Module LED
MOD1 (or MOD2)
Yellow, ON
The device does not support this module.
Note:
Only the S5100-26C-EI, S5100-50C-EI, S5100-26C-PWR-EI, and S5100-50C-PWR-EI Ethernet switches provide module LEDs.
1.4.7 7-Segment Digitron Display
A green 7-segment digitro n display is employed to give indication.
Page 36
Installation Manual H3C S5100-SI/EI Series Ethernet Switches Chapter 1 Product Overview
1-29
Table 1-9 Description of the 7-segment digitron display
LED Mark
Device
status
PWR LED
status
Description
POST running
Green, blinking
The POST ID of the in-process test is displayed.
POST failed
Red, ON
The POST ID of the failed test blinks.
Loading software
Green, blinking
A light bar rotates clockwise around the display during the downloading procedure.
Fan failure
Red, ON
An “F” is displayed.
Unit ID Green, ON
A “1” is displ ayed.
Cluster Manage ment
Green, ON
A “C” is displayed on command switch.
An “S” is displayed on member switch.
A “c” is displa yed on can didate switch.
An “I” is displayed on independent switch.
Over-tem perature alarm
Red, ON
The digitron display shows a "t".
7-segm ent digitron display
Unit
PoE status (for the S5100-EI series only)
Green, ON
The ratio of the power used by the port for PoE to the total available power is displayed.
0 - 20%
21 - 40%
41 - 60%
61 - 80%
81 - 100%
Page 37
Installation Manual H3C S5100-SI/EI Series Ethernet Switches Chapter 1 Product Overview
1-30
1.5 System Features of the S5100 Series
1.5.1 System Features of the S5100-SI Series
Table 1-10 System features of the S5100-SI series
Item S5100-8P-SI S5100-16P-SI
S5100-24P-
SI
S5100-48P-SI
Dimension s
(H × W × D)
43.6 × 230 × 200 mm (1.7 × 9.1 ×
7.9 in.)
43.6 × 300 × 220 mm (1.7 × 1 1.8 × 8.7 in.)
43.6 × 440 × 260 mm (1.7 ×
17.3 × 10.2 in.)
Weight
< 1.6 kg (< 3.5 lb.)
< 2.3 kg (< 5.1 lb.)
< 4 kg (< 8.8 lb.)
4 kg (8.8 lb.)
Service ports
8 × 10/100/1000Bas e-T autosensing Ethernet ports
2 × 1000Base-X SFP ports
16 × 10/100/1000Bas e-T autosensing Ethernet ports
4 Gigabit SFP Combo ports
24 × 10/100/1000 Base-T autosensing Ethernet ports
4 Gigabit SFP Combo ports
48 × 10/100/1000 Base-T autosensing Ethernet ports
4 Gigabit SFP Combo ports
Managem ent port
One console port
Power supply system
The S5100-SI series support AC power input. Rated voltage range: 100 VAC to 240 VAC, 50 Hz or 60Hz Max voltage range: 90 VAC to 264 VAC, 47 Hz to 63 Hz
Max power consumpti on
18 W 26 W 46 W 97 W
Fan 1 1 1 2 Operating
temperatur e
0°C to 45°C (32°F to 113°F)
Relative humidity (nonconde nsing)
10% to 90%
Page 38
Installation Manual H3C S5100-SI/EI Series Ethernet Switches Chapter 1 Product Overview
1-31
1.5.2 System Features of the S5100-EI Series
Table 1-11 System features of the S5100-EI series (1)
Item S5100-8P-EI S5100-16P-EI
S5100-24P-EI S5100-48P-E
I
Dimensions (H × W × D)
43.6 × 230 × 200 mm (1.7 ×
9.1 × 7.9 in.)
43.6 × 300 × 220 mm (1.7 × 1 1.8 × 8.7 in.)
43.6 × 440 × 260 mm (1.7 ×
17.3 × 10.2 in.)
Weight
< 1.6 kg (< 3.5 lb.)
< 2.3 kg (< 5.1 lb.)
< 4 kg (< 8.8 lb.)
4 kg (8.8 lb.)
Service ports
8 × 10/100/1000B ase-T autosensing Ethernet ports
2 × 1000Base-X SFP ports
16 × 10/100/1000Ba se-T autosensing Ethernet ports
4 Gigabit SFP Combo ports
24 × 10/100/1000 Base-T autosensing Ethernet ports
4 Gigabit SFP Combo ports
48 × 10/100/1000 Base-T autosensing Ethernet ports
4 Gigabit SFP Combo ports
Managemen t port
One console port
Power supply system
The S5100-EI series support AC input and DC input. AC input: Rated voltage range: 100 VAC to 240 VAC, 50 Hz or 60Hz Max voltage range: 90 VAC to 264 VAC, 47 Hz to 63 Hz DC input (for the S5100-24P-EI and S5100-48P-EI): Rated voltage range: -48 VDC to -60 VDC Max voltage range:-36 VDC to -72 VDC
Max power consumption
18 W 26 W 46 W 97 W
Fan 1 1 1 2 Operating
temperature
0°C to 45°C (32°F to 113°F)
Relative humidity (noncondens ing)
10% to 90%
Table 1-12 System features of the S5100-EI series (2)
Item S5100-26C-EI S5100-50C-EI
Dimensions (H × W × D)
43.6 × 440 × 300 mm (1.7 × 17.3 × 11.8 in.)
Weight 4 kg (8.8 lb.) < 5 kg (< 11 lb.)
Page 39
Installation Manual H3C S5100-SI/EI Series Ethernet Switches Chapter 1 Product Overview
1-32
Item S5100-26C-EI S5100-50C-EI
Service ports
24 × 10/100/1000MBase-T autosensing Ethernet ports
4 Gigabit SFP Combo ports
48 × 10/100/1000MBase-T autosensing Ethernet ports
4 Gigabit SFP Combo ports
Extension slots
Two 10 G slots Two 10 G slots
Managemen t port
One console port
Power supply system
The S5100-EI series support AC input and DC input. AC input: Rated voltage range: 100 VAC to 240 VAC, 50 Hz or 60Hz Max voltage range: 90 VAC to 264 VAC, 47 Hz to 63 Hz DC input: Rated voltage range: -48 VDC to -60 VDC Max voltage range: -36 VDC to -72 VDC
Max power consumption
68 W 1 16 W
Fan 2 3 Operating
temperature
0°C to 45°C (32°F to 113°F)
Relative humidity (noncondens ing)
10% to 90%
Table 1-13 System features of the S5100-EI series (3)
Item
S5100-8P-P
WR-EI
S5100-16P-
PWR-EI
S5100-26C-PW
R-EI
S5100-50C-PW
R-EI
Dimensions (H × W × D)
43.6 × 300 × 220 mm (1.7 × 11.8 × 8.7 in.)
43.6 × 300 × 260 mm (1.7 × 1 1.8 × 10.2 in.)
43.6 × 440 × 420 mm (1.7 × 17.3 ×
16.5 in.)
Weight
2.5 kg (5.5 lb.)
< 3.1 kg (<
6.8 lb.)
< 6.9 kg (15.2 lb.)
< 7.4 kg (16.3 lb.)
Managemen t port
One console port
Page 40
Installation Manual H3C S5100-SI/EI Series Ethernet Switches Chapter 1 Product Overview
1-33
Item
S5100-8P-P
WR-EI
S5100-16P-
PWR-EI
S5100-26C-PW
R-EI
S5100-50C-PW
R-EI
Service ports
8 × 10/100/1000 Base-T autosensing Ethernet ports
2 × 1000Base-X SFP ports
16 × 10/100/1000 Base-T autosensing Ethernet ports
4 Gigabit SFP Combo ports
24 × 10/100/1000Bas e-T autosensing Ethernet ports
4 Gigabit SFP Combo ports
48 × 10/100/1000 Base-T autosensing Ethernet ports
4 Gigabit SFP Combo ports
Extension slots
Two 10 G slots Two 10 G slots
Input voltage
The S5100-EI series support AC input and DC input. AC input: Rated voltage range: 100 VAC to 240 VAC, 50 Hz or 60Hz Max voltage range: 90 VAC to 264 VAC, 47 Hz to 63 Hz DC input (for S5100-26C-PWR-EI and S5100-50C-PWR-EI): Voltage range: -52 VDC to -55 VDC
Max pow er cons umpt ion
100 W 170 W
AC input: 500 W DC input:435 W
AC input: 540 W DC input: 840 W
Whe n all the ports provi de PoE exter nally
Max pow er supp lied exter nally (PoE )
15.4 W × 4 15.4 W × 8 15.4 W × 24
AC input: 15.4 W × 24
DC input: 15.4 W × 48
Fan 2 3
Two fans for cooling the whole device
Three fans for cooling the power supply system
Three fans for cooling the whole device
Three fans for cooling the power supply system
Operating temperature
0°C to 45°C (32°F to 113°F)
Relative humidity (noncondens ing)
10% to 90%
Page 41
Installation Manual H3C S5100-SI/EI Series Ethernet Switches Chapter 1 Product Overview
1-34
The S5100-8P-PWR-EI, S5100-16P-PWR-EI, S5100-26C-PWR-EI, and S5100-50C-PWR-EI Ethernet switches provide over-temperature protection. With this mechanism, the switch disables the PoE feature on all its ports for self-prote ction when its internal temperature exceeds the PoE protection temperature, and restores the PoE feature on all its ports when its internal temperature drops below the PoE restoration temperature.
Table 1-14 lists the PoE protection temperatures and restoration
temperatures
Table 1-14 PoE protection temperatures and restoration temperatures
Item
PoE protection
temperature (°C)
PoE restoration
temperature (°C)
S5100-8P-PWR-EI 73 68 S5100-16P-PWR-EI 61 56 S5100-26C-PWR-EI 61 56 S5100-50C-PWR-EI 61 56
1.6 Ordering SFP/XFP/XENPAK Interface Modules
Table 1-15 Ordering information for the interface modules
Item Model
SFP-FE-SX-MM1310-A SFP-FE-LX-SM1310-A SFP-FE-LH40-SM1310
100 M SFP modules
SFP-FE-LH80-SM1550 SFP-GE-SX-MM850-A SFP-GE-LX-SM1310-A SFP-GE-LH40-SM1310 SFP-GE-LH40-SM1550
Gigabit SFP modules
SFP-GE-LH70-SM1550
SFP electrical ports SFP-GE-T
SFP-GE-LX-SM1310-BIDI
Gigabit BIDI modules
SFP-GE-LX-SM1490-BIDI SFP-FE-LX-SM1310-BIDI
SFP optical modules
100 M BIDI modules
SFP-FE-LX-SM1550-BIDI
Page 42
Installation Manual H3C S5100-SI/EI Series Ethernet Switches Chapter 1 Product Overview
1-35
Item Model
XFP-SX-MM850 XFP-LX-SM1310
XFP modules
XFP-LH40-SM1550-F1 XENPAK-SX-MM850 XENPAK-LX-SM1310
XENPAK optical modules
XENPAK-LH40-SM1550
Note:
z You are recommended to use H3C's optical modules for the S5100-SI/EI series
Ethernet switches.
z Only the S5100-26C-EI, S5100-50C-EI, S5100-26C-PWR-EI, and
S5100-50C-PWR-EI switches support XFP optical modules, but these switches do not support the XFP modules that require -5.2 V power supply.
z Only the S5100-26C-EI, S5100-50C-EI, S5100-26C-PWR-EI, and
S5100-50C-PWR-EI switches support XENPAK optical modules.
z BIDI modules must be used in pair. For example, if an SFP-GE-LX-SM1310-BIDI is
used at one end, an SFP-GE-LX-SM1490-BIDI module must be used at the other end. 100 M BIDI modules must also be used in pair.
z For detailed SFP module specifications, see H3C Low-End Series Ethernet
Switches Pluggable Module Manual
.
1.7 Ordering 10 G Stack Interface Modules
Table 1-16 Ordering information for 10 G stack interface modules
Model No. Description
LS5M1XS1PA Single-port 10 G Ethernet stack interface board (STACK)
Note:
Only the S5100-26C-EI, S5100-50C-EI, S5100-26C-PWR-EI, and S5100-50C-PWR-EI switches support 10 G stack modules.
Page 43
Installation Manual H3C S5100-SI/EI Series Ethernet Switches Chapter 1 Product Overview
1-36
1.8 Ordering Stack Cables
Table 1-17 Ordering information for stack cables
Model No. Length Description
LS5M2STK1 50 cm (19.7 in.) CX4 stack cable (50 cm) LS5M2STK2 100 cm (39.4 in.) CX4 stack cable (1.0 m) LS5M2STK3 300 cm (118.1 in.) CX4 stack cable (3.0 m)
1.9 Ordering DC Power cords
Table 1-18 Ordering information for DC power cords
Model No. Length Description
CAB-48V Pwr-2m-T2.5^2 2 m (6.6 ft.) Power cord 14AWG 2 m CAB-RPS Non PoE-2m-JD5 2 m (6.6 ft.) JD5 DC power cord CAB-RPS Non PoE-2m-JD5-A 2 m (6.6 ft.) JD5-A DC power cord
Page 44
Installation Manual H3C S5100-SI/EI Series Ethernet Switches Chapter 2 Preparing for Installation
2-1
Chapter 2 Preparing for Installation
2.1 Safety Precautions
T o avoid any device imp airment or bodily injury caused by improper use, observe these rules:
z Before cleaning the switch, unplug the power plug from the switch first. Do not
clean the switch with wet cloth or liquid.
z Do not place the switch near water or any damp area. Prevent water or moisture
from entering the switch chassis.
z Do not place the switch on an unstable case or desk. The switch might be
damaged severely in case of a fall.
z Ensure proper ventilation of the equipment room and keep the ventilation vents of
the switch free of obstruction.
z Make sure that the operating voltage is the same as that labeled on the switch. z Do not open the chassis while the switch is operating or when electrical hazards
are present to avoid electrical shocks.
z When replacing interface cards, wear ESD-preventive gloves to avoid damaging
the cards.
2.2 Installation Site
The S5100 series must be used indoors. You can mount your switch in a rack or on a tabletop/workbench, but make sure:
z Adequate clearance is reserved at the air inlet/exhaust vents for ventilation. z The rack or table/workbench has a good ventilation system. z The rack is sturdy enough to support the device and its accessories. z The rack or table/workbench is well earthed.
To ensure normal operation and long service life of an S5100 switch, install it in an environment that meets the requirements descri bed in the following subsections.
2.2.1 Temperature/Humidity
You need to maintain a proper temperature and humidity in the equipment room.
z Long-term high humidity may lead to bad insulation, electricity leakage,
mechanical property changes, and corrosion.
z If the relative humidity is two low, captive screws may become loose as the result
of contraction of insulation washers and static elect ricity may be produced in a dry environment to jeopardize the circuits on the device.
Page 45
Installation Manual H3C S5100-SI/EI Series Ethernet Switches Chapter 2 Preparing for Installation
2-2
z High temperature is the most undesirable condition, because it accelerates aging
of insulation materials and can thus significantly lower reliability and service life of your switch.
For the detailed temperature/humidity requirements for the products, see section
1.5
System Features of the S5100 Series.
2.2.2 Cleanness
Dust is a hazard to the operating safety of your device. The dust accumulated on the chassis can be adsorbed by static electricity and result in poor contact of metal connectors or metal contact points. When the relative indoor humidity is low , espe cially , electrostatic adsorption is more likely to happen. This can not only shorten the service life of your device but also cause communications failures. The following table lists the dust concentration limit.
Table 2-1 Dust concentration limit in the equipment room
Substance Unit Concentration limit
Dust Particles/m³
3 × 10
4
(No visible dust on the
tabletop for three days)
Note: The dust particle size is greater than or equal to 5 μm
Besides dust, there are rigorous limits on the content of harmful substances that can accelerate the corrosion and aging of metals, such as salts, acids, and sulfides in the air in the equipment room, and the equipment room must be protected against ingression of harmful gases such as SO
2
, H2S, NH3, and Cl2. For the specific
requirement, see the following table.
Table 2-2 Harmful gas limits in the equipment room
Gas Maximum concentration (mg/m3)
SO2 0.2 H2S 0.006 NH3 0.05 Cl2 0.01
2.2.3 Electromagnetic Susceptibility
The operation of your switch can be affected by external interferences, such as conducted emission by capacitance coupling, inductance coupling, electromagnetic wave radiation, and common impedance (including the grounding system) coupling,
Page 46
Installation Manual H3C S5100-SI/EI Series Ethernet Switches Chapter 2 Preparing for Installation
2-3
and leads (power cords, signaling cables and output wires). To eliminate the interferences, ensure the following:
z For the AC power supply that adopts TN system, use a single-phase three-wire
power socket with Protection Earth (PE) to effectively filter interference from the power grid.
z Keep the device far from radio transmitting stations, radar stations, and
high-frequency devices.
z Use electromagnetic shielding when necessary, for example, use shielded
interface cables.
z Route interface cables only indoors to prevent signal ports from getting damaged
by overvoltage or overcurrent caused by lightning strikes.
2.2.4 Safety in Use of Laser
The S5100 series are class-1 laser devices. When the extended optical interface cards on your switch are operating, do not stare
into the optical ports because the laser light emitted by the optical fiber can hurt your retina.
Caution:
Staring into the laser beam produced by the fiber can hurt your eyes.
2.3 Installation Tools
z Flathead screwdrivers z Phillips screwdrivers z ESD-preventive wrist strap
Caution:
The installation tools are not provided with the S5100 series.
Page 47
Installation Manual H3C S5100-SI/EI Series Ethernet Switches Chapter 3 Installing the Switch
3-1
Chapter 3 Installing the Switch
Caution:
When you ask your sales agent to maintain the switch, you must ensure that the dismantlement-preventive seal on a mounting screw of the switch chassis is intact. If you want to open the chassis, you should contact the agent for permission. Otherwise, you will bear any consequence resulted from your actions without permission.
3.1 Rack-Mounting the Switch
You can mount an H3C S5100 switch into a 19-inch standard rack in one of the following four ways:
z Use front mounting ears z Use front mounting ears and rear mounting ears z Use front mounting ears and a tray z Use front mounting ears and guide rails
The installation methods of a switch depend on the depth and width of the switch. For the specific installation methods, see
Table 3-1 and Table 3-2.
Table 3-1 Installation methods for a switch with a width of 440 mm or 436 mm (17.3 in.
or 17.2 in)
Method
Depth
Use front
mounting
ears
Use front and
rear mounting
ears
Use front
mounting
ears and a
tray
Use front mounting
ears and
guide rails
300 mm (11.8 in.)
360 mm (14.2 in.)
420 mm (16.5 in.)
Page 48
Installation Manual H3C S5100-SI/EI Series Ethernet Switches Chapter 3 Installing the Switch
3-2
Table 3-2 Installation method for a switch with a width less than 436 mm (17.2 in.)
Method
Depth
Use front
mounting
ears
Use front and
rear mounting
ears
Use front
mountings
ear and a
tray
Use front
mounting
ears and
guide rails
300 mm (11.8 in.)
360 mm (14.2 in.)
— —
420 mm (16.5 in.)
— —
Note:
z When the depth of a switch is greater than 300 mm (11.8 in.), the front mounting
ears only secure the switch rather than bear its weight.
z Guide rails purchased from H3C apply only to standard racks 1,000 mm (39.4 in.)
deep. Use other supports to substitute for guide rails in the case of other rack depths.
3.1.1 Introduction to Mounting Ear
Figure 3-1 shows the appearance of a front mounting ear.
(1) Screw hole used to fix the mounting ear to the cabinet (Use one M6 screw) (2) Screw hole used to fix the switch to the mounting ear
Figure 3-1 Appearance of a front mounting ear
Figure 3-2 shows the appearance of a rear mounting ear.
Page 49
Installation Manual H3C S5100-SI/EI Series Ethernet Switches Chapter 3 Installing the Switch
3-3
(1) Screw hole used to fix the mounting ear to the rack (Use one M6 screw)
Figure 3-2 Appearance of a rear mounting ear
When you install an H3C S5100 series switch into a 19-inch st andard ra ck, you should select front mounting ears with a proper length (L1 as shown in
Figure 3-1) according to the physical dimensions of the switch. For the selection of front and rear mounting ears, see
Table 3-3.
Table 3-3 Selection of mounting ear for the H3C S5100 series Ethernet Switches
Model
Physical dimensions
(H x W x D)
Configuration
type of front
mounting ear
Configuration
type of rear
mounting ear
S5100-8P-SI S5100-8P-EI
43.6 × 230 × 200 mm (1.7 x 9.1 x 7.9 in.)
Optional
S5100-16P-SI S5100-16P-EI S5100-8P-PWR-EI
43.6 × 300 × 220 mm (1.7 × 11.8 × 8.7 in.)
Optional
S5100-24P-SI S5100-24P-EI S5100-48P-SI S5100-48P-EI
43.6 × 440 × 260 mm (1.7 × 17.3 × 10.2 in.)
Standard —
S5100-26C-EI S5100-50C-EI
43.6 × 440 × 300 mm (1.7 × 17.3 × 11.8 in.)
Standard —
S5100-16P-PWR-EI 43.6 × 300 × 260 mm
(1.7 × 11.8 × 10.2 in.)
Optional
S5100-26C-PWR-E I
S5100-50C-PWR-E I
43.6 × 440 × 420 ×mm (1.7 × 17.3 × 16.5 in.)
Standard Standard
Page 50
Installation Manual H3C S5100-SI/EI Series Ethernet Switches Chapter 3 Installing the Switch
3-4
3.1.2 Introduction to Guide Rail
Figure 3-3 shows the appearance of a guide rail.
Slotted hole 1: Used to fix the guide rail to the rear bracket. You can adjust the screw hole position according to the position of the switch. Cooling hole: Used for heat dissipation between switch and rack Slotted hole 2: Used to fix the guide rail to the front bracket
Figure 3-3 Appearance of a guide rail
Note:
No guide rails are delivered with the device. See Table 3-1 and Table 3-2 to decide whether any guide rails are needed.
3.1.3 Using Front Mounting Ears to Install a Switch
Follow these steps to mount a switch into a 19-inch standard rack with front mounting ears:
1) Wear an ESD-preventive wrist strap to check the grounding and stability of the
rack.
2) Take out the screws which are packed together with the front mounting ears, and
fix one end of mounting ears to the switch, as shown in
Figure 3-4.
Page 51
Installation Manual H3C S5100-SI/EI Series Ethernet Switches Chapter 3 Installing the Switch
3-5
Figure 3-4 Fix front mounting ears
3) Place the switch horizontally in a proper position, and fix the other end of mounting
ears to the front brackets with screws and captive nuts, as shown in
Figure 3-5.
Figure 3-5 Mounting the switch with front mounting ears and a tray
3.1.4 Use Front Mounting Ears and a Tray
Follow these steps to install a switch into a 19-inch standard rack with front mounting ears and a tray:
1) Wear an ESD-preventive wrist strap to check the grounding and stability of the
rack.
2) Fix the delivered tray horizontally in a proper position.
3) Take out the screws which are packed together with the front mounting ears, and
fix one end of mounting ears to the switch, as shown in
Figure 3-4.
4) Place the switch on the tray horizontally, slide the tray into the cabinet, and fix the
other end of mounting ears to the front brackets with crews and captive nuts, as shown in
Figure 3-5.
Page 52
Installation Manual H3C S5100-SI/EI Series Ethernet Switches Chapter 3 Installing the Switch
3-6
3.1.5 Use Front and Rear Mounting Ears
Follow these steps to install a switch into a 19-inch standard rack with front and rear mounting ears:
1) Wear an ESD-preventive wrist strap to check the grounding and stability of the
rack.
2) Take out the screws which are packed together with the front mounting ears, and
fix one end of mounting ears to the switch, as shown in
Figure 3-4.
3) Take out the load-bearing screws (packed together with the rear mounting ears)
and place them in a proper position on the sides of the switch, a s shown in
Figure
3-6.
Screw 1: Load-bearing screw
Figure 3-6 Fix front mounting ears and load-bearing screws
Note:
There are three positions to mount a load-bearing screw on both sides of a switch. You should select a proper position according to the actual requirements. The rear mounting ears tightly contacted with the load-bearing screws can support the switch.
4) Select a position to install the switch and fix the rear mounting ears to the rear
brackets with screws and captive nuts, as shown in
Figure 3-7.
Page 53
Installation Manual H3C S5100-SI/EI Series Ethernet Switches Chapter 3 Installing the Switch
3-7
Figure 3-7 Fix rear mounting ears
5) Hold the bottom of the switch with one hand and the front part of the switch with
the other hand, and pull the switch into the cabinet gently, as shown in
Figure 3-8.
Screw 1
Screw 2
Rear mounting ear
Front mounting ear
Front square-holed bracket
Rear panel
Rear square-holed bracket
Screw 1: Used to bear the weight Screw 2: Used to fix rear mounting ears to rear brackets
Figure 3-8 Fix front and rear mounting ears
After the switch is pushed into the cabinet, ensure that the upper edge of rear mounting ears is tightly contacted with the load-bearing screw, as shown in
Figure 3-9.
Page 54
Installation Manual H3C S5100-SI/EI Series Ethernet Switches Chapter 3 Installing the Switch
3-8
Screw 1: Load-bearing screw
Figure 3-9 Effect diagram of front and rear mounting ear installation (1)
6) Fix the other end of the front mounting ears to the front brackets with screws and
captive nuts and ensure that front and rear mounting ears have fixed the switch in the cabinet securely, as shown in
Figure 3-10.
Page 55
Installation Manual H3C S5100-SI/EI Series Ethernet Switches Chapter 3 Installing the Switch
3-9
Screw 1: Load-bearing screw
Figure 3-10 Effect diagram of front and rear mounting ear installation (2)
3.1.6 Use Front Mounting Ears and Guide Rails
Follow these steps to install a switch into a 19-inch standard rack with front mounting ears and guide rails:
1) Wear an ESD-preventive wrist strap to check the grounding and stability of the
rack.
2) Take out the screws packed together with the front mounting ears and fix one end
of the front mounting ears to the switch, as shown in
Figure 3-11.
Page 56
Installation Manual H3C S5100-SI/EI Series Ethernet Switches Chapter 3 Installing the Switch
3-10
Figure 3-11 Fix front mounting ears
3) Install guide rails on the brackets on both sides of the cabinet with M5 self-tapping
screws, as shown in
Figure 3-12.
Figure 3-12 Install guide rails
4) Hold the two sides of the switch and slide it gently along the guide rails into the
cabinet until it is located in a proper position, as shown in
Figure 3-13. Ensure that
the bottom side of the guide rails and the switch are in close contact.
Page 57
Installation Manual H3C S5100-SI/EI Series Ethernet Switches Chapter 3 Installing the Switch
3-11
Figure 3-13 Install front mounting ears and guide rails
5) Fix the other end of front mounting ears to the front brackets of the cabinet with M6
screws and captive nuts and ensure that the front mounting ears and guide rails have fixed the switch in the cabinet securely, as shown in
Figure 3-14.
Figure 3-14 Effect diagram of front mounting ear and guide rail installation
Note:
Ensure a clearance of 1U (44.45 mm, namely, 1.75 inches) between devices for the purpose of heat dissipation.
Page 58
Installation Manual H3C S5100-SI/EI Series Ethernet Switches Chapter 3 Installing the Switch
3-12
3.2 Desk Mounting
When no 19-inch standard rack is available, you can simply place the switch on a clean desk. When doing so, you should ensure that:
z The desk is stable and well grounded. z The installation environment is drafty and a clearance about 10 cm (3.9 in) is
reserved around the switch for heat dissipation.
z No heavy object is placed on the switch. z A vertical dist ance of at least 1.5 cm (0.6 in) is kept between devi ces if you need to
stack switches one upon another.
3.3 Wall Mounting
You can mount the S5100-8P-EI, S5100-16P-EI, S5100-8P-PWR-EI, and S5100-16P-PWR-EI series Ethernet switches on concrete walls or wood walls.
I. Introduction to screw and anchor kit
Figure 3-15 and Figure 3-16 show the recommended sizes (in mm) of screws and anchor kits used for mounting:
Figure 3-15 Screw
(1)(1)
(1) Outside edge of anchor kit
Figure 3-16 Anchor kit
II. Installation procedure
The wall-mounting procedure is as follows:
Page 59
Installation Manual H3C S5100-SI/EI Series Ethernet Switches Chapter 3 Installing the Switch
3-13
1) As shown in Figure 3-17, drill two holes having a diameter of 5 mm (0.2 in.) in the
wall on the same horizontal line, with a distance of 170 mm (6.7 in).
Note:
Drill two holes according to the sizes of anchor kits and screws so that anchor kits could go into the holes, only the edges could remain outside the wall, and the screws could be fixed on the wall tightly.
2) Insert anchor kits into the holes and keep only the edges outside the wall.
3) As shown in
Figure 3-17, drive screws into the anchor kits, keeping the inside of screw head at least 1.5 mm (0.06 in.) away from the edge of the anchor kit so that the switch could hang on the screws securely.
1.5 mm(Min)
X mm
Figure 3-17 Wall mounting
4) Align the two installation holes at the bottom of the switch with these two screws to hang the switch.
Caution:
When mounting the switch, keep the Ethernet ports of the switch facing downwards and the two sides with ventilation holes vertical to the ground.
3.4 Magnet Mounting
The S5100-8P-EI, S5100-16P-EI, S5100-8P-PWR-EI, and S5100-16P-PWR-EI series Ethernet switches support magnet mounting:
Page 60
Installation Manual H3C S5100-SI/EI Series Ethernet Switches Chapter 3 Installing the Switch
3-14
I. Introduction to magnetic accessories
A set of magnetic mounting accessories consists of one permanent magnets and one M3*6 countersunk head screws, as shown in
Figure 3-18. Four sets of magnetic
mounting accessories are needed for each S5100 switch.
(1)
(2)
(1) Permanent magnet (2) M3*6 countersunk head screw
Figure 3-18 Magnets and countersunk head screws
II. Installation procedure
Follow these steps to complete magnet mounting:
1) As shown in
Figure 3-19, use a Phillips screwdriver to pass the countersunk head screw through the round hole at the central of the permanent magnet, fasten it to a blind nut in the dent of the switch bottom, and ensure that the permanent magnet and the switch are fastened reliably.
Note:
z Remove the cushion, if any, from the dent before installation. z To ensure the firmness of installation, be sure to use four permanent magnets to
secure each S5100 switch.
2) Attach the magnet-mounted device to the specified location. Take care not to get your fingers stuck between because the magnetism is very huge.
Page 61
Installation Manual H3C S5100-SI/EI Series Ethernet Switches Chapter 3 Installing the Switch
3-15
(1)
(2)(3)
(1) Blind nut in the dent of the switch bottom (2) Permanent magnet (3) M3*6 countersunk head screw
Figure 3-19 Magnet mounting
Caution:
z Apply magnet mounting to only the above four models. Otherwise, a falloff or
mis-operation may occur.
z Select the installation location carefully. In the case of poor interface, magnet
mounting may not be reliable.
z Put the device at a stable place free from vibrations or shocks. Otherwise, personal
injuries or equipment damage may occur.
z Avoid installing the device at a high place because personal injuries or equipment
damage may occur in case of a falloff.
z Avoid frequently moving the desk-mounted device because such movements may
damage the surface coating.
z Keep the front panel of the device facing downwards and the two sides with
ventilation holes vertical to the ground, if you want to install the device vertically.
z Pay attention that the weight of external cables should not bring about a falloff,
which may result in personal injuries or equipment damage.
z Keep floppy disks and magnetic cards away from magnets to avoid erasure of any
information.
z Keep computers and monitors that are easily influenced by magnetic fields away
from magnets. Otherwise, faults may occur to these electronic devices.
Page 62
Installation Manual H3C S5100-SI/EI Series Ethernet Switches Chapter 3 Installing the Switch
3-16
3.5 Connecting Power Cord and Grounding Wire
3.5.1 Connecting AC Power Cord
I. AC power socket (recommended)
You are recommended to use a mono-phase three-wire power socket with a neutral point or a multi-function power socket for computers. The neutral point of the power in your building must be well grounded. Normally, the neutral point of the power supply system in your building has already been grounded during the construction an d wiring; but you should make sure this is the fact.
Neutral point
Zero line
Live line
Neutral point
Zero line
Live line
Figure 3-20 Recommended AC power socket
II. Connecting AC power cord
1) Connect one end of the grounding wire (delivered with the switch) to the grounding screw on the rear of the chassis and the other end to the ground nearby.
2) Connect one end of the power cord to the power socket on the rear panel of the chassis and the other end to an outside AC power socket.
3) Install the power cord tie for the AC power cord. Insert the two ends of the power cord tie into the slots at both sides of the AC power input, and then set the power cord into the notch of the power cord tie.
(4)
(2)
(3)
(1)
(4)
(2)
(3)
(1)
(1): Rear panel (2): Slot of power cord tie (3): AC power cord tie (4): AC power cord
Figure 3-21 Install AC power cord ties
Page 63
Installation Manual H3C S5100-SI/EI Series Ethernet Switches Chapter 3 Installing the Switch
3-17
Note:
The AC power cord tie can prevent the AC power cord from accidentally falling off.
4) Check whether the PWR LED on the front panel of the switch is ON. If yes, the power is properly connected.
Caution:
Before powering on the switch, you should properly connect the grounding wi re.
3.5.2 Connecting DC Power Cord
+-NULL+-NULL
+: -48 V working ground —: -48 V to -60 V NULL: Reserved
Figure 3-22 DC power socket for the switch
1) Connect one end of the grounding wire (delivered with the switch) to the grounding screw and the other end to the ground nearby.
2) Assemble the DC power connector as follows:
Figure 3-23 RPS DC power connector
Page 64
Installation Manual H3C S5100-SI/EI Series Ethernet Switches Chapter 3 Installing the Switch
3-18
3) As shown in Figure 3-23, pass the two power cords through the air filter, insert them into the corresponding holes, and tighten them with screw 1 and screw 2. The positive and negative poles of the power cords must correspond to the silkscreen above the holes.
4) Use a flathead screwdriver to fix the air filter on the connector with screw 3 and screw 4, as shown in
Figure 3-23.
5) Use cable ties to bind the two power cords to the protruding part at the back of the air filter, as shown in
Figure 3-23.
Conn ec t or par ts
Screw 1
Screw 2
Chassis
Conn ec t or par ts
Screw 1
Screw 2
Chassis
Figure 3-24 Fix the RPS DC power connector to t he chassis
6) Insert the connector into the DC socket directly. Use the flathead screwdriver to fix the connector with screw 1 and screw 2 (delivered with the switch), as shown in Figure 3-24.
7) Check whether the PWR LED on the front panel of the switch is ON. If yes, the power is properly connected.
Caution:
z Before powering on the switch, you should properly connect the grounding wi re. z The DC power cord should be less than 3 meters (9.8 ft.) long.
Page 65
Installation Manual H3C S5100-SI/EI Series Ethernet Switches Chapter 3 Installing the Switch
3-19
3.5.3 Connecting Grounding Wire
Caution:
You should properly connect the switch grounding wire sin ce it is crucial to the lightning protection and electromagnetic shield (EMS) of your switch.
The power input end of the switch is connected with a noise filter , whose central ground is directly connected to the chassis, forming the so-called chassis ground (commonly known as PGND). This chassis ground must be securely connected to the earth so that the faradism and leakage electricity can be safely released to the earth, enhancing the EMS capability of the switch.
Ground the switch as follows: When a grounding strip is available at the installation site, attach one end of the
yellow-green grounding wire of the switch to the grounding screw on the grounding strip and fasten the captive nut. (Note that the fire main and lightning rod of your building are not suitable for grounding the switch. The grounding wire of the switch should be connected to the construction engineering ground of the equipment room.)
(1) Power input (2) Grounding screw (3) Protection grounding wire (4) Grounding strip
Figure 3-25 Ground the switch through a grounding strip
When there is no grounding strip but there is cement floor nearby where a grounding body is allowed to be buried, hammer an angle steel/steel pipe no shorter than 0.5 m (1.6 ft.) into the earth, with the yellow-green grounding wire of the switch welded onto the angle steel/steel pipe and the jointing point being processed against erosion.
Page 66
Installation Manual H3C S5100-SI/EI Series Ethernet Switches Chapter 3 Installing the Switch
3-20
(1) Power input (2) Grounding screw (3) Protection grounding wire (4) Earth (5) Angle steel
Figure 3-26 Ground the switch by burying the grounding body into the earth
For an AC-powered switch, if none of the above two conditions is available, ground it through the PE wire of the AC power supply . In this case, make sure this PE wire is well connected to the ground at the power distribution room or AC transformer.
(1) AC power socket (2) Grounding screw (3) Power transformer (4) PE wire (5) 3-wire cable for AC power input (6) Ethernet switch
Figure 3-27 Ground the switch through AC PE wire
Page 67
Installation Manual H3C S5100-SI/EI Series Ethernet Switches Chapter 3 Installing the Switch
3-21
For a DC-powered switch (–48 VDC), if none of the first two conditions is available, ground it through the return wire (RTN) of the DC power supply. In this case, make sure this RTN wire is well connected to the ground at the DC output of the DC power cabinet.
(9)(10)
(11)
(3)
(5)
(2)
(4)
(6)
(7)
(8)
(1)
(1) AC/DC power cabinet (2) –48V strip (3) –48V (4) RTN strip (5) RTN (6) PGND strip (7) Grounding to the earth (8) Grounding wire (9) Screw (10) Ethernet switch (11) DC power input
Figure 3-28 Ground the switch through the PGND of the power cabinet
3.6 Connecting Console Cable
3.6.1 Console Cable
Console cable is an 8-core shielded cable. At one end of the cable is a crimped RJ45 connector to be connected to the Console port of the switch; at the other end of the cable is a DB-9 (female) connector to be conne cted to the 9-core (pin) serial port on the Console terminal. See
Figure 3-29.
Main label
1
8
B side
B
Pos.9
Pos.1
A side
A
Figure 3-29 Console cable
Page 68
Installation Manual H3C S5100-SI/EI Series Ethernet Switches Chapter 3 Installing the Switch
3-22
Table 3-4 Console cable connector pinouts and mapping relation
RJ-45 Signal Direction DB-9
1 RTS ← 7 2 DTR ← 4 3 TXD ← 3 4 CD → 1 5 GND — 5 6 RXD → 2 7 DSR → 6 8 CTS → 8
3.6.2 Connecting Console Cable
Follow these steps to connect a terminal device, a PC for example, to the switch: Step 1: Connect the DB-9 female connector of the Console cable to the serial port of
the PC or the terminal device used to configure the switch. Step 2: Connect the RJ-45 connector of the Console cable to the Console port of the
switch.
Caution:
Identify the label of the port before connecting a connector.
Note:
If the switch has been powered on,
z First connect the DB-9 connector of the console cable to the PC before connecting
the RJ45 connector to the switch.
z Disconnect the DB-9 connector of the console cable from the PC after
disconnecting the RJ45 connector from the switch.
Page 69
Installation Manual H3C S5100-SI/EI Series Ethernet Switches Chapter 3 Installing the Switch
3-23
3.7 Installing and Removing Optional Interface Modules
3.7.1 XFP Interface Module
I. Appearance and front panel
Figure 3-30 Appearance of an XFP interface module
Figure 3-31 Front panel of an XFP interface module
II. Installation
Step 1: Put on an ESD-preventive wrist strap and verify the ESD-preventive wrist strap properly grounded. Then take out the XFP interface module from the package.
Step 2: Loosen the mounting screws of the filler panel on the rear panel of the switch with a screwdriver and remove the filler panel.
Step 3: Hold the fastening screws on the front panel of the XFP interface module, and gently push the XFP interface module in along the slot guide rail until the XFP interface module is in close contact with the switch.
Page 70
Installation Manual H3C S5100-SI/EI Series Ethernet Switches Chapter 3 Installing the Switch
3-24
(1)
(2)
(4)
(3)
(1)
(2)
(4)
(3)
(1): Switch (2): Optional module slot (3): XFP interface module (4): Push-in direction
Figure 3-32 Installing an XFP interface module
Step 4: T ighten the fastening scre ws with a screwdriver to fix the XFP interface module.
Note:
z Keep the removed filler panel properly for future use. z When tightening the fastening screws at both sides of the optional module with a
screwdriver or an electric screwdriver, make sure that the torque is not bigger than
0.4N•m.
III. Removal
Step 1: Put on an ESD-preventive wrist strap and verify the ESD-preventive wrist strap properly grounded.
Step 2: Loosen the fasteni ng screws at b oth sides of t he XFP interf ace m odule using a Phillips screwdriver.
Step 3: Pull the XFP interface module towa rds y ou, until it completely comes out of the switch chassis.
Page 71
Installation Manual H3C S5100-SI/EI Series Ethernet Switches Chapter 3 Installing the Switch
3-25
Caution:
When installing or removing an optional interface module, pay attention to the following points:
z Do not use too much force in the operation, and do not touch the surface-mounted
components directly with your hands.
z After removing an optional module, if no new module is to be installed, install the
filler panel as soon as possible to prevent dust and ensure the normal ventilation in the switch.
3.7.2 Stack Module
I. Appearance and front panel
Figure 3-33 Appearance of a stack module
Figure 3-34 Front panel of a stack module
II. Installation and removal
A st ack module is i nst alled and remove d in the same way as yo u inst all and re move an XFP interface module. Refer to section
3.7.1 II. "Installation".
Page 72
Installation Manual H3C S5100-SI/EI Series Ethernet Switches Chapter 3 Installing the Switch
3-26
3.7.3 XENPAK Optical Module
I. Appearance and front panel
Figure 3-35 Appearance of an XENPAK optical module
Figure 3-36 Front panel of an XENPAK optical module
II. Installation
Step 1: Put on an ESD-preventive wrist strap and verify the ESD-preventive wrist strap properly grounded. Then take out the XENPAK optical module from the package.
Step 2: Loosen the two mounting screws on the small cover plate in the middle on the filler panel with a screwdriver and remove the small cover plate.
Note:
When installing an XENPAK optical module, you do not need to remove the whole filler panel. Just remove the small cover plate in the middle on the filler panel.
Step 3: Hold the fastening screws on the front panel of the XENPAK optical module, and gently push the XENPAK optical module in along the slot guide rail until the XENPAK optical module is in close contact with the switch.
Page 73
Installation Manual H3C S5100-SI/EI Series Ethernet Switches Chapter 3 Installing the Switch
3-27
(4)
(2)
(5)
(1)
(3)
(4)
(2)
(5)
(1)
(3)
(4)
(2)
(5)
(1)
(3)
(4)
(2)
(5)
(1)
(3)
(4)
(2)
(5)
(1)
(3)
(1): Switch (2): Filler panels for optional module slots (3): Small cover plate (removed) in the middle on the filler panel (4): Push-in direction (5): XENPAK optical module
Figure 3-37 Installing an XENPAK optical module
Step 4: T ighten the fastening screws on the XENPAK optical module with a screwdriver to fix the XENPAK optical module on the filler panel.
Note:
z Keep the removed small cover plate properly for future use. z When tightening the fastening screws at both sides of the optional module with a
screwdriver or an electric screwdriver, make sure that the torque is not bigger than
0.4N•m.
z Hot swapping of XENPAK optical modules is supported.
III. Removal
Step 1: Put on an ESD-preventive wrist strap and verify the ESD-preventive wrist strap properly grounded.
Step 2: Loosen the fastening screws at both sides of the XENPAK optical module using a flathead screwdriver.
Step 3: Pull the XENPAK optical module towards you, until it completely comes out of the switch chassis.
Page 74
Installation Manual H3C S5100-SI/EI Series Ethernet Switches Chapter 3 Installing the Switch
3-28
3.8 Installing and Removing Dedicated Stack Cables
3.8.1 Introduction
In a stack of the S5100-EI series switches, dedicated stack cables are needed to connect the 10GE stack ports of the switches.
Figure 3-38 Schematic diagram of a dedicated stack cable
The dedicated stack cables for the S5100-EI series are available in three length specifications: 0.5 m (1.6 ft.), 1 m (3.3 ft.), and 3 m (9.8 ft.). You can choose the cables according to the specific needs.
3.8.2 Installation
Note:
Before installing a dedicated stack cable, you need to install 10GE stack cards.
Step 1: Put on an ESD-preventive wrist strap and verify the ESD-preventive wrist strap properly grounded. Then take out the dedicate d stack cable from the package.
Step 2: Insert the plugs of the dedicated stack cable horizontally into the 10GE stack ports of the switches, paying attention to the directions of the plugs.
Step 3: Tighten the fastening screws at both sides of the stack cable plugs using a flathead screwdriver or an electric screwdriver.
3.8.3 Removal
Step 1: Put on an ESD-preventive wrist strap and verify the ESD-preventive wrist strap properly grounded.
Step 2: Loosen the fastening screws at both sides of the stack cable plugs using a flathead screwdriver or an electric screwdriver.
Step 3: Pull out horizont ally the plugs of the dedicated st ack cable from the 10GE st ack ports of the switches.
Page 75
Installation Manual H3C S5100-SI/EI Series Ethernet Switches Chapter 3 Installing the Switch
3-29
Caution:
z The dedicated stack cables for the S5100-EI series are hot-swappable. z When tightening the fastening screws at both sides of the stack cable plugs using a
flathead screwdriver or an electric screwdriver, make sure that the torque is not bigger than 0.4N•m.
z When connecting a stack cable, make sure that the bending radius of cable is at
least eight times of the cable diameter.
3.9 Verifying the Installation
After completing the installation, verify that:
z The correct power source is used. z The ground wire is securely connected. z Both of the console cable and power cord are correctly connected. z All the interface cables are routed indoors. If there are cabl es outdo ors, check that
the socket strip with lightning protection and lightning arresters for network ports have been correctly connected.
Page 76
Installation Manual H3C S5100-SI/EI Series Ethernet Switches Chapter 4 Powering on the Switch for the First Time
4-1
Chapter 4 Powering on the Switch for the First
Time
4.1 Set up the Configuration Environment
Set up the configuration environment as shown in Figure 4-1:
z Connect a terminal, a PC in this example, to the console port on the switch with a
console cable.
PC
Console cable
Switch
Console port
Serial port
PC
Console cable
Switch
Console port
Serial port
Figure 4-1 Network diagram for the first power-on of the switch
4.2 Connecting the Console Cable
Step 1: Plug the DB -9 female connector of the con sole cable to the serial p ort of the PC where the switch is to be configured.
Step 2: Connect the RJ-45 connector of the console cable to the console port of the switch.
4.3 Setting Terminal Parameters
Step 1: Start the PC and run the terminal emulation program such as the Terminal of Windows 3.1 or the HyperTerminal of Windows 95/98/NT/2000/XP.
Step 2: Set terminal parameters (take the HyperTerminal of Windows XP as an example).
Page 77
Installation Manual H3C S5100-SI/EI Series Ethernet Switches Chapter 4 Powering on the Switch for the First Time
4-2
Parameter requirements: Set “Bits per second” to 9600, “Data bits” to 8, “Parity” to “none”, “Stop bits” to 1 and “Flow control” to “none”. Select VT100 as terminal emulation. The specific procedure is as follows:
1) Select [Start/Programs/Accessories/Communications/HyperTerminal] to enter the
HyperTerminal window, where click the
icon to establish a new connection.
The connection description interface appears, as shown below.
Figure 4-2 Connection description of HyperTerminal
2) Type in the name of the new connection in the connection description interface and click <OK>. The system pops up the following interface. Select the se rial port to be used from [Connect using].
Figure 4-3 Setting the serial port used by the HyperTerminal connection
Page 78
Installation Manual H3C S5100-SI/EI Series Ethernet Switches Chapter 4 Powering on the Switch for the First Time
4-3
3) Click <OK> after selecting a serial port and the system pops up the following interface. On the interface, set “Bits per second” to 9600, “Data bits” to 8, “Parity” to “none”, “Stop bits” to 1, and “Flow control” to “none”.
Figure 4-4 Setting serial port parameters
4) Click <OK> after setting the serial port parameters, and the system enters the following interface.
Figure 4-5 HyperTerminal window
Page 79
Installation Manual H3C S5100-SI/EI Series Ethernet Switches Chapter 4 Powering on the Switch for the First Time
4-4
Choose [Properties] in the HyperTerminal dialog box to enter the properties window. Click [Settings] to enter the following properties setting window, select VT100 as the terminal emulation, and then click <OK>.
Figure 4-6 Setting terminal emulation in properties setting window
4.4 Booting the Switch
4.4.1 Checking before Powering on the Switch
Before powering on the switch, verify that:
z The power cords are properly connected. z The power supply voltage is consistent with that required by the switch. z The console cable is properly connected; the terminal (which can be a PC) used
for configuration has been started; and the configuration parameters have been set.
4.4.2 Powering on the Switch
All the S5100 series Ethernet switches have the same BOOT ROM display style. This document uses the Boot ROM display of S5100-48P-EI as an example:
Page 80
Installation Manual H3C S5100-SI/EI Series Ethernet Switches Chapter 4 Powering on the Switch for the First Time
4-5
Starting......
*********************************************************** * * * H3C S5100-48P-EI BOOTROM, Version 616 * * * *********************************************************** Copyright(c) 2004-2007 Hangzhou H3C Technologies Co., Ltd. Creation date : Apr 16 2007, 11:29:53 CPU Clock Speed : 200MHz BUS Clock Speed : 33MHz Memory Size : 64MB Mac Address : 000fe2005100
Press Ctrl-B to enter Boot Menu... 0
The last line asks whether you want to enter the Boot Menu. The system waits two seconds for your response.
Note:
z The system has two startup modes: normal startup and fast startup. The normal
startup mode takes a little longer time than the fast startup mode because of more self-test operations.
z By default, the system starts up in fast startup mode and the waiting time here is two
seconds. if you set the startup mode to normal, this waiting time is five seconds. For the setting of the startup mode, refer to the next section.
If you press <Ctrl + B> within 2 seconds, the Boot Menu is displayed:
BOOT MENU
1. Download application file to flash
2. Select application file to boot
3. Display all files in flash
4. Delete file from flash
5. Modify bootrom password
6. Enter bootrom upgrade menu
7. Skip current configuration file
8. Set bootrom password recovery
9. Set switch startup mode
Page 81
Installation Manual H3C S5100-SI/EI Series Ethernet Switches Chapter 4 Powering on the Switch for the First Time
4-6
0. Reboot
Enter your choice(0-9):
z If you perform no operation or press a key other than <Ctrl + B> within two
seconds, once the remaining waiting time becomes zero, the system begins to automatically start up and the following information is displayed:
Auto-booting...
Decompress Image...................................................
...................................................................
...................................................................
...................................................................
...................................................................
...............................................OK!
Starting at 0x80100000...
User interface aux0 is available.
Press ENTER to get started.
Note:
The setting takes effect only for the first reboot if you choose 7. Skip current
configuration
file in the BOOT MENU.
4.4.3 Changing the Startup Mode
By default, the system starts up in fast mode. If you want to change the startup mode to normal, press <Ctrl + B> within two seconds to enter the Boot Menu showed below:
BOOT MENU
1. Download application file to flash
2. Select application file to boot
3. Display all files in flash
4. Delete file from flash
5. Modify bootrom password
6. Enter bootrom upgrade menu
7. Skip current configuration file
8. Set bootrom password recovery
9. Set switch startup mode
Page 82
Installation Manual H3C S5100-SI/EI Series Ethernet Switches Chapter 4 Powering on the Switch for the First Time
4-7
0. Reboot
Enter your choice(0-9):
Enter 9, and the system prompts you to change the startup mode:
The current mode is fast startup mode! Are you sure to change it to full startup mode? Yes or No(Y/N)
Enter Y. The system displays the following information:
Setting startup mode...done! BOOT MENU
1. Download application file to flash
2. Select application file to boot
3. Display all files in flash
4. Delete file from flash
5. Modify bootrom password
6. Enter bootrom upgrade menu
7. Skip current configuration file
8. Set bootrom password recovery
9. Set switch startup mode
0. Reboot
Enter your choice(0-9):
Enter 0. The system reboots in normal mode and displays the following information:
Starting......
*********************************************************** * * * H3C S5100-48P-EI BOOTROM, Version 616 * * * *********************************************************** Copyright(c) 2004-2007 Hangzhou H3C Technologies Co., Ltd. Creation date : Apr 16 2007, 11:29:53 CPU Clock Speed : 200MHz BUS Clock Speed : 33MHz Memory Size : 64MB Mac Address : 000fe2005100
Press Ctrl-B to enter Boot Menu... 5
In normal startup mode, the waiting time here is five seconds. If you press <Ctrl + B> within five seconds, the Boot Menu is displayed: If you perform no operation or press a
Page 83
Installation Manual H3C S5100-SI/EI Series Ethernet Switches Chapter 4 Powering on the Switch for the First Time
4-8
key other than <Ctrl + B> within five seconds, the system begins to automatically start up and the following information is displayed:
Auto-booting...
Decompress Image..........................................................
..........................................................................
..........................................................................
..........................................................................
..........................................................................
..........................................................................
...OK! Starting at 0x80100000...
Initialize LS51LTSG........................OK!
SDRAM fast selftest........................OK!
Flash fast selftest........................OK!
CPLD selftest..............................OK!
Switch chip selftest.......................OK!
Port 1 has no module Port 2 has no module Port 3 has no module Port 4 has no module
PHY selftest...............................OK!
Please check port leds...............FINISHED!
User interface aux0 is available.
Press ENTER to get started.
The appearance of "Press ENTER to get started" indi cates that the automatic startup of the switch is complete.
Press <Enter>. The following prompt is displayed:
<H3C>
You can configure the switch now.
Page 84
Installation Manual H3C S5100-SI/EI Series Ethernet Switches Chapter 4 Powering on the Switch for the First Time
4-9
Note:
The H3C Series Switches provides abundant command views. For detailed descriptions about the configuration commands and CLI, refer to
H3C S5100 Series
Ethernet Switches Operation Manual
and H3C S5100 Series Ethernet Switches
Command Manual
.
Page 85
Installation Manual H3C S5100-SI/EI Series Ethernet Switches Chapter 5 Boot ROM and Host Software Loading
5-1
Chapter 5 Boot ROM and Host Software Loading
Traditionally, the loading of switch software is accomplished through the serial port. This approach is slow, inconvenient, and cannot be used for remote real-time loading. To solve these problems, the TFTP and FTP modules are introduced into the switch. With these modules, the software and files can be loaded through Ethernet port conveniently.
This chapter introduces how to load The Boot ROM and host software into a switch locally and how to do this remotely.
5.1 Introduction to Loading Modes
You can load the software locally by using:
z XModem through console port z TFTP through Ethernet port z FTP through Ethernet port
You can load the software remotely by using:
z FTP z TFTP
Note:
The Boot ROM software version should match the host software version when you load the Boot ROM and host software.
5.2 Local Software Loading
If your terminal is directly connected to the switch, you can load The Boot ROM and host software locally.
Before loading the software, make sure that your terminal is correctly connected to the switch to insure successful software loading.
Page 86
Installation Manual H3C S5100-SI/EI Series Ethernet Switches Chapter 5 Boot ROM and Host Software Loading
5-2
Note:
The loading process of the Boot ROM software is the same as that of the host software, except that during the Boot ROM loading process, you should enter the different digit after entering the Boot Menu and the system gives somewhat different prompts. The following text mainly describes the Boot ROM loading process.
5.2.1 Boot Menu
Starting......
*********************************************************** * * * H3C S5100-48P-EI BOOTROM, Version 616 * * * ***********************************************************
Copyright(c) 2004-2007 Hangzhou H3C Technologies Co., Ltd. Creation date : Apr 16 2007, 11:29:53 CPU type : BCM5836 CPU Clock Speed : 200MHz BUS Clock Speed : 33MHz Memory Size : 64MB Mac Address : 000fe2005100
Press Ctrl-B to enter Boot Menu... 5
Press <Ctrl + B>. The system displ ays:
Password :
Note:
To enter the Boot Menu, you should press <Ctrl+B> within five seconds after the information “Press Ctrl-B to enter Boot Menu...” appears. Otherwise, the system starts to decompress the program; and if you want to enter the Boot Menu at this time, you will have to restart the switch.
Page 87
Installation Manual H3C S5100-SI/EI Series Ethernet Switches Chapter 5 Boot ROM and Host Software Loading
5-3
Input the correct Boot ROM password (by default, no password is set on the switch). The system enters the Boot Menu:
BOOT MENU
1. Download application file to flash
2. Select application file to boot
3. Display all files in flash
4. Delete file from flash
5. Modify bootrom password
6. Enter bootrom upgrade menu
7. Skip current configuration file
8. Set bootrom password recovery
9. Set switch startup mode
0. Reboot
Enter your choice(0-9):
5.2.2 Loading Software Using XModem Through Console Port
I. Introduction to XModem
XModem is a file transfer protocol that is widely used due to its simplicity and good performance. XModem transfers files through console port. It supports two types of data packets (128 bytes and 1 KB), two check methods (checksum and CRC), and error packet retransmission mechanism (generally the maximum number of retransmission attempts is ten).
The XModem transmission procedure is completed by the cooperation of a receiving program and a sending program. The receiving program sends a n egotiation p acket to negotiate a packet check method. After the negotiation, the sending program starts to transmit data packets. When receiving a complete packet, the receiving program checks the packet using the agreed method. If the check succeeds, the receiving program sends an acknowledgement packet and the sending program proceeds to send another packet; otherwise, the receiving program sends a negative acknowledgement packet and the sending program retransmits the packet.
II. Loading Boot ROM software
Step 1: At the prompt "Enter your choice(0-9):" select 6 in the Boot Menu and then press <Enter> to enter the Boot ROM update menu shown below:
Bootrom update menu:
1. Set TFTP protocol parameter
2. Set FTP protocol parameter
3. Set XMODEM protocol parameter
0. Return to boot menu
Page 88
Installation Manual H3C S5100-SI/EI Series Ethernet Switches Chapter 5 Boot ROM and Host Software Loading
5-4
Enter your choice(0-3):
Step 2: Enter 3 in the above menu to loa d the Boot ROM soft ware using XMod em. The system displays the following download baud rate setting menu:
Please select your download baudrate:
1.* 9600
2. 19200
3. 38400
4. 57600
5. 115200
0. Return
Enter your choice (0-5):
Step 3: Choose an appropriate download baud rate. For example, if you enter 5, the 1 15 200 bps rate is chosen, and the system displays the following information:
Download baudrate is 115200 bps Please change the terminal's baudrate to 115200 bps and select XMODEM protocol Press enter key when ready
Now, press <Enter>.
Note:
If you have chosen 9600 bps, you do not need to modify the HyperTerminal’s baud rate, and therefore you can skip Step 4 and 5 below and proceed to Step 6 directly. In this case, the system will not display the above information.
Step 4: Choose [File/Properties] in HyperTerminal, click <Configuration> in the popup dialog box, select the baud rate of 115200 bps in the appeared console port configuration dialog box.
Page 89
Installation Manual H3C S5100-SI/EI Series Ethernet Switches Chapter 5 Boot ROM and Host Software Loading
5-5
Figure 5-1 Properties dialog box
Figure 5-2 Console port configuration dialog box
Step 5: After setting the baud rate, you need to disconnect and the reconnect HyperTerminal so that the baud rate setting takes effect. Click the <Disconnect> button
Page 90
Installation Manual H3C S5100-SI/EI Series Ethernet Switches Chapter 5 Boot ROM and Host Software Loading
5-6
to disconnect the HyperTerminal from the switch and then click the <Call> button to reconnect the HyperTerminal to the switch.
Figure 5-3 Call and disconnect buttons
Note:
The new baud rate takes effect only after you disconnect and reconnect the terminal emulation program.
Step 6: Press <Enter> to start downloading the program. The system displays the following information:
Now please start transfer file with XMODEM protocol. If you want to exit, Press <Ctrl+X>. Loading ...CCCCCCCCCC
Step 7: Choose [Transfer/Send File] in the HyperTerminal’s window, and in the following popup dialog box click <Browse>, select the software you need to download, and set the protocol to XModem.
Figure 5-4 Send file dialog box
Step 8: Click <Send>. The system displays the following page.
Page 91
Installation Manual H3C S5100-SI/EI Series Ethernet Switches Chapter 5 Boot ROM and Host Software Loading
5-7
Figure 5-5 Send file page
Step 9: After the download completes, the system displays the following information:
Loading ...CCCCCCCCCC done!
Note:
You do not need to reset the HyperTerminal’s baud rate and can ski p the last step if you have chosen 9600 bps. In this case, the system display the prompt “BootROM is
updating now.....................................done!” instead of the prompt "Your baudrate
should be set to 9600 bps again! Press enter key when ready".
Step 10: Reset HyperTerminal’s baud rate to 9600 bps (refer to Step 4 and 5). Then, press any key as prompted. The system will display the following information when it completes the loading.
Bootrom updating.....................................done!
III. Loading host software
Step 1: Select 1 in Boot Menu. The system displays the following information:
1. Set TFTP protocol parameter
2. Set FTP protocol parameter
3. Set XMODEM protocol parameter
0. Return to boot menu
Enter your choice(0-3):3
To load the host software through XModem, select 3.
Page 92
Installation Manual H3C S5100-SI/EI Series Ethernet Switches Chapter 5 Boot ROM and Host Software Loading
5-8
The subsequent steps are the same as those for loading the Boot ROM software, except that the system gives the prompt for host software loading instead of Boot ROM loading.
5.2.3 Loading Software Using TFTP through Ethernet Port
I. Introduction to TFTP
Trivial File Transfer Protocol (TFTP), a protocol in TCP/IP protocol suite, is used for trivial file transfer between client and server. It uses UDP to provide unreliable data stream transfer service.
II. Loading Boot ROM software
TFTP Client
Switch
PC
Server
Console port Ethernet port
TFTP Server
TFTP Client
Switch
PC
Server
Console port Ethernet port
TFTP Server
Figure 5-6 Local loading using TFTP
Step 1: As shown in
Figure 5-6, connect the switch through an Ethernet port to the
TFTP server, and connect the switch through the console port to the configuration PC.
Note:
You can use one PC as both configuration device and TFTP server.
Step 2: Run the TFTP server program on the TFTP server, and specify the path of the program to be loaded.
Caution:
TFTP server program is not provided with the H3C Series Switches.
Step 3: Run the terminal emulation program on the configuration PC. Start the switch. Then enter the Boot Menu. At the prompt "Enter your choice(0-9):" select 6 in the Boot Menu and then press <Enter> to enter the Boot ROM update menu shown below:
Bootrom update menu:
1. Set TFTP protocol parameter
Page 93
Installation Manual H3C S5100-SI/EI Series Ethernet Switches Chapter 5 Boot ROM and Host Software Loading
5-9
2. Set FTP protocol parameter
3. Set XMODEM protocol parameter
0. Return to boot menu
Enter your choice(0-3):
Step 4: Select 1 to download the Boot ROM software using TFTP. Then set the following TFTP-related parameters as required:
Load File name :S5100.btm Switch IP address :1.1.1.2 Server IP address :1.1.1.1
Step 5: Press <Enter>. The system displays the following information:
Are you sure to update your bootrom?Yes or No(Y/N)
Step 6: Enter Y to st art file downloading or N to return to the Boot ROM update menu. If you enter Y, the system begins to download and update the Boot ROM software. Upon completion, the system displays the following information:
Loading........................................done
Bootrom updating..........done!
III. Loading host software
Step 1: Select 1 in Boot Menu. The system displays the following information:
1. Set TFTP protocol parameter
2. Set FTP protocol parameter
3. Set XMODEM protocol parameter
0. Return to boot menu
Enter your choice(0-3):1
To load the host software through TFTP, select 1. The subsequent steps are the same as those for loading the Boot ROM software,
except that the system gives the prompt for host software loading instead of Boot ROM loading.
5.2.4 Loading Software Using FTP Through Ethernet Port
I. Introduction to FTP
File Transfer Protocol (FTP) is an appli cation-layer protocol in the TCP/IP protocol suite. It is used for transferring files between server and client, and is widely used in IP networks.
Y ou can use FTP to load soft ware onto the switch through an Ethernet port. In this case, the switch can act as an FTP server or an FTP client. In the following example, the switch acts as an FTP client.
Page 94
Installation Manual H3C S5100-SI/EI Series Ethernet Switches Chapter 5 Boot ROM and Host Software Loading
5-10
II. Loading Boot ROM software
FTP Client
Switch
PC
Server
Console port Ethernet port
FTP Server
FTP Client
Switch
PC
Server
Console port Ethernet port
FTP Server
Figure 5-7 Local loading using FTP
Step 1: As shown in
Figure 5-7, connect the switch through an Ethernet port to the FTP
server, and connect the switch th rough the console port to the configuration PC.
Note:
You can use one PC as both configuration device and FTP server.
Step 2: Run the FTP server program on the FTP server, configure an FTP user name and password, and specify the path of the program to be downloaded.
Step 3: Run the terminal emulation program on the configuration PC. Start the switch. Then enter the Boot Menu.
At the prompt "Enter your choice(0-9):" select 6 in the Boot Menu, and then press <Enter> to enter the Boot ROM update menu shown below:
Bootrom update menu:
1. Set TFTP protocol parameter
2. Set FTP protocol parameter
3. Set XMODEM protocol parameter
0. Return to boot menu
Enter your choice(0-3):
Step 4: Enter 2 in the above menu to download the Boot ROM software using FTP. Then set the following FTP-related parameters as required:
Load File name :S5100.btm Switch IP address :10.1.1.2 Server IP address : 10.1.1.1 FTP User Name :5100 FTP User Password :abc
Step 5: Press <Enter>. The system displays the following information:
Are you sure to update your bootrom?Yes or No(Y/N)
Page 95
Installation Manual H3C S5100-SI/EI Series Ethernet Switches Chapter 5 Boot ROM and Host Software Loading
5-11
Step 6: Enter Y to st art file downloading or N to return to the Boot ROM update menu. If you enter Y, the system begins to download and update the program. Upon completion, the system displays the following information:
Loading........................................done
Bootrom updating..........done!
III. Loading host software
Step 1: Select 1 in Boot Menu. The system displays the following information:
1. Set TFTP protocol parameter
2. Set FTP protocol parameter
3. Set XMODEM protocol parameter
0. Return to boot menu
Enter your choice(0-3):2
To load the host software through FTP, select 2. The subsequent steps are the same as those for loading the Boot ROM software,
except that the system gives the prompt for host software loading instead of Boot ROM loading.
5.3 Remote Software Loading
If your terminal is indirectly connected to the switch through Internet, you can telnet to the switch, and use FTP or TFTP to load The Boot ROM and host software remotely.
5.3.1 Remote Loading Using FTP
As shown in Figure 5-8, a PC is used as both configuration device and FTP server . You can telnet to the switch, and then execute the FTP commands to download the host program s5100.bin and the Boot ROM program s5100.btm from the remote FTP server (with IP address 10.1.1.1) to the switch.
FTP C lient
Switch
PC
Ethernet port
FTP Server
10.1.1.1
Inter n e t
FTP C lient
Switch
PC
Ethernet port
FTP Server
10.1.1.1
Inter n e t
Figure 5-8 Remote loading using FTP
Step 1: Download the sof tware to the switch using FTP commands.
Page 96
Installation Manual H3C S5100-SI/EI Series Ethernet Switches Chapter 5 Boot ROM and Host Software Loading
5-12
<H3C> ftp 10.1.1.1 Trying ... Press CTRL+K to abort Connected. 220 WFTPD 2.0 service (by Texas Imperial Software) ready for new user User(none):abc 331 Give me your password, please Password: 230 Logged in successfully [ftp] get s5100.bin [ftp] get s5100.btm [ftp] bye
Step 2: Update the Boot ROM program on the switch.
<H3C> boot bootrom s5100.btm please wait ... Bootrom is updated!
Step 3: Update the host software on the switch.
<H3C> boot boot-loader s5100.bin <H3C> display boot-loader Unit 1: The current boot app is: s5100.bin The main boot app is: s5100.bin The backup boot app is:
Step 4: Restart the switch.
<H3C> reboot
Note:
Before restarting the switch, make sure other configurations are all saved to avoid the loss of configuration information.
After the steps above, the Boot ROM and host software loading is completed. Pay attention to the following points:
z Host software loading takes ef fect only after you re start the swit ch with the reboot
command.
z If the space of the flash memory is not enough, you can delete the useless files in
the flash memory before software downloading.
z Power interruption is not allowed during software loading.
Page 97
Installation Manual H3C S5100-SI/EI Series Ethernet Switches Chapter 5 Boot ROM and Host Software Loading
5-13
5.3.2 Remote Loading Using TFTP
The remote loading by using TFTP is similar to the remote loading by using FTP. The only difference is that it is TFTP that you use when loading software to the switch. In this case, the switch can only be used as a TFTP client.
Page 98
Installation Manual H3C S5100-SI/EI Series Ethernet Switches Chapter 6 Maintenance and Troubleshooting
6-1
Chapter 6 Maintenance and Troubleshooting
6.1 Software Loading Failure
If software loading fails, the system keeps running in original version. In this case, check if the physical ports are properly connected:
z If the ports are not properly connected, reconnect them correctly and restart the
loading procedure.
z If the ports are properly connected, check the loading procedure information
displayed on the HyperTerminal for input errors. If there is any input error, restart the loading procedure with correct input. For example, when u sing XModem, verify that you have reset the baud rate of the HyperTerminal to 9600 bps after loading the software with a baud rate other than 9600 bps; when using TFTP, verify that you have specified the correct server and switch IP addresses, the correct name of the software to be loaded and the correct working path of TFTP server; when using FTP, verify that you have specified the correct server and switch IP addresses, the correct name of the software to be loaded and the correct username and password.
If software loading fails but there are neither physical connection problems nor input errors, please contact your agent for help.
6.2 Missing Password
6.2.1 Missing user password
If you have forgotten your user password, you can enter the Boot Menu:
BOOT MENU
1. Download application file to flash
2. Select application file to boot
3. Display all files in flash
4. Delete file from flash
5. Modify bootrom password
6. Enter bootrom upgrade menu
7. Skip current configuration file
8. Set bootrom password recovery
9. Set switch startup mode
0. Reboot
Enter your choice(0-9):
Page 99
Installation Manual H3C S5100-SI/EI Series Ethernet Switches Chapter 6 Maintenance and Troubleshooting
6-2
Select 7, and then restart the switch. After the switch is restarted, the configuration file will be skipped.
6.2.2 Missing Boot ROM Password
Please contact your switch dealer.
6.3 Power Supply Failure
You can check whether the power system of the switch fails by viewing the PWR LED on the front panel. When the power supply system functions normally, the PWR LED should stay on. Otherwise, please check whether
z The switch power cord is properly connected. z The power input to the switch matches the requirement as labeled on the switch.
6.4 Configuration System Failure
After the switch is powered on and the system is normal, the booting information will be displayed on the configuration terminal. If the configuration system has any faults, there will not be any screen display at the configuration terminal or the displayed characters will be totally illegible.
I. Troubleshooting when there is no terminal display
If there is no output information after the configuration is powered on, please check whether:
z The power supply is normal z The console cable is properly connected
If no problems are found after the above-mentioned items have been checked, the cause may lie in the console cable or the settings of the terminal (such as hyper terminal) parameters. Please perform the corresponding check.
II. Troubleshooting when the terminal display is illegible
If there is illegible display at the configuration terminal, the cause might lie in the parameter setting error at the terminal (such as HyperTerminal). Verify the following terminal parameter (such as hyper terminal) settings:
z Bits per second: 9600 z Data bits: 8 z Parity: none z Stop bits: 1 z Flow control: none z Terminal emulation: VT100
Page 100
Installation Manual H3C S5100-SI/EI Series Ethernet Switches Table of Contents
i
Table of Contents
Appendix A Lightning Protection of the Switch.........................................................................A-1
A.1 Installation of Lightning Arrester for AC Power (Socket Strip with Lightning Protection)..A-1
A.2 Installation of Lightning Arrester for Network Port.............................................................A-2
Loading...