H3C S7503 S7506 AND S7506R SWITCH, LS8M1VSNPH, S7502 Installation Manual

H3C S7502 Ethernet Switch
Installation Manual
Hangzhou H3C Technologies Co., Ltd.
http://www.h3c.com
Manual Version: T2-08046H-20071205-C-1.02
Copyright © 2006-2007, Hangzhou H3C Techn ologies Co ., Ltd.
All Rights Reserved
No part of this manual may be reproduced or transmitted in any form or by any means without prior written consent of Hangzhou H3C Technologies Co., Ltd.
Trademarks
H3C, , Aolynk, , H3Care,
, TOP G, , IRF, NetPilot, Neocean, NeoVTL, SecPro, SecPoint, SecEngine, SecPath, Comware, Secware, Storware, NQA, VVG, V
2
G, VnG, PSPT, XGbus, N-Bus, TiGem, InnoVision and
HUASAN are trademarks of Hangzhou H3C Technologies Co., Ltd.
All other trademarks that may be mentioned in this manual are the property of their respective owners.
Notice
The information in this document is subject to change without notice. Every effort has been made in the preparation of this document to ensure accuracy of the contents, but all statements, information, and recommendations in this document do not constitute the warranty of any kind, express or implied.
To obtain the latest information, please access:
http://www. h3c.com
Technical Support
customer_service@h3c.com
http://www. h3c.com
About This Manual
Related Documentation
In addition to this manual, each H3C S7502 Ethernet Switch documentation set includes the following:
Manual Description
H3C S7500 Series Ethernet Switches Operation Manual
Guides the user to configure the features supported by the S7500 series.
H3C S7500 Series Ethernet Switches Command Manual
Elaborates on the commands for configuring the S7500 series.
Organization
H3C S7502 Ethernet Switch Installation Manual is organized as follows:
Chapter Contents
1 Product Overview
Introduces the characteristics of the H3C S7502 Ethernet switch.
2 Line Processing Units
Introduces LPUs of the H3C S7502 Ethernet switch.
3 Installation Preparations
Introduces the preparations and precautions for the H3C S7502 Ethernet switch installation.
4 Hardware Installation
Introduces the integrated equipment installation and cable connection (including connection of grounding cables, power cables, and interface cables, recommended cabling, and cable binding) of the H3C S7502 Ethernet switch.
5 System Commissioning
Introduces the initial power-on startup process of the H3C S7502 Ethernet switch.
6 Hardware Maintenance
Introduces the removal and installation of power modules, LPUs, fan tray, and delivered cable management brackets of the H3C S7502 Ethernet switch.
7. Software Maintenance
Introduces how to load and upgrade software of the H3C S7502 Ethernet switch.
Chapter Contents
8. Troubleshooting
Introduces how to troubleshoot the configuration system, power system, fans, and LPUs of the H3C S7502 Ethernet Switch.
Appendix A Lightning Protection
Introduces lightning protection of the H3C S7502 Ethernet switch.
Appendix B AC Power Cables Used in Different Countries
Introduces the AC power cables used in different countries, including 10A AC power cables and 16A AC power cables.
Conventions
The manual uses the following conventions:
I. GUI conventions
Convention Description
< >
Button names are inside angle brackets. For example, click <OK>.
[ ]
Window names, menu items, data table and field names are inside square brackets. For example, pop up the [New User] window.
/
Multi-level menus are separated by forward slashes. For example, [File/Create/Folder].
II. Symbols
Convention Description
Warning
Means reader be extremely careful. Improper operation may cause bodily injury.
Caution
Means reader be careful. Improper operation may cause data loss or damage to equipment.
Note Means a complementary description.
Environmental Protection
This product has been designed to comply with the requirements on environmental protection. For the proper storage, use and disposal of this product, national laws and regulations must be observed.
Installation Manual H3C S7502 Ethernet Switch Table of Contents
i
Table of contents
Chapter 1 Product Overview........................................................................................................1-1
1.1 General Information...........................................................................................................1-1
1.1.1 Preface.................................................................................................................... 1-1
1.1.2 Switching Engine..................................................................................................... 1-2
1.1.3 SRPU Specifications...............................................................................................1-2
1.2 LS81P12TE........................................................................................................................1-3
1.2.1 Specifications..........................................................................................................1-3
1.2.2 Panel and LEDs ...................................................................................................... 1-4
1.2.3 Port Cable ............................................................................................................... 1-5
1.3 LS81T12PE........................................................................................................................1-6
1.3.1 Specifications..........................................................................................................1-7
1.3.2 Panel and LEDs ...................................................................................................... 1-7
1.3.3 Port Cable ............................................................................................................... 1-8
1.4 LS81T16P.......................................................................................................................... 1-9
1.4.1 Specifications..........................................................................................................1-9
1.4.2 Panel and LEDs .................................................................................................... 1-10
1.4.3 Port Cable ............................................................................................................. 1-11
1.5 LS81T32P........................................................................................................................ 1-11
1.5.1 Specifications........................................................................................................1-11
1.5.2 Panel and LEDs .................................................................................................... 1-12
1.5.3 Port Cable ............................................................................................................. 1-13
1.6 LS81GT48B.....................................................................................................................1-13
1.6.1 Specifications........................................................................................................1-13
1.6.2 Panel and LEDs .................................................................................................... 1-14
1.6.3 Port Cable ............................................................................................................. 1-15
1.7 LS81GP48 ....................................................................................................................... 1-15
1.7.1 Specifications........................................................................................................1-15
1.7.2 Panel and LEDs .................................................................................................... 1-16
1.7.3 Port Cable ............................................................................................................. 1-17
1.8 LS81TGX2.......................................................................................................................1-17
1.8.1 Specifications........................................................................................................1-17
1.8.2 Panel and LEDs .................................................................................................... 1-18
1.8.3 Port Cable ............................................................................................................. 1-19
1.9 LS81TGX4.......................................................................................................................1-19
1.9.1 Specifications........................................................................................................1-19
1.9.2 Panel and LEDs .................................................................................................... 1-20
1.9.3 Port Cable ............................................................................................................. 1-21
1.10 LPUs Supported by SRPUs........................................................................................... 1-21
Installation Manual H3C S7502 Ethernet Switch Table of Contents
ii
1.11 Physical Description of the S7502................................................................................. 1-23
1.11.1 Chassis and Slots ............................................................................................... 1-23
1.11.2 Color Description on the Fan Tray and Cards .................................................... 1-27
1.11.3 Backplane............................................................................................................1-28
1.11.4 Power Supply System.........................................................................................1-28
1.11.5 PoE Power Supply..............................................................................................1-29
1.11.6 Fan Tray.............................................................................................................. 1-30
1.12 Technical Specifications ................................................................................................ 1-31
Installation Manual H3C S7502 Ethernet Switch Chapter 1 Product Overview
1-1
Chapter 1 Product Overview
1.1 General Information
1.1.1 Preface
H3C S7500 Series Ethernet Switches are modular, large-capacity Layer 2/3 Ethernet switches that support wire-speed forwarding. The S7500 series include S7502, S7503, S7506, and S7506R.
z The S7503, S7506, and S7506R are designed to operate at the convergence layer
of IP metropolitan area networks (MANs) and at the core layer of small to medium-sized enterprise networks and campus area networks.
z The S7502 is designed to operate at the core layer of small to medium-sized
enterprise networks and at the convergence layer and access layer of IP MANs.
The S7502 is a high-capacity, cost-effective Layer 3 Ethernet switch. It provides high-density GE/FE ports, as well as modularized components that enable you to configure flexibly according to your specific needs.
Figure 1-1 S7502 in a MAN
The S7502 supports 1+1 AC power redundancy backup, and provides one switching and routing processing unit (SRPU) slot and one line processing unit (LPU) slot. Both the SRPU and the LPU can provide high-density service ports.
Installation Manual H3C S7502 Ethernet Switch Chapter 1 Product Overview
1-2
1.1.2 Switching Engine
Switching engine (also known as SRPU) is the core of the S7502. Currently, switching engines include the following models:
z LS81P12TE: provides four 10/100/1000Base-T ports and twelve 1000Base-X
(SFP) ports.
z LS81T12PE: provides twelve 10/100/1000Base-T ports and four 1000Base-X
(SFP) ports.
z LS81T16P: provides sixteen 10/100/1000Base-T ports and eight 1000Base-X
(SFP) ports, and supports XG high-speed bus.
z LS81T32P: provides thirty-two 10/100/1000Base-T ports and sixteen 1000Base-X
(SFP) ports, and supports XG high-speed bus.
z LS81GT48B: provides forty-eight 10/100/1000Base-T ports, and supports XG
high-speed bus.
z LS81GP48: provides forty-eight 1000Base-X (SFP) ports, and supports XG
high-speed bus.
z LS81TGX2: provides two 10GBase-XFP ports, and supports XG high-speed bus. z LS81TGX4: provides four 10GBase-XFP ports and supports XG high-speed bus.
Note:
You can insert an SRPU into the second slot (slot 1) of the S7502 to serve as an LPU.
Generally an SRPU can provide these functions:
z L2/L3 data forwarding between LPUs z Route calculation z LPU monitoring z Processing of the monitoring signals on the power system and fans
1.1.3 SRPU Specifications
The following table lists the SRPU specifications.
Table 1-1 SRPU specifications
Item
Switching
capacity
Packet
forwarding
rate
Number
of VLANs
MAC
address
table
Routing
table
LS81T12PE 48 Gbps 36 Mpps 4 K 16 K 64 K LS81P12TE 48 Gbps 36 Mpps 4 K 16 K 64 K LS81T16P 144 Gbps 108 Mpps 4 K 16 K 64 K
Installation Manual H3C S7502 Ethernet Switch Chapter 1 Product Overview
1-3
Item
Switching
capacity
Packet
forwarding
rate
Number
of VLANs
MAC
address
table
Routing
table
LS81T32P 192 Gbps 144 Mpps 4 K 16 K 64 K LS81GT48B 192 Gbps 144 Mpps 4 K 16 K 64 K LS81GP48 192 Gbps 144 Mpps 4 K 16 K 64 K LS81TGX2 144 Gbps 108 Mpps 4 K 16 K 64 K LS81TGX4 192 Gbps 144 Mpps 4 K 16 K 64 K
1.2 LS81P12TE
Figure 1-2 Appearance of an LS81P12TE
1.2.1 Specifications
Table 1-2 LS81P12TE specifications
Item LS81P12TE
CPU MPC8245 300 MHz Boot ROM 512 KB Flash memory 32 MB SDRAM 256 MB Dimensions (H × W x D)
40.1 × 376.7 × 354.5 mm (1.6 × 14.8 × 14 in.)
Port
z 4 × 10/100/1000Base-T Ethernet ports z 12 × 1000Base-X (SFP) Ethernet ports
Max power consumption 40 W
Port rate
z 1000 Mbps full duplex (optical port) z 10 Mbps half/full duplex (electrical port) z 100 Mbps half/full duplex (electrical port) z 1000 Mbps full duplex (electrical port)
SFP module Refer to Table 1-4
Installation Manual H3C S7502 Ethernet Switch Chapter 1 Product Overview
1-4
Item LS81P12TE
Ethernet port cable and max transmission distance
100 m (328 ft) over category-5 twisted pair cable
Supported standard
z IEEE 802.3 z IEEE 802.3u z IEEE 802.3z z IEEE 802.3ab z IEEE 802.1p z IEEE 802.1Q z IEEE 802.1D z IEEE802.1X z IEEE802.1s z IEEE802.1w z IEEE 802.3x z IEEE 802.3ad
Note:
In this manual, card dimensions refer to those of a card with ejector levers.
1.2.2 Panel and LEDs
LS81P12TE has four 10/100/1000Base-T ports and twelve 1000Base-X (SFP) ports; each has a status LED with it.
Figure 1-3 illustrates the panel of an LS81P12TE.
Figure 1-3 LS81P12TE panel
(1)
(2)
(5)(6)
(3)
(4)
(7)(8)
(1) Interface number (2) Silkscreen (3) Nut (4) LPU edge (Green) (5) Ejector lever (6) Interface status indicator (7) SPF port (Gigabit) (8) Ethernet port (Gigabit)
Figure 1-4 LS81P12TE panel
Installation Manual H3C S7502 Ethernet Switch Chapter 1 Product Overview
1-5
The status LEDs on an LS81P12TE are described in the following table.
Table 1-3 Description of LEDs on the panel of an LS81P12TE
LED Status
OFF The link is down or no link is presented. ON The link is active.
LINK/ACT
Blinking Data is being transmitted or received on the port.
1.2.3 Port Cable
I. Optical port cables for 12-port 1000Base-X (SFP)
Table 1-4 Description of 1000Base-X (SFP) port cables
SFP module
Central
wavelength
Connector
Matching
cable
Maximum
transmission
distance
50 µm/125 µm multimode optical fiber cable
550 m (1804 ft)
SFP-GE-SX-MM 850-A
850 nm LC
62.5 µm/125 µm multimode optical fiber cable
275 m (902 ft)
SFP-GE-LX-SM 1310-A
10 km (6 mi)
SFP-GE-LH40-S M1310
1310 nm LC
9 µm/125 µm single mode optical fiber cable
40 km (about 25 mi)
SFP-GE-LH40-S M1550
40 km (about 25 mi)
SFP-GE-LH70-S M1550
70 km (43 mi)
SFP-GE-LH100­SM1550
1550 nm LC
9 µm/125 µm single mode optical fiber cable
100 km (62 mi)
SFP-GE-LH70-S M1470-CW
1470 nm LC
9 µm/125 µm single mode optical fiber cable
70 km (43 mi)
SFP-GE-LH70-S M1490-CW
1490 nm LC
9 µm/125 µm single mode optical fiber cable
70 km (43 mi)
Installation Manual H3C S7502 Ethernet Switch Chapter 1 Product Overview
1-6
SFP module
Central
wavelength
Connector
Matching
cable
Maximum
transmission
distance
SFP-GE-LH70-S M1510-CW
1510 nm LC
9 µm/125 µm single mode optical fiber cable
70 km (43 mi)
SFP-GE-LH70-S M1530-CW
1530 nm LC
9 µm/125 µm single mode optical fiber cable
70 km (43 mi)
SFP-GE-LH70-S M1550-CW
1550 nm LC
9 µm/125 µm single mode optical fiber cable
70 km (43 mi)
SFP-GE-LH70-S M1570-CW
1570 nm LC
9 µm/125 µm single mode optical fiber cable
70 km (43 mi)
SFP-GE-LH70-S M1590-CW
1590 nm LC
9 µm/125 µm single mode optical fiber cable
70 km (43 mi)
SFP-GE-LH70-S M1610-CW
1610 nm LC
9 µm/125 µm single mode optical fiber cable
70 km (43 mi)
SFP-GE-T RJ45 100 m (328 ft)
II. Ethernet port cable for 4-port 10/100/1000Base-T
The Ethernet port cable is category-5 twisted pair cable, ended with RJ45 connectors, whose maximum transmission distance is 100 m.
1.3 LS81T12PE
Figure 1-5 Appearance of LS81T12PE
Installation Manual H3C S7502 Ethernet Switch Chapter 1 Product Overview
1-7
1.3.1 Specifications
Table 1-5 LS81T12PE specifications
Item LS81P12TE
CPU MPC8245 300 MHz Boot ROM 512 KB Flash memory 32 MB SDRAM 256 MB Dimensions (H × W x D)
40.1 × 376.7 × 354.5 mm (1.6 × 14.8 × 14 in.)
Port
z 12 × 10/100/1000Base-T Ethernet ports z Four 1000Base-X (SFP) Ethernet ports
Max power consumption 45 W Connector RJ-45, LC Number of ports 16
Port rate
z 1000 Mbps full duplex (optical port) z 10 Mbps half/full duplex (electric port) z 100 Mbps half/full duplex (electric port) z 1000 Mbps full duplex (electric port)
SFP module Refer to Table 1-4 Port cable and max transmission
distance
100 m (328 ft) over category-5 twisted pair cable
Supported standard
z IEEE 802.3 z IEEE 802.3u z IEEE 802.3z z IEEE 802.3ab z IEEE 802.1p z IEEE 802.1Q z IEEE 802.1D z IEEE802.1X z IEEE802.1s z IEEE802.1w z IEEE 802.3x z IEEE 802.3ad
1.3.2 Panel and LEDs
LS81T12PE has 12 × 10/100/1000Base-T ports and four 1000Base-X (SFP) ports; each has a status LED with it.
Figure 1-6 illustrates the panel of an LS81T12PE.
Installation Manual H3C S7502 Ethernet Switch Chapter 1 Product Overview
1-8
Figure 1-6 LS81T12PE panel
(1) (2)
(5)(6)(7)
(3)
(4)
(8)
(1) Interface number (2) Silkscreen (3) Nut (4) LPU edge (Green) (5) Ejector lever (6) SPF port (Gigabit) (7) Interface status LED (8) Ethernet port (Gigabit)
Figure 1-7 LS81T12PE panel
The status LEDs on an LS81T12PE are described in
Table 1-6.
Table 1-6 Description of LEDs on the panel of an LS81T12PE
LED Status
OFF The link is down or no link is presented. ON The link is active.
LINK/ACT
Blinking Data is being transmitted or received on the port.
1.3.3 Port Cable
Refer to section 1.2.3 "Port Cable” on page 1-5 for information about the port cable required by an LS81T12PE.
Installation Manual H3C S7502 Ethernet Switch Chapter 1 Product Overview
1-9
1.4 LS81T16P
Figure 1-8 Appearance of LS81T16P
1.4.1 Specifications
LS81T16P provides the XG high-speed bus an d 16 × 10/100/1000Base-T ports and 8 × 1000Base-X (SFP) ports.
Table 1-7 LS81T16P specifications
Item LS81T16P
CPU MPC8245 300 MHz BootROM 512 KB Flash memory 32 MB SDRAM 256 MB Dimensions (H × W x D) 40.1 × 376.7 × 354.5 mm (1.6 × 14.8 × 14 in.)
Port
z 16 × 10/100/1000Base-T auto-sensing
Ethernet electric ports
z 8 × 1000Base-X (SFP) Ethernet ports
Max power consumption 55 W Connector RJ45, LC Number of ports 24
Port rate
z 10 Mbps half/full duplex z 100 Mbps half/full duplex z 1000 Mbps full duplex z MDI/MDI-X auto-sensing
SFP module Refer to Table 1-4 Port cable and max transmission
distance
100 m (328 ft) over category-5 twisted pair cable
Installation Manual H3C S7502 Ethernet Switch Chapter 1 Product Overview
1-10
Item LS81T16P
Supported standard
z IEEE 802.3 z IEEE 802.3u z IEEE 802.3z z IEEE 802.3ab z IEEE 802.1p z IEEE 802.1Q z IEEE 802.1D z IEEE 802.1X z IEEE 802.1s z IEEE 802.1w z IEEE 802.3x z IEEE 802.3ad
1.4.2 Panel and LEDs
The following figure illustrates the panel of an LS81T16P.
Figure 1-9 LS81T16P panel
(1) (2)
(5)(6)(7)
(3)(4)
(1) Silkscreen (2) Nut (3) LPU edge (Green) (4) Ejector lever (5) SPF port (Gigabit) (6) Port status LED (7) Ethernet port (Gigabit)
Figure 1-10 LS81T16P panel
The status LEDs on an LS81T16P a re described in following table
Installation Manual H3C S7502 Ethernet Switch Chapter 1 Product Overview
1-11
Table 1-8 Description of LEDs on the panel of an LS81T16P
LED Status
OFF The link is down or no link is presented. ON The link is active.
LINK/ACT
Blinking Data is being transmitted or received on the port.
1.4.3 Port Cable
Refer to section 1.2.3 "Port Cable” on page 1-5 for information about the port cable required by an LS81T16P.
1.5 LS81T32P
Figure 1-11 Appearance of LS81T32P
1.5.1 Specifications
LS81T32P provides the XG high-speed bus, 32 × 10/100/1000Base-T auto-sensing Ethernet electric ports and 16 ×1000Base-X (SFP) Ethernet port s.
Table 1-9 LS81T32P specifications
Item LS81T32P
CPU MPC8245 300 MHz BootROM 512 KB Flash memory 32 MB SDRAM 256 MB Dimensions (H × W x D) 40.1 × 376.7 × 354.5 mm (1.6 × 14.8 × 14 in.)
Port
z 32 × 10/100/1000Base-T auto-sensing
Ethernet electric ports
z 16 × 1000Base-X (SFP) Ethernet ports
Max power consumption 95 W Connector RJ45, LC Number of ports 48
Installation Manual H3C S7502 Ethernet Switch Chapter 1 Product Overview
1-12
Item LS81T32P
Port rate
z 10 Mbps half/full duplex z 100 Mbps half/full duplex z 1000 Mbps full duplex z MDI/MDI-X auto-sensing
SFP module Refer to Table 1-4 Port cable and max transmission
distance
100 m (328 ft) over category-5 twisted pair cable
Supported standard
z IEEE 802.3 z IEEE 802.3u z IEEE 802.3z z IEEE 802.3ab z IEEE 802.1p z IEEE 802.1Q z IEEE 802.1D z IEEE 802.1X z IEEE 802.1s z IEEE 802.1w z IEEE 802.3x z IEEE 802.3ad
1.5.2 Panel and LEDs
The following figure illustrates the panel of an LS81T32P.
Figure 1-12 LS81T32P panel
(1) (2)
(5)(6)(7)
(3)
(4)
(1) Silkscreen (2) Nut (3) LPU edge (Green) (4) Ejector lever (5) Port status LED (6) SPF port (Gigabit) (7) Ethernet port (Gigabit)
Figure 1-13 LS81T32P panel
Installation Manual H3C S7502 Ethernet Switch Chapter 1 Product Overview
1-13
The status LEDs on an LS81T32P a re described in following table.
Table 1-10 Description of LEDs on the panel of an LS81T32P
LED Status
OFF The link is down or no link is presented. ON The link is active.
LINK/ACT
Blinking Data is being transmitted or received on the port.
1.5.3 Port Cable
Refer to section 1.2.3 "Port Cable” on page 1-5 for information about the port cable required by an LS81T32P.
1.6 LS81GT48B
Figure 1-14 Appearance of LS81GT48B
1.6.1 Specifications
LS81GT48B provides the XG high-speed bus, and 48 ×10/100/1000Base-T Ethernet ports.
Table 1-11 LS81GT48B specifications
Item LS81GT48B
CPU MPC8245 300 MHz BootROM 512 KB Flash memory 32 MB SDRAM 256 MB
Dimensions (H × W x D)
40.1 × 376.7 × 354.5 mm (1.6 × 14.8 ×
14 in.) Max power consumption 85 W Connector RJ45 Number of ports 48
Installation Manual H3C S7502 Ethernet Switch Chapter 1 Product Overview
1-14
Item LS81GT48B
Port rate
z 10 Mbps half/full duplex
z 100 Mbps half/full duplex
z 1000 Mbps half/full duplex
z MDI/MDI-X auto-sensing
Port cable and max transmission distance
100 m (328 ft) over category-5 twisted
pair cable
Supported standard
z IEEE 802.3
z IEEE 802.3ab
z IEEE 802.3x
z IEEE 802.1p
z IEEE 802.1D
z IEEE 802.1Q
z IEEE 802.1X
z IEEE 802.1s
z IEEE 802.1w
1.6.2 Panel and LEDs
The following figure illustrates the panel of an LS81GT48B.
Figure 1-15 LS81GT48B panel
(1) (2)
(5)(6)
(3)
(4)
(1) Silkscreen (2) Nut (3) LPU edge (Green) (4) Ejector lever (5) Ethernet port LED (6) Ethernet port
Figure 1-16 LS81GT48B panel
Each port is with a green LED.
Installation Manual H3C S7502 Ethernet Switch Chapter 1 Product Overview
1-15
Table 1-12 Description of LEDs on the panel of an LS81GT48B
LED Status
OFF The link is down or no link is presented. ON The link is active.
LINK/ACT
Blinking Data is being transmitted or received on the port.
1.6.3 Port Cable
The port cable is category-5 twisted pair cable connect ed with RJ45 connectors, whose maximum transmission distance is 100 m.
1.7 LS81GP48
Figure 1-17 Appearance of LS81GP48
1.7.1 Specifications
LS81GP48 provides the XG high-speed bus, and 48 ×10/100/1000Base-T Ethernet ports.
Table 1-13 LS81GP48 specifications
Item LS81GP48
CPU MPC8245 300 MHz BootROM 512 KB Flash memory 32 MB SDRAM 256 MB
Dimensions (H × W x D)
40.1 × 376.7 × 354.5 mm (1.6 × 14.8 ×
14 in.) Max power consumption 75 W Connector LC Number of ports 48
Installation Manual H3C S7502 Ethernet Switch Chapter 1 Product Overview
1-16
Item LS81GP48
Port rate
z 1000 Mbps
z Full duplex
SFP module Refer to Table 1-4
Supported standard
z IEEE 802.3
z IEEE 802.3u
z IEEE 802.3z
z IEEE 802.1p
z IEEE 802.1Q
z IEEE 802.1D
z IEEE 802.3x
z IEEE 802.1X
z IEEE 802.1w
z IEEE 802.3ad
z IEEE 802.1s
1.7.2 Panel and LEDs
The following figure illustrates the panel of an LS81GP48.
Figure 1-18 LS81GP48 panel
(1) (2)
(5)(6)
(3)
(4)
(1) Silkscreen (2) Nut (3) LPU edge (Green) (4) Ejector lever (5) Ethernet port LED (6) SFP interface
Figure 1-19 LS81GP48 panel
The status LEDs on an LS81GP48 are described in following table.
Installation Manual H3C S7502 Ethernet Switch Chapter 1 Product Overview
1-17
Table 1-14 Description of LEDs on the panel of an LS81GP48
LED Status
OFF The link is down or no link is presented. ON The link is active.
LINK/ACT
Blinking Data is being transmitted or received on the port.
1.7.3 Port Cable
Refer to Table 1-4.
1.8 LS81TGX2
Figure 1-20 Appearance of LS81TGX2
1.8.1 Specifications
LS81TGX2 provides the XG high-speed bus and two full duplex 10GBase-XFP ports.
Table 1-15 LS81TGX2 specifications
Item LS81TGX2
CPU MPC8245 300 MHz BootROM 512 KB Flash memory 32 MB SDRAM 256 MB Dimensions (H × W x D) 40.1 × 376.7 × 354.5 mm (1.6 × 14.8 × 14 in.) Max power consumption 35 W Connector LC Number of ports 2
Port rate
z 10 Gbps z Full duplex
XFP module
z XFP-LX-SM1310 (single mode optical
fiber, 1310 nm, 10 km [6.2 mi] )
z XFP-SX-MM850 (multimode optical fiber,
850 nm, 300 m [984 ft] )
Installation Manual H3C S7502 Ethernet Switch Chapter 1 Product Overview
1-18
Item LS81TGX2
Supported standard
z IEEE 802.3 z IEEE 802.1p z IEEE 802.1Q z IEEE 802.1D z IEEE 802.3x z IEEE 802.3ad z IEEE 802.3ae z IEEE 802.1X z IEEE 802.1s z IEEE 802.1w
1.8.2 Panel and LEDs
The following figure illustrates the panel of an LS81TGX2.
Figure 1-21 LS81TGX2 panel
(1)
(2)
(3) (4)
(5)
(6)(7)
(8)
(1) Interface number (2) Interface status LED (LINK) (3) Interface status LED (ACT) (4) Silkscreen (5) Nut (6) LPU edge (Green) (7) Ejector lever (8) XFP module interface (10 Gigabit)
Figure 1-22 LS81TGX2 panel
The status LEDs on an LS81TGX2 are described in following table.
Installation Manual H3C S7502 Ethernet Switch Chapter 1 Product Overview
1-19
Table 1-16 Description of LEDs on the panel of an LS81TGX2
LED Status
OFF The link is down or no link is presented.
LINK
ON The link is active. OFF No data is being transmitted or received on the port
ACT
Blinking Data is being transmitted or received on the port.
1.8.3 Port Cable
Table 1-17 Description on the port cables for LS81TGX2
XFP module
Central
wavelength
Connector
Matching
cable
Maximum
transmission
distance
XFP-SX-MM850 850 nm
50 µm/125 µm multimode optical fiber cable
300 m (984 ft)
XFP-LX-SM1310 1310 nm
LC
9 µm/125 µm single mode optical fiber cable
10 km (6 mi)
1.9 LS81TGX4
Figure 1-23 Appearance of LS81TGX4
1.9.1 Specifications
LS81TGX4 provides the XG high-speed bus and four full duplex 10GBase-XFP ports.
Table 1-18 LS81TGX4 specifications
Item LS81TGX4
CPU MPC8245 300 MHz BootROM 512 KB
Installation Manual H3C S7502 Ethernet Switch Chapter 1 Product Overview
1-20
Item LS81TGX4
Flash memory 32 MB SDRAM 256 MB Dimensions (H × W x D) 40.1 × 376.7 × 354.5 mm (1.6 × 14.8 × 14 in.) Max power consumption 55 W Connector LC Number of ports 4
Port rate
z 10 Gbps z Full duplex
XFP module
z XFP-LX-SM1310 (single mode optical
fiber, 1310 nm, 10 km [6.2 mi] )
z XFP-SX-MM850 (multimode optical fiber,
850 nm, 300 m [984 ft] )
Supported standard
z IEEE 802.3 z IEEE 802.1p z IEEE 802.1Q z IEEE 802.1D z IEEE 802.3x z IEEE 802.3ad z IEEE 802.3ae z IEEE 802.1X z IEEE 802.1s z IEEE 802.1w
1.9.2 Panel and LEDs
The following figure illustrates the panel of an LS81TGX4.
Figure 1-24 LS81TGX4 panel
Installation Manual H3C S7502 Ethernet Switch Chapter 1 Product Overview
1-21
(1) (2) (3)
(4)
(7)
(5)
(6)(8)
(1) Interface number (2) Interface status LED (LINK) (3) Interface status LED (ACT) (4) Silkscreen (5) Nut (6) LPU edge (Green) (7) Ejector lever (8) XFP module interface (10 Gigabit)
Figure 1-25 LS81TGX4 panel
Refer to
Table 1-16 for the description of LEDs on an LS81TGX4.
1.9.3 Port Cable
Refer to Table 1-4.
1.10 LPUs Supported by SRPUs
I. LPUs supported by SRPUs
Table 1-19 LPUs supported by SRPUs
Item
LS81T1
2PE/
LS81P1
2TE
LS81T1
6P
LS81T3
2P
LS81G
T48B
LS81G
P48
LS81T
GX2
LS81T
GX4
LS81FT 48E
— — — — — —
LS81FT 48F
— — — — —
LS81FP 48
LS81G T8UE
LS82G T20
LS82G T20A
Installation Manual H3C S7502 Ethernet Switch Chapter 1 Product Overview
1-22
Item
LS81T1
2PE/
LS81P1
2TE
LS81T1
6P
LS81T3
2P
LS81G
T48B
LS81G
P48
LS81T
GX2
LS81T
GX4
LS81G T48
LS81G T48A
LS81G T48B
LS81T1 2P
LS81T1 2PE
LS81T1 6P
LS81T3 2P
LS81P1 2T
LS81P1 2TE
LS81G P8UB
LS82G P20
LS82G P20A
LS81G P48
LS81T GX1C
LS81T GX2
LS81T GX4
LS81V SNP
II. Introduction to LPUs
z LS81FT48E: provides forty-eight 10Base-T/100Base-TX ports.
Installation Manual H3C S7502 Ethernet Switch Chapter 1 Product Overview
1-23
z LS81FT48F: provides forty-eight 10Base-T/100Base-TX ports; supports the PoE
function.
z LS81FP48: provides forty-eight 100Base-FX (SFP) ports. z LS81GT8UE: provides eight 10/100/1000Base-T ports. z LS82GT20: provides twenty 10/100/1000Base-T ports. z LS82GT20A: provides twenty 10/100/1000Base-T ports. z LS81GT48: provides forty-eight 10/100/1000Base-T ports. z LS81GT48A: provides forty-eight 10/100/1000Base-T ports and supports PoE
function.
z LS81T12P: provides twelve 10/100/1000Base-T ports and four 1000Base-X (SFP)
ports.
z LS81P12T: provides four 10/100/1000Base-T ports and twelve 1000Base-X (SF P)
ports.
z LS81GB8UA: provides eight 1000Base-X (SFP) ports. z LS82GP20: provides twenty 1000Base-X (SFP) ports. z LS82GP20A: provides twenty 1000Base-X (SFP) ports. z LS81TGX1C: provides one 10GBase-R-XENPAK port. z LS81VSNP: provides no service port, supports the XG high-speed bus, features
high performance network processor (NP) and CPU, and assists other LPUs to provide functions of policy-based routing, network address translation (NAT), and Netstream.
1.11 Physical Description of the S7502
1.11.1 Chassis and Slots
I. Front view
The S7502 chassis uses an XG high-speed bus and XGbus is silkscreened on the chassis.
Power supply module slots, RESET button, COM port (for PoE management), console port, 10Base-T/100Base-TX management port and its status LED, fan LED, and card status LED are in sequence arranged on the front panel.
The S7502 chassis provides two horizontal slots. An SRPU is required in slot 0 and does not support active-standby switchover), while an LPU is optional in slot 1..
Figure 1-26 illustrates the front view of an S7502, where an LS81TGX2 is inserted in slot 0 and slot 1, respectively. The LS81TGX2 in slot 0 serves as an SRPU, while the LS81TGX2 in slot 1 serves as an LPU.
Installation Manual H3C S7502 Ethernet Switch Chapter 1 Product Overview
1-24
(1) Power module (2) RESET button (3) COM port (4) Console port (5) Ethernet port for management and upgrade
(6) LED of Ethernet port for management and
upgrade (7) Fan LED (8) Card status LED (9) Fan tray (10) LPU (11) SRPU
Figure 1-26 Panel of an S7502 switch (an AC chassis in an example)
z Power modules
The power modules, in 1+1 redundancy backup, are at the top left corner of the cha ssis to provide AC power supply. There are LED, power switch and power input socket on a power supply module (refer to
Figure 1-31 for more information).
z RESET button
You can reset the system with the RESET button. COM port
Table 1-20 COM port attributes
Item Description
Connector RJ45 Number of connector 1 Supported standard Asynchronous EIA/TIA-232 Baudrate
115,200 bps (defaults to 9,600 bps) Transmission distance
15 m (49.2 ft)
Function
For monitoring external PoE power
supply when connected to it