No part of this manual may be reproduced or transmitted in any form or by any means
without prior written consent of Hangzhou H3C Technologies Co., Ltd.
Trademarks
H3C, , Aolynk, , H3Care,
Neocean, NeoVTL, SecPro, SecPoint, SecEngine, SecPath, Comware, Secware,
Storware, NQA, VVG, V
HUASAN are trademarks of Hangzhou H3C Technologies Co., Ltd.
All other trademarks that may be mentioned in this manual are the property of their
respective owners.
Notice
The information in this document is subject to change without notice. Every effort has
been made in the preparation of this document to ensure accuracy of the contents, but
all statements, information, and recommendations in this document do not constitute
the warranty of any kind, express or implied.
To obtain the latest information, please access:
http://www. h3c.com
Technical Support
customer_service@h3c.com
http://www. h3c.com
, TOP G, , IRF, NetPilot,
2
G, VnG, PSPT, XGbus, N-Bus, TiGem, InnoVision and
About This Manual
Related Documentation
In addition to this manual, each H3C S7502 Ethernet Switch documentation set
includes the following:
Manual Description
Organization
H3C S7502 Ethernet Switch Installation Manual is organized as follows:
H3C S7500 Series Ethernet Switches
Operation Manual
H3C S7500 Series Ethernet Switches
Command Manual
Chapter Contents
1 Product Overview
2 Line Processing Units
3 Installation Preparations
4 Hardware Installation
Guides the user to configure the
features supported by the S7500 series.
Elaborates on the commands for
configuring the S7500 series.
Introduces the characteristics of the
H3C S7502 Ethernet switch.
Introduces LPUs of the H3C S7502
Ethernet switch.
Introduces the preparations and
precautions for the H3C S7502 Ethernet
switch installation.
Introduces the integrated equipment
installation and cable connection
(including connection of grounding
cables, power cables, and interface
cables, recommended cabling, and
cable binding) of the H3C S7502
Ethernet switch.
5 System Commissioning
6 Hardware Maintenance
7. Software Maintenance
Introduces the initial power-on startup
process of the H3C S7502 Ethernet
switch.
Introduces the removal and installation
of power modules, LPUs, fan tray, and
delivered cable management brackets
of the H3C S7502 Ethernet switch.
Introduces how to load and upgrade
software of the H3C S7502 Ethernet
switch.
Chapter Contents
8. Troubleshooting
Introduces how to troubleshoot the
configuration system, power system,
fans, and LPUs of the H3C S7502
Ethernet Switch.
Conventions
The manual uses the following conventions:
I. GUI conventions
Appendix A Lightning Protection
Appendix B AC Power Cables Used in
Different Countries
Convention Description
< >
[ ]
/
Button names are inside angle brackets. For example, click
<OK>.
Window names, menu items, data table and field names
are inside square brackets. For example, pop up the [New
User] window.
Multi-level menus are separated by forward slashes. For
example, [File/Create/Folder].
Introduces lightning protection of the
H3C S7502 Ethernet switch.
Introduces the AC power cables used in
different countries, including 10A AC
power cables and 16A AC power cables.
II. Symbols
Convention Description
Warning
Caution
Note Means a complementary description.
Environmental Protection
This product has been designed to comply with the requirements on environmental
protection. For the proper storage, use and disposal of this product, national laws and
regulations must be observed.
Means reader be extremely careful. Improper operation
may cause bodily injury.
Means reader be careful. Improper operation may cause
data loss or damage to equipment.
Installation Manual
H3C S7502 Ethernet Switch Table of Contents
H3C S7500 Series Ethernet Switches are modular, large-capacity Layer 2/3 Ethernet
switches that support wire-speed forwarding. The S7500 series include S7502, S7503,
S7506, and S7506R.
zThe S7503, S7506, and S7506R are designed to operate at the convergence laye r
of IP metropolitan area networks (MANs) and at the core layer of small to
medium-sized enterprise networks and campus area networks.
zThe S7502 is designed to operate at the core layer of small to medium-sized
enterprise networks and at the convergence layer and access layer of IP MANs.
The S7502 is a high-capacity, cost-effective Layer 3 Ethernet switch. It provides
high-density GE/FE ports, as well as modularized components that enable you to
configure flexibly according to your specific needs.
Figure 1-1 S7502 in a MAN
The S7502 supports 1+1 AC power redundancy backup, and provides one switching
and routing processing unit (SRPU) slot and one line processing unit (LPU) slot. Both
the SRPU and the LPU can provide high-density service ports.
Switching engine (also known as SRPU) is the core of the S7502. Currently, switching
engines include the following models:
zLS81P12TE: provides four 10/100/1000Base-T ports and twelve 1000Base-X
(SFP) ports.
zLS81T12PE: provides twelve 10/100/1000Base-T ports and four 1000Base-X
(SFP) ports.
zLS81T16P: provides sixteen 10/100/1000Base-T ports and eight 1000Base-X
(SFP) ports, and supports XG high-speed bus.
zLS81T32P: provides thirty-two 10/100/1000Base-T ports and sixteen 1000Base-X
(SFP) ports, and supports XG high-speed bus.
zLS81GT48B: provides forty-eight 10/100/1000Base-T ports, and supports XG
high-speed bus.
zLS81GP48: provides forty-eight 1000Base-X (SFP) ports, and supports XG
high-speed bus.
z LS81TGX2: provides two 10GBase-XFP ports, and supports XG high-speed bus.
z LS81TGX4: provides four 10GBase-XFP ports and supports XG high-speed bus.
Note:
You can insert an SRPU into the second slot (slot 1) of the S7502 to serve as an LPU.
Generally an SRPU can provide these functions:
z L2/L3 data forwarding between LPUs
z Route calculation
z LPU monitoring
z Processing of the monitoring signals on the power system and fans
1.1.3 SRPU Specifications
The following table lists the SRPU specifications.
Table 1-1 SRPU specifications
Item
Switching
capacity
Packet
forwarding
rate
Number
of VLANs
MAC
address
table
Routing
table
LS81T12PE 48 Gbps 36 Mpps 4 K 16 K 64 K
LS81P12TE 48 Gbps 36 Mpps 4 K 16 K 64 K
LS81T16P 144 Gbps 108 Mpps 4 K 16 K 64 K
LS81T32P 192 Gbps 144 Mpps 4 K 16 K 64 K
LS81GT48B 192 Gbps 144 Mpps 4 K 16 K 64 K
LS81GP48 192 Gbps 144 Mpps 4 K 16 K 64 K
LS81TGX2 144 Gbps 108 Mpps 4 K 16 K 64 K
LS81TGX4 192 Gbps 144 Mpps 4 K 16 K 64 K
1.2 LS81P12TE
Figure 1-2 Appearance of an LS81P12TE
1.2.1 Specifications
Table 1-2 LS81P12TE specifications
CPU MPC8245 300 MHz
Boot ROM 512 KB
Flash memory 32 MB
SDRAM 256 MB
Dimensions (H × W x D)
Port
Max power consumption 40 W
Port rate
Item LS81P12TE
40.1 × 376.7 × 354.5 mm (1.6 × 14.8 × 14 in.)
z 4 × 10/100/1000Base-T Ethernet ports
z 12 × 1000Base-X (SFP) Ethernet ports
z 1000 Mbps full duplex (optical port)
z 10 Mbps half/full duplex (electrical port)
z 100 Mbps half/full duplex (electrical port)
z 1000 Mbps full duplex (electrical port)
z IEEE 802.3
z IEEE 802.3u
z IEEE 802.3z
z IEEE 802.3ab
z IEEE 802.1p
z IEEE 802.1Q
z IEEE 802.1D
z IEEE802.1X
z IEEE802.1s
z IEEE802.1w
z IEEE 802.3x
z IEEE 802.3ad
Note:
In this manual, card dimensions refer to those of a card with ejector levers.
1.2.2 Panel and LEDs
LS81P12TE has four 10/100/1000Base-T ports and twelve 1000Base-X (SFP) ports;
each has a status LED with it.
Figure 1-3 LS81P12TE panel
(1) Interface number (2) Silkscreen
(3) Nut (4) LPU edge (Green)
(5) Ejector lever (6) Interface status indicator
(7) SPF port (Gigabit) (8) Ethernet port (Gigabit)
CPU MPC8245 300 MHz
Boot ROM 512 KB
Flash memory 32 MB
SDRAM 256 MB
Dimensions (H × W x D)
Port
40.1 × 376.7 × 354.5 mm (1.6 × 14.8 × 14 in.)
z 12 × 10/100/1000Base-T Ethernet ports
z Four 1000Base-X (SFP) Ethernet ports
Max power consumption 45 W
Connector RJ-45, LC
Number of ports 16
z1000 Mbps full duplex (optical port)
Port rate
z 10 Mbps half/full duplex (electric port)
z 100 Mbps half/full duplex (electric port)
z 1000 Mbps full duplex (electric port)
SFP module Refer to Table 1-4
Port cable and max transmission
distance
Supported standard
100 m (328 ft) over category-5 twisted pair
cable
z IEEE 802.3
z IEEE 802.3u
z IEEE 802.3z
z IEEE 802.3ab
z IEEE 802.1p
z IEEE 802.1Q
z IEEE 802.1D
z IEEE802.1X
z IEEE802.1s
z IEEE802.1w
z IEEE 802.3x
z IEEE 802.3ad
1.3.2 Panel and LEDs
LS81T12PE has 12 × 10/100/1000Base-T ports and four 1000Base-X (SFP) ports;
each has a status LED with it.
(1) Interface number (2) Silkscreen
(3) Nut (4) LPU edge (Green)
(5) Ejector lever (6) SPF port (Gigabit)
(7) Interface status LED (8) Ethernet port (Gigabit)
(5)(6)(7)
Figure 1-7 LS81T12PE panel
The status LEDs on an LS81T12PE are described in
Table 1-6.
Table 1-6 Description of LEDs on the panel of an LS81T12PE
(4)
(3)
LED Status
LINK/ACT
1.3.3 Port Cable
Refer to section 1.2.3 "Port Cable” on page 1-5 for information about the port cable
required by an LS81T12PE.
OFF The link is down or no link is presented.
ON The link is active.
Blinking Data is being transmitted or received on the port.
z 100 Mbps half/full duplex
z 1000 Mbps full duplex
z MDI/MDI-X auto-sensing
SFP module Refer to Table 1-4
Port cable and max transmission
distance
Supported standard
1.5.2 Panel and LEDs
The following figure illustrates the panel of an LS81T32P.
100 m (328 ft) over category-5 twisted pair
cable
z IEEE 802.3
z IEEE 802.3u
z IEEE 802.3z
z IEEE 802.3ab
z IEEE 802.1p
z IEEE 802.1Q
z IEEE 802.1D
z IEEE 802.1X
z IEEE 802.1s
z IEEE 802.1w
z IEEE 802.3x
z IEEE 802.3ad
Figure 1-12 LS81T32P panel
(1)(2)
(5)(6)(7)
(4)
(3)
(1) Silkscreen (2) Nut
(3) LPU edge (Green) (4) Ejector lever
(5) Port status LED (6) SPF port (Gigabit)
(7) Ethernet port (Gigabit)
The following figure illustrates the panel of an LS81GP48.
z 1000 Mbps
z Full duplex
z IEEE 802.3
z IEEE 802.3u
z IEEE 802.3z
z IEEE 802.1p
z IEEE 802.1Q
z IEEE 802.1D
z IEEE 802.3x
z IEEE 802.1X
z IEEE 802.1w
z IEEE 802.3ad
z IEEE 802.1s
Figure 1-18 LS81GP48 panel
(1)(2)
(5)(6)
(4)
(3)
(1) Silkscreen (2) Nut
(3) LPU edge (Green) (4) Ejector lever
(5) Ethernet port LED (6) SFP interface
Figure 1-19 LS81GP48 panel
The status LEDs on an LS81GP48 are described in following table.
Table 1-14 Description of LEDs on the panel of an LS81GP48
LED Status
OFF The link is down or no link is presented.
LINK/ACT
1.7.3 Port Cable
Refer to Table 1-4.
1.8 LS81TGX2
Figure 1-20 Appearance of LS81TGX2
1.8.1 Specifications
ON The link is active.
Blinking Data is being transmitted or received on the port.
LS81TGX2 provides the XG high-speed bus and two full duplex 10GBase-XFP ports.
Table 1-15 LS81TGX2 specifications
Item LS81TGX2
CPU MPC8245 300 MHz
BootROM 512 KB
Flash memory 32 MB
SDRAM 256 MB
Dimensions (H × W x D) 40.1 × 376.7 × 354.5 mm (1.6 × 14.8 × 14 in.)
Max power consumption 35 W
Connector LC
Number of ports 2
z IEEE 802.3
z IEEE 802.1p
z IEEE 802.1Q
z IEEE 802.1D
Supported standard
z IEEE 802.3x
z IEEE 802.3ad
z IEEE 802.3ae
z IEEE 802.1X
z IEEE 802.1s
z IEEE 802.1w
1.8.2 Panel and LEDs
The following figure illustrates the panel of an LS81TGX2.
Figure 1-21 LS81TGX2 panel
(1)
(3)(4)
(2)
(8)
(1) Interface number (2) Interface status LED (LINK)
(3) Interface status LED (ACT) (4) Silkscreen
(5) Nut (6) LPU edge (Green)
(7) Ejector lever (8) XFP module interface (10 Gigabit)
(5)
(6)(7)
Figure 1-22 LS81TGX2 panel
The status LEDs on an LS81TGX2 are described in following table.
Table 1-16 Description of LEDs on the panel of an LS81TGX2
LED Status
LINK
ACT
1.8.3 Port Cable
Table 1-17 Description on the port cables for LS81TGX2
XFP module
XFP-SX-MM850 850 nm
XFP-LX-SM1310 1310 nm
OFF The link is down or no link is presented.
ON The link is active.
OFF No data is being transmitted or received on the port
Blinking Data is being transmitted or received on the port.
Central
wavelength
Connector
LC
Matching
cable
50 µm/125 µm
multimode
optical fiber
cable
9 µm/125 µm
single mode
optical fiber
cable
Maximum
transmission
300 m (984 ft)
10 km (6 mi)
distance
1.9 LS81TGX4
Figure 1-23 Appearance of LS81TGX4
1.9.1 Specifications
LS81TGX4 provides the XG high-speed bus and four full duplex 10GBase-XFP ports.
Table 1-18 LS81TGX4 specifications
Flash memory 32 MB
SDRAM 256 MB
Dimensions (H × W x D) 40.1 × 376.7 × 354.5 mm (1.6 × 14.8 × 14 in.)
Max power consumption 55 W
Connector LC
Number of ports 4
Port rate
XFP module
Supported standard
1.9.2 Panel and LEDs
The following figure illustrates the panel of an LS81TGX4.
z 10 Gbps
z Full duplex
z XFP-LX-SM1310 (single mode optical
fiber, 1310 nm, 10 km [6.2 mi] )
zXFP-SX-MM850 (multimode optical fiber,
850 nm, 300 m [984 ft] )
z IEEE 802.3
z IEEE 802.1p
z IEEE 802.1Q
z IEEE 802.1D
z IEEE 802.3x
z IEEE 802.3ad
z IEEE 802.3ae
z IEEE 802.1X
z IEEE 802.1s
z IEEE 802.1w
(1) Interface number (2) Interface status LED (LINK)
(3) Interface status LED (ACT) (4) Silkscreen
(5) Nut (6) LPU edge (Green)
(7) Ejector lever (8) XFP module interface (10 Gigabit)
Figure 1-25 LS81TGX4 panel
Refer to
1.9.3 Port Cable
(1)(2) (3)
(7)
(4)
Table 1-16 for the description of LEDs on an LS81TGX4.
zLS81FT48F: provides forty-eight 10Base-T/100Base-TX ports; supports the PoE
function.
z LS81FP48: provides forty-eight 100Base-FX (SFP) ports.
z LS81GT8UE: provides eight 10/100/1000Base-T ports.
z LS82GT20: provides twenty 10/100/1000Base-T ports.
z LS82GT20A: provides twenty 10/100/1000Base-T ports.
z LS81GT48: provides forty-eight 10/100/1000Base-T ports.
z LS81GT48A: provides forty-eight 10/100/1000Base-T ports and supports PoE
function.
zLS81T12P: provides twelve 10/100/1000Base-T ports and four 1000Base-X (SFP)
ports.
zLS81P12T: provides four 10/100/1000Base-T ports and twelve 1000Base-X (SF P)
ports.
z LS81GB8UA: provides eight 1000Base-X (SFP) ports.
z LS82GP20: provides twenty 1000Base-X (SFP) ports.
z LS82GP20A: provides twenty 1000Base-X (SFP) ports.
z LS81TGX1C: provides one 10GBase-R-XENPAK port.
z LS81VSNP: provides no service port, supports the XG high-speed bus, features
high performance network processor (NP) and CPU, and assists other LPUs to
provide functions of policy-based routing, network address translation (NAT), and
Netstream.
1.11 Physical Description of the S7502
1.11.1 Chassis and Slots
I. Front view
The S7502 chassis uses an XG high-speed bus and XGbus is silkscreened on the
chassis.
Power supply module slots, RESET button, COM port (for PoE management), console
port, 10Base-T/100Base-TX management port and its status LED, fan LED, and card
status LED are in sequence arranged on the front panel.
The S7502 chassis provides two horizontal slots. An SRPU is required in slot 0 and
does not support active-standby switchover), while an LPU is optional in slot 1..
Figure 1-26 illustrates the front view of an S7502, where an LS81TGX2 is inserted in
slot 0 and slot 1, respectively. The LS81TGX2 in slot 0 serves as an SRPU, while the
LS81TGX2 in slot 1 serves as an LPU.
(1) Power module (2) RESET button
(3) COM port (4) Console port
(5) Ethernet port for management and
upgrade
(7) Fan LED (8) Card status LED
(9) Fan tray (10) LPU
(11) SRPU
(6) LED of Ethernet port for management and
upgrade
Figure 1-26 Panel of an S7502 switch (an AC chassis in an example)
zPower modules
The power modules, in 1+1 redundancy backup, ar e at the top left corner of the chassis
to provide AC power supply. There are LED, power switch and power input socket on a
power supply module (refer to
zRESET button
Figure 1-31 for more information).
You can reset the system with the RESET button.
COM port
Table 1-20 COM port attributes
Item Description
Connector RJ45
Number of connector 1
Supported standard Asynchronous EIA/TIA-232
Baudrate
Transmission distance
Function
≤ 115,200 bps (defaults to 9,600 bps)
≤ 15 m (49.2 ft)
For monitoring external PoE power
supply when connected to it
1-24
Loading...
+ 114 hidden pages
You need points to download manuals.
1 point = 1 manual.
You can buy points or you can get point for every manual you upload.