Introduction
To enjoy your new battery charger as long as possible, please read carefully the Operating Instructions and the enclosed safety instructions before putting it into operation. Further, it is recommended to keep this manual for future reference – when features of this product are required to be recalled. Because of the continuous development of our products, we reserve the right to make technical changes.
This document represents the original Operating Instructions.
Appliance description
The automatic battery charger is controlled by a micro processor and as a consequence, charging takes place in three levels. At the first level, the battery is charged by almost constant current to approximately 85%. At the second level, the battery is charged to approximately 95% at constant voltage. The third level keeps constant voltage of the battery, i.e. the battery is constantly charged to the full extent.
GAB 15A (pic. A)
1. Carrying handle
2. Operating panel
3. Charging pliers, black (-)
4. Charging pliers, red (+)
5. 12V DC outlet
GAB 8A (pic. A)
1. Carrying handle
2. Operating panel
3. Charging pliers, black (-)
4. Charging pliers, red (+)
5. Power cord
GAB 15A operating elements (pic. B)
1. Voltage indication LED
(LED is on when the appliance is in the standby mode or if the 2/8/10/15A button has been pressed)
2. 2/8/10/15A charging current setting button (One second after pressing, the appliance starts
to be charged by appropriate charging current with the existing value being shown on the display)
3. ON/OFF button
(Keep the button pressed for at least 1 second – this will switch the appliance on and “000“ will be blinking on the display – now you are in the standby mode)
4. 12V DC outlet button
ON/OFF with signalling by LED
(Pressing the button in the standby mode activates the 12V DC outlet on the back of the appliance. If the button is pressed again, the charger gets back to the standby mode).
5. Button for current battery voltage
(After pressing the button, the appliance shows the current battery voltage for 3 seconds in the standby mode and during the charging process.)
6. "Battery fully charged" LED
7. "Battery charging" LED
8. "Failure" LED
9. Three-digit LED display
(see the table for description)
10. LED signalling current
(this LED is on during the charging process or when the 12V DC outlet is active)
11. LED for WET type battery
12. LED for AGM type battery
13. LED for GEL type battery
LED display Description Failure removal
Standby mode
Check the battery
Battery voltage is shown during the charging process or in the standby mode, e.g. 13.8 V
1. Charging current is shown (e.g. 5.8 A );
2. Extraction flow at 12V DC outlet is shown.
1. Battery pole not connected
2. Short circuit
1. Connect the battery pole.
2. Faulty battery Exchange of connections (reversal of polarity)
Switch the appliance off and disconnect the plug from the outlet and connect correctly
1. Battery is significantly discharged
2. Faulty battery cell
3. 3.6 V battery is connected
Switch off and disconnect from the electric power supply and remove the battery (faulty)
1. Battery cell short circuit
2. Inappropriate charging current has been selected
Try another charging current, if the failure persists, the battery is probably
faulty Battery terminal has got released, the appliance is switching off and activating the warning signal
Check the
connection and
select the
charging current
again
Battery is fully charged, battery voltage remains constant, battery remains charged.