GYS L180/D80, L180/D120 User guide [uk]

Inductance-loop usage guidelines
Ideal Not recommended
d
D
D > 60 = D - 5 mm < d < (0,8 x D) D < 60 = D - 2 mm < d < (0,8 x D)
A gap must be le between the loop and the heated part in order to limit the risk of heang the surface treatment or trapping the part in the loop when the part expands.
d
d < (0,8 x D)
If the inductance loop’s diameter is too small, the aachment’s heang capacity will be less ecient. This item is not able to transmit power to component parts.
Not recommended
If the part being heated is not centred in the loop, the heang will not be even. The side of the component part closest to the inductor will heat up more.
Not recommended Not recommended
Risk of sparks, splaer and/or damage if
the and/or damage if the part touches the
inductance loop’s base.
Do not heat when empty,
without a workpiece to heat.
See next page to limit deterioraon.
Base
Recommended use for opmised heang
D < 60 mm
Ø of the inductance
loop (D) in mm
20 18 < d < 16
25 23 < d < 20 70 65 < d < 56
30 28 < d < 24 80 75 < d < 64
35 33 < d < 28 90 85 < d < 72
40 38 < d < 32 100 95 < d < 80
45 43 < d < 36 110 105 < d < 88
50 48 < d < 40 120 115 < d < 96
55 53 < d < 44
Ø of the part
(d) in mm
Ø of the inductance
loop (D) in mm
60 55 < d < 48
D > 60 mm
Ø of the part
(d) in mm
V2_10/02/2022
Limit the risk of damage when used manually
To limit the risk of short-circuing the loop, it is possible to add a protecve glass cloth.
Use :
• Put dots of glue on the canvas and posion it as shown in the photos.
• Use a collar to hold the fabric while the glue sets.
• Wait 24 hours.
Materials needed:
Kit 053854
5 protecons for glass inductor + glue
Laying for large S loops
Laying for small S loops
GLUE SPOTS
Laying for small L loops
Kit 053847
10 protecons inducer release + glue
Laying for large L loops
Another way to protect a loop is to increase the thickness of the protecve epoxy resin.
Materials needed:
054851
Bi-component Power Epoxy glue 50ml
Use :
• Clean the loop
• Scrub with a scotch-brite
• Remove the glue
• Wait 24 hours.
Loading...