Introduction
The Probe is a clamp-on AC/DC current probe for use with common digital
multimeters and labscopes. It has been designed and tested according to IEC
Publication 1010-2-032 (1994, 12) (Overvoltage Category III), Safety Requirements
for Hand-help Current Clamps for Electrical Measurement and Test, the EMC
Directive (EN 50081-1 and EN 50082-1). Designed to Protection Class II, Double
or reinforced insulation requirements of UL 3111, CAN/CSA C22.2 No. 1010.192, ISA-DC82, and IEC 1010-2-032.
Specifications
Current Ranges: 0-1 to 400A AC/DC and 1A to 1000A dc/ac
Output Signals: 1mV per Amp AC/DC in the 400 Amp range
0.1mV per Amp AC/DC in the 1000 Amp range
Accuracy: (DC to 400Hz) ± (2% of reading + 5)
Working V oltage: 600V AC/DC rms
Common Mode V oltage: 42V DC or 30V AC
Storage T emperature: -20°C to 60°C (-4°F to 140°F)
Operating T emperature: 0°C to 45°C (32°F to 95°F)
Relative Humidity: 0% to 80% (0°C to 35°C; 32°F to 113°F)
0% to 70% (35°C to 45°C; 95°F to 113°F)
Battery T ype: 9V, NEDA 1604 or IEC 6LR61
Battery Life: 200 Hours typical (alkaline)
Max. Conductor Size: 1 Conductor 51mm (2.00 inch)
2 Conductor 25mm (.98 inch)
Maximum Jaw Opening: 52mm (2.04 inc.)
Output Cable: 1.6 meters (63 inches)
Dimensions: 205 x 97 x 44mm (8.07 x 3,82 x 1.73 in.)
Weight: 410g (14.5 oz.)
Compatibility
The Probe is compatible with any 4000 count millivolt measuring device that has
the following features:
• Range and resolution capable of displaying millivolts with a 1 millivolt resolution
for the 400 Amp range, and a resolution of 0.1 Millivolt for the 1000 Amp
range.
• Accepts standard safety-shrouded plugs or a banana plug.
• Input impedance of greater than or equal to 10MΩ