GW Instek AFG-2000 Series QUICK START GUIDE

Arbitrary Function Generator
AFG-2000 Series
USER MANUAL
GW INSTEK PART NO. 82AF-21200EC1
ISO-9001 CERTIFIED MANUFACTURER
This manual contains proprietary information, which is protected by copyright. All rights are reserved. No part of this manual may be photocopied, reproduced or translated to another language without prior written consent of Good Will Corporation.
The information in this manual was correct at the time of printing. However, Good Will continues to improve its products and therefore reserves the right to change the specifications, equipment, and maintenance procedures at any time without notice.
Good Will Instrument Co., Ltd. No. 7-1, Jhongsing Rd., Tucheng Dist., New Taipei City 236, Taiwan.
TABLE OF CONTENTS

Table of Contents

SAFETY INSTRUCTIONS .................................. 3
GETTING STARTED ......................................... 8
Main Features ..................................................................... 8
Panel Overview .................................................................. 10
Setting up the Function Generator .................................... 16
QUICK REFERENCE ....................................... 18
How to use the Digital Inputs ........................................... 19
Selecting a Waveform ........................................................ 21
ARB ................................................................................... 23
Modulation ........................................................................ 24
Sweep (2100 series only) ................................................... 28
Counter (2100 series only) ................................................ 30
Save/Recall ........................................................................ 31
Default Settings ................................................................ 32
OPERATION .................................................. 34
Select a Waveform ............................................................. 36
Setting the Frequency ........................................................ 36
Setting the Amplitude........................................................ 37
Setting the DC Offset ........................................................ 38
Setting the Duty Cycle/Symmetr y ...................................... 39
Setting the Output Impedance .......................................... 41
Turning the Output On ...................................................... 42
Amplitude Modulation (AM) (AFG-2100 Series) ............... 43
Frequency Modulation (FM) (AFG-2100 Series) ................. 51
Frequency Shift Keying (FSK) Modulation (AFG-2100 Series)
.......................................................................................... 59
Frequency Sweep (AFG-2100 Series) .................................. 67
Creating an Arbitrary Waveform ......................................... 73
1
AFG-2000 Series User Manual
Using the Frequency Counter ............................................. 75
Using the SYNC Output Port ............................................. 77
Save and Recall State/ARB Waveform ................................ 81
REMOTE INTERFACE ..................................... 83
Selecting the USB Remote Interface .................................. 85
Command Syntax ............................................................... 86
Command List ................................................................... 92
System Commands ............................................................ 94
Status Register Commands ................................................ 95
Apply Commands .............................................................. 96
Output Commands .......................................................... 102
Amplitude Modulation (AM) Commands ......................... 110
AM Overview ................................................................... 110
Frequency Modulation (FM) Commands .......................... 114
FM Overview ................................................................... 114
Frequency-Shift Keying (FSK) Commands ........................ 119
FSK Overview .................................................................. 119
Frequency Sweep Commands........................................... 123
Sweep Overview .............................................................. 123
Frequency Counter Commands ........................................ 128
Arbitrary Waveform Commands ....................................... 130
Arbitrary Waveform Overview .......................................... 130
Save and Recall Commands ............................................. 133
APPENDIX ................................................... 135
Error Messages ............................................................... 135
AFG-2000 Series Specifications ....................................... 137
EC Declaration of Conformity .......................................... 141
INDEX ......................................................... 142
2
SAFETY INSTRUCTIONS
WARNING
Warning: Identifies conditions or practices that could result in injury or loss of life.
CAUTION
Caution: Identifies conditions or practices that could result in damage to the function generator or to other objects or property.
DANGER High Voltage
Attention: Refer to the Manual
Protective Conductor Terminal
Earth (Ground) Terminal
DANGER Hot Surface

SAFETY INSTRUCTIONS

This chapter contains important safety instructions that should be followed when operating and storing the function generator. Read the following before any operation to ensure your safety and to keep the function generator in the best condition.

Safety Symbols

These safety symbols may appear in this manual or on the instrument.
3
AFG-2000 Series User Manual
Double Insulated
Do not dispose electronic equipment as unsorted municipal waste. Please use a separate collection facility or contact the supplier from which this instrument was purchased.
General Guideline
CAUTION
Do not place heavy objects on the instrument. Do not place flammable objects on the
instrument.
Avoid severe impact or rough handling that
may damage the function generator.
Avoid discharges of static electricity on or near
the function generator.
Use only mating connectors, not bare wires, for
the terminals.
The instrument should only be disassembled by
a qualified technician.
(Measurement categories) EN 61010-1:2010 specifies the measurement categories and their requirements as follows. The instrument falls under category II.
Measurement category IV is for measurement performed at the
source of a low-voltage installation.
Measurement category III is for measurement performed in a
building installation.
Measurement category II is for measurement performed on
circuits directly connected to a low voltage installation.
Measurement category I is for measurements performed on
circuits not directly connected to Mains.
Power Supply
WARNING
AC Input voltage: 100 ~ 240V AC, 50 ~ 60Hz. Connect the protective grounding conductor of
the AC power cord to an earth ground to prevent electric shock.

Safety Guidelines

4
SAFETY INSTRUCTIONS
Fuse
WARNING
Fuse type: F1A/250V. Only qualified technicians should replace the
fuse.
To ensure fire protection, replace the fuse only
with the specified type and rating.
Disconnect the power cord and all test leads
before replacing the fuse.
Make sure the cause of fuse blowout is fixed
before replacing the fuse.
Cleaning the function generator
Disconnect the power cord before cleaning the
function generator.
Use a soft cloth dampened in a solution of mild
detergent and water. Do not spray any liquid into the function generator.
Do not use chemicals containing harsh products
such as benzene, toluene, xylene, and acetone.
Operation Environment
Location: Indoor, no direct sunlight, dust free,
almost non-conductive pollution (Note below) and avoid strong magnetic fields.
Relative Humidity: < 80% Altitude: < 2000m Temperature: 0°C to 40°C
(Pollution Degree) EN 61010-1:2010 specifies pollution degrees and their requirements as follows. The function generator falls under degree 2.
Pollution refers to “addition of foreign matter, solid, liquid, or
gaseous (ionized gases), that may produce a reduction of dielectric strength or surface resistivity”.
Pollution degree 1: No pollution or only dry, non-conductive
pollution occurs. The pollution has no influence.
Pollution degree 2: Normally only non-conductive pollution
occurs. Occasionally, however, a temporary conductivity caused by condensation must be expected.
Pollution degree 3: Conductive pollution occurs, or dry, non-
conductive pollution occurs which becomes conductive due to condensation which is expected. In such conditions, equipment is normally protected against exposure to direct sunlight,
5
AFG-2000 Series User Manual
precipitation, and full wind pressure, but neither temperature nor humidity is controlled.
Storage environment
Location: Indoor Relative Humidity: < 70% Temperature: -10°C to 70°C
Disposal
Do not dispose this instrument as unsorted municipal waste. Please use a separate collection facility or contact the supplier from which this instrument was purchased. Please make sure discarded electrical waste is properly recycled to reduce environmental impact.
6
SAFETY INSTRUCTIONS
Green/ Yellow:
Earth
Blue:
Neutral
Brown:
Live (Phase)

Power cord for the United Kingdom

When using the function generator in the United Kingdom, make sure the power cord meets the following safety instructions.

NOTE: This lead/appliance must only be wired by competent persons

WARNING: THIS APPLIANCE MUST BE EARTHED IMPORTANT: The wires in this lead are coloured in accordance with the following code:
As the colours of the wires in main leads may not correspond with the coloured marking identified in your plug/appliance, proceed as follows:
The wire which is coloured Green & Yellow must be connected to the Earth terminal marked with either the letter E, the earth symbol or coloured
Green/Green & Yellow.
The wire which is coloured Blue must be connected to the terminal which is marked with the letter N or coloured Blue or Black.
The wire which is coloured Brown must be connected to the terminal marked with the letter L or P or coloured Brown or Red.
If in doubt, consult the instructions provided with the equipment or contact the supplier.
This cable/appliance should be protected by a suitably rated and approved HBC mains fuse: refer to the rating information on the equipment and/or user instructions for details. As a guide, a cable of 0.75mm2 should be protected by a 3A or 5A fuse. Larger conductors would normally require 13A types, depending on the connection method used.
Any exposed wiring from a cable, plug or connection that is engaged in a live socket is extremely hazardous. If a cable or plug is deemed hazardous, turn off the mains power and remove the cable, any fuses and fuse assemblies. All hazardous wiring must be immediately destroyed and replaced in accordance to the above standard.
7
AFG-2000 Series User Manual
Model name
AFG-2005
AFG-2105
AFG-2012
AFG-2112
AFG-2025
AFG-2125
Frequency Range
0.1Hz~5MHz
0.1Hz~12MHz
0.1Hz~25MHz
Output waveform
Sine, Square, Ramp, Noise, ARB
Amplitude range
0.1Hz~20MHz
1 mVpp to 10 Vpp (into 50Ω)
2 mVpp to 20 Vpp (open-circuit)
20MHzHz~25MHz
1 mVpp to 5 Vpp (into 50Ω)
2 mVpp to 10 Vpp (open-circuit)
Variable Offset
    
Variable Duty
    
SYNC (TTL) output
    
Save/Recall
    
Sweep operation
AM
FM
FSK
Frequency Counter

GETTING STARTED

The Getting started chapter introduces the
function generator’s main features, appearance
and introduces a quick instructional summary of some of the basic functions. For comprehensive operation instructions, please see the operation chapter.

Main Features

8
GETTING STARTED
ARB
    
USB Interface
    
Performance
DDS technology using an FPGA provides high
resolution waveforms
25MHz DDS (Direct Digital Synthesis) signal
output series
0.1Hz resolution Full Function Arbitrary Waveform Capability
20 MSa/s sample rate
10 MHz repetition rate
4 k-point waveform length
10-bit amplitude resolution
Ten 4k waveform memories
Features
Sine, Square, Ramp, Noise Int/Ext AM, FM, FSK modulation Modulation/sweep signal output Save/recall 10 groups of setting memories Output overload protection ARB (Arbitrary Waveform) can be edited with
PC software
Interface
USB interface as standard 3.5 inch LCD
9
AFG-2000 Series User Manual
ARB
OUTPUT
50
W
50
W
SYNC
MAIN
OUTPUT
POWER
Save/Recall INT/EXT Hop LIN/LOG
Shape DEP/DEV Rate Start/Stop Gate
FUNC
FREQ
AMPL
OFST
DUTY
Point
Value
0
7 8 9
4 5 6
1 2 3
/
Hz/Vpp kHz/Vrms MHz/dBm % Shift
AM FM FSK Sweep Count
OUTPUT
Enter
Arbitrary Function Generator
AFG-2125
LCD Display Number
pad
Scroll Wheel
MAIN output port
ARB keys Power
button
Output control key
Enter key
Arrow keys SYNC output port
Operation keys
Function keys
High-Z/50
ARB
OUTPUT
50
W
50
W
SYNC
MAIN
OUTPUT
POWER
Save/Recall
FUNC
FREQ
AMPL
OFST
DUTY
Point
Value
0
7 8 9
4 5 6
1 2 3
/
Hz/Vpp kHz/Vrms MHz/dBm % Shift
OUTPUT
Enter
Arbitrary Function Generator
AFG-2025
LCD Display Number
pad
Scroll Wheel
MAIN output port
ARB keys Power
button
Output control key
Enter key
Arrow keys SYNC output port
Operation keys
Function keys
High-Z/50

Panel Overview

AFG-2105/2112/2125 Front Panel

AFG-2005/2012/2025 Front Panel

10
GETTING STARTED
LCD display
3.5 inch, 3 color LCD display.
Keypad
0
/
321
4
7 859
6
The digital keypad is used to enter values and parameters. The keypad is often used in conjunction with the selection keys and variable knob.
Scroll Wheel
The scroll wheel is used to edit values and parameters in steps of 1 digit. Used in conjunction with the arrow keys.
Decrease Increase
Arrow keys
Used to select digits when editing parameters.
Output ports
OUTPUT
50
W
50
W
SYNC
MAIN
OUTPUT
SYNC output port (50Ω impedance).
Main output port (50Ω
impedance).
Enter key
Enter
Used to confirm input values.
Power button
POWER
Turns the instrument power on/off.
Output control key
OUTPUT
Turns the output on/off.
Output Impedance
Shift
+
High Z/50
OUTPUT
Toggles the output impedance between 50Ω and High-Z.
Operation keys
Hz/Vpp
Selects Hz or Vpp units.
11
AFG-2000 Series User Manual
Shift
+
Save/Recall
Hz/Vpp
Saves or recalls waveforms from memory.
kHz/Vrms
Selects kHz or Vrms units.
Shift
+
INT/EXT
kHz/Vrms
Sets the source to internal or external for the modulation and FSK functions*.
MHz/dBm
Selects MHz or dBm units.
Shift
+
Hop
MHz/dBm
Sets the ―Hop‖ frequency for FSK
modulation*.
%
Selects % units.
Shift
+
LIN/LOG
%
Sets the sweep to linear or logarithmic*.
Shift
The shift key is used to select the secondary functions on the operation keys.
AM
The AM key is used to turn AM modulation on/off*.
Shift
+
Shape
AM
Selects the modulation waveform*.
FM
The FM key is used to turn FM modulation on/off*.
Shift
+
DEP/DEV
FM
Selects the modulation depth or the frequency deviation*.
FSK
Selects FSK modulation*.
Shift
+
Rate FSK
Sets the AM, FM, FSK modulation and sweep function rate*
Sweep
Selects the Sweep function*.
12
GETTING STARTED
Shift
+
Start/Stop
Sweep
Sets the Start or Stop frequency*.
Count
Turns the frequency counter on/off*.
Shift
+
Gate
Count
Sets the frequency counter gate time*.
ARB edit keys
ARB
Value
Point
Arbitrary waveform editing keys.
The Point key sets the ARB point numbers.
The Value key sets the amplitude value of the selected point.
Function keys
FUNC
The FUNC key is used to select the output waveform type:
Sine, Square, Ramp, Noise, ARB.
FREQ
Sets the frequency of the selected waveform.
AMPL
Sets the amplitude of the selected waveform.
OFST
The OFST sets the DC offset for the selected waveform.
DUTY
The DUTY key sets the duty cycle of square and ramp waveforms.
*indicates functions/features for the AFG-2105/2112/2125 only.
13
AFG-2000 Series User Manual
NO OPERATOR SERVICEABLE COMPONENTS INSIDE. DO NOT REMOVE COVERS. REFER SERVICING TO
TO AVOID ELECTRIC SHOCK THE POWER CORD PROTECTIVE GROUNDING CONDUCTOR MUST BE CONNECTED TO GROUND.
WARNING
QUALIFIED PERSONNEL.
SER.NO. LABEL
AC 100-240V 50-60Hz 25VA
OUTPUT INPUT
MOD Counter
Trigger MOD
MOD input
Trigger input
MOD output
Type B USB portPower socket
Counter input
NO OPERATOR SERVICEABLE COMPONENTS INSIDE. DO NOT REMOVE COVERS. REFER SERVICING TO
TO AVOID ELECTRIC SHOCK THE POWER CORD PROTECTIVE GROUNDING CONDUCTOR MUST BE CONNECTED TO GROUND.
WARNING
QUALIFIED PERSONNEL.
SER.NO. LABEL
AC 100-240V 50-60Hz 25VA
Type B USB portPower socket
MOD output
OUTPUT INPUT
MOD Counter
Trigger MOD
Modulation output port.
Counter input
Counter input port.
MOD input
Modulation input port.
Trigger input
Trigger input port.
Type B USB port
The type B USB port is used to connect the function generator to a PC for remote control.
Power Socket Input
AC 100-240V 50-60Hz 25VA
Power input: 100~240V AC
50~60Hz.

AFG-2105/2112/2125 Rear Panel

AFG-2005/2012/2025 Rear Panel
14

Display

Waveform type
Counter settings
USB icon
Frequency display
Secondary parameter display
Modulation, sweep, counter menu
Waveform type
Press the function key to cycle through different output waveforms.
Counter settings
Gate time counter settings*.
USB icon
Shows the USB interface status.
Frequency Display
Displays the main waveform frequency settings.
Secondary parameter display
Displays secondary waveform parameters and settings.
Modulation, sweep, counter menu
Displays the modulation, sweep and counter functions as well as the modulating waveform and source*.
*indicates functions/features for the AFG-2105/2112/2125 only.
GETTING STARTED
15
AFG-2000 Series User Manual
Background
This section describes how adjust the handle and power up the function generator.
Adjusting the stand
Pull out the handle sideways and rotate it.
ARB
OUTPUT
50W
50W
SYNC
MAIN
OUTPUT
POWER
Save/Recall INT/EXT Hop LIN/LOG
Shape DEP/DEV Rate Start/Stop Gate
FUNC
FREQ
AMPL
OFST
DUTY
Point
Value
0
7 8 9
4 5 6
1 2 3
/
Hz/Vpp kHz/Vrms MHz/dBm % Shift
AM FM FSK Sweep Count
OUTPUT
Enter
Arbitrary Function Generator
AFG-2125
Place the AFG horizontally.
Place the handle upright to tilt the stand.
Place the handle vertically to hand carry.

Setting up the Function Generator

16
GETTING STARTED
Power Up
1. Connect the power cord to
the socket on the rear panel.
2. Press the power button on
the front panel.
POWER
3. The instrument will turn on and load the
default settings (see page 32 for default settings).
The function generator is now ready to be used.
17
AFG-2000 Series User Manual
How to use the Digital Inputs ............................................ 19
Selecting a Waveform ........................................................ 21
Sine Wave ............................................................................. 21
Square Wave ........................................................................ 21
Ramp Wave .......................................................................... 22
ARB ................................................................................... 23
ARB - Points ......................................................................... 23
Modulation ........................................................................ 24
AM (2100 series only) .......................................................... 24
FM (2100 series only) .......................................................... 25
FSK Modulation (2100 series only) ..................................... 26
Sweep (2100 series only) ................................................... 28
Counter (2100 series only) ................................................ 30
Save/Recall ........................................................................ 31
Save ...................................................................................... 31
Recall .................................................................................... 31
Default Settings ................................................................. 32

QUICK REFERENCE

This chapter lists operation shortcuts and default factory settings. Use this chapter as a handy reference for instrument functions. This chapter is to be used as a quick reference; for detailed explanations on parameters, settings and limitations, please see the operation chapter (page 34) or specifications (page 137).
18
AFG-2000 Series User Manual
Background
The AFG-2000 has three main types of digital inputs: the number pad, arrow keys and the scroll wheel. The following instructions will show you how to use the digital inputs to edit parameters.
1. First select the
function that must be edited pressing one of the function or ARB keys. The selected function will flash.
ARB
OUTPUT
50
W
50
W
SYNC
MAIN
OUTPUT
POWER
Save/Recall
FUNC
FREQ
AMPL
OFST
DUTY
Point
Value
0
7 8 9
4 5 6
1 2 3
/
Hz/Vpp kHz/Vrms MHz/dBm % Shift
OUTPUT
Enter
Arbitrary Function Generator
AFG-2025
ARB keys
Function keys
2. To edit a parameter, use the
arrow keys to move the cursor to the digit that needs to be edited.
cursor

How to use the Digital Inputs

19
AFG-2000 Series User Manual
3. Use the scroll wheel to
increment the parameter by the resolution of the digit under the cursor. In the example above, the scroll wheel will increment the parameter in 0.1 volt increments. Clockwise increases the value, counterclockwise decreases the value.
4. Press the Enter key to
confirm the new parameter value.
Enter
5. Alternatively, the number
pad can be used to set the value of the selected parameter.
0
/
321
4
7 859
6
6. To finish editing with the
number pad, select the unit with one of the unit keys. (Hz, kHz, MHz, Vpp, Vrms, dBm, %)
Hz/Vpp
kHz/Vrms
MHz/dBm
%
20
QUICK REFERENCE
Example: Sine Wave, 10kHz, 1Vpp, 2Vdc
Output
50
W
MAIN
1. Press the FUNC
key repeatedly to select the Sine wave.
FUNC
2. Press FREQ > 1 > 0
> kHz.
FREQ
1
0
kHz/Vrms
3. Press AMPL > 1 >
Vpp.
AMPL
1
Hz/Vpp
4. Press OFST > 2 >
Vpp.
OFST
2
Hz/Vpp
5. Press the OUTPUT
key.
OUTPUT
Example: Square Wave, 10kHz, 3Vpp, 75% duty cycle
Output
50
W
MAIN
1. Press the FUNC
key repeatedly to select the Square wave.
FUNC
2. Press FREQ > 1 > 0
> kHz.
FREQ
1
0
kHz/Vrms

Selecting a Waveform

Sine Wave

Square Wave

21
3. Press AMPL > 3 >
Vpp.
AMPL
3
Hz/Vpp
4. Press DUTY > 7 > 5
> %.
DUTY
7
5
%
5. Press the output
key.
OUTPUT

Ramp Wave

Example: Ramp Wave, 10kHz, 3Vpp, 25% symmetry
Output
50
W
MAIN
1. Press the FUNC
key repeatedly to select the Ramp wave.
FUNC
2. Press FREQ > 1 > 0
> kHz.
FREQ
1
0
kHz/Vrms
3. Press AMPL > 3 >
Vpp.
AMPL
3
Hz/Vpp
4. Press DUTY > 2 > 5
> %.
DUTY
2
5
%
5. Press the OUTPUT
key.
OUTPUT
AFG-2000 Series User Manual
22
ARB
Example: 2 ARB points, 10 kHz, 1Vpp.
Output
50
W
MAIN
1. Press the FUNC
key repeatedly to select the ARB wave.
FUNC
2. Press FREQ > 1 > 0
> kHz.
FREQ
1
0
kHz/Vrms
3. Press AMPL > 1 >
Vpp.
AMPL
1
Hz/Vpp
4. Press Point > 0 >
Enter.
Point
0
Enter
5. Press Value > 5 > 1
>1 > Enter.
Value
511
Enter
6. Press Point > 1 >
Enter.
Point
1
Enter
7. Press Value > ± > 5
> 1 >1 > Enter.
(-511)
Value
/
511
Enter
8. Press the OUTPUT
key.
OUTPUT

ARB - Points

QUICK REFERENCE
23
AFG-2000 Series User Manual
Example: AM modulation. 100Hz modulating square wave. 1 Vpp, 1kHz Sine wave carrier. 70% modulation depth. Internal source signal.
Output
50
W
MAIN
1. Press the FUNC
key repeatedly to select the Sine wave.
FUNC
2. Press FREQ > 1 >
kHz.
FREQ
1
kHz/Vrms
3. Press AMPL > 1 >
Vpp.
AMPL
1
Hz/Vpp
4. Press AM.
AM
5. Press Shift >
INT/EXT > select INT source.
Shift
+
INT/EXT
kHz/Vrms
6. Press Shift > Shape
repeatedly to select the Square wave.
Shift
+
Shape
AM
7. Press Shift > Rate
> 1 > 0 > 0 > Hz.
Shift
+
Rate FSK
100
Hz/Vpp

Modulation

AM (2100 series only)

24
QUICK REFERENCE
8. Press Shift >
DEP/DEV> 7 > 0 > %.
Shift
+
DEP/DEV
FM
7
0
%
9. Press the OUTPUT
key.
OUTPUT
10. Press AM again to
deselect the AM function.
AM
Example: FM modulation. 100Hz modulating square wave. 1Vpp, 1kHz Sine wave carrier. 100 Hz frequency deviation. Internal Source.
Output
50
W
MAIN
1. Press the FUNC
key repeatedly to select the Sine wave.
FUNC
2. Press FREQ > 1 >
kHz.
FREQ
1
kHz/Vrms
3. Press AMPL > 1 >
Vpp.
AMPL
1
Hz/Vpp
4. Press FM.
FM
5. Press Shift >
INT/EXT > select INT source.
Shift
+
INT/EXT
kHz/Vrms

FM (2100 series only)

25
AFG-2000 Series User Manual
6. Press Shift > Shape
repeatedly to select Square wave.
Shift
+
Shape
AM
7. Press Shift > Rate
> 1 > 0 > 0 > Hz.
Shift
+
Rate FSK
1
0
0
Hz/Vpp
8. Press Shift >
DEP/DEV> 1 > 0 > 0> Hz
Shift
+
DEP/DEV
FM
100
Hz/Vpp
9. Press the OUTPUT
key.
OUTPUT
10. Press FM again to
deselect the AM function.
FM
Example: FSK modulation. 10Hz Hop frequency. 1Vpp, 1kHz Ramp carrier wave. 100 Hz Rate (modulation frequency). Internal Source.
Output
50
W
MAIN
1. Press the FUNC
key repeatedly to select the Ramp wave.
FUNC
2. Press FREQ > 1 >
kHz.
FREQ
1
kHz/Vrms
3. Press AMPL > 1 >
Vpp.
AMPL
1
Hz/Vpp

FSK Modulation (2100 series only)

26
QUICK REFERENCE
4. Press FSK.
FSK
5. Press Shift >
INT/EXT > select INT source.
Shift
+
INT/EXT
kHz/Vrms
6. Press Shift > Rate
> 1 > 0 > 0 > Hz.
Shift
+
Rate FSK
100
Hz/Vpp
7. Press Shift > Hop >
1 > 0 > Hz.
Shift
+
Hop
MHz/dBm
1
0
Hz/Vpp
8. Press the OUTPUT
key.
OUTPUT
9. Press FSK again to
deselect the FSK function.
FSK
27
AFG-2000 Series User Manual
Example: Frequency Sweep. Start Frequency 1Hz, Stop Frequency 1MHz. 1Hz Rate. 1Vpp. Linear Sweep.
Output
50
W
MAIN
1. Press the FUNC
key repeatedly to select the Ramp wave.
FUNC
2. Press AMPL > 1 >
Vpp.
AMPL
1
Hz/Vpp
3. Press Sweep.
Sweep
4. Press Shift >
INT/EXT > select INT source.
Shift
+
INT/EXT
kHz/Vrms
5. Press Shift >
Start/Stop select Start> 1 > Hz.
Shift
+
Start/Stop
Sweep
1
Hz/Vpp
6. Press Shift >
Start/Stop select Stop> 1 > MHz.
Shift
+
Start/Stop
Sweep
1
MHz/dBm
7. Press Shift > Rate
> 1 > Hz.
Shift
+
Rate FSK
1
Hz/Vpp
8. Press Shift >
LIN/LOG > select LINS.
Shift
+
LIN/LOG
%

Sweep (2100 series only)

28