Warranty & Service ............................................................................................ 15
SAFETY & PRECAUTION
Thank you for purchasing the La LiLi 5 spa from Gulfstream Inc. Please carefully read the instructions before
installing the spa. Carefully follow the instructions and your spa will give you years of beauty and service.
This product is to be connected to a branch circuit outlet protected by a Class A GROUND FAULT CIRCUIT
INTERRUPTER (GFCI), and the GFCI shall be tested regularly for continued protection and correct
operation. If a Class A GFCI protected outlet is not available, DO NOT USE THIS PRODUCT! Please
contact a licensed electrician for installation of a Class A GFCI according to local electric codes, or equivalent.
1
Warning
The foot-spa must be installed by a licensed plumber and electrician in accordance with local codes. Plumbing and
Electrical Installation instructions must be adhered to in order for the warranty to be in effect and to ensure the utmost
in safety. The chair and spa have a maximum seating capacity of 350 pounds.
The foot-spa is not intended to be stood in or used as a step. The portable foot-spa model is movable, standing in tub
or using as a step may cause severe damage to the unit as well as possible serious injury to the person.
Warning
THIS PRODUCT IS FOR INDOOR USE ONLY
DISCONNECT POWER SUPPLY CORD BEFORE SERVICING AND CLEANING
If a crack occurs in the glass bowl, DO NOT manually handle the bowl unless the proper attire is worn.
Under no circumstances may the bowl be used by your customers as you could be held accountable for
any injury that may occur. Gulfstream is not liable for any injury that may occur.
BASIC PRECAUTIONS SHOULD ALWAYS BE OBSERVED, INCLUDING THE FOLLOWING:
1. Read and follow all instructions
2. DANGER. To reduce the risk of injury, do not permit children to use this unit unless they are supervised
at all times
3. Use this unit only for its intended use as described in this manual. Do not use attachments that are not
recommended by the manufacturer.
4. Never drop or insert any object into any opening.
5. Do not block jets during whirlpool operation.
6. The unit must be connected to an electrical supply circuit that is protected by a ground fault circuit interrupter.
7. The clean jet motor is magnetically driven and is insulated twice. Therefore, it does not require to be bonded.
Save these instructions
1. Excessive water temperature is dangerous and should be checked BEFORE using.
2. The maximum temperature of the water should never exceed 100 degrees F.
3. Always enter and exit the Foot Spa slowly and carefully.
Warning
4. NEVER bring and / or operate any electrical devices into or near the Foot Spa.
5. NEVER run the pump (Jet/Motor) unless the pump body fully submerged in water.
Water level in the bowl to be above the top of Jet body.
DO NOT Run Jet dry.
SAFETY & PRECAUTION
2
GROUNDING METHODS
Because this unit must be connected to a circuit with a ground-fault circuit interrupter (GFCI),
DO NOT use a grounding adapter.
The use of a grounding adapter is prohibited in Canada by Part I of the Canadian Electrical Code.
GROUNDING INSTRUCTIONS
This appliance must be plugged into an outlet equipped with a ground-fault circuit interrupter. The ground-fault
interrupter can be in the outlet shown in illustration A or in the circuit breaker (fuse) box. If your outlet or circuit breaker
(fuse) box is not equipped with a ground-fault interrupter, you must have your electrician install one (5 amps/unit
required).
In the event of an electrical short-circuit, the ground-fault circuit interrupter will turn off the electrical power to the unit
immediately, greatly reducing the likelihood of serious injury. This appliance is for use with a nominal 120-volt circuit and
has a grounding plug that looks like the plug illustrated in the sketch. The outlet must be properly installed and grounded
in compliance with all local codes and ordinances.
If it is necessary to use an extension cord, use only a three-wire extension cord that has a three-blade grounding plug
and a three-slot receptacle that will accept the plug on the appliance.
Replace any damaged cord.
AB
COMPLIANCE WITH LOCAL CODES AND/OR
Grounding PIN
GROUND-FAULT
INTERRUPTER OUTLET
NEMA 5-15R
NOT INCLUDED
INSPECTIONS IS THE RESPONSIBILITY OF
THE PURCHASER AND/OR INSTALLER.
OPERATION AND USE INSTRUCTIONS, (READ AND FOLLOW ALL INSTRUCTIONS)
Warning
IMPORTANT! At the end of the day, ALWAYS turn the main power OFF!
including the power switch on the chair.
1. DANGER: To reduce the risk of injury, do not permit children to use this unit unless they are closely supervised
at all times.
2. CAUTION: This unit should not be used by persons with open wounds, cuts or sores on their feet or legs, or by
persons with poor circulation, or by persons with heart conditions. If in doubt, the client should consult with his
or her physician.
3. Use this unit only for its intended use as described in this manual. Do not use attachments not recommended
by the manufacturer
4. Do no operate with a damaged cord or plug. If unit malfunctions or is damaged in any manner,
contact an authorized service representative for examination or repair.
5. Never drop or insert any objects into any opening.
6. Do not block jets during pedicure operation.
7. Water temperature should be checked before use. Water temperature should never exceed 100 degrees
Fahrenheit.
8. Never bring any electrical devices into the unit or operate electrical devices near it.
9. The unit must be connected to a supply circuit that is protected by a ground-fault circuit interrupter (GFCI).
10. Connect the unit only to a properly grounded outlet. See grounding instructions.
11. Close supervision is necessary when the unit is used by, on or near children or invalids.
IDENTIFY YOUR FOOT-SPA
3
5
7
6
Back
4
Front
231
Storage
8
9
1. Water Mixer Control
2. Bowl
3. Flip-out Manicure Tray
4. Back Cushion & Massage
5. Wooden Armrest
6. Seat Cushion
7. Jet Mount
8. Drain
9. Adjustable Footrest
10. Drain Control
11. Jet Control
12. Hand Spray
Control Panel
1101112
IDENTIFY YOUR FOOT-SPA
4
SEAT OPERATION
Armrest can be raised up/down
Manicure tray can be folded up/down
Reclining 25°
2
Swing out manicure tray to use
accessories bowl
(Swing-out Accessories Bowl Access is
available in the 9622 and 9620-1 chairs.)
1
3
Chair Sliding
SPA DIMENSION
27”
55’’
32”
43’’
15’’