Guest Industrial 2613A, 2620A, 2623A, 2631A Owners Manual

R
Trolling Charger Series
OWNER’S MANUAL
ON BOARD BATTERY CHARGERS
Models Amperage No. Of Banks Volts 2613A 5,5,5 Amps 3 Bank 12/24/36 2620A 10,10 Amps 2 Banks 12/24 2623A 10,5,10 Amps 3 Banks *12 or 24 2631A 10,10,10 Amps 3 Banks 12/24/36
* : See Connection diagrams for warnings.
IMPORTANT NOTICE
This manual contains important safety and operating instructions for the charger. Read the entire manual before using. Also read all instructions and cautions for and on the charger, batteries and equipment in the vicinity of the batteries.
1.
INTRODUCING THE CHARGER
The Guest model 2613A, 2620A, 2623A and 2631A are designed to both recharge your batteries, and extend your battery’s life in applications where it is stored for long periods of time. They are “3-stage” electronic, completely automatic, lightweight, silent, battery chargers and each output produces 12 Volts DC at either a full 5 Amps or 10 Amps (model specific), while using much less AC current than other charger types. Unlike automotive “trickle” chargers, the 2613A, 2620A, 2623A and 2631A will not boil off the electrolytes in properly installed and maintained batteries. When the charger is attached to your batteries and plugged into a standard 115 Volt / 60 Hz AC outlet, the red and green LED’s, mounted on the face of the charger let you know the unit is recharging and maintaining your batteries. This sophisticated device is ideal for recharging and maintaining the 12VDC batteries in your boat, electric vehicle or cart, ATV, snowmobile or motorcycle.
727759 Rev H
SAVE THESE INSTRUCTIONS
WARNINGS
THIS CHARGER SHOULD BE USED TO CHARGE ONLY LEAD ACID OR GEL CELL TYPE BATTERIES. USE ON OTHER BATTERY TYPES MAY EXPLODE AND CAUSE PERSONAL INJURY.
RISK OF EXPLOSIVE GASES! WORKING IN THE VICINITY OF LEAD ACID BATTERIES IS DANGEROUS. BATTERIES GENERATE EXPLOSIVE GASES DURING NORMAL OPERATION. THEREFORE IT IS OF THE UTMOST IMPORTANCE THAT EACH TIME BEFORE USING YOUR CHARGER YOU FOLLOW THE INSTRUCTIONS EXACTLY.
Personal Safety Precautions
Adhere to the following personal safety precautions when installing or working with the chargers:
1.
Someone should be within voice range or close enough to come to your aid when you work near a lead-acid battery.
2.
Have plenty of fresh water and soap nearby in case battery acid contacts skin, clothing, or eyes.
3.
Wear complete eye protection and clothing protection. Avoid touching eyes while working near a battery.
4.
If battery acid contacts skin or clothing, wash them immediately with soap and water. If acid enters the eye, flood the eye with cold, running water for at least ten minutes and get medical attention.
5.
Never smoke or allow an open flame in the vicinity of the battery.
6.
Do not drop a metal tool onto the battery. It may spark, short circuit the battery and may cause an explosion.
7.
Remove all personal metal items such as rings, bracelets, necklaces, and watches when working near a lead-acid battery. A battery can produce short circuit currents high enough to weld a ring or the like to metal, causing a severe burn.
Preparing to Charge Precautions
Before charging a battery with the charger, read the following precautions:
1.
Do NOT operate the charger if the cables or an LED is damaged.
2.
Make sure all accessories on the product you are charging are OFF.
3.
If the battery or batteries must be removed from the product, always remove the grounded terminal from the battery first.
4.
Be sure the area around the battery is well ventilated while the battery is being charged. Gas can be forcefully blown away using a piece of cardboard or other non-metallic material as a “hand fan”.
5.
Clean battery terminals. Be careful to keep corrosion from coming in contact with eyes.
727759 Rev I
2
EC 3429
6.
Add distilled water in each cell until battery acid reaches levels specified by the battery manufacturer, if applicable. Do not overfill. For a battery without cell caps, carefully follow the manufacturer’s recharging instructions.
7.
Never allow the ring terminals to touch each other.
8.
NEVER charge a frozen battery.
9.
Please be sure the DC system to which the charger is connected is not drawing
excessive current from the battery for extended periods of time while the charger is operating. This is important to ensure the charger correctly transitions through each charging stage to finish with the float voltage level. If the DC system is drawing continuous current while charging, reduced life or damage to the battery may occur.
AC Connection and Grounding Precautions
DANGER
DO NOT OPERATE THIS CHARGER WITH A TWO BLADED ADAPTER PLUG OR EXTENSION CORD. DOING SO CAN RESULT IN SERIOUS PERSONAL INJURY.
AFTER SECURING THE BATTERY CONNECTIONS, PLUG THE AC LINE CORD INTO AN AVAILABLE AC OUTLET THAT IS PROTECTED BY A GROUND FAULT CIRCUIT INTERRUPTER (GFCI) BREAKER.
CAUTION: To reduce the risk of shock, connect only to a properly grounded outlet.
NOTE: AC Line Cord color coding is EU style. Line = Brown, Neutral = Blue, Ground =
Green
2. INSTALLING THE CHARGER
Choosing Charging Location
The charger should have at least eight inches of unobstructed area on all sides of the unit for effective cooling. The case of this charger will become warm during operation. Because the charger is convection cooled (airflow over the back of the charger), the optimum mounting position for the charger is vertical. Mounting on its back on a horizontal surface may cause the charger to slightly reduce amperage output due to the thermal protection built in. Do not install the charger on carpeted, upholstered, or varnished surfaces.
Mounting the Charger
1.
Use corrosion resistant ¼” dia. bolts, backed by a flat washer, and secured to the mounting surface with a split-ring lock washer.
2.
Hold the charger to the mounting surface and mark the holes.
3.
Remove the charger and drill the mounting holes.
4.
Align the charger and assemble the mounting hardware. Secure.
727759 Rev I
3
EC 3429
Making DC Connections
Check polarity of the battery posts. The POSITIVE (POS., P, +) battery post usually has a larger diameter than the NEGATIVE (NEG., N, -) post. Connect Red charger output wire to POSITIVE post, Black charger wire to NEGATIVE. See below diagrams for more details.
Making AC Connections
Connect the AC plug into an AC receptacle, which is protected by a Ground Fault Circuit Interrupter (GFCI) breaker.
Battery Size Recommendations
The recommended maximum battery size per 5 amp bank is 60AH. The recommended maximum battery size per 10 amp bank is 120AH.
2613A Connections
Model
Output
Volts
2613A 12/24/36 5/5/5 3 6’/4’/4’ 9.6 x 7 x 2.6
Diagram 1. 2613A (5/5/5 Amps) used with 3 independent 12V Batteries
Output
Amps
Banks
DC Cable Size
Size (inches)
L x W x H
Input Volts
Input
Amps Max
115VAC
3.5 Amp
50/60Hz
727759 Rev I
4
EC 3429
2613A Connection Warnings: For the 2613A, only output 2 and output 3 may be connected in parallel for a 12 V 10 amp output. The engine start output (Output
1) may not be connected in parallel with output 2 & 3.
2613A Connections
Diagram 2. 2613A used in a 24V system
To use a 2613A in a 36V system connect all 3 outputs in series.