Gucbir GJB13000E, GJB13000E-3 User Manual

1
GUCBIR GENERATOR
GJB13000E / GJB13000E-3 USER MANUAL
Congratulation and thank you for your purchase our products; out aim is to provide a high-quality generator set to achieve customer satisfaction, and we are confident that your choice will be justified. This manual, dealing with the generator side of the unit, gives all the basic information to ensure satisfactory and reliable operation of your. Please use this manual as a companion to the other manual covering the engine side.
2
Caution
1. Use SAE 10W-30 Lubrication oil. After the first oil change at 10 hours operation, change it every 50 hours.
2. Do not connect the generator output to commercial AC outlets.
3.For information about the engine operation and maintenance, please see[IMC or
HONDA engines Owners Manual]
3
NAMES OF IMPORTANT PARTS AND COMPONENTS
4
MODEL
11000
11000S
13000
13000S
GENERATO
R
AC Output
50 Hz
Prime
8.5KW
8.5KW
10.5KW
10.5KW
Standby
10.5KW
10.5KW
11.5KW
11.5KW
60 Hz
Prime
10.0KW
10.0KW
12.0KW
12.0KW
Standby
11.0KW
11.0KW
13.0KW
13.0KW
Rated Speed
3000rpm(50Hz)/3600rpm(60Hz)
Phase
Single Two line(4)
Three Four line
Single Two line(4)
Three
Four line
Power Factor
1.0
0.8
1.0
0.8
Excitation System
Self-Excitation System
Pole
2
Drive System
Directly Couplde to the Engine
Voltages
110/220
220/380
110/220
220/380
Voltages Regulation
±1.5% at rated rpm
5
MODEL
GX620
GX670
ENGINE
Output
Prime
16.0hp/3000rpm,18.0hp/3600pm
18.0hp/3000rpm,20.0hp/3600rpm
Standby
18.0hp/3000rpm,20.0hp/3600pm
20.0hp/3000rpm,22.0hp/3600rpm
Type
4-stroke,overhead valve,2 cylinders(900 v-Twin)
Cylinder Volume
614cc
627cc
NO.of Cylinder
2
Starting System
Electric(Recoil)
Fuel Consumption
3.5L/hour
(at full load)
3.7L/hour
(at full load)
Fuel Tank Capacilty
26
26
Noise level(7m/dB)
72/50Hz, 78/60Hz
71/50Hz, 77/60Hz
Net Weight(with Wheels)
151(160)kg
157(166)kg
153(162)kg
155(160)kg
Dimensions(with wheels)
950×620×800
*Option-Voltage
6
PREPARATORY STEPS FOR OPERATION
1. ENVIRONMENTAL REQUIREMENTS
1-1.Outdoor use A) Istall your gasotine generator unit in a dry and dustless place.
B) Avoid the direct sunshine. Place your IMC G.G.unit in the shade. C) Keep your gasotine generator unit on a level ground so that the unit will not move by itself. For safely, fix the unit on the ground
by pegging.