P9035 perforated 316 stainless steel liner and 2” of insulation – noise attenuation up to 23 dB
P9037 urethane internal coating – noise attenuation up to 11 dB
P9038 empty shell – noise attenuation up to 8 dB
retardant class “0” rating – noise attenuation up to 25 dB
Options
Color yellow, custom colors available, additional charges may apply
Accessories
SR40 Explosion Proof Speaker/Ringer 110 dB
• CE20 Explosion Proof Line Powered Ringer 90 dB
Industrial and Hazardous Area Telephones for all Applications
Model AB1000
Package Contents ............................................................................... 2
Models ................................................................................................ 2
Options ............................................................................................... 2
Accessories ........................................................................................ 2
Overview ............................................................................................. 3
Features.............................................................................................. 3
Installing the AB1000 .......................................................................... 3
Specifications ...................................................................................... 9
Warranty ........................................................................................... 10
Disclaimer ......................................................................................... 10
Service Telephone Number ............................................................... 10
Feedback .......................................................................................... 10
Guardian Product Return .................................................................. 11
Cleaning Tips for Guardian Telephones ............................................ 12
Storage ............................................................................................. 12
Figure 1 - Front View........................................................................... 4
Figure 2 - Side View ............................................................................ 5
Figure 3 - Back View ........................................................................... 6
Figure 4 - Top View ............................................................................. 7
Figure 5 - Bottom View ........................................................................ 8
Package Contents
•
•
•
•
•
high performance polyurethane acoustic liner resistant to mildew and rot and with fire
•
•
•
•
![](/html/48/48fb/48fb95a9e56adc4e42be6b66c84ff0dac190310506e3ab00ed6ee79735130350/bg3.png)
Guardian Telecom Installation and Operation
The AB1000 Acoustic Booth provides privacy and a comfortable environment in which to hold a
telephone conversation, by dampening surrounding noises by 23 dB or more.
• constructed of Glass Reinforced Plastic (GRP)
Polyester Gelcoat molded into finish
uses corrosion resistant materials
convenient shelf for writing, with pencil lip and water drain holes
• Liner options – no liner, Urethane coating, 50mm (2”) insulation behind perforated stainless steel
or high performance polyurethane resistant to mildew and rot with fire retardant class “0” rating
10” x 16” (254mm x 406mm) reinforced area on the back panel for mounting communication
devices
6” x 8” (132mm x 203mm) reinforced area on the top panel for mounting strobe lights, loud
ringers or other signaling devices
easy to drill material for customizing assembly
Follow all local codes and requirements when installing the AB1000
Acoustic Booth.
Choose a wall location that is free of obstructions and permits space for
installation and wiring.
Ensure that the mounting can support the weight of the booth with
• If appropriate install roughed-in wiring and conduit prior to mounting the
booth.
• Mount the unit on the surface selected. Use 3/8” (10mm) bolts and washers
or equivalent to secure the unit.
• The AB1000 Acoustic Booth is now ready to receive the communication
convenient to aid in wiring.
Connect an approved earth ground to the metal lining of the booth.
Model AB1000
Overview
Features
•
•
•
•
•
•
Installing the AB1000
•
The AB1000 is large and heavy; it should always be handled by more
•
•
•
communication device installed, plus any wind force and/or body weight that
apparatus with associated wiring. Secure equipment to the reinforced areas
of the booth using appropriate fasteners. Holes may be drilled wherever
•
See: Figures 1-5 for
dimensions.
Tip: The AB1000
Acoustic Booth weighs
50 lbs (23 kg)
See: Figures 1-5
See: Figure 3 - Back
View
![](/html/48/48fb/48fb95a9e56adc4e42be6b66c84ff0dac190310506e3ab00ed6ee79735130350/bg4.png)
Guardian Telecom Installation and Operation
Model AB1000
Figure 1 - Front View
![](/html/48/48fb/48fb95a9e56adc4e42be6b66c84ff0dac190310506e3ab00ed6ee79735130350/bg5.png)
Guardian Telecom Installation and Operation
Model AB1000
Figure 2 - Side View