HEPA Dirt Cup Filter FLTB
Exhaust Filter FLTA
Belt BLT1
Model No. GGU350TT
1-Year Limited Warranty
www.germguardian.com
1.866.603.5900
REV0609
Date Purchased
month ________
year _________
!
WARNING:
Cleaner assembly may include
small parts. Small parts can
present a choking hazard.
E-1
Page 2
THIS VACUUM IS INTENDED FOR HOUSEHOLD USE ONLY
IMPORTANT SAFETY INSTRUCTIONS
When you use an appliance, basic precautions should always be followed.
Please read the entire manual before using this appliance.
READ ALL INSTRUCTIONS BEFORE USE.•
ALWAYS FOLLOW SAFETY INSTRUCTIONS.•
BRING VACUUM TO AN UPRIGHT POSITION IF NOT USING IN CANISTER MODE TO •
USE THE HOSE AND ATTACHMENTS.
DO NOT LEAVE VACUUM CLEANER UNATTENDED WHEN PLUGGED IN.•
REGULARLY CHECK FILTERS TO CLEAN OR REPLACE.•
DO NOT OPERATE VACUUM WITHOUT FILTERS.•
WARNING: DO NOT USE SHARP OBJECTS TO CLEAN OUT THE HOSE SINCE THEY •
COULD CAUSE DAMAGE.
OCCASIONALLY REMOVE BRUSHROLL AND REMOVE DEBRIS FROM END CAPS TO •
ENSURE BRUSHROLL ROTATES SMOOTHLY.
WARNING: THE CORDS, WIRES AND/OR CABLES SUPPLIED WITH THIS VACUUM •
CONTAIN CHEMICALS, INCLUDING LEAD OR LEAD COMPOUNDS KNOWN TO
THE STATE OF CALIFORNIA TO CAUSE CANCER AND BIRTH DEFECTS OR OTHER
REPRODUCTIVE HARM. WASH HANDS AFTER USING.
!
WARNING:
To reduce the risk of electric shock, this vacuum has a polarized plug (one blade is wider than
the other). This plug will t in a polarized outlet only one way. If the plug does not t fully in the
outlet, reverse the plug. If it still does not t, contact a qualied electrician to install the proper
outlet. Do not change the plug in any way.
THIS VACUUM IS INTENDED FOR HOUSEHOLD USE ONLY
IMPORTANT SAFETY INSTRUCTIONS
!
WARNING: TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK OR INJURY:
Do not leave appliance when plugged in. Unplug vacuum from wall outlet when not in use and •
before servicing or performing any maintenance on the unit.
Do not use outdoors or on wet surfaces. Electrical shock could occur.•
Do not use as a toy. Close attention and supervision is necessary when used by or near •
children.
Use only as described in this manual. Use only manufacturer's recommended attachments •
and replacement parts such as lters, belts and headlights.
Do not use with damaged cord or plug. If vacuum is not working as it should, has been •
dropped, damaged, left outdoors or dropped in water, return it to the manufacturer for service
or call 1.866.603.5900 for more information.
Do not pull or carry by cord, use cord as a handle, close a door on the cord, vacuum over the •
cord, pull around sharp corners or edges. Keep cord away from heated surfaces.
Do no unplug by pulling on cord. To unplug, grasp the plug and not the cord.•
Do not handle plug or vacuum with wet hands.•
Do not put any objects into openings. Do not use vacuum with any openings that are blocked. •
Keep all openings free of dust, lint, hair and anything that may reduce air ow.
Keep loose hair, clothing, ngers and all parts of the body away from openings and •
moving parts.
Keep animals away from openings and moving parts.•
Do not pick up anything that is burning or smoking, such as cigarettes, matches or hot ashes.•
Do not use without dirt cup container and lters in place. If the vacuum is not working as it •
should please call customer service at 1.866.603.5900 or visit www.germguardian.com.
Turn off all controls before unplugging.•
Use extra care when cleaning on stairs or under furniture.•
Do not use to pick up ammable or combustible liquids such as gasoline or use in areas where •
they may be present.
Keep the vacuum cleaner on the oor. Only handheld vacuum cleaners may be set on furni•ture.
Do not use an extension cord with this vacuum.•
Store the vacuum indoors. Put the vacuum away after use to prevent tripping accidents.•
Using improper voltage may result in damage to the motor and possible injury to the user. •
Proper voltage is listed on the data label located on the vacuum cleaner.
SAVE THESE INSTRUCTIONS
E-2
E-3
Page 3
PLEASE READ ALL INSTRUCTIONS BEFORE USING THIS APPLIANCE
WARNING! Do not use the Dirt Cup Handle to move the cleaner.
THERMAL RESET BUTTON:
Operates due to overheating, caused by a full dirt cup, clogged lter or blocked pipes.
Unplug the cleaner and remove the blocked materials. To operate again, after
cooling down the cleaner about 30 minutes, press the Thermal Reset Button.
HOSE CRADLE ASSEMBLY
HOSE CRADLE ASSEMBLY
Set hose cradle on the top of the cleaner. (Fig. 1)•
Using a Phillips screwdriver, secure the 3/4-inch screw.•
Model .................................................. GGU350TT
Belt .................................................................... Yes
Handle
Extension
Button
Handle Inlet
Body
Cord
Storage
Hooks
Canister
Handle
Handle
Cord Clip
Handle Hose Connector
(TOOLS/CANISTER MODE)
Hose Cradle
Hose
Hose Clip
Handle Removal
Button
Base Hose
Connector
(UPRIGHT MODE)
Fig. 1
VACUUM ASSEMBLY: UPRIGHT USE
HOSE ASSEMBLY
HOSE ASSEMBLY
Insert the body end of the hose into the hose inlet on the top of the cleaner. (Fig. 2)•
Line up circular tab on hose cuff with inner groove. (Fig. 2)•
Connect and twist clockwise to secure proper hose connection. (Fig.3)•
Place hose in hose cradle. (Fig. 4)•
Insert the base end of the hose into the hose inlet on the base of the cleaner. (Fig. 5)•
IMPORTANT: Hose must be connected to inlet on base of vacuum to work in the UPRIGHT
mode.
E-4
Canister
Release Pedal
Headlight
Base
Thermal Reset
Button
Handle Release
Pedal
Cord
Plug
Fig. 2
Fig. 3
Hose
Base Hose
Connector
Fig. 5
Fig. 4
Detail of
Hose Lock
E-5
Page 4
HANDLE ASSEMBLY
VACUUM ASSEMBLY: UPRIGHT USE (CONTD)
HANDLE ASSEMBLY
Insert handle in the handle inlet on the top of the body. (Fig. 6)•
HANDLE DISASSEMBLY
Push the handle removal button.•
Pull handle upward to remove.•
BASE ASSEMBLY
Set the body on the top of the base. (Fig. 7)•
Use both sides of the guide feature on the •
base to align.
BASE DISASSEMBLY
Push the release canister pedal.•
Lift up and remove the body.•
BASE ASSEMBLY
Canister
Release Pedal
Base
Fig. 6
Handle
Protrustion to Lock
Guides
Handle Inlet
Handle
Removal
Button
TOOL ASSEMBLY
TOOL ASSEMBLY
Attach crevice tool, dusting brush and upholstery brush into •
storage area on the back of the vacuum. (Fig. 8)
Fig. 8
USING IN UPRIGHT MODE
USING IN UPRIGHT MODE
Push the Handle Release Pedal (Fig. 9)
Turn main power switch ON. Turn brush power switch ON.•CAUTION•: The headlight and brush does not come on when in the upright
position even if the switch is ON. You must release the handle for the brushroll
to begin spinning. (Fig. 10)
Base
Fig. 10
Fig. 9
Handle Release
Pedal
HEIGHT ADJUSTMENT KNOB
HEIGHT ADJUSTMENT KNOB
Rotate the height adjustment knob to the correct carpet height. (Fig. 11)•
To clean bare oor, set this knob to the bare oor position and turn off the brush power •
switch. (Located on the top of the cleaner - see page 2)
Base Safety
Switch
Crevice
Tool
Dusting
Brush
Upholstery
Brush
E-6
Fig. 7
Fig. 11
E-7
Page 5
UPRIGHT MODE: TOOL USAGE
TOOL USAGE
Turn brush OFF.1.
Remove hose from base hose connector on the lower portion of the cleaner. (Fig. 12)2.
Remove handle from cleaner: Push handle removal button and pull up on handle to 3.
disconnect from body. (Fig. 13)
Insert hose into handle hose connector and twist clockwise to lock in position. (Fig. 14)4.
Push button on wand to extend telescoping wand. (Fig. 15)5.
Select the tool needed for above-oor cleaning and attach to end of wand.6.
STORING IN UPRIGHT MODE
After using the vacuum, store in upright mode.•
Store accessories on the storage clips located on the vacuum body.•
Wrap the cord around the cord storage hooks on the side of the body and hang the •
plug at the cord clip on the wand. (Fig. 18)
Handle
Handle
Hose
Base Hose
Connector
Fig. 12
Removal
Button
Fig. 13
CONVERTING TO CANISTER MODE
CONVERTING TO CANISTER MODE
Remove hose from base hose connector. (Fig. 16)1.
Step on Canister Release Pedal and pull body upward by canister handle. (Fig. 17)2.
Follow steps 3-5 in UPRIGHT MODE: TOOL USAGE section. (See above)3.
Insert end of handle into hard oor nozzle.4.
Canister mode.5.
Hose
Fig. 14
Handle Hose
Connector
Telescoping
Button
Handle
Hard Floor
Nozzle
Handle
Cord
Fig. 15
Cord Clip
Plug
Fig. 18
Canister
Handle
E-8
Hose
Base Hose
Connector
Body
Canister Release
Pedal
Base
Fig. 16
Fig. 17
IMPORTANT:
When returning to UPRIGHT mode hose MUST be removed
from handle and returned to inlet on body.
E-9
Page 6
CLEANING DIRT CUP
You will need to empty dirt cup when dust reaches the FULL line.•
Turn OFF the vacuum and unplug from electrical outlet.•
Grasp the dirt cup handle and depress button, pull out the dirt cup from •
the body. (Fig. 19)
To empty, remove the dirt cup and hold over trash bin. Push the dirt release •
button and dispose of the dirt. (Fig. 20)
Body
CLEANING & REPLACING FILTER
TO OPTIMIZE THE VACUUM PERFORMANCE YOU SHOULD CLEAN THE
FILTER EACH TIME YOU EMPTY THE DIRT CUP.
1. Lift up the dirt cup cover, rotate and remove the lter protector.
2. Rotate and remove the inner lter. (Fig. 21)
Tap the inner lter on a trash bin to remove the dust from the pleats. (Fig. 22)
NOTE: This inner lter is washable and can be rinsed if you notice a reduction in
vacuum performance (suction). To wash, rst tap lter to remove excess dirt and
dust from pleats. Rinse lter clean with warm water then allow to completely dry
(a minimum of 24 hours) before returning to dirt cup. Use lter: FLTB for inner dirt cup.
Dirt Cup Cover
*HEPA Filter is located
INSIDE the green lter
Filter Protector
protector. Remove lter
protector to access
HEPA Filter.
Tap Gently
Dirt Cup
Release Button
Dirt Cup
Fig. 19
Dirt Cup
Release Button
Fig. 20
HEPA
Inner Filter
(Located inside
Filter Protector)
*
Fig. 21Fig. 22
EXHAUST FILTER CLEANING & REPLACEMENT
Pull out the exhaust lter. (Fig. 23)•
Replace the exhaust lter when it becomes dirty. (Fig. 24) •
Use lter: FLTA for exhaust lter.
NOTE: This lter is washable.
Filter Frame
-
Exhaust
Filter
Body
Fig. 24
Fig. 23
Filter
E-10
NOTE: Replacement parts can be purchased by calling
1.866.603.5900 or by visiting www.germguardian.com.
E-11
Page 7
BELT REPLACEMENT
WARNING: BEFORE REPLACING THE BELT, MAKE SURE THE CLEANER
IS UNPLUGGED FROM THE ELECTRICAL OUTLET.
Turn OFF the cleaner and unplug from electrical outlet.•
Remove the bottom plate of the base by removing the ve (5) screws using a •
Phillips screwdriver. (Fig. 25)
Set the new belt over motor pulley. (Fig. 26) Use replacement belt: •BLT1.
Slip the brush roll into the belt and reassemble. (Fig. 27)•
Replace the bottom plate and secure the 5 screws.•
TROUBLESHOOTING GUIDE
Please check each item below if you have trouble with your vacuum.
Before checking, always ensure that the vacuum is unplugged from the power supply.
PROBLEMPROBLEMSOLUTION
Vacuum won't run.
1. Power cord not rmly plugged
into the outlet.
2. Motor protector tripped.
3. Needs service.
1. Plug in unit rmly.
2. Cool down and press the RESET button.
(See page 3)
3. Take to service center or call 1.866.603.5900.
Motor Pulley
Fig. 25Fig. 26Fig. 27
HEADLIGHT REPLACEMENT
WARNING: BEFORE REPLACING THE HEADLIGHT, MAKE SURE THE CLEANER
IS UNPLUGGED FROM THE ELECTRICAL OUTLET.
Turn OFF the cleaner and unplug from electrical outlet.•
Press the handle release pedal and use the handle to place the body in a at position.•
Remove the headlight cover by removing the screw with a Phillips screwdriver. (Fig. 28)•
Pull the bulb straight out of the socket. (Fig. 29)•
Install the new bulb, model LBU.•
Replace the headlight cover and secure the screw.•
Headlight
Cover
Headlight
Brush roll won't spin.1. Vacuum is not in the
Vacuum or tool won't
pick up dirt.
Vacuum is difcult
to push.
UPRIGHT mode.
2. Brush switch is OFF.
3. Brush roll is jammed.
4. Belt is broken or off
motor pulley.
1. Incorrect height setting.
2. Hose not attached to:
A. Inlet
B.Base.
3. Clogged hose.
4. Dirt cup is full.
5. Inner lter is blocked.
6. Crack or hole in hose.
1. Incorrect height setting.
2. Brush switch is OFF.
1. The brush only turns on when the handle is
released for vacuuming. The brush does not come
on in the UPRIGHT position even if the switch is
ON. Depress handle for brushroll to start turning.
2. Make sure the brush switch is ON.
3. Remove it and clean debris, hair, etc. off of
brush, then replace.
4. Replace the new belt or correct the belt's securing.
(See page 11)
1. Rotate height adjustment knob to correct height
setting. (See page 6)
2A. Check hose connection and make sure it is
attached to proper inlet: base inlet on body
(UPRIGHT) or inlet on handle (CANISTER/TOOLS).
2B. Grasp hose tube and rmly push onto base.
3. Try to remove clog by squeezing out of hose.
4. Empty dirt cup (see page 9); if washed, after
dried well, reinsert it.
5. Clean or replace with new. (See page 10)
6. Take to service center or call 1.866.603.5900.
1. Rotate height adjustment knob to correct height
setting. (See page 6)
2. Make sure the brush switch is ON.
E-12
Fig. 28Fig. 29
NOTE: Replacement parts can be purchased by calling
1.866.603.5900 or by visiting www.germguardian.com.
Visible dust escaping
from vacuum.
1. Dirt cup is full.
2. Filter missing or incorrectly
installed.
3. Dirt cup installed incorrectly.
1. Empty dirt cup (see page 9); wash it, after dried
well, replace it.
2. Check inner lter and exhaust lter for
correct installation.
3. Pull out and re-insert dirt cup correctly.
E-13
Page 8
LIMITED WARRANTY
To the consumer, Guardian Technologies LLC warrants this product to be free of
defects in materials and workmanship commencing upon the date of the original
purchase. Save your original sales receipt to validate start of warranty period.
If this product should become defective within the warranty period, we will repair
or replace any defective parts free of charge. The complete machine must be
delivered pre-paid to any authorized Guardian Technologies LLC warranty service
center. Please include complete information on the problem, date of purchase, copy
of original sales receipt and your name, address and telephone number. If you are
not near a warranty station, call the factory for assistance in the US and Canada at
1.866.603.5900. Use only genuine Guardian Technologies' replacement parts.
The warranty does not include unusual wear, damage resulting from accident
or unreasonable use of the product. This warranty does NOT cover bulbs. This
warranty does NOT cover unauthorized repairs. This warranty gives you specic
legal rights and you may have other rights (other rights may vary from state to
state in the U.S.A).
We consider the registration process important to ensuring superior service to our
customers, however submitting this card to Guardian Technologies LLC is optional
and does not affect your right to utilize this warranty according to the conditions
above. If you have any questions or comments about our product call Toll Free at
1.866.603.5900 or send comments to: ATTN Customer Service
Guardian Technologies LLC
7700 St. Clair Avenue
Mentor, Ohio 44060
E-14
Guardian Technologies LLC
7700 St Clair Avenue | Mentor Ohio 44060
1.866.603.5900 | www.germguardian.com
Loading...
+ hidden pages
You need points to download manuals.
1 point = 1 manual.
You can buy points or you can get point for every manual you upload.